Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Targets (spallation source targets, radioisotope production, neutrino and muon sources)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3,186 records · Page 8

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Chlorine isotope separations using thermal diffusion

In a chloride molten salt fast reactor (Cl-MSFR), the fuel salt might be comprised of a specific eutectic composition of alkali and alkaline chlorides that solubilize major and minor actinide chlorides as the fertile component(s). Each of the chloride species contain the natural abundance ( 35 Cl ~76% and 37 Cl ~24%) of the two stable isotopes of chlorine 35 Cl and 37 Cl. There has been an ongoing controversy for the operation of the Cl-MSFRs concerning the potential of the 35 Cl(n,γ) 36 Cl, 35 Cl(n,p) 35 S, 35 Cl(n,α) 32 S reactions to produce 36 Cl, 32 S, and 32 P at relevant energies [Bulmer 1956]. The undesirable attributes of irradiated 35 Cl are enumerated further below.

07 ISOTOPE AND RADIATION SOURCES

Effect of magnetic fields on Urca rates in neutron star mergers

Isospin-equilibrating weak processes, called “Urca” processes, are of fundamental importance in astrophysical environments like (proto-)neutron stars, neutron star mergers, and supernovae. In these environments, matter can reach high temperatures of tens of MeVs and be subject to large magnetic fields. We thus investigate Urca rates at different temperatures and field strengths by performing the full temperature and magnetic-fielddependent rate integrals for different equations of state. We find that the magnetic fields play an important role at temperatures of a few MeV, especially close to or below the direct Urca threshold, which is softened by the magnetic field. At higher temperatures, the effect of the magnetic fields can be overshadowed by the thermal effects. Finally, we observe that the magnetic field influences the neutron decay rates more strongly than the electron-capture rates, leading to a shift in the flavor equilibrium.

electroweak interactions in nuclear physics

Enhancing NO Reduction by CO Over NiO/CeO 2 Catalyst by Optimizing the Metal Oxide–Support Interaction

Noble metal catalysts are widely used in three-way catalysts (TWCs) due to their high efficiency, but their scarcity and high cost drive the need for effective, low-cost alternatives. Here, in this work, a series of NiO/CeO 2 catalysts were engineered by modulating the OH content and crystallite size of the CeO 2 support. This approach yielded Ni species ranging from isolated single atoms to small clusters and larger aggregates, with varied NiO/CeO 2 interaction strengths. Evaluation of their performance in NO reduction by CO, CO oxidation, and the water–gas shift reaction revealed that the NiO/CeO 2 -300 catalyst, featuring small CeO 2 crystallites and highly dispersed NiO clusters, delivered superior activity for NO reduction and CO oxidation. It was demonstrated that small NiO clusters, due to their efficient CO adsorption and activation, were more active than Ni single atoms. Furthermore, the presence of water was found to influence the catalyst stability, with NiO clusters less stable than single atoms likely due to the hydroxylation effect leading to the formation of Ni(OH) 2 . Oxygen storage capacity measurements revealed that performance was governed by a combination of CeO 2 crystallite size and the abundance of NiO/CeO 2 interfaces. These findings demonstrated that the catalytic performance of Ni/CeO 2 systems could be maximized by optimizing the Ni nanostructure and its interaction with CeO 2 support, positioning them as a promising, multifunctional nonprecious alternative for three-way catalysis application.

36 MATERIALS SCIENCE

EvoDiffMol: evolutionary diffusion framework for 3D molecular design with optimized properties

