Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Pressure transducer with four-decade dynamic range

Adjustable resistor taps in gain-control feedback loop of the transducer permit wide sensing range, shorting the pins on electrical connector allows selection of appropriate range. Electrical specifications of the transducer and its applications are cited.

Source record↗

Dynamic response of high-frequency pressure transducers to large amplitude sinusoidal pressure oscillations

Dynamic response characteristics of six currently used dynamic pressure transducers were investigated by using a large-amplitude sinusoidal-pressure generator. Frequencies between 1 and 15 kilohertz with corresponding peak-to-peak pressure-oscillation amplitudes ranging between 73 and 8 percent of bias pressure and bias pressures between 15 and 300 psia were utilized. Amplitude-ratio data as functions of frequency and pressure level are given for all transducers. The generator design and performance and associated instrumentation are described.

Robinson, R. E.↗

Miniature biaxial strain transducer

Transducer is completely reusable and permits relocation to alternate points to be accomplished quickly. Size permits measurements to be made simultaneously over small areas and yields outputs directly proportional to strains measured. Transducer verifies elastic modulus, Poisson's ratio, and principal strain axes on materials.

Hoffman, I. S.↗

Transducer technology transfer to bio-engineering applications

The results of a technology transfer of a miniature unidirectional stress transducer, developed for experimental stress analysis in the aerospace field, to applications in bioengineering are reported. By modification of the basic design and innovations in attachment techniques, the transducer was successfully used in vivo on the myocardium of large dogs to record the change in contractile force due to coronary occlusion, reperfusion, and intervention.

Duran, E. N.↗

Demodulator for carrier transducers

A carrier type transducer is supplied with a carrier wave via an audio amplifier, a filter, a frequency divider, and an oscillator. The carrier is modulated in accordance with the parameter being measured by the transducer and is fed to the input of a digital data system which may include a voltmeter. The output of the oscillator and the output of each stage of the divider are fed to an AND or a NAND gate and suitable variable and fixed delay circuits to the command input of the digital data system. With this arrangement, the digital data system is commanded to sample at the proper time so that the average voltage of the modulated carrier is measured. It may be utilized with ancillary circuitry for control of the parameter

Roller, R. F.↗

On-line calibration of high-response pressure transducers during jet-engine testing

Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

Trielectrode capacitive pressure transducer

Capacitive transducer eliminates adverse effects of temperature and humidity; it is especially suited for measuring pressure changes in high-temperature environment. Transducer basically is three-electrode device.

Coon, G. W.↗

On-line calibration of high-response pressure transducers during jet-engine testing

Current jet engine testing is concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique 'no leak' matrix valve design is used in the reference-pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

Development of dynamic calibration methods for POGO pressure transducers

Two dynamic pressure sources are described for the calibration of pogo pressure transducers used to measure oscillatory pressures generated in the propulsion system of the space shuttle. Rotation of a mercury-filled tube in a vertical plane at frequencies below 5 Hz generates sinusoidal pressures up to 48 kPa, peak-to-peak; vibrating the same mercury-filled tube sinusoidally in the vertical plane extends the frequency response from 5 Hz to 100 Hz at pressures up to 140 kPa, peak-to-peak. The sinusoidal pressure fluctuations can be generated by both methods in the presence of high pressures (bias) up to 55 MPa. Calibration procedures are given in detail for the use of both sources. The dynamic performance of selected transducers was evaluated using these procedures; the results of these calibrations are presented. Calibrations made with the two sources near 5 Hz agree to within 3% of each other.

Hilten, J. S.↗

Miniature biaxial strain transducer

A reusable miniature strain transducer for use in the measurement of static or quasi-static, high level, biaxial strain on the surface of test specimens or structures was studied. Two cantilever arms, constructed by machining the material to appropriate flexibility, are self-aligning and constitute the transducing elements of the device. Used in conjunction with strain gages, the device enables testing beyond normal gage limits for high strains and number of load cycles. The device does not require conversion computations since the electrical output of the strain gages is directly proportional to the strain measured.

Hoffman, I. S.↗

Development of a high temperature capacitive pressure transducer

High temperature pressure transducers capable of continuous operation while exposed to 650 C were developed and evaluated over a full-scale differential pressure range of + or - 69 kPa. The design of the pressure transducers was based on the use of a diaphragm to respond to pressure, variable capacitive elements arranged to operate as a differential capacitor to measure diaphragm response and on the use of fused silica for the diaphragm and its supporting assembly. The uncertainty associated with measuring + or - 69 kPa pressures between 20C and 650C was less than + or - 6%.

Egger, R. L.↗

A solid-state phase-insensitive ultrasonic transducer

Photoconductive acoustoelectric transducer (AET) functions as phase-insensitive ultrasonic transducer. Device is easy to use and requires no additional noisy components such as light or thermal source.

Heyman, J. S.↗

Trifunctional transducer for myocardial monitoring

Prototype myocardial transducer simultaneously monitors interal force, displacement, and thickness of heart muscle fiber within localized area of heart muscle. Transducer can be placed in area less than 1.5 by 4 mm.

Culler, V. H.↗

Adjustable holder for transducer mounting

Positioning of acoustic sensor, strain gage, or similar transducer is facilitated by adjustable holder. Developed for installation on Space Shuttle, it includes springs for maintaining uniform load on transducer with adjustable threaded cap for precisely controlling position of sensor with respect to surrounding structure.

Deotsch, R. C.↗

Broadband electrostatic acoustic transducer for ultrasonic measurements in liquids

A broadband capacitive electrostatic acoustic transducer (ESAT) has been developed for use in a liquid environment at megahertz frequencies. The ESAT basically consists of a thin conductive membrane stretched over a metallic housing. The membrane functions as the ground plate of a parallel plate capacitor, the other plate being a dc biased electrode recessed approximately 10 microns from the electrically grounded membrane. An ultrasonic wave incident on the membrane varies the membrane-electrode gap spacing and generates an electrical signal proportional to the wave amplitude. The entire assembly is sealed for immersion in a liquid environment. Calibration of the ESAT with incident ultrasonic waves of constant displacement amplitude from 1 to 15 MHz reveals a decrease in signal response with increasing frequency independent of membrane tension. The use of the ESAT as a broadband ultrasonic transducer in liquids with a predictable frequency response is promising.

Cantrell, J. H., Jr.↗

Broadband electrostatic acoustic transducer for liquids

Capacitive electrostatic transducer (ESAT) measures absolute displacement amplitudes of ultrasonic waves in liquids, and may be used as calibrator for other transducers or as probe for nondestructive study and characterization of materials. ESAT consists of thin conductive membrane stretched over metallic housing. Ultrasonic waves incident on membrane cause it to vibrate and generate signal proportional to wave amplitude. Entire assembly is sealed for immersion in liquid.

Cantrell, J. H.↗

CDS solid state phase insensitive ultrasonic transducer

A phase insensitive ultrasonic transducer which includes a CdS crystal that is annealed for a selected period of time and at a selected temperature to provide substantially maximum acoustic attenuation at the operating frequency of the transducer is described. Two electrodes are attached to the crystal with amplifier means and a signal processing system connected to one of the electrodes to provide an ultrasonic receiver.

Heyman, J. S.↗