Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ULTRAVIOLET FILTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Simple Refractometers for Index Measurements by Minimum Deviation Method from Far-ultraviolet to Near Infrared

The focal shift of an optical filter used in non-collimated light depends directly on substrate thickness and index of refraction. The HST Advanced Camera for Surveys (ACS) requires a set of filters whose focal shifts are tightly matched. Knowing the index of refraction for substrate glasses allows precise substrate thicknesses to be specified. Two refractometers have been developed at the Goddard Space Flight Center (GSFC) to determine the indices of refraction of materials from which ACS filters are made. Modem imaging detectors for the near infrared, visible, and far ultraviolet spectral regions make these simple yet sophisticated refractometers possible. A new technology, high accuracy, angular encoder also developed at GSFC makes high precision index measurement possible in the vacuum ultraviolet.

Leviton, Douglas B.↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a fast radiation detector based on barium fluoride scintillation crystal

Barium fluoride (BaF{sub 2}) is an inorganic scintillation material used for the detection of X/gamma radiation due to its relatively high density, equivalent atomic number, radiation hardness, and high luminescence. BaF{sub 2} has a potential capacity to be used in gamma ray timing experiments due to the prompt decay emission components. It is known that the light output from BaF{sub 2} has three decay components: two prompt of those at approximately 195 nm and 220 nm with a decay constant around 600-800 ps and a more intense, slow component at approximately 310 nm with a decay constant around 630 ns which hinders fast timing experiments. We report here the development of a fast radiation detector based on a BaF{sub 2} scintillation crystal employing a special optical filter device, a multiple reflection multi-path ultraviolet region short-wavelength pass light guides (MRMP-short pass filter) by using selective reflection technique, for which the intensity of the slow component is reduced to less than 1%. The methods used for this study provide a novel way to design radiation detector by utilizing scintillation crystal with several emission bands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Si quantum dots in silicon nitride: Quantum confinement and defects

Luminescence of amorphous Si quantum dots (Si QDs) in a hydrogenated silicon nitride (SiN{sub x}:H) matrix was examined over a broad range of stoichiometries from Si{sub 3}N{sub 2.08} to Si{sub 3}N{sub 4.14}, to optimize light emission. Plasma-enhanced chemical vapor deposition was used to deposit hydrogenated SiN{sub x} films with excess Si on Si (001) substrates, with stoichiometry controlled by variation of the gas flow rates of SiH{sub 4} and NH{sub 3} gases. The compositional and optical properties were analyzed by Rutherford backscattering spectroscopy, elastic recoil detection, spectroscopic ellipsometry, photoluminescence (PL), time-resolved PL, and energy-filtered transmission electron microscopy. Ultraviolet-laser-excited PL spectra show multiple emission bands from 400 nm (3.1 eV) to 850 nm (1.45 eV) for different Si{sub 3}N{sub x} compositions. There is a red-shift of the measured peaks from ∼2.3 eV to ∼1.45 eV as Si content increases, which provides evidence for quantum confinement. Higher N content samples show additional peaks in their PL spectra at higher energies, which we attribute to defects. We observed three different ranges of composition where Tauc band gaps, PL, and PL lifetimes change systematically. There is an interesting interplay of defect luminescence and, possibly, small Si QD luminescence observed in the intermediate range of compositions (∼Si{sub 3}N{sub 3.15}) in which the maximum of light emission is observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isolating Weakly and Strongly-Absorbing Classes of Carbonaceous Aerosol: Optical Properties, Abundance and Lifecycle

