Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

HST/WFC3 Observations of Giant Hot Exoplanets

Low resolution thermal emission spectra of several dozen extrasolar planets have been measured using Spitzer, and HST observations of a few key exoplanets have reported molecular abundances via transmission spectroscopy. However, current models for the atmospheric structure of these worlds exhibit degeneracies wherein different combinations of temperature and molecular abundance profiles can fit the same Spitzer data. The advent of the IR capability on HST/WFC3 allows us to address this problem. We are currently obtaining transmission spectroscopy of the 1.4-micron water band in a sample of 13 planets, using the G141 grism on WFC3. This is the largest pure-exoplanet program ever executed on HST (115 orbits). Among the abundant molecules, only water absorbs significantly at 1.4-microns, and our measurement of water abundance will enable us to break the degeneracies in the Spitzer results with minimal model assumptions. We are also using the G141 grism to observe secondary eclipses for 7 very hot giant exoplanets at 1.S-microns, including several bright systems in the Kepler and CoRoT fields. The strong temperature sensitivity of the thermal continuum at 1.S-microns provides high leverage on atmospheric temperature for these worlds, again helping to break degeneracies in interpreting the Spitzer data. We here describe preliminary results for several exoplanets observed in this program.

Deming, D.↗

Method and apparatus for precision control of radiometer

A radiometer controller of a radiation detector is provided with a calibration method and apparatus comprised of mounting all temperature sensitive elements of the controller in thermostatically controlled ovens during calibration and measurements, using a selected temperature that is above any which might be reached in the field. The instrument is calibrated in situ by adjusting heater power (EI) to the receptor cavity in the radiometer detector to a predetermined full scale level and is displayed by a meter.

Estey, R. S.↗

Adapting Apollo-Era Instrumentation for Cold Sample Processing While Maintaining Curatorial Standard Practices

The goal of the Apollo Next Generation Sample Analysis (ANGSA) Program is to study “specially curated samples,” that is, unstudied Apollo samples that have been preserved under unique conditions. A subset of the funded ANGSA work includes the study of Apollo samples stored under cold conditions since their return from the Moon. Ongoing ANGSA processing and future returned samples require cold curation strategies to preserve the integrity of organic and other temperature-sensitive constituents within those samples. Standard Apollo curation processing hardware and procedures are designed for room temperature operations, not cold conditions. This abstract details the major modifications of a heritage lunar cabinet in preparation for the first cold curation processing at Johnson Space Center. Future publications will provide greater detail on the low temperature materials and operation procedures. This work not only supports Apollo but also future cold sample return missions.

Amick, Cecilia L.↗

Atmospheric Temperature from Raman Scattering

Raman scattering signatures are functions of the scattering-gas temperature, and are therefore of potential use for practical atmospheric temperature probes. The method described uses either ratios of pure rotational Raman scattering intensities for air utilizing various spectral bandpasses, or, alternatively, ratios of air-rotational to nitrogen-vibrational scattering intensities. Three aspects of work relating to the development of such probes are discussed in this presentation: (1) fundamental absolute Raman data, (2) construction of air spectra from these data, and (3) temperature-sensitivity of the signature. The fundamental data described are the absolute rotational and vibrational scattering cross sections. Recent measurements in this laboratory of rotational cross sections for N2, O2, and CO2 are emphasized, as are their use in predicting absolute magnitudes of Raman scattering signals. Next is described the computation of air rotational Raman spectra as a function of temperature calculated through use of the experimentally-measured cross sections. The spectra are based additively upon nitrogen and oxygen contributions, since pure rotational Raman scattering from water vapor is very weak. Finally, the sensitivity of the scattering intensity ratios to temperature is explored as a function of choice of spectral bandpass for the monitored rotational Raman scattering. Various compromises will be discussed which must be made in choosing bandpasses appropriate for specific purposes and experimental conditions.

Lapp, M.↗

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.↗

High-Temperature Sprayable Phosphor Coating Developed for Measuring Surface Temperatures

