Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Heat transfer tests of an 0.006-scale thin skin space shuttle thermocouple model (41-0) in the Langley Research Center variable density tunnel at M equals 8 (OH13)

Orbiter entry heating distributions were obtained, and phase change paint data was correlated with thermocouple data during a program of heat transfer testing on a 0.006 scale space shuttle orbiter vehicle. The orbiter was tested at 0, 30, and 35 degrees angle of attack at Reynolds numbers of 1, 2, 3, 4, and 6 million per foot. Temperature data were obtained from a total of 57 thermocouples.

Walstad, D. G.↗

Welding thermocouples to columbium

Procedure developed for attaching thermocouples is simple and explicit. It includes such steps as preparing columbium surface by cleaning it, depositing globule of titanium, and remelting globule and inserting thermocouple wires in it.

Demonbrun, F. R.↗

Surface heat flux determination: An analytical and experimental study using a single embedded thermocouple

A numerical method by which data from a single embedded thermocouple can be used to predict the transient thermal environment for both high- and low-conductivity materials is described. The results of an investigation performed to verify the method clearly demonstrate that accurate, transient, surface heating conditions can be obtained from a thermocouple l.016 centimeters from the heating surface in a low-conductivity material. Space shuttle orbiter thermal protection system materials having temperature- and pressure-dependent properties, and typical orbiter entry heating conditions were used to verify the accuracy of the analytical procedure. Analytically generated, as well as experimental, data were used to compare predicted and measured surface temperatures.

Williams, S. D.↗

Miniature thermocouple disconnect

Commercially available subminiature connector modified for utilization with both flexible and small diameter metal-sheathed thermocouples results in reliable thermocouple for instrumentation on wind-tunnel models smaller than commercial disconnects normally used.

Quinn, K. L.↗

Crimped thermocouple connections

When proper procedures are followed, hand crimping tool makes reliable, low-cost thermocouple connections. Procedure reduces time and expense of splicing solid and stranded platinum thermocouple wires.

Billington, K. L.↗

Thermocouple, multiple junction reference oven

An improved oven for maintaining the junctions of a plurality of reference thermocouples at a common and constant temperature is described. The oven is characterized by a cylindrical body defining a heat sink with axially extended-cylindrical cavity a singularized heating element which comprises a unitary cylindrical heating element consisting of a resistance heating coil wound about the surface of metallic spool with an axial bore defined and seated in the cavity. Other features of the oven include an annular array of radially extended bores defined in the cylindrical body and a plurality of reference thermocouple junctions seated in the bores in uniformly spaced relation with the heating element, and a temperature sensing device seated in the axial bore for detecting temperature changes as they occur in the spool and circuit to apply a voltage across the coil in response to detected drops in temperatures of the spool.

Leblanc, L. P.↗

Self-heated thermocouples for far-infrared detection

A novel self-heated Bi-Sb thermocouple for far-infrared detection has been developed. The detector is suitable for integration with monolithic antennas and imaging arrays. The device is fabricated in a single photolithography masking step using a photoresist-bridge technique. This bridge technique has also been used to make microbolometers with lower 1/f noise than those made by two conventional masking steps. The thermocouples have a noise equivalent power of 7 x 10 to the -10th W/sq rt of Hz and a 3-dB frequency response of 150 kHz.

Neikirk, D. P.↗

Noncontacting Measurement With a Thermocouple

Tentlike covering brings thermocouple to within few degrees of surface temperature. Technique originally developed for measuring surface temperature of quartz fabric under radiant heating requires no direct contact with heated surface. Technique particularly useful when measuring surface temperatures of materials damaged if thermocouple or other temperature sensor attached.

Weatherill, W. T.↗

Advanced thin film thermocouples

The fabrication, materials characterization, and performance of thin film platinum rhodium thermocouples on gas turbine alloys was investigated. The materials chosen for the study were the turbine blade alloy systems MAR M200+Hf with NiCoCrAlY and FeCrAlY coatings, and vane alloy systems MAR M509 with FeCrAlY. Research was focussed on making improvements in the problem areas of coating substrate stability, adhesion, and insulation reliability and durability. Diffusion profiles between the substrate and coating with and without barrier coatings of Al2O3 are reported. The relationships between fabrication parameters of thermal oxidation and sputtering of the insulator and its characterization and performance are described. The best thin film thermocouples were fabricated with the NiCoCrAlY coatings which were thermally oxidized and sputter coated with Al2O3.

Kreider, K. G.↗

Thread-Mounted Thermocouple

Thread-mounted thermocouple developed to accurately measure temperature of surrounding material. Comprised of threaded rod or bolt drilled along length, dual-hole ceramic insulator rod, thermocouple wire, optional ceramic filler, and epoxy resin. In contact with and takes average temperature of, surrounding material. Fabricated easily in size and metal to suit particular application. Because of simplicity and ability to measure average temperature, widespread use of design foreseen in varity of applications.