Designing molecules with specific target properties remains a fundamental challenge in computational chemistry. While existing approaches show promise, most rely on simplified representations like SMILES strings or 2D graphs that lack essential three-dimensional geometric information. We present EvoDiffMol, a computational framework that integrates evolutionary algorithms with three-dimensional diffusion models for property-driven molecular generation. The method operates through adaptive evolutionary optimization, where population-based selection guides the generation process toward desired property landscapes. EvoDiffMol supports both unconstrained molecular design and scaffold-constrained generation that preserves fixed substructures while optimizing complementary regions. Comprehensive evaluation demonstrates exceptional performance, achieving the highest drug-likeness score (0.94) among all compared state-of-the-art methods while maintaining excellent validity, uniqueness, and novelty. Beyond single property optimization, the framework demonstrates flexible multi-property optimization capabilities, simultaneously controlling multiple molecular descriptors including synthetic accessibility, lipophilicity, topological polar surface area, and clinically relevant ADMET properties such as cardiotoxicity (hERG) and intestinal permeability (Caco-2). This adaptability spans from simple descriptors to practical pharmaceutical endpoints without requiring complete model retraining. The framework achieves precise control over target property values, generating molecules with properties closely matching specified targets for both single and multiple descriptors. Scaffold-constrained experiments preserve fixed molecular cores while maintaining effective property optimization. The three-dimensional representation offers advantages in maintaining structural validity during iterative optimization, with potential for geometry-aware applications in materials science and drug discovery.

3D molecular generation

Uranus Orbiter and Probe: Mission Challenges and Concept Updates Since the Origins, Worlds, and Life Decadal Survey

Origins, Worlds, and Life: Planetary Science and Astrobiology in the Next Decade identified a Uranus Orbiter and Probe as the highest-priority strategic mission for the decade 2023–2032, as it enables broad cross-disciplinary science in the largely unexplored Uranian system. The mission architecture evaluated by the Decadal Survey was a singular proof of concept demonstrating that a moderately instrumented mission could deliver Decadal-priority science with a reduced cost and risk posture by leveraging existing technologies to the maximum extent possible. With revised assumptions since the Decadal, we have explored a large trade space including launch vehicles, propulsion options, cruise trajectories, available power sources, viable concept of operations, and science data return for later launch dates without a Jupiter gravity assist. The most repeatable trajectory solutions employ either a commercially derived solar electric propulsion (SEP) transfer stage or the availability of a more capable launch vehicle under development, such as the SpaceX Starship. Orbit insertion has been moved farther from Uranus to acknowledge the remaining uncertainty in Uranian ring structure. A streamlined, SEP-adaptable, orbiter design was developed using two Next Gen Radioisotope Thermoelectric Generators, and the probe design was matured, reducing the entry gravitational acceleration, and assuming the largest Decadal-recommended payload to provide margin for future instrument selections. With this updated design, we also constructed a detailed concept of operations for three representative science cases, returning 13–15 Gbit of science data and spacecraft telemetry per ∼34 day orbit.

Amy A Simon

Quantifying System Strength From Grid-Forming Resources Using Frequency Scan Approach: Preprint

Current industry practices for quantifying the system strength contribution from grid-forming (GFM) resources to ensure stability of power systems dominated by inverter-based resources (IBRs) are primarily based on iterative electromagnetic transient (EMT) time-domain simulation studies. While feasible, these approaches are resource-intensive, lack scalability and intuition, and might not evaluate the system strength contribution over the entire frequency range of interest. This paper introduces a novel, frequency-domain approach to quantify system strength support provided by a GFM resource using frequency scans. The proposed method uses transfer functions from the grid voltage magnitude (V) and phase (?), respectively, to the reactive (Q) and active power (P) output of a GFM resource for quantifying its contribution to system strength. These transfer functions provide a direct measure of the ability of a GFM resource to behave as a stiff voltage source behind a reactance over a specified frequency range, enabling robust quantification of its system strength contribution. The key innovation of this work is the development of a frequency domain system strength metric called the dynamic short-circuit ratio (dSCR) that is suitable for IBR-dominated power systems and is directly related with the familiar short circuit ratio (SCR) metric. The new metric, dSCR, enables the assessment of system strength contributions from both synchronous machines and converter-based GFM resources using a unified benchmark, which is not possible with the traditional SCR metric. The paper also demonstrates how impedance scans could identify if an unstable condition observed during weak grid conditions is a result of the lack active or reactive power support or both. By leveraging the proposed frequency-domain dSCR metric for quantifying system strength contribution from GFM IBRs, the paper demonstrates targeted mitigation strategies for weak grid instabilities without resorting to repeated, time-consuming time-domain simulations. The result is a scalable and efficient approach to remediate stability challenges in power systems with high shares of IBRs and accelerating the integration of GFM technologies for system strength support in power systems.

