Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Voxels”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Mixed Effect Modeling of Dose and Linear Energy Transfer Correlations With Brain Image Changes After Intensity Modulated Proton Therapy for Skull Base Head and Neck Cancer

Intensity modulated proton therapy (IMPT) could yield high linear energy transfer (LET) in critical structures and increased biological effect. For head and neck cancers at the skull base this could potentially result in radiation-associated brain image change (RAIC). The purpose of the current study was to investigate voxel-wise dose and LET correlations with RAIC after IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees

Definitive, nonsurgical management of gynecologic malignancies involves external beam radiation therapy (EBRT) and/or brachytherapy (BT). Summation of the cumulative dose is critical to assess the total biologic effective dose to targets and organs at risk. Cumulative dose calculation from EBRT and BT can be performed with or without image registration (IR) and biologic dose summation. Among these dose summation strategies, linear addition of dose-volume histogram (DVH) parameters without IR is the global standard for composite dose reporting. This approach stems from an era without image guidance and simple external beam and brachytherapy treatment approaches. With technological advances, EBRT and high-dose-rate BT have evolved to allow for volume-based treatment planning and delivery. Modern conformal therapeutic radiation involves volumetric or intensity modulated EBRT, capable of simultaneously treating multiple targets at different specified dose levels. Therefore, given the complexity of modern radiation treatment, the linear addition of DVH parameters from EBRT and high-dose-rate BT is challenging to represent the combined dose distribution. Deformable image registration (DIR) between EBRT and image guided brachytherapy (IGBT) data sets may provide a more nuanced calculation of multimodal dose accumulation. However, DIR is still nascent in this regard, and needs further development for accuracy and efficiency for clinical use. Biologic dose summation can combine physical dose maps from EBRT and each IGBT fraction, thereby generating a composite DVH from the biologic effective dose. However, accurate radiobiologic parameters are tissue-dependent and not well characterized. A combination of voxel-based DIR and biologic weighted dose maps may be the best approximation of dose accumulation but remains invalidated. The purpose of this report is to review dose summation strategies for EBRT and BT, including conventional equivalent dose in 2-Gy fractions dose summation without image registration, physical dose summation using 3-dimensional rigid IR and DIR, and biologic dose summation. We also provide general clinical workflows for IGBT with a focus on cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially Resolved Top-Down Proteomics of Tissue Sections Based on a Microfluidic Nanodroplet Sample Preparation Platform

Conventional proteomics measures the averaged signal from mixed cell populations or bulk tissues, leading to the dilution of significant changes in subpopulations of cells that might serve as important biomarkers. Recent developments in bottom-up proteomics have enabled spatial mapping of cellular heterogeneity in tissue microenvironments. However, bottom-up proteomics cannot precisely infer the abundance changes of intact proteins, which are presented as proteoforms. Herein, we described a spatially resolved top-down proteomics (TDP) platform for proteoform identification and quantification directly on thin tissue sections. The spatial TDP platform consisted of a nanoPOTS (nanodroplet Processing in One pot for Trace Samples)-based sample preparation system and an LCM (laser capture microdissection)-based cell isolation system. We improved the nanoPOTS sample preparation by adding benzonase in the extraction buffer to enhance the coverage of nucleus proteins. Using ~200 cultured cells as model samples, the improved approach increased proteoform identifications from 493 to 700; newly identified proteoforms primarily corresponded to nuclear proteins. To demonstrate the spatial TDP platform in tissue samples, we analyzed LCM-isolated tissue voxels from rat brain cortex and hypothalamus regions. We quantified 426 proteoforms by combining identifications from TopPIC and TDPortal with the quantitation from ProMex. Several proteoforms corresponding to the same gene exhibited mixed abundance profiles between two tissue regions, suggesting potential PTM-specific spatial distributions. The spatial TDP workflow has prospects for biomarker discovery at proteoform level from small tissue sections.

