Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-angle multi-pulse time-resolved Thomson scattering on laboratory plasma jets

A single channel sub-nanosecond time-resolved Thomson scattering system used for pulsed power-driven high energy density plasma measurements has been upgraded to give electron temperatures at two different times and from two different angles simultaneously. This system was used here to study plasma jets created from a 15 μm thick radial Al foil load on a 1 MA pulsed power machine. Two laser pulses were generated by splitting the initial 2.3 ns duration, 10 J, 526.5 nm laser beam into two pulses, each with 2.5 J, and delaying one relative to the other by between 3 and 14 ns. Time resolution within each pulse was obtained using a streak camera to record the scattered spectra from the two beams from two scattering angles. Analysis of the scattering profile showed that the electron temperature of the Al jet increased from 20 eV up to as much as 45 eV within about 2 ns by inverse bremsstrahlung for both laser pulses. The Thomson scattering results from jets formed with opposite current polarities showed different laser heating of the electrons, as well as possibly different ion temperatures. The two-angle scattering determined that the electron density of the plasma jet was at least 2 × 10 18 cm -3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A platform for x-ray Thomson scattering measurements of radiation hydrodynamics experiments on the NIF

Here, we present an experimental design for a radiation hydrodynamics experiment at the National Ignition Facility that measures the electron temperature of a shocked region using the x-ray Thomson scattering technique. Previous National Ignition Facility experiments indicate a reduction in Rayleigh-Taylor instability growth due to high energy fluxes, compared to the shocked energy flux, from radiation and electron heat conduction. In order to better quantify the effects of these energy fluxes, we modified the previous experiment to allow for non-collective x-ray Thomson scattering to measure the electron temperature. Photometric calculations combined with synthetic scattering spectra demonstrate an estimated noise.

42 ENGINEERING↗

Observation of collisionless-to-collisional transition in colliding plasma jets with optical Thomson scattering

Here we report on the results of an optical (526.5 nm) Thomson scattering investigation of low-Z (C 5 H 8 O 2 ) plasma jets created on the OMEGA laser. We were able to measure the plasma parameters of individual jets and investigate the nature of the interaction when two jets were collided head-on. This work demonstrates that the mass density of an individual jet increased from 10 -7 to 10 -4 g cm -3 , while the velocity fell from 300 to 100 km s over the probed time period (12–18 ns). When two jets were collided, we were able to capture the transition from collisionless interaction (interpenetration) to collisional interaction (stagnation and shock formation). The timing of the collisionless-to-collisional transition was investigated with visible light self-emission images of the experiments, with streaked Thomson scattering of the interaction region, and by calculating the ion penetration depth based on the measured density and velocity of the jets. All three approaches broadly agree: the colliding jets transitioned from collisionless to collisional behavior around 16 ns after drive laser beams were fired.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗

Raster Thomson scattering in large-scale laser plasmas produced at high repetition rate

We present optical Thomson scattering measurements of electron density and temperature in a large-scale (~2 cm) exploding laser plasma produced by irradiating a solid target with a high energy (5-10 J) laser pulse at high repetition rate (1 Hz). The Thomson scattering diagnostic matches this high repetition rate. Unlike previous work performed in single shots at much higher energies, the instrument allows point measurements anywhere inside the plasma by automatically translating the scattering volume using motorized stages as the experiment is repeated at 1 Hz. Measured densities around 4×10 16 cm -3 and temperatures around 7 eV result in a scattering parameter near unity, depending on the distance from the target. The measured spectra show the transition from collective scattering close to the target to non-collective scattering at larger distances. Densities obtained by fitting the weakly collective spectra agree to within 10% with an irradiance calibration performed via Raman scattering in nitrogen.

