Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMIONIC CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

An out-of-core thermionic-converter system for nuclear space power.

Reexamination of designs of nuclear thermionic space power systems with the converter outside the reactor in the perspective of recent advances in heat-transfer methods, materials, converter performance, and radiation design. The 40- to 70-kW(e) power range is treated. The configuration is found to meet the constraints of readily available launch vehicles. It allows for off-design operation including startup, shutdown, and possible emergency conditions; provides tolerance of failure by extensive use of modular, redundant elements; incorporates and uses heat pipes in a fashion that reduces the need for extensive in-pile testing of system components; and uses thermionic converters, nuclear fuel elements, and heat-transfer devices in a geometrical form adapted from existing incore thermionic system designs.

Breitwieser, R.↗

Computer controlled performance mapping of thermionic converters: effect of collector, guard-ring potential imbalances on the observed collector current-density, voltage characteristics and limited range performance map of an etched-rhenium, niobium planar converter

The effect of collector, guard-ring potential imbalance on the observed collector-current-density J, collector-to-emitter voltage V characteristic was evaluated in a planar, fixed-space, guard-ringed thermionic converter. The J,V characteristic was swept in a period of 15 msec by a variable load. A computerized data acquisition system recorded test parameters. The results indicate minimal distortion of the J,V curve in the power output quadrant for the nominal guard-ring circuit configuration. Considerable distortion, along with a lowering of the ignited-mode striking voltage, was observed for the configuration with the emitter shorted to the guard ring. A limited-range performance map of an etched-rhenium, niobium, planar converter was obtained by using an improved computer program for the data acquisition system.

Manista, E. J.↗

Some properties of low-vapor-pressure braze alloys for thermionic converters

Density, dc electrical resistivity, thermal conductivity, and linear thermal expansion are measured for arc-melted rod-shaped samples of binary eutectics of Zr, Hf, Ru, Nb, Ir, Mo, Ta, Os, Re, and W selected as very-low-pressure braze fillers for thermionic converters. The first two properties are measured at 296 K for Zr-21.7 at% Ru, Zr-13 wt% W, Zr-19 wt% W, Zr-22.3 at% Nb, Nb-66.9 at% Ru, Hf-25.3 wt% Re, Zr-25.7 at% Ta, Hf-22.5 at% W, and Nb-35 wt% Mo. The last property is measured from 293 K to 2/3 melting point for specified alloys of different compositions. Resistivities of 0.000055 to 0.000181 ohm-cm are observed with the alloys having resistivities about ten times that of the less resistive constituent metal and about three times that of the more resistive constituent metal, except for Zr-19 wt% W and Nb-35 wt% Mo (greater resistivities). Thermal expansion coefficients vary from 0.000006 to 0.0000105/K. All brazes exhibit linear thermal expansion near that of their constituent metals.

Bair, V. L.↗

Parametric testing of an externally configured thermionic converter

A 25.4-cm long externally configured converter was performance tested by electrically heating the emitter to simulate reactor thermal power input. The measured maximum output power was limited by the maximum input power available from the electric RF induction heater. With maximum heater input power, the converter electric output was 178 W (1.95 W/sq cm) at an emitter temperature of 1946 K. This electric output power was smaller than expected. A reactor-core-length (25.4-cm long) cylindrical thermionic converter power and maintaining the emitter-to-collector gap without shorting are of major importance to the feasibility of a 25.4-cm-long reactor fuel element. The emitter of the converter is located externally to the collector to increase the fuel-volume fraction and to allow redundant collector cooling in a reactor configuration.

Shimada, K.↗

Collector temperature effects on the performance of advanced thermionic converters and nuclear electric propulsion systems

The specific weight of a thermionic nuclear electric propulsion (NEP) system depends on the collector temperature because of changes in power density, efficiency and the temperature of heat rejection. Increasing the collector temperature above the value for maximum converter performance decreases both the efficiency and the power density of the converters, but the specific weight of the total system is decreased because of the reduction in radiator weight due to the increased heat rejection temperature. The effect of collector temperature on the performance of thermionic converters was investigated. The behavior of conventional ignited mode converters as well as advanced converters with lower collector work functions; the specific mass of an 'uninsulated' NEP system design was then evaluated as a function of collector temperature. The uninsulated design uses the electrical resistance of the heat pipes between the converters and the reactor to provide electrical insolation, eliminating the need for ceramic insulators at emitter temperature and providing other design advantages. The results indicate that an optimum collector temperature, which minimizes system weight, exists at a temperature above the optimum temperature for converter performance.

