Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Structural Analysis of Helios Filament-Wound Tanks Subjected to Internal Pressure and Cooling

A finite-element stress analysis is performed on Helios filament-wound hydrogen tanks to examine the stress field and effect of end dome geometry on the stress field. Each tank is composed of a central circular cylindrical section with either geodesic or hemispherical end domes, which have metallic polar bosses. The tanks are subjected to combined and separate internal pressure and temperature loading conditions, and the stress contributions of each loading component are examined. The tank-wall-polar-boss interfacial meridional tensile stress in the hemispherical dome is found to be approximately 27 percent lower than that in the geodesic dome. The effects of both material anisotropy and the aluminum lining on the intensities of tensile meridional stress at the tank-wall-polar-boss bonding interface are examined.

Ko, William L↗

Tethered Space Satellite-1 (TSS-1): Wound About a Bolt

In the early 1990's US and Italian scientists collaborated to study the electrodynamics on a long tether between two satellites as it moved through the electrically charged portion of Earth's atmosphere called the ionosphere. Potential uses for the electrical current induced in the long wire include power and thrust generation for a satellite, momentum exchange, artificial gravity, deployment of sensors or antennas, and gravity-gradient stabilization. The Tethered Space Satellite (TSS) was a first-of-its-kind experiment with long tethers in space. It consisted of a satellite with science experiments attached to a 12.5 mile long, very thin (0.10 inch diameter) copper wire assembly wound around a spool in the deployer reel mechanism. The whole mechanism sits on a pallet that is installed into the Shuttle bay. At an altitude of 160 nautical miles above earth, the satellite would be deplodeployed from the Shuttle bay by raising it on a boom facing away from Earth. Once cleared of the bay, the deployer mechanism would slowly feed out the 12-plus miles of tether. Scientific data would be collected throughout the operation, after which the satellite would be reeled back in. A receiver spool to catch the 12.5 mile tether as it was being unwound by the deployer reel mechanism was set up to do the system-level test of deployer real mechanism prior to installing the loaded pallet into the Shuttle bay. The system level tests were required before the pallet could be installed into the Space Shuttle cargo bay. A few months before flight, the system level tests, including unreeling and reeling the tether, were completed at Kennedy Space Center (KSC) and the TSS payload was installed onto the Spacelab pallet. Some of this testing equipment was then shipped back to the contractor, Martin Marietta. Integration with the Shuttle began. Systems-level load analyses, which cannot be run until all information about each payload is finalized, was run in parallel with the physical integration of the hardware into the Shuttle payload bay. An analysis, called Coupled loads analysis, incorporates any updates to the model due to system level tests of all the different payloads, and any changes that were found during integration. Engineering analysis examines the worst case scenarios for the loads the hardware will see. The two times during the mission where the dynamic loads are the worst were 1) the first 10-second portion of Shuttle lift off, and 2) a 2-second time during landing when the landing gears hit the ground. The coupled loads analysis using the final verification loads showed that a single bolt attaching the deployer reel mechanism to the support structure had a "negative margin" - which is an indication that it might fail - during touch down. Hardware certification rules do not allow for hardware to fly with negative margins. A structural failure of one payload could have serious or catastrophic consequences to other payloads, or may significantly damage the Orbiter. The issue had to be resolved before the flight.

O'Connor, Brian↗

A Damage Resistance Comparison of Wet-Wound IM7 and T1100 Carbon Fiber/Epoxy Cylinders

This technical report presents the results of a damage tolerance comparison of two wet-wound cylinders; one made with IM7 carbon fiber and the other with T1100 carbon fiber. Damage was inflicted on the cylinders in the form of impact and the resulting damage was assessed mainly by cross-sectional examination of the damage zone after impact. Due to financial restraints, no residual strength testing was performed in this study. The amount of fiber breakage was the response variable of interest since fiber breakage, rather than delaminations or other matrix damage, governs the burst strength of rocket motor cases. The results showed that the T1100 fiber may be slightly more damage resistant than the IM7 fiber.

A T Nettles↗

Carbon fiber composites for cryogenic filament-wound vessels

Advanced unidirectional and bidirectional carbon fiber/epoxy resin composites were evaluated for physical and mechanical properties over a cryogenic to room temperature range for potential application to cryogenic vessels. The results showed that Courtaulds HTS carbon fiber was the superior fiber in terms of cryogenic strength properties in epoxy composites. Of the resin systems tested in ring composites, CTBN/ERLB 4617 exhibited the highest composite strengths at cryogenic temperatures, but very low interlaminar shear strengths at room temperature. Tests of unidirectional and bidirectional composite bars showed that the Epon 828/Empol 1040 resin was better at all test temperatures. Neither fatigue cycling nor thermal shock had a significant effect on composite strengths or moduli. Thermal expansion measurements gave negative values in the fiber direction and positive values in the transverse direction of the composites.

Larsen, J. V.↗

Filament-wound vessel from an organic fiber-epoxy system.

We evaluated the PRD-49-III fiber by winding 4-in. vessels in an epoxy matrix. From over 130 vessels of various designs, the best average vessel performance factor (PV/W) based on fiber was 2,500,000 in.; based on the composite it was 1,800,000 in. The highest average fiber-failure stress was 446 ksi. It is evident that for shell structures that involve minimal shear loading this fiber/epoxy material system is indeed very attractive.