The goal of this project was to evaluate climate-relevant properties of carbonaceous particles and the transformations of those particles in the atmosphere, with the purpose of developing lumped classes of carbonaceous particles suitable for use in large-scale models. These climate-relevant properties included light absorption and hygroscopicity. Hygroscopicity is a measure of water affinity, which governs particle growth at humid conditions and absorption and scattering under those conditions. It also controls particles’ activation into cloud droplets, which in turn affects cloud albedo and particle removal. This project used laboratory measurements of fresh and aged carbonaceous aerosol, and predictions of properties using a particle-resolved model, to identify sensitivities. The focus in this project was on aerosol from biomass pyrolysis, abbreviated BrC (“brown carbon”). We measured absorption by aerosol from biomass pyrolysis from two sources with very different composition: wood and corn stalk. For both sources, the greatest light absorption occurred at the highest generation temperature, and this maximum absorption was very similar to that of wood-generated aerosol. We suggest that pyrolysis products can be considered surrogates for a wide range of biomass aerosol. We captured aerosol emitted from biomass pyrolysis on filters and exposed it to ultraviolet radiation, to the atmospheric trace gases ozone, ammonia (NH 3 ) and nitrogen oxide; and to aqueous saturated salt solutions of ammonium sulfate, ammonium nitrate, sodium chloride and sodium sulfate. Absorption increased, but by only small amounts for all of these treatments, with one exception: after aging with ammonia, absorption increased by almost a factor of four. Absorption increased more at visible wavelengths. We confirmed that a significant change occurred in the aerosol phase, by measuring absorption by suspended particles after aging with NH 3 and finding doubled aerosol absorption. Aging by NH 3 produces a mild increase in the hygroscopicity of BrC, and a greater increase in cloud condensation nucleus activity. Therefore, reactions with NH 3 form compounds that absorb more light than the original aerosol and act as surfactants, increasing the likelihood that these particles will participate in cloud formation. The particle-resolved model PartMC was enhanced to include additional physical processes. It was calibrated against chamber results, and we needed to account for the non-spherical structure of particle agglomerates, even for ammonium sulfate. We implemented the “volatility basis set” (VBS) framework in the model. The updated PartMC-MOSAIC model was able to simulate gas and aerosol concentrations from the CARES campaign at levels similar to observations. The PartMC model was used to evaluate plume dynamics affecting CCN activity of biomass burning aerosols early in a plume. Coagulation limits emission of CCN to about 1016 per kg of fuel. Co-emitted, semi-volatile organic compounds or emission at small particle sizes can homogenize composition before plume exit, and SVOC co-emission can be the main factor determining plume-exit CCN for hydrophobic or small particles. When externally-mixed, accumulation-mode particles are emitted in the absence of SVOCs, CCN can be overestimated by up to a factor of two. This means that measurements made on aerosol from all phases of combustion gathered into a single chamber may incorrectly estimate CCN properties. Based on the findings here, we make some recommendations for use in large-scale models: (1) inventories should represent “internally” versus “externally” mixed under certain combustion conditions; (2) consideration of non-spherical particles when coagulation is important for climate-relevant properties near sources; (3) designating organic biomass particles as weakly absorbing; (4) “inherent absorption” and hygroscopicity are not altered with aging by ozone or ultraviolet light, and inherent absorption is not altered with salt addition, but both cloud activity and absorption are altered by aging with ammonia and could require a separate class in large-scale models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NEW HIGH- z FERMI BL LACS WITH THE PHOTOMETRIC DROPOUT TECHNIQUE

Determining redshifts for BL Lacertae (BL Lac) objects using the traditional spectroscopic method is challenging due to the absence of strong emission lines in their optical spectra. We employ the photometric dropout technique to determine redshifts for this class of blazars using the combined 13 broadband filters from Swift -UVOT and the multi-channel imager GROND at the MPG 2.2 m telescope at ESO's La Silla Observatory. The wavelength range covered by these 13 filters extends from far-ultraviolet to the near-infrared. We report results on 40 new Fermi- detected BL Lacs with the photometric redshift determinations for five sources, with 3FGL J1918.2–4110 being the most distant in our sample at z = 2.16. Reliable upper limits are provided for 20 sources in this sample. Using the highest energy photons for these Fermi -LAT sources, we evaluate the consistency with the gamma-ray horizon due to the extragalactic background light.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved protection for silicon solar cells

Fluorinated ethylene propylene /FEP/ film is substituted for epoxy cement in bonding glass covers to silicon solar cells. Insensitivity of FEP to ultraviolet radiation reduces requirement for filtering and does not impair cell performance. Cell costs are reduced and cover mounting is simplified.

Broder, J. D.↗

The intrinsic linear polarization of 53 Camelopardalis and alpha 2 Canum Venaticorum

The intrinsic phase-dependent linear polarization of two magnetic Ap stars is studied. The polarization characteristics in a broad blue filter band and in the ultraviolet are outlined, and the mechanisms of polarization are examined. The blue band polarization of 53 Cam (corrected by removing the stellar component) is found to be compatible with an oblique rotator whose angular parameters are in essential agreement with those deduced by Landstreet (1970) and by Huchra (1972).

Kemp, J. C.↗

Comet Bowell 1980b

Optical filter photometry, and optical and ultraviolet spectrophotometry data collected between November 1980 and June 1982 of Comet Bowell are presented. It was determined that Comet Bowell began producing significant amounts of OH, though not other species, before perihelion at a heliocentric distance near 4.6 AU. As the comet approached perihelion at 3.4 AU, OH production decreased and CN and C2 species were detected at normal concentrations. An outburst in April 1982 was dominated by OH. The grains in 1982 near perihelion showed increases in albedo between 3150 and 4500 A and 1.2 and 1.6 microns. The presence of two grains populations was suggested, together with the conclusion that Comet Bowell was physically a typical new comet entering the inner solar system from the Oort cloud for the first time.

