Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Views”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Tomographic analysis of tangential viewing cameras (invited)

Many tokamaks now use visible light cameras to observe plasma-wall interactions and integrated line emission. The DIII-D coherence imaging spectroscopy diagnostic cameras image interferograms that encode line integrated velocity. By modeling the 2D camera image pixels as line of sight integrals through an axisymmetric discrete grid, it is possible to do tomographic analysis to determine the local plasma line emissivity and parallel velocity. Approaches to solve the inverse problem posed by these tangential viewing cameras are presented. The inversion begins with calculation of the sparse response matrix that encompasses all the geometry and diagnostic information and reduces the process of image formation to a sparse matrix-vector multiply. Our report includes techniques for determining the detailed geometry of the camera views and methods for handling physical quantities that vary spatially. Additionally, the size of the response matrix has driven the development of capability to distribute the coarse parallel calculation across a heterogeneous cluster of computers on the Energy Sciences Network. Iterative techniques are then used to solve the sparse matrix-vector linear system

47 OTHER INSTRUMENTATION↗

SUZAKU VIEW OF THE SWIFT/BAT ACTIVE GALACTIC NUCLEI. I. SPECTRAL ANALYSIS OF SIX ACTIVE GALACTIC NUCLEI AND EVIDENCE FOR TWO TYPES OF OBSCURED POPULATION

We present a systematic spectral analysis with Suzaku of six active galactic nuclei (AGNs) detected in the Swift/BAT hard X-ray (15-200 keV) survey: Swift J0138.6-4001, J0255.2-0011, J0350.1-5019, J0505.7-2348, J0601.9-8636, and J1628.1-5145. This is considered to be a representative sample of new AGNs without X-ray spectral information before the BAT survey. We find that the 0.5-200 keV spectra of these sources can be uniformly fitted with a base model consisting of heavily absorbed (log N {sub H} > 23.5 cm{sup -2}) transmitted components, scattered lights, a reflection component, and an iron-K emission line. There are two distinct groups: three 'new-type' AGNs (including the two sources reported by Ueda et al.) with an extremely small scattered fraction (f {sub scat} < 0.5%) and strong reflection component (R = {omega}/2{pi} {approx}> 0.8, where {omega} is the solid angle of the reflector), and three 'classical-type' ones with f {sub scat} > 0.5% and R {approx}< 0.8. The spectral parameters suggest that the new type has an optically thick torus for Thomson scattering (N {sub H} {approx} 10{sup 25} cm{sup -2}) with a small opening angle {theta} {approx} 20 deg. viewed in a rather face-on geometry, while the classical type has a thin torus (N {sub H} {approx} 10{sup 23-24} cm{sup -2}) with {theta} {approx}> 30 deg. We infer that a significant number of new-type AGNs with an edge-on view are missing in the current all-sky hard X-ray surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

A MULTI-SPACECRAFT VIEW OF A GIANT FILAMENT ERUPTION DURING 2009 SEPTEMBER 26/27

We analyze multi-spacecraft observations of a giant filament eruption that occurred during 2009 September 26 and 27. The filament eruption was associated with a relatively slow coronal mass ejection. The filament consisted of a large and a small part, and both parts erupted nearly simultaneously. Here we focus on the eruption associated with the larger part of the filament. The STEREO satellites were separated by about 117 Degree-Sign during this event, so we additionally used SoHO/EIT and CORONAS/TESIS observations as a third eye (Earth view) to aid our measurements. We measure the plane-of-sky trajectory of the filament as seen from STEREO-A and TESIS viewpoints. Using a simple trigonometric relation, we then use these measurements to estimate the true direction of propagation of the filament which allows us to derive the true R/R{sub Sun }-time profile of the filament apex. Furthermore, we develop a new tomographic method that can potentially provide a more robust three-dimensional (3D) reconstruction by exploiting multiple simultaneous views. We apply this method also to investigate the 3D evolution of the top part of filament. We expect this method to be useful when SDO and STEREO observations are combined. We then analyze the kinematics of the eruptive filament during its rapid acceleration phase by fitting different functional forms to the height-time data derived from the two methods. We find that for both methods an exponential function fits the rise profile of the filament slightly better than parabolic or cubic functions. Finally, we confront these results with the predictions of theoretical eruption models.

