Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TaPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Temporal Analysis Of Products Statistical Analysis Processing

Temporal analysis of products statistical analysis package (tapsap) is a package for reading, cleaning, analyzing and making inference of temporal analysis of products (TAP) information. This package is designed with the intent for collaboration within the TAP community for advancing TAP analysis.

Kunz, MatthewR↗

Tapless Voltage Regulating Transformer. Final Report

Voltage regulation is a common practice in power grid operation. The conventional voltage regulation methods have been facing ever increasing challenges as the penetration of renewable generations deepens in the grid. The intermittent nature of the renewable sources may result in sudden rise or drop of power generation, possibly breaking the generation-load balance. A lack of adequate voltage control not only affects the power quality but is detrimental to the system operation with the potential for large economic losses. Most conventional voltage regulation devices rely on mechanical tap changers to impose the regulation in a step-wise manner. Although sufficient for normal operations, the mechanical tap changers can be easily worn out in the challenging situations created by renewables. In this project, a novel technology called tapless voltage regulating transformer (TAREX) was proposed and investigated. It has the potential to excel at addressing the new voltage regulation challenges and replace the conventional regulating transformers. TAREX is based on the concept of the saturable-core reactor (SCR). The voltage of a TAREX can be smoothly and continuously regulated in a reasonable range by using a low rating power electronics based controller. It uses control of the transformer core magnetization to regulate the voltage on the windings, and thus eliminates the mechanical tap changer. This project is to prove the principle of TAREX, understand the voltage regulation mechanism, and preliminarily understand its impacts on the power systems through modeling, prototyping, and testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SolSmart Technical Assistance Provider (Final Technical Report)

The SolSmart program was established in late 2015 to “establish a prominent national recognition and technical assistance program for local governments that will signal to installers and the public that a community is receptive to solar businesses and has established a supportive solar market environment. This, in turn, will reduce market barriers and lower soft costs, thus contributing to SunShot goals. The program will also assist communities who are just beginning to improve their solar markets.” By March 31, 2022 (the grant end date), the SolSmart Team designated 460 communities, more than 50% more than the initial program objective of 300 communities. The designated communities represent 42 states, the District of Columbia, the U.S. Virgin Islands, and Puerto Rico. The SolSmart team developed and revised criteria representing best practices for local governments; recruited, trained, evaluated, and mentored communities to incorporate these best practices; and disseminated resources about solar and solar-related technologies as well as the newest best practices on a regular basis. 98% of local government officials who participated in the program said that SolSmart increased their knowledge of solar energy. The SolSmart program had both real and perceived tangible impacts on barriers to solar adoption in designated communities. Significantly, the time to permit a solar installation decreased by 7.5 days on average. This reduced the soft costs for both the solar installer (and therefore the customer) and the local government. The result is that solar installations in SolSmart communities increased by 17% per month compared with similar non-SolSmart communities. Larger and wealthier communities were more likely to pursue SolSmart designation and earn more points within SolSmart. As a result, IREC/TSF developed strategies to reach underserved communities and created new resources to help them more easily achieve designation, as described below. In the last year of the Award, 44% of designated communities were underserved, compared with 31% in the earlier years of the program. DOE issued two awards for SolSmart: the SolSmart Technical Assistance Provider (TAP), led by The Solar Foundation (TSF) which has since merged with the Interstate Renewable Energy Council (IREC), and the Designation Program Administrator (DPA), led by the International City/County Management Association (ICMA). IREC was lead for the TAP project and, until the time of TSF/IREC merger, was a subrecipient on the DPA project. These two projects were interdependent; one could not exist without the other. While this report will focus on the work performed by the TAP, it will be impossible to speak of this without talking about the successes, impacts, and benefits of the overall SolSmart program.