59 BASIC BIOLOGICAL SCIENCES↗

Imposing equilibrium on experimental 3-D stress fields using Hodge decomposition and FFT-based optimization

Here, we present a methodology to impose micromechanical constraints, i.e. stress equilibrium at grain and sub-grain scale, to an arbitrary (non-equilibrated) voxelized stress field obtained, for example, by means of synchrotron X-ray diffraction techniques. The method consists in finding the equilibrated stress field closest (in L 2 -norm sense) to the measured non-equilibrated stress field, via the solution of an optimization problem. The extraction of the divergence-free (equilibrated) part of a general (non-equilibrated) field is performed using the Hodge decomposition of a symmetric matrix field, which is the generalization of the Helmholtz decomposition of a vector field into the sum of an irrotational field and a solenoidal field. The combination of: a) the Euler–Lagrange equations that solve the optimization problem, and b) the Hodge decomposition, gives a differential expression that contains the bi-harmonic operator and two times the curl operator acting on the experimental stress field. These high-order derivatives can be efficiently performed in Fourier space. The method is applied to filter the non-equilibrated parts of a synthetic piecewise constant stress fields with a known ground truth, and stress fields in Gum Metal, a beta-Ti-based alloy measured in-situ using Diffraction Contrast Tomography (DCT). In both cases, the largest corrections were obtained near grain boundaries.

36 MATERIALS SCIENCE↗

Achieving geometric accuracy in FFT-based micromechanical models using conformal grid

Owing to its efficiency, simplicity and robustness, the FFT-based method has become the standard for computation of mechanical fields in a heterogeneous periodic unit cell. One of the main disadvantages of the FFT-based method is the inaccurate representation of the initial microstructure on a regular grid of voxels, which can be alleviated through the use of distorted initial grids. Here, in this paper, a method for generation of distorted initial grids conforming to the microstructural features (e.g. straight/curved boundaries) is proposed. The method determines the positions of the grid nodes in the initial configuration by solving a system of springs connecting the nodes. Microstructures consisting of layers, Voronoi tessellation and circular/spherical inclusions are considered, and mechanical fields simulated using the FFT-based method. It is found that distorted initial grids, conforming to the microstructural features, lead to more accurate mechanical fields in comparison to the corresponding non-distorted initial grid solution. The effect of initial grid distortion on the convergence of the FFT-based method is analyzed and discussed.

36 MATERIALS SCIENCE↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quantification of the Impact of Acidified Brine on Fracture-Matrix Transport in a Naturally Fractured Shale Using in Situ Imaging and Modeling

Understanding flow, transport, chemical reactions, and hydromechanical processes in fractured geologic materials is key for optimizing a range of subsurface processes including carbon dioxide and hydrogen storage, unconventional energy resource extraction, and geothermal energy recovery. Flow and transport processes in naturally fractured shale rocks have been challenging to characterize due to experimental complexity and the multiscale nature of quantifying continuum scale descriptions of mass exchange between micrometer-scale fractures and nanometer-scale pores. In this study, we use positron emission tomography (PET) to image the transport of a conservative tracer in a naturally fractured Wolfcamp shale core before and after the core was exposed to low pH brine conditions. Image-based experimental observations are interpreted by fitting an analytical transport model to fracture-containing voxels in the core. Results of this analysis indicate subtle increases in matrix diffusivity and a slightly more uniform fracture velocity distribution following exposure to low pH conditions. These observations are compared with a multicomponent one-dimensional reactive transport model that indicates the capacity for a 10% increase in porosity at the fracture-matrix interface as a result of the low pH brine exposure. This porosity change is the result of the dissolution of carbonate minerals in the shale matrix to low pH conditions. Further, this image-based workflow represents a new approach for quantifying spatially resolved fracture-matrix transport processes and provides a foundation for future work to better understand the role of coupled transport, reaction, and mechanical processes in naturally fractured rocks.

58 GEOSCIENCES↗

Oil in Alaska North Slope Gas Hydrate Reservoir: Micro-CT and Flow Simulation Insights into Permeability