Ward, Stanley W.↗

Lag compensation of optical fibers or thermocouples to achieve waveform fidelity in dynamic gas pyrometry

Fidelity of waveform reproduction requires constant amplitude ratio and constant time lag of a temperature sensor's indication, at all frequencies of interest. However, heat-transfer type sensors usually cannot satisfy these requirements. Equations for the actual indication of a thermocouple and an optical-fiber pyrometer are given explicitly, in terms of sensor and flowing-gas properties. A practical, realistic design of each type of sensor behaves like a first-order system with amplitude-ratio attenuation inversely proportional to frequency when the frequency exceeds the corner frequency. Only at much higher frequencies does the amplitude-ratio attenuation for the optical fiber sensor become inversely proportional to the square root of the frequency. Design options for improving the frequency response are discussed. On-line electrical lag compensation, using a linear amplifier and a passive compensation network, can extend the corner frequency of the thermocouple 100-fold or more; a similar passive network can be used for the optical-fiber sensor. Design details for these networks are presented.

Warshawsky, I.↗

Measuring Inhomogeneities In Thermocouple Wires

Spools rotated to pull thermocouple wires through liquid nitrogen, while output voltage of thermocouple recorded on strip chart. Wires exposed to severe temperature gradients, amounting to overall change of 200 degrees C, where they enter and leave liquid nitrogen. If wires homogeneous, net output voltage zero. If inhomogeneity passes through liquid-nitrogen/air interface, resulting deviation of output voltage from zero seen immediately on strip chart. If inhomogeneity greater than allowable, reels stopped temporarily so inhomogeneity tagged before wound onto takeup reel.

Burkett, Cecil G., Jr.↗

Heat flux measurements on ceramics with thin film thermocouples

Two methods were devised to measure heat flux through a thick ceramic using thin film thermocouples. The thermocouples were deposited on the front and back face of a flat ceramic substrate. The heat flux was applied to the front surface of the ceramic using an arc lamp Heat Flux Calibration Facility. Silicon nitride and mullite ceramics were used; two thicknesses of each material was tested, with ceramic temperatures to 1500 C. Heat flux ranged from 0.05-2.5 MW/m2(sup 2). One method for heat flux determination used an approximation technique to calculate instantaneous values of heat flux vs time; the other method used an extrapolation technique to determine the steady state heat flux from a record of transient data. Neither method measures heat flux in real time but the techniques may easily be adapted for quasi-real time measurement. In cases where a significant portion of the transient heat flux data is available, the calculated transient heat flux is seen to approach the extrapolated steady state heat flux value as expected.

Holanda, Raymond↗

Program Processes Thermocouple Readings

Digital Signal Processor for Thermocouples (DART) computer program implements precise and fast method of converting voltage to temperature for large-temperature-range thermocouple applications. Written using LabVIEW software. DART available only as object code for use on Macintosh II FX or higher-series computers running System 7.0 or later and IBM PC-series and compatible computers running Microsoft Windows 3.1. Macintosh version of DART (SSC-00032) requires LabVIEW 2.2.1 or 3.0 for execution. IBM PC version (SSC-00031) requires LabVIEW 3.0 for Windows 3.1. LabVIEW software product of National Instruments and not included with program.

Quave, Christine A.↗

Multiwire Thermocouples in Reversing Flow

Measurements are recorded for multiwire thermocouples consisting of either two or three wires of unequal diameters. Signals from the multiwire probe are recorded for a reversing gas flow with both a periodic temperature and time constant fluctuation. It is demonstrated that the reconstructed signal from the multiwire thermocouple requires no compensation provided omega/omega(sub 1) less than 2.3 for two wires or omega/omega(sub 1) less than 3.6 for three wires where omega(sub 1) (= 2(pi)f) is the natural frequency of the smaller wire based on the maximum gas velocity. The latter results were possible provided Fourier transformed data from the wires were used and knowledge of the gas velocity phase angle was available.

Forney, L. J.↗

Advances in Thin Film Thermocouple Durability Under High Temperature and Pressure Testing Conditions

Thin film thermocouples for measuring material surface temperature have been previously demonstrated on several material systems and in various hostile test environments. A well-developed thin film fabrication procedure utilizing shadow masking for patterning the sensors elements had produced thin films with sufficient durability for applications in high temperature and pressure environments that exist in air-breathing and hydrogen-fueled burner rig and engine test facilities. However, while shadow masking had been a reliable method for specimens with flat and gently curved surfaces, it had not been consistently reliable for use on test components with sharp contours. This work reports on the feasibility of utilizing photolithography processing for patterning thin film thermocouples. Because this patterning process required changes in the thin film deposition process from that developed for shadow masking, the effect of these changes on thin film adherence during burner rig testing was evaluated. In addition to the results of changing the patterning method, the effects on thin film adherence of other processes used in the thin film fabrication procedure is also presented.

Martin, Lisa C.↗

An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

Hwang, Danny P.↗

Thermocouple Extension-Wire-Connections and Low Temperatures

Experiments were carried out to determine the casue of erroneous readings from thermocouples of type K when measuring temperatures of liquid hydrogen. It was believed to be linked to te temperature of the connector used to extend the thermocouple wires to the voltage meter.

Figueroa, Fernando↗