14 SOLAR ENERGY↗

Development of Engineered Metal-Organic Framework (MOF) materials for perfluorooctane sulfonate (PFOS) Remediation

In this project, an engineered form of a Metal-Organic Framework (MOF) based material is developed for the removal of perfluorooctane sulfonate (PFOS) for real-world applications. The powdered MOF material has been demonstrated at the Pacific Northwest National Laboratory (PNNL) to selectively capture PFOS from distilled (DI) water with a large performance advantage over granulated activated carbon (GAC). In this project, the powdered material was transformed into an engineered form (using a polymer) to demonstrate PFOS adsorption capacity in tap water. PNNL developed and processed the MOF material in the engineering form (granules). After thorough characterization and stability testing, these engineered MOF granules were provided to an industrial collaborator, AVANTech, LLC, for testing and demonstration of continuous, long-term PFOS removal from tap water. The preliminary results showed PFOS sorption capacities at parts per billion (ppb) concentrations in tap water under a flow system. Also provided insight into sorbent-based material utilization in a continuous flow system. Further studies are required to optimize and understand sorption in such industrial-scale applications.

36 MATERIALS SCIENCE↗

U.S. DOE Southeast Combined Heat and Power Technical Assistance Partnership

During the five-year period from September 2018 to December 2023, the Industrial Efficiency and Decarbonization office (IEDO) of the U.S. Department of Energy (DOE) funded the Southeast Combined Heat and Power Technical Assistance Partnership (Southeast CHP TAP), managed the NC Clean Energy Technology Center located at NC State University (NCSU). The Southeast CHP TAP was one of ten regional CHP TAPs established to promote and assist in transforming the market for combined heat and power (CHP) and related technologies, including district energy (DE) and waste heat to power (WHP) throughout the United States. CHP, also known as cogeneration, is an efficient and clean approach to generating on-site electric power and useful thermal energy from a single fuel source.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Developing a Robust Market for CHP: A Plan for Fostering Economic Development, Business Competitiveness and Resiliency in the Mid-Atlantic Region

The Department of Energy’s Mid Atlantic Combined Heat and Power Technical Assistance Partnership (MA CHP TAP) was established to develop public-private partnerships to advance the technology, policies, and programmatic support for combined heat and power (CHP), including its application in microgrids, heat to power and district energy. The MA CHP TAP’s work includes education and outreach as well as technical assistance to a variety of stakeholders including end-users (commercial, industrial, institutional and more), state decision makers, electric and gas utilities, trade associations and non-profit organizations. This assistance includes evaluating the economic, energy, reliability and environmental value of proposed systems. The MA CHP TAP represents the multi-state Mid- Atlantic region and is the CHP expert in the region who provides fact-based, un-biased information on CHP, including technologies, project development, project financing, local electric and natural gas utility interfaces, and related state best practice policies.

20 FOSSIL-FUELED POWER PLANTS↗

Technical Background and Validation Report on the Residential Water Inhalation Risk Calculator Presented in the Risk Assessment Information System

Indoor air quality (IAQ) is critical for human health. Poor IAQ is linked to respiratory issues, cardiovascular diseases, and cancer. Indoor pollutants are emitted by typical household items such as cleaning products, personal care items, building materials, and tap water - an understudied volatile organic compound (VOC) source. This document presents the Residential Water Inhalation Risk Calculator (RWIRC), which estimates daily VOC exposure concentrations from various household water uses, such as showering and dishwashing, to assess exposure risks for the most vulnerable occupant. Integrated into the Risk Assessment Information System (RAIS) and sponsored by the US Department of Energy (DOE), the calculator divides a house into three compartments: shower, bathroom, and other spaces, accounting for daily water usage patterns and calculating VOC concentrations. Exposure data generated using the calculator can assist health assessors in estimating excess lifetime cancer risk (ELCR) and hazard index (HI) from VOC inhalation. Unlike traditional exposure models that utilize Andelman’s constant, the RWIRC continuously assesses variability in VOC concentrations and environmental conditions using differential equations to track VOC concentrations and air exchange between compartments. The calculator also provides unique volatilization fractions for each chemical and appliance, enhancing accuracy of the exposure concentration estimation. The RWIRC is accessible online and allows users to customize parameters (i.e., number of bathrooms, water temperature, and exhaust fan conditions) and input VOC characteristics (i.e., tap water and ambient air concentrations). This document provides a step-by-step guide on implementing the calculator. It also provides comparisons with the ATSDR-SHOWER calculator, using eight VOCs with varying physicochemical properties to reveal differences in algorithms and output concentrations. Simulations also assess how bathroom door positions and exhaust fan usage affect VOC exposure. The calculator results can enhance EPA risk screening levels for inhalation exposure to VOCs from tap water, offering a sophisticated tool for assessing inhalation risks and improving public health protection.