Gas hydrate-bearing sands on the Alaska North Slope (ANS) host minor volumes of crude oil whose impact on formation permeability has never been quantified relative to a gas hydrate reservoir system. Here, we combine in situ pressure-core microcomputed-tomography (μ-CT), thermogravimetric analysis (TGA), gas-chromatography–mass-spectrometry (GC–MS), scanning-electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), and Stokes-flow simulation to (i) quantify oil saturation, (ii) infer its source, and (iii) evaluate its influence on permeability after gas-hydrate dissociation. μ-CT and SEM-EDS imaging identify the host sediment as silty, with some grain-coating clay present. Eight representative 3003-voxel subvolumes extracted from a preserved pressure core (Core 15P-3c, from the B1 sand (unit B), HYDRATE 02 Geo Data Well (GDW), 886.96–887.29 m measured depth, MD) exhibit porosities of 0.34–0.37 and an average oil saturation of 0.09 ± 0.03, in comparison to an independent TGA-based estimate of 0.16. GC-MS fingerprints obtained from an adjacent depressurized core (Core 17P-1, 891.37–891.44 m MD), together with oil pore habit revealed by μ-CT, suggest that the oil is partly native but also includes contributions from mineral oil-based drilling fluid contamination. Further analysis of oil–porewater interactions and flushing tests confirms that native oil saturation in the analyzed samples ranges from 0.04 to 0.08 with an average of approximately 0.06, and the oil is highly immobile. Flow simulations demonstrate that the native oil saturation of ≈0.06 reduces permeability by approximately 50% due to both pore blockage and increased flow-path tortuosity. These findings reveal the potential presence of native oil within the ANS gas hydrate reservoir and suggest that future simulation models may need to account for its impact on permeability to improve long-term performance predictions of gas and water production.

02 PETROLEUM↗

Ultrasparse View X-ray Computed Tomography for 4D Imaging

X-ray computed tomography (CT) is a noninvasive, nondestructive approach to imaging materials, material systems, and engineered components in two and three dimensions. Acquisition of three-dimensional (3D) images requires the collection of hundreds or thousands of through-thickness X-ray radiographic images from different angles. Such 3D data acquisition strategies commonly involve suboptimal temporal sampling for in situ and operando studies (4D imaging). Herein, we introduce a sparse-view imaging approach, Tomo-NeRF, which is capable of reconstructing high-fidelity 3D images from <10 twodimensional radiographic images. Experimental 2D and 3D X-ray images were used to test the reconstruction capability in two-view, four-view, and six-view scenarios. Tomo-NeRF is capable of reconstructing 3D images with a structural similarity of 0.9971–0.9975 and a voxel-wise accuracy of 81.83–89.59% from 2D experimentally obtained images. Furthermore, the reconstruction accuracy for the experimentally obtained images is less than the synthetic structures. Experimentally obtained images demonstrate a similarity of 0.9973–0.9984 and a voxelwise accuracy of 84.31–95.77%.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Large-scale physically accurate modelling of real proton exchange membrane fuel cell with deep learning

Proton exchange membrane fuel cells, consuming hydrogen and oxygen to generate clean electricity and water, suffer acute liquid water challenges. Accurate liquid water modelling is inherently challenging due to the multi-phase, multi-component, reactive dynamics within multi-scale, multi-layered porous media. In addition, currently inadequate imaging and modelling capabilities are limiting simulations to small areas (<1 mm 2 ) or simplified architectures. Herein, an advancement in water modelling is achieved using X-ray micro-computed tomography, deep learned super-resolution, multi-label segmentation, and direct multi-phase simulation. The resulting image is the most resolved domain (16 mm 2 with 700 nm voxel resolution) and the largest direct multi-phase flow simulation of a fuel cell. This generalisable approach unveils multi-scale water clustering and transport mechanisms over large dry and flooded areas in the gas diffusion layer and flow fields, paving the way for next generation proton exchange membrane fuel cells with optimised structures and wettabilities.

25 ENERGY STORAGE↗

Scaling deep learning for material imaging with a pseudo 3D model for domain transfer

The recent introduction of deep learning methods for image processing has greatly advanced the characterization of materials using three-dimensional (3D) X-ray imaging techniques. However, deep learning models often have difficulty performing consistently across images owing to unavoidable variations in imaging conditions, which create inconsistencies even for the same material. As a result, networks must frequently be retrained for new datasets, limiting their applicability and generalization. Thus, it is critical to reduce the variations between images to enable a single model to process multiple datasets. Herein, we introduce P3T-Net, a pseudo-3D domain transfer network that transfers diverse 3D images into a uniform domain before processing using deep learning models. Remarkably, P3T-Net enables the reuse of previously trained networks for processing new images and considerably reduces the computational cost of transferring 3D images across domains. These unique capabilities were demonstrated in the following scenarios: (i) image enhancement of fast scans for geological rock and hydrogen fuel cells, (ii) enhancement of images to match the quality of multi-source imaging for lithium-ion batteries, (iii) accurate segmentation of images captured under different conditions, and (iv) tera-scale 3D transfer (10 11 voxels) on a single GPU. Overall, the proposed approach addresses cross-domain inconsistencies across various materials and conditions, thereby enabling more robust and generalizable deep learning solutions for a wide range of material imaging tasks.