Chiao, T. T.↗

Performance of filament-wound vessels from an organic fiber in several epoxy matrices

A study was carried out to select a state-of-the-art epoxy for wet filament winding. Ten epoxy systems were used to filament wind pressure vessels with a high-modulus, high-strength organic fiber. Data are reported on vessel performance, fiber strand strengths, and shear strengths for the different systems. Using our criteria (processibility, neat resin properties, and vessel performance), we find that an epoxy system based on the rubber-modified bis-phenol-F resin, diluted with vinyl cyclohexane dioxide and cured with mixed aromatic amines, can easily replace bis-phenol-A epoxies diluted with bis-(2, 3-epoxycyclopentyl) ether (such as ERL 2256 epoxy of Union Carbide) with comparable overall performance.

Chiao, T. T.↗

Identification and management of filament-wound case stiffness parameters

The high specific strength and the high specific modules made graphite epoxy laminate an expedient material substitute for the Shuttle Solid Rocket Motor steel case to substantially increase the payload performance without increasing the composite case axial growth during thrust build up which was constrained to minimize liftoff excitation effects on existing structural elements and interfaces. Parameters associated with axial growth were identified for quality and manufacturing controls. Included is an innovative method for experimentally verifying extensional elastic properties on a laminate pressurized test bottle.

Verderaime, V.↗

Test Report for MSFC Test No. 83-2: Pressure scaled water impact test of a 12.5 inch diameter model of the Space Shuttle solid rocket booster filament wound case and external TVC PCD

Water impact tests using a 12.5 inch diameter model representing a 8.56 percent scale of the Space Shuttle Solid Rocket Booster configuration were conducted. The two primary objectives of this SRB scale model water impact test program were: 1. Obtain cavity collapse applied pressure distributions for the 8.56 percent rigid body scale model FWC pressure magnitudes as a function of full-scale initial impact conditions at vertical velocities from 65 to 85 ft/sec, horizontal velocities from 0 to 45 ft/sec, and angles from -10 to +10 degrees. 2. Obtain rigid body applied pressures on the TVC pod and aft skirt internal stiffener rings at initial impact and cavity collapse loading events. In addition, nozzle loads were measured. Full scale vertical velocities of 65 to 85 ft/sec, horizontal velocities of 0 to 45 ft/sec, and impact angles from -10 to +10 degrees simulated.

Source record↗

Pretest Plan for a Quarter Scale AFT Segment of the SRB Filament Wound Case in the NSWC Hydroballistics Facility

In support of preflight design loads definition, preliminary water impact scale model are being conducted of space shuttle rocket boosters. The model to be used as well as the instrumentation, test facilities, and test procedures are described for water impact tests being conducted at test conditions to simulate full-scale initial impact at vertical velocities from 65 to 85 ft/sec. zero horizontal velocity, and angles of 0,5, and 10 degrees.

Adoue, J. A.↗

Space Shuttle filament wound case compressive strength study. II - Analysis

In order to explain the results of the testing conducted in Part I and relate the subscale test specimen performance to case performance during prelaunch loading, a comprehensive analysis program was conducted. Finite element models of both full-scale case and subscale test coupons were made. Validated axisymmetric models were used for the case analyses. Modeling of coupons was accomplished using a generalized plane strain finite element model in most cases, although some three-dimensional finite element modeling was used to investigate the importance of three-dimensional effects on the coupon performance. The large number of plies and complexity of the test coupons used limited the finite element grids to a through-the-thickness discretization of one element per ply. Delaminations observed in the helical ply dropoff region were modeled using frictionless sliders. Comparisons of predicted strains and displacements were made with the test data from both cases and coupons to validate the finite element models. Based on observations of the test results and finite element predictions, a failure criterion for both coupons and cases was postulated and then validated by comparing performance predictions to test results. Finally, the validated failure criterion was used to predict the performance of the first two flight cases under prelaunch loads.

Messick, M. J.↗

Making Linked, Wound-Filament Bands

Chains produced by use of rotating mandrel. Mandrel and locating and driving disks assembled around first band. Mandrel and band then mounted in respective positions on filament-winding machine. Second band linked to first by winding filament around first band on rotating mandrel. Short chains made this way have variety of uses; example, thermal isolators, each consisting of two linked bands of insulating material, used to support two separated insulating sheilds surrounding container of liquid helium.

Bamford, Robert M.↗

Filament wound data base development, revision 1, appendix B

The data tape 8 data are presented in tabular form. Each page consists of six-component force and moment coefficients as they vary with angle of attack at a specific Mach number and roll angle. The angle of attack range is from 0 to 180 deg in 5 deg increments. The six coefficients are normal force, pitching moment, side force, yawing moment, axial force, and rolling moment. Each successive page is incremented for roll angle in 45 deg increments for a roll angle range from 0 to 360 deg. The cycle is then repeated for the next Mach number. The Mach numbers in the data base are 0.4, 0.5, 0.55, 0.6, 0.7, 0.8, 0.9, 0.95, 1.05, 1.1, 1.2, 1.4, 1.96, 2.5, 3.0, and 3.48.

Sharp, R. Scott↗