At least 145 records · Page 8

Compression of photon wave packets in the soft-x-ray region

Using a tapered undulator and a double grating system we have compressed soft-x-ray photon wave packets into 37% of the original length. To confirm the shortening of the length of wave packets, we employed a special analog method to measure two-photon correlation as it is without elongating the wave-packet length, while the previous two-photon correlation measurements had adopted the method to largely elongate the wave-packet length up to several hundred fs using a monochromator. The present method gives a new prospect in that the compressed wave-packet length is extremely short and of the order of 1 fs, which enables various soft-x-ray spectroscopic experiments to detect in the time domain fast elementary excitations in a solid.

74 ATOMIC AND MOLECULAR PHYSICS↗

THz pulses from 4th generation X-ray light sources: Perspectives for fully synchronized THz pump X-ray probe experiments

In this paper the prospects of terahertz (THz) pulses generated at 4th generation X-ray light sources are presented on the example of recent results from a prototype set-up at the soft X-ray FEL FLASH. It is shown, that the THz pulses from the relativistic ultra short electron bunches have unique properties, that at FLASH are utilized for novel THz pump X-ray probe experiments with a robust few fs resolution. Based on these experiences it is discussed, how future facilities can benefit from implementation of similar or further improved instrumentation.

43 PARTICLE ACCELERATORS↗

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

Synchrotron Radiation from a Laser Plasma Accelerator in the Bubble Regime

A laser wakefield accelerator is shown to operate in the highly non-linear bubble regime, following the characteristic scaling of energy gain with density and leading to monoenergetic electron beams with up to 400 MeV and hundreds of pC charge. The bubble acts at the same time as a miniature undulator, causing the electrons to give off a beam of betatron x-rays with milliradian divergence, {mu}m source size, 1-100 keV photon energy and 10{sup 22} ph/mm{sup 2}/mrad{sup 2}s/0.1% BW.

43 PARTICLE ACCELERATORS↗

Projection of excited orbitals into kinetic energies of emitted electrons in resonant Si KLL Auger decays of SiF{sub 4}

Spectator resonant Auger-electron spectra have been measured in the Si 1s photoexcitation region of SiF{sub 4} using an electron spectroscopic technique combined with undulator radiation. A transition with the highest intensity in the total ion yield spectrum, which comes from excitation of a 1s electron into the 6t{sub 2} valence orbital, generates resonant Auger decays in which the excited electron remains predominantly in the valence orbital or is partly shaken up into a high-lying Rydberg orbital. The higher-lying peak generated through excitation into Rydberg orbitals induces resonant Auger decays in which the excited Rydberg electron is partly shaken up to a higher-lying Rydberg orbital or shaken down to a lower-lying valence molecular orbital. These findings exhibit a clear disentanglement effect among excited orbitals which are smeared out in the 1s electron excitation spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Turkish Accelerator Center (TAC) Project: Status and Regional Importance

The Turkish Accelerator Center (TAC) Project was started in 1997 with support of the State Planning Organization (SPO) of Turkey under Ankara University's coordination. After completing Feasibility Report (FR, 2000) and Conceptual Design Repot (CDR, 2005), third phase of the project was started in 2006 as an inter-university project with support of SPO. Third phase of the project has two main scientific goals: to write Technical Design Report (TDR) of TAC and to establish an Infrared Free Electron Laser (IR FEL) facility as a first step. The first facility and TDR studies are planned to be completed in 2012. Construction phase of TAC will cover 2013-2023. TAC collaboration include ten Turkish Universities: Ankara, Gazi, Istanbul, Bogazici, Dogus, Uludag, Dumlupmar, Nigde, Erciyes and S. Demirel Universities. It was planned that the first facility will be an IR FEL and Bremsstrahlung laboratory based on 15-40 MeV electron linac and two optical cavities with 2.5 and 9 cm undulators to scan 2-250 microns wavelength range. Main purpose of the facility is to use IR FEL for research in material science, nonlinear optics, semiconductors, biotechnology, medicine and photochemical processes. In this study; aims, regional importance, main parts and main parameters of TAC and TAC IR FEL and Bremsstrahlung facility are explained. Road map of the TAC project is given. National and international collaborations are explained.

43 PARTICLE ACCELERATORS↗

Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

43 PARTICLE ACCELERATORS↗

Simultaneous XAFS measurements of multiple samples

A four-channel ionization chamber has been designed, constructed and tested. This ionization chamber allows X-ray absorption spectra to be collected in transmission from up to four samples simultaneously. This results in spectra that are free of systematic uncertainty in relative energy alignment introduced by scan-to-scan stability of the monochromator or of numerical uncertainty associated with a post-processing alignment algorithm, allowing, in a single shot, an absolute measure of edge shift between four samples of different valence. As four samples can be measured in parallel, the time expended over the course of an experiment to cycle the measurement environment between its rest state and the measurement condition is substantially reduced. The ionization chamber is simple in design and could be implemented at virtually any XAFS beamline with a horizontal fan of radiation such as that provided by a bend magnet or wiggler.