Feldman, P. D.↗

An improved rocket ozonesonde (ROCOZ-A). II - Preparation of stratospheric ozone profiles

The ROCOZ-A radiometer measures ozone by long pathlength photometry in the stratosphere and lower mesosphere. After a rocket launch to an apogee of 70 km, the instrument measures the solar ultraviolet irradiance over its four filter wavelengths as it descends on a parachute. The fundamental values from ROCOZ-A are ozone overburdens versus radar altitude from 53 to 20 km. The slope of these values gives ozone number density. At one standard deviation the repeatability of the ozone overburden measurements averages 2.4 percent. For ozone number density the repeatability averages 3.2 percent with a significant increase at altitudes below the ozone number density maximum. The accuracy limits for overburden and number density are estimated at 5-7 percent. With auxiliary measurements of pressure and temperature, ozone results are also produced in terms of ozone mixing ratio, albeit with a slight broadening of the estimated accuracy limits. The vertical response of ROCOZ-A ozone measurements (full width at half maximum) is 4 km. The assembly of ROCOZ-A profiles can be used to compare with measurements from each of the current NASA and NOAA satellite ozone instruments. In addition, the repeatability of ROCOZ-A allows the use of this instrument as a transfer standard between satellite instruments with different fundamental ozone measurements.

Barnes, Robert A.↗

Dynamics Explorer 1 SOI images of the Antarctic ozone hole

The Dynamics Explorer (DE) satellite carries an Auroral Imaging Package which contains filters designed for performing backscatter ultraviolet measurements to measure total column ozone in the Earth's middle and lower atmosphere. Measurements are obtained at 317.5 mm (to measure ozone absorption) and 360 nm (to measure scene reflectivity). In October 1985 and 1986, measurements were obtained near apogee of the Antarctic ozone hole. The only other high spatial resolution measurements were obtained from the Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) experiment. In October 1987, the Dynamics Explorer apogee had precessed into the Northern Hemisphere preventing measurements of the ozone hole. However, measurements should be obtained from DE of the ozone hole in both 1988 and 1989. Considering that the Nimbus 7 TOMS instrument has long exceeded its expected lifetime, the DE Spin Scan Ozone Imager (SOI) experiment could easily play a crucial role in studies of the ozone hole over the next few years.

Keating, G. M.↗

Thin aluminum filters for use on the Apollo Telescope Mount XUV spectrographs

Thin, unbacked, aluminum film filters were used on two extreme ultraviolet (XUV) instruments flown on the Apollo Telescope Mount of Skylab by the Naval Research Laboratory to transmit the XUV radiation while blocking the longer wavelength radiation that would saturate the detector. The requirements placed on these filters - large size, resistance to degradation by high acoustic and vibration fields, and low pinhole transmittances - were far more severe than those placed on any filters previously flown. Special techniques were developed for vacuum evaporation of the aluminum, removal of the films from the substrates, supporting the films and mounting them to obtain finished filters, and storing them so that no degradation took place. A description of these techniques will be given.

Schumacher, R. J.↗

Kalman filter estimation of attitude and gyro bias with the QUEST observation model

The loss function for the Wahba attitude estimation problem employs unit vector observations with scalar weights. It is usually associated with the QUEST observation model, where the actual sensor noise is assumed the same for all components of the observed vector, regardless of the position in the field of view. The QUEST model has the great advantage of being sensor-independent except for the scalar parameter that characterizes the sensor errors. Although efficient algorithms for solving the Wahba problem exist, extending these algorithms to estimate gyro biases or sensor alignments has had mixed success. However, it is straightforward to estimate bias and alignment parameters with a Kalman filter. This paper investigates the use of an extended Kalman filter for the attitude and gyro bias that incorporates the QUEST observation model, to be referred to as the Unit Vector Filter (UVF). The UVF results are compared with those from a more conventional filter, the Real-Time Sequential Filter (RTSF), for which the residual is the two-dimensional projection of the unit vector onto the plane perpendicular to the sensor boresight. The RTSF is similar in design to that used by Multimission Modular Spacecraft for onboard attitude determination. An apparent obstacle to the use of unit vectors as measurements is their singular noise covariance matrix. Shuster has shown that this problem should not affect filter performance. The UVF and RTSF are tested using actual flight data from the Extreme Ultraviolet Explorer (EUVE). It is found that these filters generate nearly identical attitude and gyro bias estimates, thus validating the use of unit vectors and the QUEST noise model.