79 ASTRONOMY AND ASTROPHYSICS↗

On the operation of X-ray polarimeters with a large field of view

The measurement of linear polarization is one of the hot topics of high-energy astrophysics. Gas detectors based on the photoelectric effect have paved the way for the design of sensitive instruments, and mission proposals based on them have been presented in the last few years in the energy range from about 2 keV to a few tens of keV. In addition, a number of polarimeters based on Compton scattering are approved or being discussed for launch on board balloons or space satellites at higher energies. These instruments are typically dedicated to pointed observations with narrow field of view telescopes or collimators, but there are also projects aimed at the polarimetry of bright transient sources such as soft gamma repeaters or the prompt emission of gamma-ray bursts. Given the erratic appearance of such events in the sky, these polarimeters have large fields of view to catch a reasonable number of them, and as a result, photons may impinge on the detector off-axis. This dramatically changes the response of the instrument to polarization, regardless of whether photoabsorption or Compton scattering is involved. Instead of the simple cosine-squared dependence expected for polarized photons that are incident on-axis, the response is never purely cosinusoidal, and a systematic modulation also appears for unpolarized radiation. We investigate the origin of these differences and present an analytical treatment that proves that such systematic effects are actually a natural consequence of how current instruments operate. Our analysis provides the expected response of photoelectric or Compton polarimeters to photons impinging with any inclination and state of polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

A far-IR view of the starburst-driven superwind in NGC 2146

NGC 2146, a nearby luminous infrared galaxy, presents evidence for outflows along the disk minor axis in all gas phases (ionized, neutral atomic, and molecular). We present an analysis of the multi-phase, starburst-driven superwind in the central 5 kpc as traced in spatially resolved spectral line observations, using far-IR Herschel PACS spectroscopy, to probe the effects on the atomic and ionized gas, and optical integral field spectroscopy to examine the ionized gas through diagnostic line ratios. We observe an increased ∼250 km s{sup –1} velocity dispersion in the [O I] 63 μm, [O III] 88 μm, [N II] 122 μm, and [C II] 158 μm fine-structure lines that is spatially coincident with high excitation gas above and below the disk. We model this with a slow ∼200 km s{sup –1} shock and trace the superwind to the edge of our field of view 2.5 kpc above the disk. We present new SOFIA 37 μm observations to explore the warm dust distribution, and detect no clear dust entrainment in the outflow. The stellar kinematics appear decoupled from the regular disk rotation seen in all gas phases, consistent with a recent merger event disrupting the system. We consider the role of the superwind in the evolution of NGC 2146 and speculate on the evolutionary future of the system. Our observations of NGC 2146 in the far-IR allow an unobscured view of the wind, crucial for tracing the superwind to the launching region at the disk center, and provide a local analog for future ALMA observations of outflows in high-redshift systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Searching for dark matter in the Galactic halo with a wide field of view TeV gamma-ray observatory in the Southern Hemisphere

Although there is mounting evidence that dark matter (DM) exists in the Universe, its fundamental nature remains unknown. We present sensitivity estimates to detect DM particles with a future very-high-energy (gsim TeV) wide field-of-view gamma-ray observatory in the Southern Hemisphere. This observatory would search for gamma rays from the annihilation or decay of DM particles in the Galactic halo. With a wide field of view, both the Galactic Center and a large fraction of the Galactic halo will be detectable with unprecedented sensitivity to DM in the mass range of ~500 GeV to ~2 PeV . These results, combined with those from other present and future gamma-ray observatories, will likely probe the thermal relic annihilation cross section of Weakly Interacting Massive Particles for all masses from ~80 TeV down to the GeV range in most annihilation channels.

79 ASTRONOMY AND ASTROPHYSICS↗

A PANORAMIC VIEW OF THE MILKY WAY ANALOG NGC 891

Recent panoramic observations of the dominant spiral galaxies of the Local Group have revolutionized our view of how these galaxies assemble their mass. However, it remains completely unclear whether the properties of the outer regions of the Local Group large spirals are typical. Here, we present the first panoramic view of a spiral galaxy beyond the Local Group, based on the largest, contiguous, ground-based imaging survey to date resolving the stellar halo of the nearest prime analog of the Milky Way, NGC 891 (D {approx} 10 Mpc). The low surface brightness outskirts of this galaxy are populated by multiple, coherent, and vast substructures over the {approx}90 kpc x 90 kpc extent of the survey. These include a giant stream, the first to be resolved into stars beyond the Local Group using ground-based facilities, that loops around the parent galaxy up to distances of {approx}50 kpc. The bulge and the disk of the galaxy are found to be surrounded by a previously undetected large, flat, and thick cocoon-like stellar structure at vertical and radial distances of up to {approx}15 kpc and {approx}40 kpc, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Optical homodyne detection in view of the joint probability distribution

Optical homodyne detection is examined in view of the joint probability distribution. The usual view is that the relative phase between independent laser fields is localized by photon-number measurements in interference experiments such as homodyne detection. This is why operationally coherent states for laser fields are used in the description of homodyne detection and optical quantum-state tomography. Here, we elucidate these situations by considering the joint probability distribution and the invariance of homodyne detection under the phase transformation of optical fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards Full Field-of-View Fourier Ptychography for Extreme Ultraviolet Microscope

We evaluate various Fourier ptychographic microscopy (FPM) reconstruction algorithms using both simulated and experimental data acquired from an Extreme Ultraviolet (EUV, 13.5 nm wavelength) microscope. We specifically focus on the algorithms' ability to robustly address field-dependent aberrations, which enables increased spatial resolution and quantitative phase imaging across an expanded field of view. We systematically compare the algorithms' performance under aberrations for a single zoneplate imaging system, utilizing Fourier Ring Correlation (FRC) as a systematic metric for assessing reconstruction quality. Furthermore, we explore the impact of systematic errors on the reconstruction of experimental data, aiming to increase the effective field of view by 25-fold, from the nominal 5x5 um2 diffraction-limited area. Additionally, our evaluation incorporates innovative FPM-adjacent methodologies, including the Angular Ptychographic Imaging with Closed-form method (APIC), for reconstructing EUV images.

Gu, Chaoying↗

Single-view 3D reconstruction of correlated gamma-neutron sources

We describe a new method of 3D image reconstruction of neutron sources that emit correlated gammas (e.g. Cf- 252, Am-Be). This category includes a vast majority of neutron sources important in nuclear threat search, safeguards and non-proliferation. Rather than requiring multiple views of the source this technique relies on the source’s intrinsic property of coincidence gamma and neutron emission. As a result only a single-view measurement of the source is required to perform the 3D reconstruction. In principle, any scatter camera sensitive to gammas and neutrons with adequate timing and interaction location resolution can perform this reconstruction. Using a neutron double scatter technique, we can calculate a conical surface of possible source locations. By including the time to a correlated gamma we further constrain the source location in three-dimensions by solving for the source-to-detector distance along the surface of said cone. As a proof of concept we applied these reconstruction techniques on measurements taken with the the Mobile Imager of Neutrons for Emergency Responders (MINER). Two Cf-252 sources measured at 50 and 60 cm from the center of the detector were resolved in their varying depth with average radial distance relative resolution of 26%. To demonstrate the technique’s potential with an optimized system we simulated the measurement in MCNPX-PoliMi assuming timing resolution of 200 ps (from 2 ns in the current system) and source interaction location resolution of 5 mm (from 3 cm). Furthermore, these simulated improvements in scatter camera performance resulted in radial distance relative resolution decreasing to an average of 11%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

View-Dependent Streamline Deformation and Exploration

Occlusion presents a major challenge in visualizing 3D flow and tensor fields using streamlines. Displaying too many streamlines creates a dense visualization filled with occluded structures, but displaying too few streams risks losing important features. We propose a new streamline exploration approach by visually manipulating the cluttered streamlines by pulling visible layers apart and revealing the hidden structures underneath. Here this paper presents a customized view-dependent deformation algorithm and an interactive visualization tool to minimize visual cluttering for visualizing 3D vector and tensor fields. The algorithm is able to maintain the overall integrity of the fields and expose previously hidden structures. Our system supports both mouse and direct-touch interactions to manipulate the viewing perspectives and visualize the streamlines in depth. By using a lens metaphor of different shapes to select the transition zone of the targeted area interactively, the users can move their focus and examine the vector or tensor field freely.

97 MATHEMATICS AND COMPUTING↗

Wide-Field-of-View Millimeter-Wave Telescope Design with Ultra-Low Cross-Polarization

As millimeter-wave arrays become available, off-axis imaging performance of the fore optics increases in importance due to the relatively large physical extent of the arrays. Typically, simple optical telescope designs are adapted to millimeter-wave imaging but single-mirror spherical or classic conic designs cannot deliver adequate image quality except near the optical axis. Since most millimeter-wave designs are quasi-optical, optical ray tracing and commercial design software can be used to optimize designs to improve off-axis imaging as well as minimize cross-polarization. Methods that obey the Dragone-Mizuguchi condition for the design of reflective millimeter-wave telescopes with low cross-polarization also provide additional degrees of freedom that offer larger fields of view than possible with single-reflector designs. Dragone’s graphical design method does not lend itself readily to computer-based optical design approaches, but subsequent authors expanded on Dragone’s geometric design approach with analytic expressions that describe the location, shape, off-axis height and tilt of the telescope elements that satisfy Dragone’s design rules and can be used as a first-order design for subsequent computer-based design and optimization. We investigate two design variants that obey the Dragone-Mizuguchi conditions that exhibit ultra-low polarization crosstalk and a large diffraction-limited field of view well suited to millimeter-wave imaging arrays.

Millimeter-Wave Optical Design↗

Characterization of masses in digital breast tomosynthesis: Comparison of machine learning in projection views and reconstructed slices

Purpose: In digital breast tomosynthesis (DBT), quasi-three-dimensional (3D) structural information is reconstructed from a small number of 2D projection view (PV) mammograms acquired over a limited angular range. The authors developed preliminary computer-aided diagnosis (CADx) methods for classification of malignant and benign masses and compared the effectiveness of analyzing lesion characteristics in the reconstructed DBT slices and in the PVs. Methods: A data set of MLO view DBT of 99 patients containing 107 masses (56 malignant and 51 benign) was collected at the Massachusetts General Hospital with IRB approval. The DBTs were obtained with a GE prototype system which acquired 11 PVs over a 50 deg. arc. The authors reconstructed the DBTs at 1 mm slice interval using a simultaneous algebraic reconstruction technique. The region of interest (ROI) containing the mass was marked by a radiologist in the DBT volume and the corresponding ROIs on the PVs were derived based on the imaging geometry. The subsequent processes were fully automated. For classification of masses using the DBT-slice approach, the mass on each slice was segmented by an active contour model initialized with adaptive k-means clustering. A spiculation likelihood map was generated by analysis of the gradient directions around the mass margin and spiculation features were extracted from the map. The rubber band straightening transform (RBST) was applied to a band of pixels around the segmented mass boundary. The RBST image was enhanced by Sobel filtering in the horizontal and vertical directions, from which run-length statistics texture features were extracted. Morphological features including those from the normalized radial length were designed to describe the mass shape. A feature space composed of the spiculation features, texture features, and morphological features extracted from the central slice alone and seven feature spaces obtained by averaging the corresponding features from three to 19 slices centered at the central slice were compared. For classification of masses using the PV approach, a feature extraction process similar to that described above for the DBT approach was performed on the ROIs from the individual PVs. Six feature spaces obtained from the central PV alone and by averaging the corresponding features from three to 11 PVs were formed. In each feature space for either the DBT-slice or the PV approach, a linear discriminant analysis classifier with stepwise feature selection was trained and tested using a two-loop leave-one-case-out resampling procedure. Simplex optimization was used to guide feature selection automatically within the training set in each leave-one-case-out cycle. The performance of the classifiers was evaluated by the area (A{sub z}) under the receiver operating characteristic curve. Results: The test A{sub z} values from the DBT-slice approach ranged from 0.87{+-}0.03 to 0.93{+-}0.02, while those from the PV approach ranged from 0.78{+-}0.04 to 0.84{+-}0.04. The highest test A{sub z} of 0.93{+-}0.02 from the nine-DBT-slice feature space was significantly (p=0.006) better than the highest test A{sub z} of 0.84{+-}0.04 from the nine-PV feature space. Conclusion: The features of breast lesions extracted from the DBT slices consistently provided higher classification accuracy than those extracted from the PV images.

