Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter↗

Field demonstration and implementation analysis of model predictive control in an office HVAC system

Model Predictive Control (MPC) is a promising technique to address growing needs for heating, ventilation, and air-conditioning (HVAC) systems to operate more efficiently and with greater flexibility. However, due to a number of factors, including the required implementation expertise, lack of high quality data, and a risk-adverse industry, MPC has yet to gain widespread adoption. While many previous studies have shown the advantages of MPC, few analyzed the implementation effort and associated practical challenges. In addition, previous work has developed an open-source, Modelica-based tool-chain that automatically generates optimal control, parameter estimation, and state estimation problems aimed at facilitating MPC implementation. Therefore, this study demonstrates usage of this tool-chain to implement MPC in a real office building, discusses practical challenges of implementing MPC, and estimates the implementation effort associated with various tasks in order to inform the development of future workflows and serve as an initial benchmark for their impact on reducing implementation effort. This study finds that the implemented MPC saves approximately 40% of HVAC energy over the existing control during a two-month trial period and that tasks related to data collection and controller deployment activities can each require as much effort as model generation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A low-cost centralized HVAC control system solution for energy savings, load shedding, and improved maintenance

University campuses rely on centralized controls for managing and optimizing complex HVAC systems in larger buildings. However, most campuses also have many smaller buildings with packaged HVAC systems controlled by a stand-alone thermostat. Even when these distributed and often overlooked systems have modern programmable thermostats, they cannot be centrally monitored or controlled, and they are typically not programmed adequately. This paper describes the implementation of a low-cost centralized control solution for these systems serving smaller campus buildings, mostly under 5,000 sf and representative of light commercial spaces. Thanks to advances in technology spurred by residential and commercial IoT developments, simple networked thermostat solutions exist that can easily replace original thermostats, and, connect these systems to a web-based portal for monitoring and control. We show that, with small customizations, these platforms can be integrated into facility management workflows. Beyond the energy savings potential from improved scheduling and closer management of these systems, there are significant advantages for maintenance crews since these systems can now be monitored on smart phones or tablets. A grid-responsive load-shedding program has also been implemented for additional cost savings. The networked thermostats can also be connected to additional systems such as economizer controls for improved ventilation management and energy savings. With data from these systems integrated centrally, it can also be used for improved analytics and fault detection. A toolkit has been developed to share the program with other campuses, whether for energy savings, improved management of ventilation, or a more proactive maintenance approach.

Fauchier-Magnan, Nicolas↗

A Flexible and Generic Functional Mock-up Unit Based Threat Injection Framework for Grid-interactive Efficient Buildings: A Case Study in Modelica

Grid-interactive efficient buildings (GEBs) have been considered as an important asset to support the power grid reliability by utilizing the demand flexibility offered by GEBs. GEBs are enabled by advances in sensors and controls, and the communication between building equipment, whole buildings, and the grid. The integration of different building technologies and network-based communication system makes GEBs vulnerable to passive threats such as equipment failure and active threats such as cyber-attacks. Modeling and simulation is an effective way to evaluate the impact of threats on the system performance. This paper proposes a generic and flexible threat injection framework for commonly-used building energy simulators such as EnergyPlus and Modelica to support threat modeling and evaluation. This framework leverages functional mock-up unit (FMU) to develop a general modeling interface for threat injection and simulation. A numerical case study using Modelica as a building energy simulator is conducted to demonstrate the capability of the framework for supporting single/multiple-order threat modeling and simulation of a GEB. Four threats and their combinations are injected on a Modelica-based threat-free building energy and control system, including operating supply fan at its full speed, remotely cycling the chiller on and off, blocking the chiller from receiving the chilled water supply temperature setpoints, and hijacking the global zone air temperature setpoint. Simulation results show that the cyber-attack that leads to short-term signal blocking has small effects on the system operation due to the "self-healing" feature of the heating, ventilation, and air-conditioning (HVAC) interactive control system. The threat that takes control of resetting the global zone air temperature setpoints has the most adverse impact on the system energy use, peak power demand, thermal comfort and the provision of demand flexibility. The combination of four threats have aggregative effects on the system but the effects are less than the additive effects of the individual threat.