The use of phosphor thermography for noncontact temperature measurements in harsh environments has been proven over the last decade, but it has suffered from difficult application procedures such as vapor deposition or sputtering techniques. We have developed a high-temperature-sensitive paint that is easily applied with commercially available paint-spraying equipment and have successfully demonstrated it to temperatures up to 1500 C. Selected phosphors have also shown measurable signals to 1700 C, thus allowing a combination of phosphors to be used in high-temperature binders to make surface temperature measurements from ambient to over 1500 C. Phosphor thermography is an optical technique that measures the time response of fluorescence light, which is a function of the phosphor temperature. The phosphors are excited with short wavelength light (ultraviolet or blue), and they emit light at a longer wavelength. This technique has a benefit over other temperature measurements, such as thermocouples and infrared thermography, in difficult environments such as high blackbody backgrounds, vibration, flames, high electromagnetic noise, or where special windows may be needed. In addition, the sprayable phosphor paints easily cover large or complicated structures, providing full-surface information with a single measurement. Oak Ridge National Laboratories developed and tested the high-temperature binders and phosphors under the direction of the NASA Glenn Research Center. Refractory materials doped with rare earth metals were selected for their performance at high temperature. Survivability, adhesion, and material compatibility tests were conducted at high temperatures in a small furnace while the fluorescent response from the phosphors was being measured. A painted sample in a furnace with a clearly visible fluorescing dot excited by a pulsed laser is shown. Measuring the decay time of this fluorescence yields the surface temperature. One new paint was recently tested in a rocket test stand at Glenn. The floor of a square duct nozzle was painted, and full-field lifetime decay measurements were acquired for multiple firings of the rocket. Good agreement with predicted results was obtained, matching temperature gradients along the length of the nozzle and clearly showing shock structures. These good results were very satisfactory given that the measurements were made looking through the combustion plume. Infrared pyrometry was incapable of making the surface measurements because of the interference from the rocket exhaust, which contaminated the infrared signature.

Bencic, Timothy J.↗

MODIS airborne simulator visible and near-infrared calibration, 1991 FIRE-Cirrus field experiment. Calibration version: FIRE King 1.1

Calibration of the visible and near-infrared channels of the MODIS Airborne Simulator (MAS) is derived from observations of a calibrated light source. For the 1991 FIRE-Cirrus field experiment, the calibrated light source was the NASA Goddard 48-inch integrating hemisphere. Laboratory tests during the FIRE Cirrus field experiment were conducted to calibrate the hemisphere and from the hemisphere to the MAS. The purpose of this report is to summarize the FIRE-Cirrus hemisphere calibration, and then describe how the MAS was calibrated from observations of the hemisphere data. All MAS calibration measurements are presented, and determination of the MAS calibration coefficients (raw counts to radiance conversion) is discussed. Thermal sensitivity of the MAS visible and near-infrared calibration is also discussed. Typically, the MAS in-flight is 30 to 60 degrees C colder than the room temperature laboratory calibration. Results from in-flight temperature measurements and tests of the MAS in a cold chamber are given, and from these, equations are derived to adjust the MAS in-flight data to what the value would be at laboratory conditions. For FIRE-Cirrus data, only channels 3 through 6 were found to be temperature sensitive. The final section of this report describes comparisons to an independent MAS (room temperature) calibration by Ames personnel using their 30-inch integrating sphere.

Arnold, G. Thomas↗

Temperature and Humidity Dependence of a Polymer-Based Gas Sensor

This paper quantifies the temperature and humidity dependence of a polymer-based gas sensor. The measurement and analysis of three polymers indicates that resistance changes in the polymer films, due to temperature and humidity, can be positive or negative. The temperature sensitivity ranged from +1600 to -320 ppm/nd the relative sensitivity ranged from +1100 to -260 ppm/%.

temperature humidity gas sensor polymers↗

Suppression of Buoyancy in Gaseous Media at High Temperatures

Consider a rectangular box filled with a fluid having a heated bottom and a cold top surface, and insulated side-walls (Benard problem). As the temperature difference between the horizontal top and bottom surfaces increases, a critical condition, defined quantitatively by the Rayleigh number, is reached beyond which density stratification can no longer be sustained by conduction and the fluid disrupts from its stable, quiescent state into an unstable, convective mode in which lighter and heavier gas mix. This paper suggests that such a statement is not necessarily true for gaseous media under normalized temperature differences that are much larger than justifiable for the Boussinesq approximation! In fact, there may be situations where a system cannot ever be made unstable with respect to the onset on buoyant convection no matter how large the temperature (density) difference becomes at a given pressure even under normal gravity! This unexpected behavior is primarily attributed to highly temperature-sensitive kinematic viscosity which counteracts the tendency toward instability and dampens convection by making the gas more viscous at higher temperatures. This compensation of the buoyant force by the viscous force exhibits itself by the formation of a peak hot-surface temperature beyond which a system will tend to be more stable as the hot-surface temperature increases.