24 POWER TRANSMISSION AND DISTRIBUTION

Laboratory Investigations: Low Earth Orbit Environment Chemistry With Spacecraft Surfaces

Long-term space operations that require exposure of material to the low earth orbit (LEO) environment must take into account the effects of this highly oxidative atmosphere on material properties and the possible contamination of the spacecraft surroundings. Ground-based laboratory experiments at Los Alamos using a newly developed hyperthermal atomic oxygen (AO) source have shown that not only are hydrocarbon based materials effected but that inorganic materials such as MoS2 are also oxidized and that thin protective coatings such as Al2O3 can be breached, producing oxidation of the underlying substrate material. Gas-phase reaction products, such as SO2 from oxidation of MoS2 and CO and CO2 from hydrocarbon materials, have been detected and have consequences in terms of spacecraft contamination. Energy loss through gas-surface collisions causing spacecraft drag has been measured for a few select surfaces and has been found to be highly dependent on the surface reactivity.

Jon B Cross

BISON analyses of TRISO fuel performance, its dependence on time-at-temperature, and possible implications for fuel design and qualification

The Advanced Gas Reactor Fuel Development and Qualification (AGR) program has established a substantial technical foundation to support private entry into the U.S. high-temperature gas-cooled reactor market. However, emerging tristructural isotropic (TRISO)-fueled reactor applications include small modular reactors and microreactors with longer fuel residence times, which may expose fuels to higher time-at-temperature (TAT) values than were explored by the AGR program. Increased TAT could affect diffusive and thermomechanical behaviors such as Pd penetration, fission gas release, creep, and fission product transport. In this work, we applied multiscale best-estimate BISON fuel performance modeling to assess these effects within a representative design space based on the AGR-5/6/7 experiment and analyzed trends in predicted particle and compact fuel performance metrics with possible implications for near-term fuel design and qualification. BISON unambiguously predicted that TRISO fuel performance is sensitive to TAT. Increasing TAT was not predicted to increase the magnitude of failure-inducing tangential stresses in particle coating layers. Predictions obtained using a mechanistic model for Pd penetration indicated that penetration depth does not depend strongly on TAT. While these observations suggest that AGR testing provides a conservative upper bound for the steady-state operation of TRISO particles at lower powers and higher residence times, BISON also predicted that the release of poorly retained Ag would increase with TAT. Because these analyses applied models to extrapolate beyond the available experimental data, the authors recommend performing targeted experiments to confirm these predictions. Nevertheless, these predictions may provide reactor developers with enough confidence to make near-term design decisions associated with the potential fuel performance trade-offs of increasing TAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

RG-CAT: Detection pipeline and catalogue of radio galaxies in the EMU pilot survey

Abstract We present source detection and catalogue construction pipelines to build the first catalogue of radio galaxies from the 270$\rm deg^2$pilot survey of the Evolutionary Map of the Universe (EMU-PS) conducted with the Australian Square Kilometre Array Pathfinder (ASKAP) telescope. The detection pipeline uses Gal-DINO computer vision networks (Gupta et al. 2024, PASA, 41, e001) to predict the categories of radio morphology and bounding boxes for radio sources, as well as their potential infrared host positions. The Gal-DINO network is trained and evaluated on approximately 5 000 visually inspected radio galaxies and their infrared hosts, encompassing both compact and extended radio morphologies. We find that the Intersection over Union (IoU) for the predicted and ground-truth bounding boxes is larger than 0.5 for 99% of the radio sources, and 98% of predicted host positions are within$3^{\prime \prime}$of the ground-truth infrared host in the evaluation set. The catalogue construction pipeline uses the predictions of the trained network on the radio and infrared image cutouts based on the catalogue of radio components identified using theSelavysource finder algorithm. Confidence scores of the predictions are then used to prioritiseSelavycomponents with higher scores and incorporate them first into the catalogue. This results in identifications for a total of 211 625 radio sources, with 201 211 classified as compact and unresolved. The remaining 10 414 are categorised as extended radio morphologies, including 582 FR-I, 5 602 FR-II, 1 494 FR-x (uncertain whether FR-I or FR-II), 2 375 R (single-peak resolved) radio galaxies, and 361 with peculiar and other rare morphologies. Each source in the catalogue includes a confidence score. We cross-match the radio sources in the catalogue with the infrared and optical catalogues, finding infrared cross-matches for 73% and photometric redshifts for 36% of the radio galaxies. The EMU-PS catalogue and the detection pipelines presented here will be used towards constructing catalogues for the main EMU survey covering the full southern sky.

