Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WALLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 1: 2x6 Walls

Part 1 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides time-proven, practical, and cost-effective strategies for constructing durable, energy-efficient walls. It addresses walls constructed with 2x6 wood frame studs, wood structural panel (WSP) exterior sheathing, and a cladding system installed over WSP sheathing in low-rise residential buildings up to three stories high.

2x6 wood frame studs↗

Construction Guide to Next-Generation High-Performance Walls in Climate Zones 3-5 - Part 1: 2x6 Walls

Part 1 of this Construction Guide to High-Performance Walls in Climate Zones 3-5 provides time-proven, practical, and cost-effective strategies for constructing durable, energy-efficient walls. It addresses walls constructed with 2x6 wood frame studs, wood structural panel (WSP) exterior sheathing, and a cladding system installed over WSP sheathing in low-rise residential buildings up to three stories high.

2x6 wood frame studs↗

Tritium plasma experiment: Parameters and potentials for fusion plasma-wall interaction studies

The tritium plasma experiment (TPE) is a unique facility devoted to experiments on the behavior of deuterium/tritium in toxic (e.g., beryllium) and radioactive materials for fusion plasma-wall interaction studies. A Langmuir probe was added to the system to characterize the plasma conditions in TPE. With this new diagnostic, we found the achievable electron temperature ranged from 5.0 to 10.0 eV, the electron density varied from 5.0 x 10{sup 16} to 2.5 x 10{sup 18} m{sup -3}, and the ion flux density varied between 5.0 x 10{sup 20} to 2.5 x 10{sup 22} m{sup -2} s{sup -1} along the centerline of the plasma. A comparison of these plasma parameters with the conditions expected for the plasma facing components (PFCs) in ITER shows that TPE is capable of achieving most ({approx}800 m{sup 2} of 850 m{sup 2} total PFCs area) of the expected ion flux density and electron density conditions.

36 MATERIALS SCIENCE↗

Real-time wall conditioning by controlled injection of boron and boron nitride powder in full tungsten wall ASDEX Upgrade

In ASDEX Upgrade with full-tungsten wall, boronization is an important tool to control tungsten sources and allow reliable operation at low collisionality. The duration of the beneficial effects is limited by the erosion of the boron layer, in particular on the tungsten ion-cyclotron antenna limiters. We report results from experiments exploring injection boron-rich powders in tokamak plasmas as a way to replenish boron coating and extend the lifetime of boronization effects. Pure boron and boron nitride powders were introduced gravitationally in plasma discharges at rates up to 60 mg/s for durations up to 3 s. Boron injection with cumulative amounts >100 mg appeared to improve wall conditions similarly to boronization, with indications of reduced influx of oxygen and tungsten from the antenna limiter. Moreover, cumulative injection of 340 mg of B appeared sufficient to enable successful execution of low collisionality scenarios critically relying on freshly boronized walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrodynamic dispersion in thin channels with micro-structured porous walls

Flowand transport within porous- and microtextured-walled channels is relevant to a number of natural and industrial processes. Designing and optimizing the topology of the pores and/or microstructure to achieve target performance at the system scale (or macroscale) is still an open question. In this work, we study whether hydrodynamic dispersion in microfluidic channels with walls structured by obstacles can be modeled by dispersion in channels with porous walls described as continuous porous media of zero or finite permeability. We perform single phase microfluidic non-reactive flow experiments in channels embedded in micropatterns with different topologies. Specifically, we focus on transverse riblets and arrays of pillars as examples of impermeable and permeable obstructions, respectively. We compare the experimental results with three models: 3D pore-scale simulations which resolve the micropattern geometry explicitly and two upscaled models which treat the micropattern as a continuum of zero or finite permeability. This study demonstrates that polydimethylsiloxane micromodels with appropriately patterned surfaces can be successfully employed to validate various continuum-scale modeling approximations in different physical regimes, identified by the order of magnitude of the Peclet number and the obstruction permeability.

Ling, Bowen↗

Evidence for the Importance of Trapped Particle Resonances for Resistive Wall Mode Stability in High Beta Tokamak Plasmas

Active measurements of the plasma stability in tokamak plasmas reveal the importance of kinetic resonances for resistive wall mode stability. The rotation dependence of the magnetic plasma response to externally applied quasistatic n=1 magnetic fields clearly shows the signatures of an interaction between the resistive wall mode and the precession and bounce motions of trapped thermal ions, as predicted by a perturbative model of plasma stability including kinetic effects. The identification of the stabilization mechanism is an essential step towards quantitative predictions for the prospects of ''passive'' resistive wall mode stabilization, i.e., without the use of an ''active'' feedback system, in fusion-alpha heated plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Versatile Click-Compatible Monolignol Probe to Study Lignin Deposition in Plant Cell Walls