47 OTHER INSTRUMENTATION↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-dimensional Thomson scattering measurements of misaligned electron density and temperature gradients and associated Biermann battery produced fields

We present optical Thomson scattering measurements of electron density and temperature in high Mach number laser-driven blast waves in homogeneous gases. Taylor–Sedov blast waves are launched in nitrogen (N2) or helium (He) at pressures between 0.4 mTorr and 10 Torr by ablating a solid plastic target with a high energy laser pulse (10 J, 1012 W/cm2). Experiments are performed at high repetition rate (1 Hz), which allows one-dimensional and two-dimensional Thomson scattering measurements over an area of several cm2 by automatically translating the scattering volume between shots. Electron temperature and density in the blast wave fronts were seen to increase with increasing background gas pressure. Measured electron density and temperature gradients were used to calculate ∂B/∂t∝∇Te×∇ne. The experimentally measured ∂B/∂t showed agreement with the magnetic field probe (B-dot) measurements, revealing that magnetic fields are generated in the observed blast waves via the Biermann battery effect. The results are compared to numerical three-dimensional collisional magnetohydrodynamic simulations performed with FLASH, and are discussed in the context of spontaneous magnetic field generation via the Biermann battery effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A deep learning approach to fast analysis of collective Thomson scattering spectra

Fast analysis of collective Thomson scattering ion acoustic wave features using a deep convolutional neural network model is presented. The network was trained from spectra to predict the plasma parameters, including ion velocities, population fractions, and ion and electron temperatures. A fully kinetic particle-in-cell simulation was used to model a laboratory astrophysics experiment and simulate a diagnostic image of the ion acoustic wave feature. Network predictions were compared with Bayesian inference of the plasma model parameters for both the simulated and experimentally measured images. Both approaches were fairly accurate predicting the simulated image and the network predictions matched a good portion of the Bayesian results for the experimentally measured image. The Bayesian approach is more robust to noise and motivates future work to train deep learning models with realistic noise. The advantage of the deep learning model is making thousands of predictions in a few hundred milliseconds, compared to a few seconds to minutes per prediction for the optimization and Bayesian approaches presented here. The results demonstrate promising capabilities of deep learning models to analyze Thomson data orders of magnitude faster than conventional methods when using the neural network for standalone analysis. If more rigorous analysis is needed, neural network predictions can be used to quickly initialize other optimization methods and increase chances of success. This is especially useful when the dataset becomes very large or highly dimensional and manually refining initial conditions for the entire dataset are no longer tractable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of Thomson-scattering spectra with continuous angular resolution (invited)

Here, a novel Thomson-scattering diagnostic with continuous angular resolution over a span of 120° was developed for the characterization of plasmas produced at the Omega Laser Facility. Spectrally resolving light scattered from electron plasma wave features as a function of emission angle provides a means to efficiently probe a large range of plasma frequencies and k vectors. Together, these spectra contain critical constraints on the plasma-physics models used to interpret the data and enable experimental measurements of the electron-velocity distribution function over several orders of magnitude without assumptions about its mathematical form. Major components of the instrument include (1) a reflective collection objective that gathers light over a range of 120° × 12°; (2) a spatial-filter image relay for measurement localization; (3) cylindrical optics for producing a line image of the collection aperture; (4) a transmission grating spectrometer; and (5) a time-gated, image-intensified camera. Thomson-scattered light collected from an ~(50 – μM) 3 volume of plasma is recorded with 0.8-nm spectral and 1° angular resolution. Initial experiments examined the properties of the electron-velocity distribution in gas-jet-produced plasmas in the presence of heating via inverse bremsstrahlung absorption.

47 OTHER INSTRUMENTATION↗

Statistical inference of collision frequencies from x-ray Thomson scattering spectra

Thomson scattering spectra measure the response of plasma particles to incident radiation. In warm dense matter, which is opaque to visible light, x-ray Thomson scattering (XRTS) enables a detailed probe of the electron distribution and has been used as a diagnostic for electron temperature, density, and plasma ionization. In this work, we examine the sensitivities of inelastic XRTS signatures to modeling details, including the dynamic collision frequency and the electronic density of states. Applying verified Monte Carlo inversion methods to dynamic structure factors obtained from time-dependent density functional theory, we assess the utility of XRTS signals as a way to inform the dynamic collision frequency, especially its direct-current limit, which is directly related to the electrical conductivity.