Gokoglu, Suleyman A.↗

Laboratory studies at high resolution of the infrared absorption spectra of a number of gases found in planetary atmospheres

The infrared absorption spectra of a number of gases found in planetary atmospheres were studied at high resolution. Absorption line measurements which can be of value for the interpretation of planetary spectra in terms of molecular abundances and conditions in the planetary atmospheres were provided. The high resolution spectra have yielded measurements of individual vibration rotation line parameters including positions, strengths, pressure broadened widths and, where assignments were unknown, the temperature sensitivity of the strengths. Such information allows the determinations of the absorption of a given molecular gas under planetary conditions of temperature and pressure and at the same time it provides the data necessary if the spectra are to be understood in terms of basic molecular theory. Thus this work has included spectral analysis in the form of line assignments as well as fitting of the data to Hamiltonian models. Such fitting is very useful in that it helps to confirm and extend the assignments.

Hunt, R. H.↗

Progress in kinetic inductance thermometers for X-ray calorimeters

Conventional X-ray microcalorimeters have so far used ionimplanted resistors for thermometers. Recently, however, several new methods for sensing small temperature changes have been suggested that are nondissipative. Such devices may have intrinsically better energy resolution by eliminating the Johnson noise present in resistive devices. The use of kinetic inductance thermometers for X-ray microcalorimeters is being investigated. This technique exploits the strong temperature dependence of magnetic penetration depth of thin superconducting films. The prototype system, designed for operation at 1.5 K, uses films of aluminum and tin. Once the expected temperature sensitivity and alpha particle detection have been demonstrated, aluminum will be replaced with titanium or another material with a suitable critical temperature and the device will be operated at 0.3 K. At this temperature, the energy resolution from thermal noise should be sufficiently good to allow X-ray detection.

Rawley, G. L.↗

Space Shuttle Thermal Protection System Repair Flight Experiment Induced Contamination Impacts

NASA s activities to prepare for Flight LF1 (STS-114) included development of a method to repair the Thermal Protection System (TPS) of the Orbiter s leading edge should it be damaged during ascent by impacts from foam, ice, etc . Reinforced Carbon-Carbon (RCC) is used for the leading edge TPS. The repair material that was developed is named Non- Oxide Adhesive eXperimental (NOAX). NOAX is an uncured adhesive material that acts as an ablative repair material. NOAX completes curing during the Orbiter s descent. The Thermal Protection System (TPS) Detailed Test Objective 848 (DTO 848) performed on Flight LF1 (STS-114) characterized the working life, porosity void size in a micro-gravity environment, and the on-orbit performance of the repairs to pre-damaged samples. DTO 848 is also scheduled for Flight ULF1.1 (STS-121) for further characterization of NOAX on-orbit performance. Due to the high material outgassing rates of the NOAX material and concerns with contamination impacts to optically sensitive surfaces, ASTM E 1559 outgassing tests were performed to determine NOAX condensable outgassing rates as a function of time and temperature. Sensitive surfaces of concern include the Extravehicular Mobility Unit (EMU) visor, cameras, and other sensors in proximity to the experiment during the initial time after application. This paper discusses NOAX outgassing characteristics, how the amount of deposition on optically sensitive surfaces while the NOAX is being manipulated on the pre-damaged RCC samples was determined by analysis, and how flight rules were developed to protect those optically sensitive surfaces from excessive contamination where necessary.

Smith, Kendall A.↗

Creating a Multifunctional Composite Stator Slot Material System to Enable High Power Density Electric Machines for Electrified Aircraft Applications

Increasing the power density and efficiency of electric machines (motors and generators) is integral to bringing Electrified Aircraft (EA) to commercial realization. However, power density and efficiency are not qualities that can be developed independently. At the heart of any electric machine are the conductors (usually copper) that carry current and generate magnetic fields. Increased power density means increased current density and increased joule heating in a smaller volume. To increase efficiency at the wire level means minimizing electrical resistance and hence power lost to joule heating. There are fundamental challenges with concomitantly increasing both power density and efficiency since the copper resistivity is very temperature sensitive at common electric machine operating conditions. Simple calculations of the linear increase in resistivity of copper as a function of temperature, reveals that a one degree Celsius increase in temperature results in a 0.39% decrease in efficiency. Conversely, a 20 degree Celsius decrease in copper temperature produces a 7.8% increase in efficiency. Therefore, improved thermal management concepts for electric machine building blocks such as stator winding are a priority for improving efficiency and power density. This paper proposing changing the view of component materials in the stator slots from individual components with singular functionality to a composite system where the components take on a multifunctional roles. In the composite framework, achievable material development goals are defined that together have maximum system impact on the thermal environment inside of high power density electric machines for aerospace applications.

thermal management↗

Photographing flow fields and heat-transfer patterns in color simultaneously.