25 ENERGY STORAGE↗

Artificial neural network approach for multiphase segmentation of battery electrode nano-CT images

The segmentation of tomographic images of the battery electrode is a crucial processing step, which will have an additional impact on the results of material characterization and electrochemical simulation. However, manually labeling X-ray CT images (XCT) is time-consuming, and these XCT images are generally difficult to segment with histographical methods. We propose a deep learning approach with an asymmetrical depth encode-decoder convolutional neural network (CNN) for real-world battery material datasets. This network achieves high accuracy while requiring small amounts of labeled data and predicts a volume of billions voxel within few minutes. While applying supervised machine learning for segmenting real-world data, the ground truth is often absent. The results of segmentation are usually qualitatively justified by visual judgement. We try to unravel this fuzzy definition of segmentation quality by identifying the uncertainty due to the human bias diluted in the training data. Further CNN trainings using synthetic data show quantitative impact of such uncertainty on the determination of material’s properties. Nano-XCT datasets of various battery materials have been successfully segmented by training this neural network from scratch. We will also show that applying the transfer learning, which consists of reusing a well-trained network, can improve the accuracy of a similar dataset.

25 ENERGY STORAGE↗

Bridging Nano- and Microscale X-Ray Tomography for Battery Research by Leveraging Artificial Intelligence

X-ray computed tomography (CT) is a non-destructive imaging technique in which contrast originates from the materials' absorption coefficient. The recent development of laboratory nanoscale CT (nano-CT) systems has pushed the spatial resolution for battery material imaging to voxel sizes of 50 nm, a limit previously achievable only with synchrotron facilities. Given the non-destructive nature of CT, in situ and operando studies have emerged as powerful methods to quantify morphological parameters, such as tortuosity factor, porosity, surface area and volume expansion, during battery operation or cycling. Combined with artificial intelligence and machine learning analysis techniques, nano-CT has enabled the development of predictive models to analyse the impact of the electrode microstructure on cell performances or the influence of material heterogeneities on electrochemical responses. In this Review, we discuss the role of X-ray CT and nano-CT experimentation in the battery field, discuss the incorporation of artificial intelligence and machine learning analyses and provide a perspective on how the combination of multiscale CT imaging techniques can expand the development of predictive multiscale battery behavioural models.

diagnostics↗

3D nanolithography with metalens arrays and spatially adaptive illumination

The growing demand for advanced materials, miniaturized devices and integrated microsystems calls for the reliable fabrication of complex, multiscale, three-dimensional (3D) architectures, a need increasingly addressed through light-based and laser-based processes. However, owing to the field-of-view (FOV) limitations of conventional imaging optics, existing 3D laser nanofabrication techniques face fundamental challenges in throughput, proximity error and stitching defects on the path to scaling. Here, in this study, we present a scalable 3D nanofabrication platform that uses a metalens-generated focal spot array to parallelize two-photon lithography (TPL) beyond centimetre-scale write field areas. Metalenses are ideally suited for producing submicron-scale focal spots for high-throughput nanolithography, as they uniquely feature large numerical apertures (NAs), immersion media compatibility and large-scale manufacturability. We experimentally demonstrate a printing system that uses a 12-cm 2 metalens array to produce more than 120,000 cooperative focal spots, corresponding to a throughput exceeding 10 8 voxels s −1 . By programmatically patterning the focal spot array using a spatial light modulator (SLM), an adaptive parallel printing strategy is developed for precise greyscale linewidth modulation and choreographed printing of semiperiodic and fully aperiodic 3D geometries. We demonstrate parallel printing of replicated microstructures (>50 M microparticles per day), centimetre-scale 3D architectures with feature sizes down to 113 nm, and photonic and mechanical metamaterials. This work demonstrates the potential of 3D nanolithography towards wafer-scale production, showing how TPL could be used at scale for applications in microelectronics, biomedicine, quantum technology and high-energy laser targets.