Dick, R. S.↗

Work function determination of promising electrode materials for thermionic converters

Work performed on this contract was primarily for the evaluation of selected electrode materials for thermionic energy converters. The original objective was to characterize selected nickel based superalloys up to temperatures of 1400 K. It was found that an early selection, Inconel 800 produced a high vapor pressure which interfered with the vacuum emission measurements. The program then shifted to two other areas. The first area was to obtain emission from the superalloys in a cesiated atmosphere. The cesium plasma helps to suppress the vaporization interference. The second area involved characterization of the Lanthanum-Boron series as thermionic emitters. These final two areas resulted in three journal publications which are attached to this report.

Jacobson, D.↗

Experimental and theoretical investigation for the suppression of the plasma arc drop in the thermionic converter

Ion generation and recombination mechanisms in the cesium plasma as they pertain to the advanced mode thermionic energy converter were studied. The decay of highly ionized cesium plasma was studied in the near afterglow to examine the recombination processes. Very low recombination in such a plasma may prove to be of considerable importance in practical converters. The approaches of external cesium generation were vibrationally excited nitrogen as an energy source of ionization of cesium ion, and microwave power as a means of resonant sustenance of the cesium plasma. Experimental data obtained so far show that all three techniques - i.e., the non-LTE high-voltage pulsing, the energy transfer from vibrationally excited diatomic gases, and the external pumping with a microwave resonant cavity - can produce plasmas with their densities significantly higher than the Richardson density. The implication of these findings as related to Lam's theory is discussed.

Shaw, D. T.↗

Fabrication and life testing of thermionic converters

An unfueled converter containing a chloride-fluoride duplex tungsten emitter of 4.78 eV vacuum work function was tested for 46,647 hours at an emitter temperature of 1973 K and an electrode power output of about 8 watts/sq cm. The test demonstrated the superior and stable performance of the (110) oriented tungsten emitter at high temperatures. Three 90 UC-10 ZrC(C/U = 1.04, tungsten additive = 4 wt %) fueled converters were fabricated and tested at an emitter temperature of 1873 K. Converter containing chloride-arc-cast duplex tungsten cladding showed temperature thermionic performance and slower rate of performance drop than converter containing chloride-fluoride duplex tungsten cladding. This is believed to be due to the superior fuel component diffusion resistance of the arc-cast tungsten substrate used in the fuel cladding. It was shown that a converter containing a carbide fueled chloride-arc-cast duplex tungsten emitter with an initial electrode power output of 6.80 watts/sq cm could still deliver an electrode power output of 6.16 watts/sq cm after 18,632 hours of operation at an emitter temperature of 1873 K.

Yang, L.↗

Performance tests of a thermionic converter with an oxygenated cesium reservoir

Cesium oxide/cesium solutions as a possible source of oxygen and cesium are investigated. A converter-reservoir system which allows multiple additions of oxygen with intervening thermionic performance tests was developed. The experimental data cover the cesium oxide mole fraction range of 0 to 0.018 with thermionic performance measurements in the emitter temperature range of 1600 to 1900 K. The data showed that the thermionic performance was unaffected by the presence of cesium oxide in this mole fraction range and higher mole fractions appear to be required for the proper oxygen arrival rate at the emitter surface.

Gunther, B.↗

Correlation between nonequilibrium thermodynamic theory and V-I curves of a thermionic converter

The methods of irreversible thermodynamics are used as a basis for developing a transport theory applicable to thermionic cesium diodes. This theory is applied in describing certain aspects of experimental voltage-current (V-I) characteristic curves of a thermionic diode. Emphasis is placed on the open-circuit voltage and short-circuit current of the V-I curves. Experimental results show that the open-circuit voltage is essentially independent of the interelectrode spacing, whereas the short-circuit current varies inversely with the interelectrode separation. The inverse dependence is in agreement with the results of the present analysis and also with results expected from diffusion theory, which has been used in other analyses. In fact, the theory used in this investigation reduces to diffusion theory under special assumptions. Deviations from diffusion theory, which were found in experimental results, can be accounted for using the theory developed in this paper.

Robinson, L. B.↗

NASA thermionic converter research and technology program

This paper describes the NASA/ERDA research and technology program that was initiated in mid-FY 1974 with the objective of doubling the efficiency of thermionic power conversion with decreased emitter temperature. Also discussed are the potential uses of thermionic power conversion systems. Emphasis in this paper is placed on potential space applications, especially nuclear-electric propulsion (NEP). Possible development schedules are shown that would allow NEP systems to be ready for use in the 1990 time period for missions to the outer planets.

Lundholm, J. G.↗