A color-schlieren technique is described that combines the flow-field shock shapes and the phase-change coating to give a very descriptive account of aerodynamic heating. This technique employs, in addition to the conventional schlieren system, a temperature-sensitive material as a thin surface coating that undergoes a visible phase change from opaque solid to clear liquid at a known temperature. The resulting pictures can lead to a better understanding of shock/boundary layer interactions, as shown with the aid of a specific example.

Creel, T. R., Jr.↗

Cryogenic Curation of Lunar Samples Returned to Earth

Future lunar missions may collect samples that have been preserved at sub-freezing or even cryogenic temperatures. For such samples, the study of volatiles and temperature-sensitive minerals will have high priority. Valuable geochemical and mineralogical information will be lost if such samples are allowed to reach ambient temperatures on Earth. The ability to store, document, subdivide, and transport extraterrestrial geologic samples while maintaining sub-freezing or cryogenic temperatures, possibly as low as 40 K, is required for the complete scientific study of samples from cold environments. A lunar cryogenic sample return mission might require a combination of passive cooling during collection and cruise and active cooling during and after re-entry for maintaining desired temperatures. Once on Earth, cryocontainment must be maintained through delivery to a cryogenic chamber in the curatorial facility. This cryogenic curation chamber would include cameras and robotic manipulators for preliminary examination, subdivision of samples, and specialized sample allocation containers for shipment to laboratories world-wide. This presentation describes the planning and feasibility of cryogenic curation with current technologies developed for the superconductor industry. In addition, significant advanced research and development would be required to tailor some of these technologies to the task of sample return and long term curation of lunar samples at low temperatures in order to preserve their scientific integrity.

Calaway, Michael J.↗

Cryogenic Curation: Isolated Technology and Mission Operational Requirements for Sample Return

Future lunar, Mars, asteroid, and comet sample return missions may collect samples that have been preserved at sub-freezing or even cryogenic temperatures. For such samples, the study of volatiles and temperature-sensitive minerals will have high priority. Valuable geochemical and mineralogical information will be lost if such samples are allowed to reach ambient temperatures on Earth. The ability to store, document, subdivide, and transport extraterrestrial geologic samples while maintaining sub-freezing or cryogenic temperatures, possibly as low as 40 K, is required for the complete scientific study of samples from cold environments.

Calaway, Michael J.↗

M dwarf spectra from 0.6 to 1.5 micron - A spectral sequence, model atmosphere fitting, and the temperature scale

Red/infrared (0.6-1.5 micron) spectra are presented for a sequence of well-studied M dwarfs ranging from M2 through M9. A variety of temperature-sensitive features useful for spectral classification are identified. Using these features, the spectral data are compared to recent theoretical models, from which a temperature scale is assigned. The red portion of the model spectra provide reasonably good fits for dwarfs earlier than M6. For layer types, the infrared region provides a more reliable fit to the observations. In each case, the wavelength region used includes the broad peak of the energy distribution. For a given spectral type, the derived temperature sequence assigns higher temperatures than have earlier studies - the difference becoming more pronounced at lower luminosities. The positions of M dwarfs on the H-R diagram are, as a result, in closer agreement with theoretical tracks of the lower main sequence.

Kirkpatrick, J. D.↗

Submillimeter Planetary Atmospheric Chemistry Exploration Sounder

Planetary Atmospheric Chemistry Exploration Sounder (SPACES), a high-sensitivity laboratory breadboard for a spectrometer targeted at orbital planetary atmospheric analysis. The frequency range is 520 to 590 GHz, with a target noise temperature sensitivity of 2,500 K for detecting water, sulfur compounds, carbon compounds, and other atmospheric constituents. SPACES is a prototype for a powerful tool for the exploration of the chemistry and dynamics of any planetary atmosphere. It is fundamentally a single-pixel receiver for spectral signals emitted by the relevant constituents, intended to be fed by a fixed or movable telescope/antenna. Its front-end sensor translates the received signal down to the 100-MHz range where it can be digitized and the data transferred to a spectrum analyzer for processing, spectrum generation, and accumulation. The individual microwave and submillimeter wave components (mixers, LO high-powered amplifiers, and multipliers) of SPACES were developed in cooperation with other programs, although with this type of instrument in mind. Compared to previous planetary and Earth science instruments, its broad bandwidth (approx. =.13%) and rapid tunability (approx. =.10 ms) are new developments only made possible recently by the advancement in submillimeter circuit design and processing at JPL.

Schlecht, Erich T.↗