Collision frequency↗

Primordial helium recombination. III. Thomson scattering, isotope shifts, and cumulative results

Upcoming precision measurements of the temperature anisotropy of the cosmic microwave background at high multipoles will need to be complemented by a more complete understanding of recombination, which determines the damping of anisotropies on these scales. This is the third in a series of papers describing an accurate theory of He i and He ii recombination. Here we describe the effect of Thomson scattering, the {sup 3}He isotope shift, the contribution of rare decays, collisional processes, and peculiar motion. These effects are found to be negligible: Thomson and {sup 3}He scattering modify the free electron fraction x{sub e} at the level of severalx10{sup -4}. The uncertainty in the 2{sup 3}P{sup o}-1{sup 1}S rate is significant, and for conservative estimates, gives uncertainties in x{sub e} of order 10{sup -3}. We describe several convergence tests for the atomic level code and its inputs, derive an overall C{sub l} error budget, and relate shifts in x{sub e}(z) to the changes in C{sub l}, which are at the level of 0.5% at l=3000. Finally, we summarize the main corrections developed thus far. The remaining uncertainty from known effects is {approx}0.3% in x{sub e}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Material Assessment for ITER's Collective Thomson Scattering first mirror

The International Thermonuclear Energy Reactor (ITER) Collective Thomson Scattering (CTS) system is a diagnostic instrument that measures plasma density and velocity through Thomson scattering of microwave radiation. Some of the key components of the CTS are quasi-optical mirrors that are used to produce astigmatic beam patterns, which have impact on the strength and spatial resolution of the diagnostic signal. The mirrors are exposed to neutron radiation, which may alter the quality of the signal received. In this work, three different materials (molybdenum (Mo), stainless steel 316 (SS-316) and tungsten (W)) are considered for the first mirror of the CTS. The objective is to access which of the material studied are best suited for this mirror, considering different neutron radiation loads simulated scenarios defined by ITER, based on the resultant stresses and temperature distributions. For it, the neutron irradiation, and subsequent heat-load on the mirrors are simulated using the Monte Carlo N-Particle (MCNP) code. Based on the MCNP heat-load results, transient thermal-structural Finite Element Analysis (FEA) of the mirror over a 400 s discharge, with and without cooling on the rear side, are conducted using in commercial FEA software ANSYS. Results show that of the tested materials Mo and W are the most suitable material for this application. Even though, this study does not yet consider the variation of the material properties with temperature, it presents a quick initial satisfactory assessment that may be considered in subsequent and more complex analysis. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Thomson scattering of a relativistically strong tightly focused ultrashort laser pulse

The problem of nonlinear Thomson scattering of a relativistically strong linearly polarized ultrashort laser pulse tightly focused into a spot with a diameter of D{sub F} ≳ λ (where λ is the laser wavelength) is solved. The energy, spectral, and angular distributions of radiation generated due to Thomson scattering from test electrons located in the focal region are found. The characteristics of scattered radiation are studied as functions of the tightness of laser focusing and the initial position of test particles relative to the center of the focal region for a given laser pulse energy. It is demonstrated that the ultratight focusing is not optimal for obtaining the brightest and hardest source of secondary electromagnetic radiation. The hardest and shortest radiation pulse is generated when the beam waist diameter is ≃10λ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A scalable real-time framework for Thomson scattering analysis: Application to NSTX-U

A detailed description of a prototype setup for real-time (rt) Thomson scattering (TS) analysis is presented and implemented in the multi-point Thomson scattering (MPTS) diagnostic system at the National Spherical Torus Experiment Upgrade(NSTX-U). The data acquisition hardware was upgraded with rt capable electronics (rt-analog digital converters (ADCs) and a rt server) that allow for fast digitization of the laser pulse signal of eight radial MPTS channels. In addition, a new TS spectrum analysis software for a rapid calculation of electron temperature (Te) and electron density (ne) was developed. Testing of the rt hardware and data analysis soft-ware was successfully completed and benchmarked against the standard, post-shot evaluation. Timing tests were performed showing that the end-to-end processing time was reproducibly below 17 ms for the duration of at least 5 s, meeting a 60 Hz deadline by the laser pulse repetition rate over the length of a NSTX-U discharge. The presented rt framework is designed to be scalable in system size, i.e. incorporation of additional radial channels by solely adding additional rt capable hardware. Furthermore, it is scalable in its operation duration and was continuously run for up to 30 min, making it an attractive solution for machines with long discharge duration such as advanced, non-inductive tokamaks or stellarators.