Fu, Yanyang↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transparent window film with embedded nano-shades for thermoregulation

Every year, more than 20% of the energy consumption in the United States and more than 10% of the global consumption is used towards HVAC (Heating, Ventilating, Air-Conditioning) systems in buildings. Although continued efforts in advancing renewable energy, efficient appliances, and smart building systems are desired, the most critical factors that cause extensive indoor energy consumption are thermal leakage and thermal waste generation. We demonstrate a smart window film that allows natural lighting with a clear view while blocking oblique incident sunlight to make the building interior cooler without using electricity or generating heat. Building upon the concept of, often overlooked, traditional window shades and privacy window films, we emphasize and elevate the application and impact of using magnetically arranged nanoscale material for energy conservation purpose in buildings. By embedding vertically aligned Ni flakes (VANF) in a polymer matrix film, nanoscale mirror array serve as shades to block the high-angled incident sunlight, blocking approximately 73% of total solar irradiance and bringing down the indoor temperature by 1.92 °C during the daytime in a model house while providing nearly 90% transparency. Global application was simulated by applying the respective solar angle and intensity at selected latitudes, indicating their potential. This passively energy-conserving smart film is a low cost, maintenance free, and simple product for users and easy-to-manufacture product for the industry.

36 MATERIALS SCIENCE↗

A neural-network-enhanced parameter-varying framework for multi-objective model predictive control applied to buildings

Management of the electrical grid is becoming more complex due to the increased penetration of alternative energy generation technologies and a broadening diversity of electric loads. This complexity creates challenges in balancing demand and generation that can increase the potential for grid instabilities. One effective way to address this issue is to leverage previously unexploited demand flexibility through advanced control strategies. In this work, we propose an advanced control method, called adaptive neural parameter-varying model predictive control (ANPV-MPC), to control the temperature and energy consumption of a building via its Heating, Ventilation, and Air Conditioning system. ANPV-MPC combines key ideas in parameter-varying control, adaptive control, and online learning strategies to bridge the gap between computationally efficient linear model predictive control and more accurate nonlinear model predictive control. The novelty in ANPV-MPC is the use of a physics-inspired Bayesian neural network to estimate the coefficients of the parameter-varying linear control model. The Bayesian neural network additionally provides uncertainty estimates, triggering online training to capture evolving building system conditions. We show that ANPV-MPC can approximate the building system dynamics with a 28.39% higher accuracy than traditional linear model predictive control, resulting in 36.23% better control performance without increasing complexity of the optimal control problem. ANPV-MPC also adapts in real time to previously unseen conditions using online learning, further improving its performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of cooling setpoint setback savings in commercial buildings using electricity and exterior temperature time series data

Commercial buildings account for a significant amount of total energy produced in the US, and the Heating Ventilation and Cooling (HVAC) systems are one of the most significant components of their overall consumption. In this study, we proposed a new data-driven approach to evaluate HVAC cooling systems in commercial buildings and identify savings opportunities. The focus is an investigation of the impact of thermostat setpoint setback but using only whole building, electricity data taken at 15-min intervals for the analysis. We conducted a comparative study of setpoint setback characteristics on 432 commercial buildings with 5 building usage types across the United States. To accomplish this, both piecewise and Random Forest regression algorithms were employed using electricity and exterior temperature datasets to identify operational characteristics and the effective setpoints in the building to determine the corresponding savings opportunities. Both occupied and unoccupied time periods were studied across cooling degree days (CDD), when air conditioning is typically operational. Here the results show that in commercial buildings, on average, cooling systems account for 9.5% of total consumption. When a one degree setback during the cooling season is applied, an average of approximately 1.1% of annual consumption is achieved; retail and office buildings demonstrate the highest potential for savings. Additionally, we identified that the number of cooling degree days and base to peak ratio (BPR) are the most important variables for predicting the magnitude of the consumption of cooling systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Peak Power Minimization for Commercial Thermostatically Controlled Loads in Multi-Unit Grid-Interactive Efficient Buildings

The load profiles of most commercial and industrial consumers are characterized by brief periods of very high power consumption followed by intervals of lower demand. To encourage such consumers to flatten their load profiles, power utilities in and around the world often levy a monthly demand charge (DC) on the peak demand measured over brief intervals. In this work, we consider the joint optimization of energy costs (EC) and the instantaneous peak power of a multi-unit building which uses a hydronic heating, ventilation and cooling (HVAC) system and responds to a demand response (DR) program. Despite the non-linear structure of the problem, we show how optimal solutions can be obtained efficiently using linear programming. Next, we study the power demand patterns resulting from our proposed strategy for thermostatically controlled loads (TCLs), and evaluate the strategy’s performance for various climate zones in the US, under both typical and atypical weather conditions. Finally, the results show that depending on the ambient conditions and the tariff structure, our strategy can result in utility bill savings of up to nearly 19% compared to the baseline. The results also indicate that our power control strategy can significantly reduce the instantaneous peak power consumption in commercial TCLs.