54 ENVIRONMENTAL SCIENCES↗

Characterization of ceramic fuel powder packing fractions to support INFLUX

Triply periodic minimal surface (TPMS)-based structures show marked potential in novel nuclear reactor fuel designs, as their high surface area-to-volume ratio increases the efficiency of heat transfer out of the fuel, enabling safer, more innovative reactor designs. This milestone report addresses the role of dUO 2 powder processing route on the fill behavior of TPMS-based cladding shells to understand and advance the feasibility of manufacturing TPMS-based nuclear fuel forms. dUO 2 powder was processed through either a dry granulation route, varying consolidation pressure, or through milling, varying milling time, milling method and milled size distribution. The lowest tapped bulk densities (TBD), but best powder flowabilities, were obtained when testing unprocessed dUO 2 powder which was prone to self-agglomeration and formed low-density spheroids. The highest TBD and lowest flowabilities were obtained when using powder produced by hammer-milling dUO 2 powder to pass through a 200-mesh sieve, which led to particles with angular morphologies. Powder produced by dry granulation exhibited TBD that varied according to the consolidation pressure used to form the initial pellets and exhibited improved flowabilities when compared to hammer-milled material. Because of the large span of granule sizes formed as well as the irregular shape associated with the granules, a packing fraction of 0.69 was achieved, exceeding the analytical solution for random close packing of mono-sized spheres. TPMS polymer shells were loaded with unprocessed, granulated, and hammer-milled dUO 2 powders, and their qualitative packing behaviors were analyzed using x-ray computed tomography (xCT). TBDs calculated after loading TPMS polymer shells were 10-20% lower when compared to tapped bulk density measurements taken in a glass graduated cylinder, indicating a non-trivial impact on the tapped bulk density of either the TPMS channel size, TPMS channel surface material, powder cohesiveness, or a combination of the two parameters. A metallic zircaloy-4 TPMS shell will be loaded with hammer-milled dUO 2 powder upon receipt of the shell from Oak Ridge National Laboratory (ORNL) and shipped to Idaho National Labs (INL) for subsequent hot isostatic pressing (HIP) densification experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗

A fast-initializing digital equalizer with on-line tracking for data communications

A theory is developed for a digital equalizer for use in reducing intersymbol interference (ISI) on high speed data communications channels. The equalizer is initialized with a single isolated transmitter pulse, provided the signal-to-noise ratio (SNR) is not unusually low, then switches to a decision directed, on-line mode of operation that allows tracking of channel variations. Conditions for optimal tap-gain settings are obtained first for a transversal equalizer structure by using a mean squared error (MSE) criterion, a first order gradient algorithm to determine the adjustable equalizer tap-gains, and a sequence of isolated initializing pulses. Since the rate of tap-gain convergence depends on the eigenvalues of a channel output correlation matrix, convergence can be improved by making a linear transformation on to obtain a new correlation matrix.

Houts, R. C.↗

A maximum likelihood convolutional decoder model vs experimental data comparison

This article describes the comparison of a maximum likelihood convolutional decoder (MCD) prediction model and the actual performance of the MCD at the Madrid Deep Space Station. The MCD prediction model is used to develop a subroutine that has been utilized by the Telemetry Analysis Program (TAP) to compute the MCD bit error rate for a given signal-to-noise ratio. The results indicate that that the TAP can predict quite well compared to the experimental measurements. An optimal modulation index also can be found through TAP.

Chen, R. Y.↗

System for automatically switching transformer coupled lines

A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.

Dwinell, W. S.↗

Active notch filter network with variable notch depth, width and frequency

An active notch filter having independently adjustable notch frequency, width, and depth is provided by three equal capacitors connected in series with an operational amplifier (connected in a voltage follower configuration), a potentiometer across the series connected capacitors for notch depth adjustment, and a potentiometer (for notch frequency connected across the center capacitor); with its tap connected to receive a voltage feedback signal from a variable voltage divider comprised of another potentiometer for notch width. Adjusting the voltage dividing potentiometer will independently set the notch width, and adjusting the tap on the potentiometer across the center capacitor will independently adjust the notch frequency of the filter. A second operational amplifier connected in a voltage follower configuration may be used to connect the voltage divider output to the adjustable tap of the potentiometer across the center capacitor.