Astronomy & Astrophysics

NASA's RPS Program Status Update and Future Outlook

Radioisotope Power Systems (RPS) have been safely providing the United States with the power to explore space for almost 65 years. NASA established the RPS Program in 2010 to support specialized science missions and potential future opportunities more effectively and efficiently. The RPS Program ensures the availability of RPS for the exploration of the solar system in environments where conventional solar or chemical power generation is impractical or impossible. NASA missions have utilized space nuclear power to explore planets, moons, and interstellar space, enabling missions to some of the deepest, darkest, and dustiest regions in the solar system and beyond. This scientific exploration has deepened our understanding of the solar system and our role within. The RPS Program, in partnership with the Department of Energy (DOE) Office of Nuclear Energy continues to operate as an interagency partnership to provide robust radioisotope power system solutions to spacecraft that conduct missions to extreme environments for science and exploration. This Program invests in systems and technologies to ensure that NASA maintains this capability well into the future and it manages processes that ensure the safe use and launch of these systems. This paper provides a synopsis of current activities of the RPS Program, and it introduces a focus on the commercialization of RPS to enable a variety of future mission applications.

radioisotope power systems

Emergent surface resonance from charge density wave symmetry breaking in TiSe 2

Surface confined electronic states provide a fertile ground for discovering emergent phenomena that have no counterpart in the bulk, offering new routes to manipulate correlations, symmetry breaking, and dimensionality at the atomic scale. Here, in this study, we show that charge density wave (CDW) symmetry breaking can yield surface states in 1⁢T−TiSe 2 . Micro–angle-resolved photoemission spectroscopy (µ-ARPES) resolves a sharp, two-dimensional surface resonant state (SRS) that emerges within the CDW reconstructed low energy spectrum. The SRS exhibits notable temperature dependence and its spectral weight collapses around ∼ 160 K, while CDW transition temperature 𝑇 CDW is commonly reported as ≈ 202 K. Slab DFT + 𝑈 calculations reproduce a surface localized resonance when CDW folding brings valence and conduction states into near degeneracy, suggesting a correlation tuned, surface selective origin. These results point to a form of correlation-tuned surface resonance in a layered CDW compound and suggest a framework for engineering low-dimensional quantum states in van der Waals materials via symmetry breaking and electronic structure tuning.

36 MATERIALS SCIENCE

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Improving Ionic Conformality Across Polymer Electrolyte|Electrode Interfaces

Maintaining uniform ionic transport at electrode|electrolyte interfaces, i.e., ionic conformality, remains challenging in polymer electrolyte (PE)-based solid-state batteries. Morphological conformality does not necessarily imply ionic conformality. In PEs, which typically consist of a mechanically supporting component and distinct ionically conductive components, the rearrangement or depletion of mobile ion-conductive domains at interfaces can disrupt ionic transport pathways. Such localized ionic depletion contributes to interfacial instability and capacity degradation in high-voltage lithium-metal batteries. Herein, an electrolyte design approach aimed at minimizing interfacial heterogeneities is demonstrated through compositional adjustments, characterized by spatially resolved structural and chemical X-ray techniques and NMR diffusometry to elucidate ion transport dynamics. This approach improves ionic conformality at electrode interfaces, enhancing cycling stability in Li||LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NMC811) coin and pouch cells cycled at high voltages. These results contribute to understanding interfacial behaviors in multiphase PEs and inform strategies for improving stability across solid-state battery interfaces.