Plasma, Tokamak, Diagnostic, Thomson scattering, r↗

Thomson Scattering Density Calibration by Rayleigh and Rotational Raman Scattering on NSTX

The multi-point Thomson scattering (MPTS) diagnostic measures the profiles of the electron temperature Te(R) and density ne(R) on the horizontal midplane of NSTX. Normal operation makes use of Rayleigh scattering in nitrogen or argon to derive the density profile. While the Rayleigh scattering ne(R) calibration has been validated by comparison with other density measurements and through its correlation with plasma phenomena, it does require dedicated detectors at the laser wavelength in this filter polychromator based diagnostic. The presence of dust and/or stray laser light precludes routine use of these dedicated spectral channels for Thomson scattering measurement. Hence it is of interest to investigate the use of Raman scattering in nitrogen for the purpose of density calibration, since it could free up detection equipment, which could then be used for the instrumentation of additional radial channels. In this paper the viewing optics "geometrical factor" profiles obtained from Rayleigh and Raman scattering are compared. While both techniques agree nominally, residual effects on the order of 10% remain and will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Thomson scattering measurements of radiatively heated Xe

Uniform density and temperature Xe plasmas have been produced over >4 mm scale-lengths using x-rays generated in a cylindrical Pb cavity. The cavity is 750 {micro}m in depth and diameter, and is heated by a 300 J, 2 ns square, 1054 nm laser pulse focused to a spot size of 200 {micro}m at the cavity entrance. The plasma is characterized by simultaneous imaging Thomson scattering measurements from both the electron and ion scattering features. The electron feature measurement determines the spatial electron density and temperature profile, and using these parameters as constraints in the ion feature analysis allows an accurate determination of the charge state of the Xe ions. The Thomson scattering probe beam is 40 J, 200 ps, and 527 nm, and is focused to a 100 {micro}m spot size at the entrance of the Pb cavity. Each system has a spatial resolution of 25 {micro}m, a temporal resolution of 200 ps (as determined by the probe duration), and a spectral resolution of 2 nm for the electron feature system and 0.025 nm for the ion feature system. The experiment is performed in a Xe filled target chamber at a neutral pressure of 3-10 Torr, and the x-rays produced in the Pb ionize and heat the Xe to a charge state of 20 {+-} 4 at up to 200 eV electron temperatures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Successful X-ray Thomson Scattering Using Picosecond K-(alpha) X-ray Sources for the Characterization of Dense Heated Matter

We discuss the first successful K-{alpha} x-ray Thomson scattering experiment from solid density plasmas for use as a diagnostic in determining the temperature, density, and ionization state of warm dense matter with picosecond resolution. The development of this source as a diagnostic and stringent requirements for successful K-{alpha} x-ray Thomson scattering are addressed. Data for the experimental techniques described in this paper [1] suggest the capability of single shot characterization of warm dense matter and the ability to use this scattering source at future Free Electron Lasers (FEL) where comparable scattering signal levels are predicted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Thomson scattering system on VEST

A Thomson scattering (TS) system has been developed on Versatile Experiment Spherical Torus (VEST) to measure the electron temperature and the density. In VEST, it is quite challenging to measure TS signals because the energy of the utilized pulsed laser and the target electron density are low, 0.85 J and ~5×1018 m-3, respectively. Furthermore, the difficulties caused by filter specifications have to be resolved because of the use of commercial interference filters with broad bandwidth and poor blocking at the laser wavelength. Therefore, we especially optimize the placement order of the filter sets based on the evaluation of the relative errors to overcome the poor spectral resolution. In addition, the amount of the stray light that penetrating filters is reduced by vacuum components such as baffles, louvres, and a viewing dump. With the careful installation and the optimization of the system, we can develop an efficient Thomson scattering system. Recently, TS signals have been successfully measured from the ohmic plasmas, and the electron temperature and the density are determined by analyzing the signals with the Bayesian method.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