Here, lignin plays important structural and functional roles in plants by forming a hydrophobic matrix in secondary cell walls that enhances mechanical strength and resists microbial decay. While the importance of the lignin matrix is well documented and the biosynthetic pathways for monolignols are known, the process by which lignin precursors or monolignols are transported and polymerized to form this matrix remains a subject of considerable debate. In this study, we have synthesized and tested an analog of coniferyl alcohol that has been modified to contain an ethynyl group at the C-3 position. This modification enables fluorescent tagging and imaging of this molecule after its incorporation into plant tissue by click chemistry-assisted covalent labeling with a fluorescent azide dye, and confers a distinct Raman signature that could be used for Raman imaging. We found that this monolignol analog is incorporated into in vitro -polymerized dehydrogenation polymer (DHP) lignin and into root epidermal cell walls of 4-day-old Arabidopsis seedlings. Incorporation of the analog in stem sections of 6-week-old Arabidopsis thaliana plants and labeling with an Alexa-594 azide dye revealed the precise locations of new lignin polymerization. Results from this study indicate that this molecule can provide high-resolution localization of lignification during plant cell wall maturation and lignin matrix assembly.

59 BASIC BIOLOGICAL SCIENCES↗

High-R Walls for Remodeling: Wall Cavity Moisture Monitoring

The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-R Walls for Remodeling: Wall Cavity Moisture Monitoring

The focus of the study is on the performance of wall systems, and in particular, the moisture characteristics inside the wall cavity and in the wood sheathing. Furthermore, while this research will initially address new home construction, the goal is to address potential moisture issues in wall cavities of existing homes when insulation and air sealing improvements are made.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hot wire production of single-wall and multi-wall carbon nanotubes

Apparatus (210) for producing a multi-wall carbon nanotube (213) may comprise a process chamber (216), a furnace (217) operatively associated with the process chamber (216), and at least one filament (218) positioned within the process chamber (216). At least one power supply (220) operatively associated with the at least one filament (218) heats the at least one filament (218) to a process temperature. A gaseous carbon precursor material (214) operatively associated with the process chamber (216) provides carbon for forming the multi-wall carbon nanotube (213). A metal catalyst material (224) operatively associated with the process (216) catalyzes the formation of the multi-wall carbon nanotube (213).

Dillon, Anne C.↗

ICRF Specific Plasma Wall Interactions in JET with the ITER-Like Wall

A variety of plasma wall interactions (PWIs) during operation of the so-called A2 ICRF antennas is observed in JET with the ITER-like wall. Amongst effects of the PWIs, the W content increase is the most significant, especially at low plasma densities. No increase of W source from the main divertor and entrance of the outer divertor during ICRF compared to NBI phases was found by means of spectroscopic and WI (400.9 nm) imaging diagnostics. In contrary, the W flux there is higher during NBI. Charge exchange neutrals of hydrogen isotopes could be excluded as considerable contributors to the W source. The high W content in ICRF heated limiter discharges suggests the possibility of other W sources than the divertor alone. Dependencies of PWIs to individual ICRF antennas during q95-scans, and intensification of those for the 90 phasing, indicate a link between the PWIs and the antenna near-fields. The PWIs include heat loads and Be sputtering pattern on antenna limiters. Indications of some PWIs at the outer divertor entrance are observed which do not result in higher W flux compared to the NBI phases, but are characterized by small antenna-specific (up to 25% with respect to ohmic phases) bipolar variations of WI emission. The first TOPICA calculations show a particularity of the A2 antennas compared to the ITER antenna, due to the presence of long antenna limiters in the RF image current loop and thus high near-fields across the most part of the JET outer wall.

Bobkov, V.↗

Hierarchical calibration and validation framework of bench-scale computational fluid dynamics simulations for solvent-based carbon capture. Part 2: Chemical absorption across a wetted wall column: Original Research Article: Hierarchical calibration and validation framework of bench-scale computational fluid dynamics simulations

Part 1 of this paper presents a numerical model for non-reactive physical mass transfer across a wetted wall column (WWC). In Part 2, we improved the existing computational fluid dynamics (CFD) model to simulate chemical absorption occurring in a WWC as a bench-scale study of solvent-based carbon dioxide (CO 2 ) capture. In this study, to generate data for WWC model validation, CO 2 mass transfer across a monoethanolamine (MEA) solvent was first measured on a WWC experimental apparatus. The numerical model developed in this work can account for both chemical absorption and desorption of CO 2 in MEA. In addition, the overall mass transfer coefficient predicted using traditional/empirical correlations is conducted and compared with CFD prediction results for both steady and wavy falling films. A Bayesian statistical calibration algorithm is adopted to calibrate the reaction rate constants in chemical absorption/desorption of CO 2 across a falling film of MEA. The posterior distributions of the two transport properties, i.e., Henry's constant and gas diffusivity in the non-reacting nitrous oxide (N 2 O)/MEA system obtained from Part 1 of this study, serves as priors for the calibration of CO 2 reaction rate constants after using the N 2 O/CO 2 analogy method. Finally, the calibrated model can be used to predict the CO 2 mass transfer in a WWC for a wider range of operating conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