60 APPLIED LIFE SCIENCES↗

An opposite view data replacement approach for reducing artifacts due to metallic dental objects

Purpose: To present a conceptually new method for metal artifact reduction (MAR) that can be used on patients with multiple objects within the scan plane that are also of small sized along the longitudinal (scanning) direction, such as dental fillings. Methods: The proposed algorithm, named opposite view replacement, achieves MAR by first detecting the projection data affected by metal objects and then replacing the affected projections by the corresponding opposite view projections, which are not affected by metal objects. The authors also applied a fading process to avoid producing any discontinuities in the boundary of the affected projection areas in the sinogram. A skull phantom with and without a variety of dental metal inserts was made to extract the performance metric of the algorithm. A head and neck case, typical of IMRT planning, was also tested. Results: The reconstructed CT images based on this new replacement scheme show a significant improvement in image quality for patients with metallic dental objects compared to the MAR algorithms based on the interpolation scheme. For the phantom, the authors showed that the artifact reduction algorithm can efficiently recover the CT numbers in the area next to the metallic objects. Conclusions: The authors presented a new and efficient method for artifact reduction due to multiple small metallic objects. The obtained results from phantoms and clinical cases fully validate the proposed approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery

Purpose: In external-beam radiation therapy, existing on-board x-ray imaging chains orthogonal to the delivery beam cannot recover 3D target trajectories from a single view in real-time. This limits their utility for real-time motion management concurrent with beam delivery. To address this limitation, the authors propose a novel concept for on-board imaging based on the inverse-geometry Scanning-Beam Digital X-ray (SBDX) system and evaluate its feasibility for single-view 3D intradelivery fiducial tracking. Methods: A chest phantom comprising a posterior wall, a central lung volume, and an anterior wall was constructed. Two fiducials were placed along the mediastinal ridge between the lung cavities: a 1.5 mm diameter steel sphere superiorly and a gold cylinder (2.6 mm length x 0.9 mm diameter) inferiorly. The phantom was placed on a linear motion stage that moved sinusoidally. Fiducial motion was along the source-detector (z) axis of the SBDX system with {+-}10 mm amplitude and a programmed period of either 3.5 s or 5 s. The SBDX system was operated at 15 frames per second, 100 kVp, providing good apparent conspicuity of the fiducials. With the stage moving, detector data were acquired and subsequently reconstructed into 15 planes with a 12 mm plane-to-plane spacing using digital tomosynthesis. A tracking algorithm was applied to the image planes for each temporal frame to determine the position of each fiducial in (x,y,z)-space versus time. A 3D time-sinusoidal motion model was fit to the measured 3D coordinates and root mean square (RMS) deviations about the fitted trajectory were calculated. Results: Tracked motion was sinusoidal and primarily along the source-detector (z) axis. The RMS deviation of the tracked z-coordinate ranged from 0.53 to 0.71 mm. The motion amplitude derived from the model fit agreed with the programmed amplitude to within 0.28 mm for the steel sphere and within -0.77 mm for the gold seed. The model fit periods agreed with the programmed periods to within 7%. Conclusions: Three dimensional fiducial tracking with approximately 1 mm or better accuracy and precision appears to be feasible with SBDX, supporting its use to guide radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a constrained paired-view technique in iterative reconstruction for breast tomosynthesis