Black, J. M.↗

A program to evaluate a control system based on feedback of aerodynamic pressure differentials. Part 2: Data report for phase 1 wind tunnel test

Wind tunnel test data are presented. The purpose of the test was to determine the sensor location for sensitivity to flap deflection and to determine the range required of the sensor. The calculations followed to correct the raw pressure measurements, the corrected measurements, which represent the static pressures along the airfoil surface, and the static pressures tabulated and in coefficient form are described. However, the chordwise locations of the upper and lower surface taps do not coincide. An interpolation routine is performed to find the lower surface pressure coefficients at the upper surface tap locations. The difference, C sub P(lower) - C sub P(upper), is calculated and listed and the data are reorganized with respect to each tap location. A numerical regression performed to quantify the slopes of the graphs allows more accurate comparison of sensitivity and linearity.

Hrabak, R. R.↗

Laser velocimetry measurement in a transonic tunnel

Some preliminary velocity measurements were carried out inside the transonic tunnel using the laser velocimeter (LV) system in association with the smoke generator. Pressure measurements were also performed using a pressure tap located on the side wall of the test section slightly upstream of the windows. Though the pressure measurements and the LV measurements were not taken at exactly the same location, extrapolation of the pressure data into the location of the LV measurements indicated a very close agreement between the velocity values obtained using the two different methods. Thus it is believed that the smoke particle is following the air flow with little or no velocity slip. Velocity measurements with airfoil at various angles of attack are now being carried out in conjuction with schlieren flow visualization. In the near future pressure distribution around and on the airfoil will be obtained by putting pressure taps on the side windows and using a pressure tap model (currently under construction) of the airfoil.

Ng, T. T.↗

Erosion of aluminum 6061-T6 under cavitation attack in mineral oil and water

Studies of the erosion of aluminum 6061-T6 under cavitation attack in distilled water, ordinary tap water and a viscous mineral oil are presented. The mean depth of penetration for the mineral oil was about 40 percent of that for water at the end of a 40 min test. The mean depth of penetration and its rate did not differ significantly for distilled and tap water. The mean depth of penetration rate for both distilled and tap water increased to a maximum and then decreased with test duration, while that for mineral oil had a maximum during the initial period. The ratio h/2a of the pit depth h to the pit diameter 2a varied from 0.04 to 0.13 in water and from 0.06 to 0.20 in mineral oil. Scanning electron microscopy indicates that the pits are initially formed over the grain boundaries and precipitates while the surface grains are deformed under cavitation attack.

Rao, B. C. S.↗

Calculated effects of varying Reynolds Number and dynamic pressure on flexible wings at transonic speeds

A computational method is described that includes the effects of static aeroelastic wing deflections in steady transonic aerodynamic calculations. This method, known as the Transonic Aero-elastic Program System (TAPS), interacts a 3D transonic computer code with boundary layer and a linear finite element structural analysis codes to calculate wing pressures and deflections. The nonlinear nature of the transonic flow makes it necessary to couple the aerodynamic and structures codes in an iterative manner. TAPS has been arranged in a modular fashion so that different aerodynamic or structures programs may be used with a minimum of coding changes required. Results obtained using two different aerodynamic codes in TAPS are given, and those results are correlated with experimental data.

Campbell, R. L.↗

Area postrema ablations in cats: Evidence for separate neural routes for motion- and xylazine-induced CTA and emesis

The effects of off-vertical rotation upon the Intake of tap water Immediately after rotation, and upon conditioned taste aversion, were assessed In mice with the tilt of the rotation axis varying from 5 to 20° from the earth-vertical. Conditioned taste aversion occurred In all mice that were rotated, but the Intake of tap water was suppressed only In mice that were rotated at 15 or 20° of tilt. The greater suppression of tap water Intake and the stronger conditioned aversion In the mouse as the angle of tilt was Increased In this experiment are consistent with predictions from similar experiments with human subjects where motion sickness develops more rapidly as the angle of tilt la Increased. It was suggested that off-vertical rotation may be a useful procedure for Insuring experimental control over vestibular stimulation In animal studies of motion sickness.

Robert A Fox↗