Materials science↗

Cryo2StructData: A Large Labeled Cryo-EM Density Map Dataset for AI-based Modeling of Protein Structures

The advent of single-particle cryo-electron microscopy (cryo-EM) has brought forth a new era of structural biology, enabling the routine determination of large biological molecules and their complexes at atomic resolution. The high-resolution structures of biological macromolecules and their complexes significantly expedite biomedical research and drug discovery. However, automatically and accurately building atomic models from high-resolution cryo-EM density maps is still time-consuming and challenging when template-based models are unavailable. Artificial intelligence (AI) methods such as deep learning trained on limited amount of labeled cryo-EM density maps generate inaccurate atomic models. To address this issue, we created a dataset called Cryo2StructData consisting of 7,600 preprocessed cryo-EM density maps whose voxels are labelled according to their corresponding known atomic structures for training and testing AI methods to build atomic models from cryo-EM density maps. Cryo2StructData is larger than existing, publicly available datasets for training AI methods to build atomic protein structures from cryo-EM density maps. We trained and tested deep learning models on Cryo2StructData to validate its quality showing that it is ready for being used to train and test AI methods for building atomic models.

59 BASIC BIOLOGICAL SCIENCES↗

A streamlined tandem tip-based workflow for sensitive nanoscale phosphoproteomics

Effective phosphoproteome of nanoscale sample analysis remains a daunting task, primarily due to significant sample loss associated with non-specific surface adsorption during enrichment of low stoichiometric phosphopeptide. We develop a tandem tip phosphoproteomics sample preparation method that is capable of sample cleanup and enrichment without additional sample transfer, and its integration with our recently developed SOP (Surfactant-assisted One-Pot sample preparation) and iBASIL (improved Boosting to Amplify Signal with Isobaric Labeling) approaches provides a streamlined workflow enabling sensitive, high-throughput nanoscale phosphoproteome measurements. This approach significantly reduces both sample loss and processing time, allowing the identification of >3000 (>9500) phosphopeptides from 1 (10) µg of cell lysate using the label-free method without a spectral library. It also enables precise quantification of ~600 phosphopeptides from 100 sorted cells (single-cell level input for the enriched phosphopeptides) and ~700 phosphopeptides from human spleen tissue voxels with a spatial resolution of 200 µm (equivalent to ~100 cells) in a high-throughput manner. The new workflow opens avenues for phosphoproteome profiling of mass-limited samples at the low nanogram level.

59 BASIC BIOLOGICAL SCIENCES↗

Personalized whole-brain neural mass models reveal combined Aβ and tau hyperexcitable influences in Alzheimer's disease.

Neuronal dysfunction and cognitive deterioration in Alzheimer's disease (AD) are likely caused by multiple pathophysiological factors. However, mechanistic evidence in humans remains scarce, requiring improved non-invasive techniques and integrative models. We introduce personalized AD computational models built on whole-brain Wilson-Cowan oscillators and incorporating resting-state functional MRI, amyloid-β (Aβ) and tau-PET from 132 individuals in the AD spectrum to evaluate the direct impact of toxic protein deposition on neuronal activity. This subject-specific approach uncovers key patho-mechanistic interactions, including synergistic Aβ and tau effects on cognitive impairment and neuronal excitability increases with disease progression. The data-derived neuronal excitability values strongly predict clinically relevant AD plasma biomarker concentrations (p-tau217, p-tau231, p-tau181, GFAP) and grey matter atrophy obtained through voxel-based morphometry. Furthermore, reconstructed EEG proxy quantities show the hallmark AD electrophysiological alterations (theta band activity enhancement and alpha reductions) which occur with Aβ-positivity and after limbic tau involvement. Microglial activation influences on neuronal activity are less definitive, potentially due to neuroimaging limitations in mapping neuroprotective vs detrimental activation phenotypes. Mechanistic brain activity models can further clarify intricate neurodegenerative processes and accelerate preventive/treatment interventions.

60 APPLIED LIFE SCIENCES↗