Sedlak, J.↗

Photodiode-Based, Passive Ultraviolet Dosimeters

Simple, passive instruments have been developed for measuring the exposure of material specimens to vacuum ultraviolet (VUV) radiation from the Sun. Each instrument contains a silicon photodiode and a coulometer. The photocharge generated in the photodiode is stored in the coulometer. The accumulated electric charge measured by use of the coulometer is assumed to be proportional to the cumulative dose of VUV radiation expressed in such convenient units as equivalent Sun hours (ESH) [defined as the number of hours of exposure to sunlight at normal incidence]. Intended originally for use aboard spacecraft, these instruments could also be adapted to such terrestrial uses as monitoring the curing of ultraviolet-curable epoxies. Each instrument includes a photodiode and a coulometer assembly mounted on an interface plate (see figure). The photodiode assembly includes an aluminum housing that holds the photodiode, a poly(tetrafluoroehylene) cosine receptor, and a narrow-band optical filter. The cosine receptor ensures that the angular response of the instrument approximates the ideal angular response (proportional to the cosine of the angle of incidence). The filter is chosen to pass the ultraviolet wavelength of interest in a specific experiment. The photodiode is electrically connected to the coulometer. The factor of proportionality between the charge stored in the coulometer and ultraviolet dosage (in units of ESH) is established, prior to use, in calibration experiments that involve the use of lamps and current sources traceable to the National Institute of Standards and Technology.

Vaughn, Jason A.↗

Plasma Treatment to Remove Carbon from Indium UV Filters

The sounding rocket experiment FIRE (Far-ultraviolet Imaging Rocket Experiment) will improve the science community fs ability to image a spectral region hitherto unexplored astronomically. The imaging band of FIRE (.900 to 1,100 Angstroms) will help fill the current wavelength imaging observation hole existing from approximately equal to 620 Angstroms to the GALEX band near 1,350 Angstroms. FIRE is a single-optic prime focus telescope with a 1.75-m focal length. The bandpass of 900 to 1100 Angstroms is set by a combination of the mirror coating, the indium filter in front of the detector, and the salt coating on the front of the detector fs microchannel plates. Critical to this is the indium filter that must reduce the flux from Lymanalpha at 1,216 Angstroms by a minimum factor of 10(exp -4). The cost of this Lyman-alpha removal is that the filter is not fully transparent at the desired wavelengths of 900 to 1,100 Angstroms. Recently, in a project to improve the performance of optical and solar blind detectors, JPL developed a plasma process capable of removing carbon contamination from indium metal. In this work, a low-power, low-temperature hydrogen plasma reacts with the carbon contaminants in the indium to form methane, but leaves the indium metal surface undisturbed. This process was recently tested in a proof-of-concept experiment with a filter provided by the University of Colorado. This initial test on a test filter showed improvement in transmission from 7 to 9 percent near 900 with no process optimization applied. Further improvements in this performance were readily achieved to bring the total transmission to 12% with optimization to JPL's existing process.

Greer, Harold F.↗

Hydrogen negative ion production in a 14 GHz electron cyclotron resonance compact ion source with a cone-shaped magnetic filter

The plasma electrode structure of a 14 GHz ECR ion source was modified to enlarge the plasma volume of low electron temperature region. The result shows that the extracted beam current reached about 0.6 mA/cm{sup 2} with about 40 W microwave power. To investigate the correlation between the volume of the low electron temperature region and the H{sup −} current, a vacuum ultraviolet (VUV) spectrometer had been installed to observe light emission in the VUV wavelength range from the plasma. From the results of the negative ion beam current and that from VUV spectrometry, production rate of vibrationally excited hydrogen molecule seems to be enhanced by increasing the volume of low electron temperature region.

43 PARTICLE ACCELERATORS↗

Physical and Visual Evaluation of Filters for Direct Observation of the Sun and the International Standard ISO 12312-2:2015

We investigated the compliance of 43 commercially available solar filters (eclipse glasses) with the ISO 12312-2:2015 standard by measuring their spectral transmittances (280–2000 nm) and calculating their luminous, solar ultraviolet A, ultraviolet B, and infrared (IR) transmittances. We also evaluated the filters for usability by observing the full midday Sun and rating the view on a seven-point balanced scale, from “far too dark, details seen only with great difficulty” to “far too light, uncomfortable to view the Sun.” The mean ratings of two observers, one experienced and one inexperienced in solar observing, differed by 0.28 (95% confidence interval of the mean = 0.26). The inexperienced observer tended to be less accepting of high transmittances. All 43 solar filters complied with the UV and IR requirements. Eighteen filters passed the luminous transmittance requirements, and 24 were borderline too light or too dark. Seven of the 15 solar filters with a luminous transmittance darker than the requirement were rated as acceptable. One filter that passed and another that was borderline too light were rated as too light or far too light. The ISO 12312-2 limits derive from welding filter standards and do not represent an appropriate evidence base for direct solar viewing. This work provides the evidence base for a maximum 0.0012% and a minimum 0.00004% luminous transmittance for solar filters. The results of this study also support the use of welding filters between shades 12 and 16. Lighter welding filters are more acceptable than solar filters of the same luminous transmittance.

79 ASTRONOMY AND ASTROPHYSICS↗