36 MATERIALS SCIENCE

Collapse of magnetized white dwarfs as site of heavy-element formation and kilonova signal

We present the first end-to-end calculation connecting the accretion-induced collapse (AIC) of a magnetized, rapidly rotating white dwarf to observable kilonova signatures, combining two-dimensional (2D) general-relativistic neutrino-magnetohydrodynamic simulations, followed by radiation hydrodynamics with in-situ nuclear network and 2D Monte Carlo radiative transfer with spatially resolved heating rates. Unlike all previous unmagnetized AIC models – which predicted proton-rich, $^{56}$Ni-dominated ejecta – strong magnetic fields eject ${\approx }\, 0.2\, \mathrm{ M}_\odot$ of neutron-rich material ($\langle Y_e \rangle \sim 0.24$) on dynamical time-scales, before neutrino irradiation can raise the electron fraction, enabling strong r-process nucleosynthesis up to and beyond the third peak. The resulting kilonova is lanthanide-rich ($X_{\rm lan} \approx 8~{{\ \rm per\ cent}}$) and dominated by near-infrared emission. We compute synthetic light curves in the Large Synoptic Survey Telescope and J ames Webb Space Telescope bands and find striking agreement, without parameter tuning, between the observations of AT 2023vfi/GRB 230307A and our broadband light curves for polar viewing angles. These results establish magnetized AIC as a viable channel for heavy r-process element production and a compelling progenitor candidate for long-duration gamma-ray bursts with kilonova signatures.

MHD

SENTRA: A Modular Computational Graph Framework for Critical Mineral and Materials Supply Chains: Part I: Network Construction Latent-Quantity Estimation, and Temporal Graph Forecasting

Global supply chains for critical minerals and materials are complex, evolving networks of countries, products, production stages, and trade relationships. Existing analytical approaches are limited by fragmented data and static network representations that do not capture the dynamic production dependencies linking raw materials, intermediate products, and final goods across multiple countries. Trade and production statistics provide only a partial view of domestic production, inventories, and material flows, making it difficult to identify indirect sourcing pathways, hidden dependencies, and embedded foreign exposures. This paper introduces the Supply Chain Exposure Network Tracking and Risk Assessment (SENTRA) framework, a modular graph-based computational framework for constructing, analyzing, and forecasting dynamic supply chain networks. As the first paper in a three-part methodological series, it establishes the computational foundation of SENTRA by constructing a temporal attributed multi-relational graph whose nodes represent product–country pairs and whose edges encode observed trade and within-country value-chain relationships. Statistical estimation and constrained optimization recover latent production, final demand, and product input dependency coefficients while enforcing economic accounting constraints. Graph-derived exposure measures quantify direct, transshipment, value-chain, and multi-hop supply chain dependencies independently of the forecasting model. A temporal graph forecasting architecture based on a relational graph neural network then forecasts the evolution of the graph under mass-balance constraints with distribution-free conformal uncertainty quantification. Validation on the global aluminum supply chain shows that the learned graph representations recover economically meaningful supply chain structure, accurately forecast out-of-sample trade relationships, and produce well-calibrated prediction intervals. Subsequent papers apply this computational foundation to exposure assessment, disruption analysis, and scenario-based policy analysis, and extend the framework to multimaterial supply chain modeling and decision support.

36 MATERIALS SCIENCE

Estimating the Size of Huffman Code Preambles

Data compression via block-adaptive Huffman coding is considered. The compressor consecutively processes blocks of N data symbols, estimates source statistics by computing the relative frequencies of each source symbol in the block, and then synthesizes a Huffman code based on these estimates. In order to let the decompressor know which Huffman code is being used, the compressor must begin the transmission of each compressed block with a short preamble or header file. This file is an encoding of the list n = (n 1 , n 2 ....,n m ), where n i is the length of the Hufffman codeword associated with the ith source symbol. A simple method of doing this encoding is to individually encode each n i into a fixed-length binary word of length log 2 l, where l is an a priori upper bound on the codeword length. This method produces a maximum preamble length of mlog 2 l bits. The object is to show that, in most cases, no substantially shorter header of any kind is possible.

R J McEliece

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI