Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Portable Oxygen Subsystem - Description and preliminary thermal performance prediction

This paper describes the use, operation, and preliminary thermal modeling of a Portable Oxygen Subsystem (POS). The POS is a partial rebreather which is being developed for Shuttle Orbiter support. Normally used as a pre-breather for denitrogenization prior to EVA, this semi-closed, breath powered breathing system can also be used for emergencies in the event of a contaminated or oxygen-deficient cabin atmosphere, to support an emergency transfer between vehicles, or as a clean oxygen supply in the event of a contaminated ambient atmosphere in the vicinity of the Orbiter after landing.

Sribnik, F.↗

In-Flight Thermal Performance of the Lidar In-Space Technology Experiment

The Lidar In-Space Technology Experiment (LITE) was developed at NASA s Langley Research Center to explore the applications of lidar operated from an orbital platform. As a technology demonstration experiment, LITE was developed to gain experience designing and building future operational orbiting lidar systems. Since LITE was the first lidar system to be flown in space, an important objective was to validate instrument design principles in such areas as thermal control, laser performance, instrument alignment and control, and autonomous operations. Thermal and structural analysis models of the instrument were developed during the design process to predict the behavior of the instrument during its mission. In order to validate those mathematical models, extensive engineering data was recorded during all phases of LITE's mission. This inflight engineering data was compared with preflight predictions and, when required, adjustments to the thermal and structural models were made to more accurately match the instrument s actual behavior. The results of this process for the thermal analysis and design of LITE are presented in this paper.

Roettker, William↗

Structural and preliminary thermal performance testing of a pressure activated contact heat exchanger

A contact heat exchanger concept is being developed for use onboard Space Station as an interface device between external thermal bus and pressurized modules. The concept relies on mechanical contact activated by the fluid pressure inside thin-walled tubes. Structural testings were carried out to confirm the technology feasibility of using such thin-walled tubes. The test results also verified the linear elastic stress analysis which was used to predict the tube mechanical behaviors. A preliminary thermal testing was also performed with liquid Freon-11 flowing inside tubes and heat being supplied by electrical heating from the bottom of the contact heat exchanger baseplate. The test results showed excellent agreement of test data with analytical prediction for all thermal resistances except for the two-phase flow characteristics. Testing with two-phase flow inside tubes will, however, be performed on the NASA-JSC test bed.

Lee, C. Y.↗

Laser performance, thermal focusing and depolarization effects in Nd:Cr:GSGG and Nd:YAG

The laser performance of Nd:Cr:GSGG and Nd:YAG was investigated and compared for laser efficiency, thermal focusing, and depolarization effects. Laser efficiency was studied for Nd:Cr:GSGG and Nd:YAG under similar conditions. Laser efficiency was measured as a function of electrical energy and output mirror reflectivity. Maximum laser efficiency was calculated by determining the losses in the laser cavity. Thermal focusing and birefringence loss of Nd:Cr:GSGG and Nd:YAG have been examined by varying the average pump power. The average pump power changed by adjusting both the energy per pulse and the pulse-repetition frequency. Substantial thermal focusing differences for Nd:Cr:GSGG are explained.

Williams-Byrd, Julie A.↗

Impact of U-10Mo HALEU fuel element tolerances on the Massachusetts Institute of Technology reactor safety and operational performance – Thermal hydraulics

The U.S. is coordinating efforts for the conversion of six U.S. High Performance Research Reactors (USHPRR) including one critical facility from highly enriched uranium (HEU) to low-enriched uranium (LEU). In order to continue the mission of these reactors, including the Massachusetts of Institute of Technology Reactor (MITR), and achieve similar performance, high-assay low-enriched uranium (HALEU) with a high-density metallic alloy of uranium with 10 wt% molybdenum (U-10Mo) is being evaluated. The impact of the fabrication specification and tolerances was assessed following the preliminary design of the MITR LEU fuel elements using the U-10Mo monolithic alloy. This research focuses on the analysis of fabrication specification impact on thermal hydraulics (TH) characteristic of the MITR LEU core as a function of the variation of the relevant fuel specification parameters (e.g., coolant channel gap thickness, fuel plate thickness, etc.). The analyses are performed based on an all-fresh LEU fuel conversion plan identified in a preliminary safety analysis report submitted to the Nuclear Regulatory Commission. The reactor power margin to the onset of nucleate boiling (ONB) is assessed under the limiting safety system settings (LSSS), where a scram occurs, to ensure there is sufficient margin to the reactor safety limit, which is defined by the onset of flow instability that occurs after the ONB. The best estimate plus uncertainty approach is employed to analyze this TH characteristic, which yields realistic results while maintaining adequate conservatism, utilizing a statistical uncertainty propagation method with the STAT7 code. The TH characteristic is analyzed as a function of the variability of the specification parameters resulting from the fabrication process. The main findings of this study show that the MITR core can meet the TH safety and operational requirements at the all-LEU initial core startup (cycle 1), selected transition cycles (most reactive cycle and most limiting cycle: cycle 3 and 5, respectively) and equilibrium (cycle 14) cores under all limiting fabrication parameter combinations considered. In addition, the analyses show that the dependency of the core power margin to ONB on those specification parameters that have the most direct impact on TH performance is non-linear but monotonically decreasing within the specification tolerances. The third order polynomial fit curves are reported in detail for selected limiting cases and can serve as a powerful tool for future MITR fuel management in cases such as when HALEU supply is established that may allow additional cycle length or other operational benefits.

Conversion↗

Thermal Performance of a Customized Multilayer Insulation (MLI). Design and Fabrication of Test Facility Hardware

The design, fabrication, and assembly of hardware for testing the performance of a customized multilayer insulation are discussed. System components described include the thermal payload simulator, the modified cryoshroud, and a tank back pressure control device designed to maintain a constant liquid boiling point during the thermal evaluation of the multilayer insulation. The thermal payload simulator will provide a constant temperature surface in the range of 20.5 to 417K (37 to 750R) for the insulated tank to view. The cryoshroud was modified to establish a low temperature black body cavity while limiting liquid hydrogen usage to a minimum feasible rate.

Leonhard, K. E.↗

Thermal Performance of the Texas Instruments 1-W Linear Drive Cryocooler

The efficiency, of the electronics plays a large part in determining the overall spacecraft power requirements to operate the cooler as well as determining the thermal dissipation characteristics of the various electrical components. The results of all the performance measurements are presented in the paper.

linear drive cryocooler temperature thermal dissip↗

Programmable Thermostats for MPLM Shell Heater Control ULF1: Thermal Performances - 1

The Multi-Purpose Logistics Module (MPLM) is the primary carrier for "pressurized" logistics to and from the International Space Station (ISS). The MPLM is transported in the payload bay of the Space Shuttle and is docked to the ISS for unloading, and reloading, of contents within the ISS shirt sleeve environment. Foil heaters, controlled originally with bi-metallic thermostats, are distributed across the outside of the MPLM structure and are utilized to provide energy to the structure to avoid exposure to cold temperatures and prevent condensation. The existing bi-metallic, fixed temperature set point thermostats have been replaced with Programmable Thermostats Modules (PTMs) in the Passive Thermal Control Subsystem (PTCS) 28Vdc shell heater circuits. The goal of using the PTM thermostat is to improve operational efficiency of the MPLM on-orbit shell heaters by providing better shell temperature control via feedback control capability. Each heater circuit contains a programmable thermostat connected to an external temperature sensor, a Resistive Temperature Device (RTD), which is used to provide continuous temperature monitoring capability. Each thermostat has programmable temperature set points and control spans. The data acquisition system uses a standard RS-485 serial interface communications cable to provide digital control capability. The PTM system was designed by MSFC, relying upon ALTEC support for their integration within the MPLM system design, while KSC performed the installation and ground checkout testing of the thermostat and RS-485 communication cable on the MPLM FM1 flight module. The PTMs were used for the first time during the STS-121/ULF1.1 mission. This paper will describe the design, development and verification of the PTM system, as well as the PTM flight performance and comparisons with SINDA thermal model predictions.

Glasgow, Shaun↗

Thermal performance of honeywell double covered liquid solar collector

The test procedures and results obtained during an evaluation test program to determine the outdoor performance characteristics of the Honeywell liquid solar collector are presented. The program was based on the thermal evaluation of a Honeywell double covered liquid solar collection. Initial plans included the simultaneous testing of a single covered Honeywell collector. During the initial testing, the single covered collector failed due to leakage; thus, testing continued on the double covered collector only. To better define the operating characteristics of the collector, several additional data points were obtained beyond those requested.

Losey, R.↗

Analytic model for assessing thermal performance of SCUBA divers

To assist design of adequate protective clothing, mathematical model of man's thermoregulatory system has been developed so that body thermal responses under immersed conditions can be predicted accurately. Experimental data encompassed wide range of water temperatures, protective clothing, breathing-gas mixtures, and durations of immersion.

Montgomery, L. D.↗

Analysis of thermal performance of penetrated multi-layer insulation

Results of research performed for the purpose of studying the sensitivity of multi-layer insulation blanket performance caused by penetrations through the blanket are presented. The work described in this paper presents the experimental data obtained from thermal vacuum tests of various penetration geometries similar to those present on the Hubble Space Telescope. The data obtained from these tests is presented in terms of electrical power required sensitivity factors referenced to a multi-layer blanket without a penetration. The results of these experiments indicate that a significant increase in electrical power is required to overcome the radiation heat losses in the vicinity of the penetrations.

Foster, Winfred A., Jr.↗

Intraspecific Diversity in Thermal Performance Determines Phytoplankton Ecological Niche

ABSTRACT Temperature has a primary influence on phytoplankton physiology and ecology. We grew 12 strains of Gephyrocapsa huxleyi isolated from different‐temperature regions for ~45 generations (2 months) and characterised acclimated thermal response curves across a temperature range. Even with similar temperature optima and overlapping cell size, strain growth rates varied between 0.45 and 1 day −1 . Thermal niche widths varied from 16.7°C to 24.8°C, suggesting that strains use distinct thermal response mechanisms. We investigated the implications of this thermal intraspecific diversity using an ocean ecosystem simulation resolving phytoplankton thermal phenotypes. Model analogues of thermal ‘generalists’ and ‘specialists’ resulted in a distinctive global biogeography of thermal niche widths with a nonlinear latitudinal pattern. We leveraged model output to predict ranges of the 12 lab‐reared strains and demonstrated how this approach could broadly refine geographic range predictions. Our combination of observations and modelled biogeography highlights the capacity of diverse groups to survive temperature shifts.

Krinos, Arianna I. [Department of Biology Woods Ho↗