Purpose: The order in which the projection views are employed in the reconstruction of tomosynthesis by iterative algorithms, such as simultaneous algebraic reconstruction technique and maximum likelihood, has a strong effect on the rate of convergence, accuracy, and the edge-blurring artifacts in the reconstructed image. The purpose of this investigation was to characterize and evaluate the effects of ordering schemes on image quality for breast tomosynthesis reconstruction and to explore a new constrained paired-view technique that could provide reduction of reconstruction artifacts. In this work, the authors compared several different ordering schemes and characterized the image quality and the formation of out-of-plane artifacts. Furthermore, a new normalization method is presented. It produces more accurate reconstructions with reduced artifacts comparing to the standard method of sequential ordering.Methods: In addition to visual assessment of image quality, several indices such as the signal-difference-to-noise ratio, the artifact-spread function, and the lesion detectability (d{sup ′}) were computed to quantitatively evaluate the effect of ordering scheme. The sets of breast tomosynthesis projection images were simulated for reconstruction; one set had uniform background (white noise only) and the other two contained both anatomic background and quantum noise. Clinical breast images were also studied for comparison.Results: The authors have quantified the image quality in reconstructed slices for a range of tumor sizes. The authors’ proposed method provides better performance for all of the metrics tested (contrast, d{sup ′}, and the level of artifacts) both for the uniform phantom case and in the presence of anatomical structure.Conclusions: The paired projection normalization provides better performance in the image quality of the reconstructed slices, and results in a lower level of artifacts in the Z direction. This implies that even a relatively simple method like the “side-to-side” sequence, which pairs two symmetrical projections with equal angular distance from the central projection, would achieve better reconstructed image quality than the conventional “step-by-step” method, which uses sequential projections one after another.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multichannel response analysis on 2D projection views for detection of clustered microcalcifications in digital breast tomosynthesis

Purpose: To investigate the feasibility of a new two-dimensional (2D) multichannel response (MCR) analysis approach for the detection of clustered microcalcifications (MCs) in digital breast tomosynthesis (DBT). Methods: With IRB approval and informed consent, a data set of two-view DBTs from 42 breasts containing biopsy-proven MC clusters was collected in this study. The authors developed a 2D approach for MC detection using projection view (PV) images rather than the reconstructed three-dimensional (3D) DBT volume. Signal-to-noise ratio (SNR) enhancement processing was first applied to each PV to enhance the potential MCs. The locations of MC candidates were then identified with iterative thresholding. The individual MCs were decomposed with Hermite–Gaussian (HG) and Laguerre–Gaussian (LG) basis functions and the channelized Hotelling model was trained to produce the MCRs for each MC on the 2D images. The MCRs from the PVs were fused in 3D by a coincidence counting method that backprojects the MC candidates on the PVs and traces the coincidence of their ray paths in 3D. The 3D MCR was used to differentiate the true MCs from false positives (FPs). Finally a dynamic clustering method was used to identify the potential MC clusters in the DBT volume based on the fact that true MCs of clinical significance appear in clusters. Using two-fold cross validation, the performance of the 3D MCR for classification of true and false MCs was estimated by the area under the receiver operating characteristic (ROC) curve and the overall performance of the MCR approach for detection of clustered MCs was assessed by free response receiver operating characteristic (FROC) analysis. Results: When the HG basis function was used for MCR analysis, the detection of MC cluster achieved case-based test sensitivities of 80% and 90% at the average FP rates of 0.65 and 1.55 FPs per DBT volume, respectively. With LG basis function, the average FP rates were 0.62 and 1.57 per DBT volume at the same sensitivity levels. The difference in the two sets of basis functions for detection of MCs did not show statistical significance. Conclusions: The authors' experimental results indicate that the MCR approach is promising for the detection of MCs on PV images. The HG or LG basis functions are both effective in characterizing the signal response of MCs using the channelized Hotelling model. The coincidence counting method for fusion of the 2D MCR in 3D is an important step for FP reduction. Further study is underway to improve the MCR approach for microcalcification detection in DBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