HVAC↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Exposures to Airborne Particles Through Improved Filtration: A High-Level Modeling Analysis

Indoor airborne particulates are well-known health hazards and filtration is one common method of reducing exposures. Based on our previously developed Regional Shelter Analysis methodology and parameters that characterize the existing US building stock, we perform a high-level assessment of the potential benefits of upgrading existing filters in furnace and in heating, ventilation, and air conditioning systems using off-the-shelf filters. We use three metrics to assess the improvement: Building Transmission Factor (a measure of protection against outdoor airborne particles), Indoor Normalized Time and Space Integrated Air Concentration (a measure of indoor exposure to indoor-origin airborne particles), and Building Exit Fraction (fraction of indoor airborne particles that are released to the outdoor atmosphere). We also discuss the potential reduction in regional exposures due to particles exiting the building and exposing downwind building occupants. Our modeling indicates that while buildings provide their occupants passive protection against airborne particulate hazards, including but not limited to PM 2.5 , PM 10 , and wildfire smoke; improving particle filtration efficiency may further improve this protection. The degree of improvement varies with particle size and building type. Of the building types studied, apartments are predicted to benefit most, with greater than a factor of 2 improvement (≥50% reduction in exposures) for 1 µm particle exposures when using MERV 7 to 12 rated filters. Non-residential buildings were notably less responsive to improved filtration but had the highest Building Exit Fractions with 30% to 40% of indoor airborne particles released to the outdoor atmosphere (apartment buildings only released 6% to 9%). Improvements predicted for single family homes were intermediate between apartments and non-residential buildings. Improvements in the Regional Exposure metric are larger, ranging from a factor of 2.5x to 10x for residences (when using MERV 7 to 12 rated filters) and up to 25x for large apartments with MERV 14 or 15 rated filters. The results of our modeling analysis are broadly consistent with the limited experimental data and modeling results available in the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Optimizing HVAC Operations in Multi-unit Buildings for Grid Demand Response

The thermal inertia of buildings, along with the flexibility associated with thermostatically controlled loads (TCL) allows heating ventilation and cooling (HVAC) systems to be used for grid demand response (DR). In this work, we consider an HVAC system that serves multiple units in a residential building to meet their space heating requirements. We aim to determine the optimal power flow to each unit that minimizes the power costs incurred by the building's occupants while keeping in consideration their thermal comfort. The DR program is assumed to allow the building temperatures to deviate from the set-points up to a maximum limit. Despite the complex, non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using quadratic programming. Since HVAC systems can run on either electricity or natural gas, we study the efficacy of the DR regime for both hourly electricity prices and flat gas prices over the course of 24 hours. Finally, we run simulations to determine the optimal thermal power and the evolution of unit temperatures for various energy pricing schemes.

Naqvi, Syed A.↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Low Carbon Technology Strategies: Midrise Apartment

This document includes steps that building owners and operators can implement to achieve smart, healthy, and low-carbon midrise apartment buildings within their existing building portfolios. Midrise apartments may use packaged rooftop units for heating, cooling, and ventilation or central plant systems for larger buildings.

analytics↗

Energy Savings With Acceptable Indoor Air Quality Through Improved Airflow Control in Residential Retrofits

The Partnership for Advanced Residential Retrofit (PARR) has been a U.S. Department of Energy (DOE) Building America team since 2009, with a primary focus on upgrading the performance of existing buildings to reduce energy loads. In this project, PARR’s work explored the integration of airflow-focused measures in residential retrofit homes with the goal to maximize energy savings while ensuring acceptable indoor air quality (IAQ) using a systems approach to controlling four contributing air streams: • Building air leakage (natural, uncontrolled infiltration), • Forced-air distribution system static pressure and airflow rate, • Distribution system duct leakage, and • Mechanical ventilation. This project addressed airflows in houses, their combined impact on energy use and IAQ, and the comparative effects of typical insulation and air sealing practices versus integrated system-level retrofits. Additionally, practical considerations for contractors taking either approach were addressed. Finally, the effects of supply ventilation and exhaust ventilation on IAQ were compared in occupied homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