47 OTHER INSTRUMENTATION↗

Status of the Metrology Light Source

The Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute, has set up the low-energy electron storage ring Metrology Light Source (MLS) in close cooperation with the Helmholtz-Zentrum Berlin (HZB, formerly BESSY). This new storage ring has been in regular user operation since April 2008 and is dedicated to synchrotron-radiation-based metrology and technological developments in the far-IR/THz, IR, UV, VUV and EUV spectral range. The MLS has a double-bend-achromate lattice structure, injection is from a 105 MeV racetrack microtron. The electron energy can be ramped to any value from 105 MeV up to 630 MeV and the electron beam current covers the range from one stored electron (1 pA) up to 200 mA. The MLS is the first electron storage ring optimized for the generation of coherent synchrotron radiation, based on an electron bunch shortening mode. In this mode, MLS delivers coherent radiation in the far-IR/THz spectral range with enhanced intensity as compared to the normal mode of operation. Several beamlines are in operation or in construction, including one undulator beamline, bending magnet beamlines for the calibration of radiation sources and detectors and for reflectometry, an EUV metrology beamline and three IR/THz beamlines.

43 PARTICLE ACCELERATORS↗

The Optimized Design of Undulators for the HiSOR Users Experiments

The HiSOR is a small racetrack type storage ring aiming for usage of synchrotron radiation. This ring is equipped with two undulators. One of them is a linear undulator and another is a helical one. These undulators serve high-flux VUV photon beams. Therefore, these beamlines are oversubscribed mainly for the high precision photo-electron spectroscopy experiments to investigate various materials. To solve this problem, we investigated possibilities to replace present undulators and beamline optics to those with better performance. One of such candidate undulator beamlines is a two-branch-beamline with a single elliptical undulator. Another candidate is a beamline equipped with a quasi-periodic undulator.

43 PARTICLE ACCELERATORS↗

A Numerical Algorithm to Calculate the Pressure Distribution of the TPS Front End Due to Desorption Induced by Synchrotron Radiation

The pressure distribution is an important aspect of a UHV subsystem in either a storage ring or a front end. The design of the 3-GeV, 400-mA Taiwan Photon Source (TPS) foresees outgassing induced by photons and due to a bending magnet and an insertion device. An algorithm to calculate the photon-stimulated absorption (PSD) due to highly energetic radiation from a synchrotron source is presented. Several results using undulator sources such as IU20 are also presented, and the pressure distribution is illustrated.

43 PARTICLE ACCELERATORS↗

Optimization of the Coherent Intensity from Multi-Segment Undulators by Phase Matching

The use of inline insertion devices at third-generation synchrotron radiation sources can result in destructive interference effects if the relative phase between the devices is not properly adjusted. The destructive interference can strongly affect the emission spectrum and coherent wavefront of a compound insertion device. We simulate the photon source generated by a dual-inline elliptically polarizing undulator (EPU) situated in a low-{beta} straight section of the planned NSLS-II storage ring and show that a magnetic chicane with adjustable field integral can be used to phase-match the devices. Furthermore, we show that the maximum coherent intensity is delivered by a focusing x-ray beamline if the chicane is adjusted to phase-match the off-axis and red-shifted radiation. Such a system will be installed at the coherent soft x-ray (CSX) beamline of the NSLS-II in order to provide the highest possible coherent flux for coherent soft x-ray scattering experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Algorithms to automate gap-dependent integral tuning for the 2.8-meter long horizontal field undulator with a dynamic force compensation mechanism

A 2.8-meter long horizontal field prototype undulator with a dynamic force compensation mechanism has been developed and tested at the Advanced Photon Source (APS) at Argonne National Laboratory (Argonne). The magnetic tuning of the undulator integrals has been automated and accomplished by applying magnetic shims. A detailed description of the algorithms and performance is reported.

43 PARTICLE ACCELERATORS↗

Estimate of Undulator Magnet Damage Due to Beam Finder Wire Measurements

Beam Finder Wire (BFW) devices will be installed at each break in the Undulator magnet line. These devices will scan small wires across the beam causing some electrons to lose energy through bremsstrahlung. The degraded electrons are subsequently detected downstream of a set of vertical dipole magnets after they pass through the vacuum chamber. This signal can then be used to accurately determine the beam position with respect to the BFW wire. The choice of the wire diameter, scan speed, and operating parameters, depends on the trade-off between the signal size and the radiation damage to the undulator magnets. In this note I estimate the rate of undulator magnet damage that results from scanning as a function of, wire size, scan speed, and average beam current. A separate analysis of the signal size was carried out by Wu. The damage estimate is primarily based on two sources: the first, Fasso, is used to estimate the amount of radiation generated and then absorbed by the magnets; the second, Alderman et. al., is used to estimate the amount of damage the magnet undergoes as a result of the absorbed radiation. Fasso performed a detailed calculation of the radiation, including neutron fluence, that results from a the electron beam passing through a 100 micron diamond foil inserted just in front of the undulator line. Fasso discussed the signficance of various types of radiation and stated that photoneutrons probably play a major role. The estimate in this paper assumes the neutron fluence is the only significant cause of radiation-induced demagnetization. The specific results I use from Fasso's paper are reproduced here in Figure 1, which shows the radial distribution of the integrated neutron fluence per day in the undulator magnets, and Figure 2, which shows the absorbed radiation dose all along the undulator line. In the longitudinal dimension, Fasso's calculation, (see Figure 2), shows that the radiation dose is widely distributed all along the undulator line, but is highest around 70 m from the front of the undulator line where the foil is. At the 70 m point, for the purpose of calculating the demagnetization, I chose a conservative estimate for the effective neutron flux of 1.0 x 10{sup 13} n/cm{sup 2}/day. As can be seen in Figure 1, this choice is representative of the flux nearest the beam where it is the highest. A less conservative estimate, but perhaps more accurate, estimate of the effective flux, would be the average flux in the magnet block, which is roughly one half as much.

43 PARTICLE ACCELERATORS↗

Status and Prospects of Coherent Light Source Developments at UVSOR-II

We are developing coherent light sources at the UVSOR-II electron storage ring. We have developed a resonator type free electron laser in the visible to the deep UV range, coherent harmonic generation source in VUV range and coherent synchrotron radiation source in the terahertz range. A new five year plan has been started from FY2008, where a new 4m straight section will be created by moving the beam injection point, a new optical klystron type undulator will be installed and dedicated beam-lines will be constructed. Great advances on the coherent light source developments at the new straight section are expected.

43 PARTICLE ACCELERATORS↗

A Versatile Multilayer Polarimeter for the Soft X-Ray Region

As modern undulators can generate light with arbitrary polarization states, experiments exploiting this feature in the range of soft x-rays have become increasingly widespread. For the success of these experiments characterising the polarization at the sample position is vital. Therefore a versatile, multi-purpose, UHV compatible, multilayer polarimeter has been designed and developed for measuring the Stokes vector of a soft x-ray beam. This high-precision, ultra high vacuum compatible instrument is supported by a Hexapod to simplify its alignment. Furthermore, the instrument has its own independent control system and has been designed for portability so that it can be moved with relative ease between different synchrotron facilities. The polarization analysis requires the rotation of a phase retarder and a polarization analyser, both about a common axis of the photon beam. The polarimeter employs reflection / transmission multilayers as phase retarders / analysers. Several sets of multilayers are installed inside the UHV chamber so that they may be exchanged in-situ without breaking the vacuum. The polarimeter doubles-up as a reflectometer / ellipsometer that enable determination of the polarization properties of optical elements including multilayers with very small surface roughness and several hundred bi-layers. The design details of the polarimeter and the results of first experiments to characterise the polarization of a beamline will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Coherent X-ray Diffraction Apparatus with Kirkpatrick-Baez Mirror Optics

To realize coherent x-ray diffraction microscopy with higher spatial resolution, it is necessary to increase the density of x-ray photons illuminated onto the sample. In this study, we developed a coherent x-ray diffraction apparatus with Kirkpatrick-Baez mirror optics. By using mirrors fabricated by elastic emission machining, a high-density coherent x-ray beam was produced. In a demonstration experiment using a silver nanocube as a sample, a high-contrast coherent x-ray diffraction pattern was observed over a wide-q range. This proves that both the density and the degree of coherence of the focused beam were high.

07 ISOTOPE AND RADIATION SOURCES↗

Proposal of a Bulk HTSC Staggered Array Undulator

We proposed a new type of undulator based on bulk high-T{sub c} superconductors (HTSC) which consists of a single solenoid and a stacked array of bulk HTSC. The main advantage of this configuration is that a mechanical structure is not required to produce and control the undulator field. In order to perform a proof of principle experiment, we have developed a prototype of bulk HTSC staggered array undulator using 11 pairs of DyBaCuO bulk superconductors and a normal conducting solenoid. Experimental results obtained by using the prototype undulator and numerical results obtained by a loop current model based on the Bean mode for a type-II superconductor were compared.