Engineering PapersSearch

SEARCH · Engineering Papers

Results for “TESS Mission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

139 records · Page 8

Performance of an X-ray Microcalorimeter with a 240 μm Absorber and a 50 μm TES Bilayer

Superconducting transition-edge sensor (TES) microcalorimeters are being developed for a variety of potential astrophysics missions, including Athena. The X-ray integral field unit instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. In this work, we describe a new approach with 50 μm square TESs consisting of a Mo/Au bilayer, deposited on silicon nitride membranes to provide a weak thermal conductance to a ~50 mK heat bath. Larger TESs usually have additional normal metal stripes on top of the bilayer to reduce the noise. However, we have found that excellent spectral performance can be achieved without the need for any normal metal stripes on top of the TES. A spectral performance of 1.58+/-0.12 eV at 5.9 keV has been achieved, the best resolution seen in any of our devices with this pixel size.

Miniussi, Antoine R.

The Primordial Anisotropy Polarization Pathfinder Array (PAPPA): Instrument Overview and Status

PAPPA is a balloon-based experiment designed to measure the polarization of the Cosmic Microwave Background using candidate technology for an eventual Inflation Probe mission. It will survey a 20 x 20 degree patch of sky with 1 degree angular resolution covering 3 passbands centered at 100,200 and 300 GHz. Detection will be accomplished via antenna-coupled transition edge sensors (TESs) with SQUID-based readouts. In the eventual flight package, band defining filters and MEMS-based polarization modulators will be incorporated into the superconducting microstrip transmission lines that terminate in resistors that are thermally coupled to the TESs. The MEMS switches will allow on-chip polarization modulation that is faster than significant detector gain variations. The initial configuration will incorporate a simplified focal plane augmented by quasioptical polarization modulation. We describe the overall instrument design and present a summary of the current progress.

Chuss, David

Predictable Patterns in Planetary Transit Timing Variations and Transit Duration Variations Due to Exomoons

We present new ways to identify single and multiple moons around extrasolar planets using planetary transit timing variations (TTVs) and transit duration variations (TDVs). For planets with one moon, measurements from successive transits exhibit a hitherto undescribed pattern in the TTV-TDV diagram, originating from the stroboscopic sampling of the planet's orbit around the planet-moon barycenter. This pattern is fully determined and analytically predictable after three consecutive transits. The more measurements become available, the more the TTV-TDV diagram approaches an ellipse. For planets with multiple moons in orbital mean motion resonance (MMR), like the Galilean moon system, the pattern is much more complex and addressed numerically in this report. Exomoons in MMR can also form closed, predictable TTV-TDV figures, as long as the drift of the moons' pericenters is suciently slow.We find that MMR exomoons produce loops in the TTV-TDV diagram and that the number of these loops is equal to the order of the MMR, or the largest integer in the MMR ratio.We use a Bayesian model and Monte Carlo simulations to test the discoverability of exomoons using TTV-TDV diagrams with current and near-future technology. In a blind test, two of us (BP, DA) successfully retrieved a large moon from simulated TTV-TDV by co-authors MH and RH, which resembled data from a known Kepler planet candidate. Single exomoons with a 10 percent moon-to-planet mass ratio, like to Pluto-Charon binary, can be detectable in the archival data of the Kepler primary mission. Multi-exomoon systems, however, require either larger telescopes or brighter target stars. Complementary detection methods invoking a moon's own photometric transit or its orbital sampling effect can be used for validation or falsification. A combination of TESS, CHEOPS, and PLATO data would offer a compelling opportunity for an exomoon discovery around a bright star.

stroboscopic sampling

A Detailed Analysis of the Gl 486 Planetary System

Context . The Gl 486 system consists of a very nearby, relatively bright, weakly active M3.5V star at just 8 pc with a warm transiting rocky planet of about 1.3 R ⨁ and 3.0 M ⨁ . It is ideal for both transmission and emission spectroscopy and for testing interior models of telluric planets. Aims . To prepare for future studies, we aim to thoroughly characterise the planetary system with new accurate and precise data collected with state-of-the-art photometers from space and spectrometers and interferometers from the ground. Methods . We collected light curves of seven new transits observed with the CHEOPS space mission and new radial velocities obtained with MAROON-X at the 8.1m Gemini North telescope and CARMENES at the 3.5m Calar Alto telescope, together with previously published spectroscopic and photometric data from the two spectrographs and TESS. We also performed near-infrared interferometric observations with the CHARA Array and new photometric monitoring with a suite of smaller telescopes (AstroLAB, LCOGT, OSN, TJO). This extraordinary and rich data set was the input for our comprehensive analysis. Results . From interferometry, we measure a limb-darkened disc angular size of the star Gl 486 at θ LDD = 0.390 ± 0.018 mas. Together with a corrected Gaia EDR3 parallax, we obtain a stellar radius R * = 0.339 ± 0.015 R ⨀ . We also measure a stellar rotation period at P rot = 49.9 ± 5.5 days, an upper limit to its XUV (5–920 Å) flux informed by new Hubble/STIS data, and, for the first time, a variety of element abundances (Fe, Mg, Si, V, Sr, Zr, Rb) and C/O ratio. Moreover, we imposed restrictive constraints on the presence of additional components, either stellar or sub-stellar, in the system. With the input stellar parameters and the radial-velocity and transit data, we determine the radius and mass of the planet Gl 486 b at R p = 1.343 +0.063 -0.062 R ⨀ and M p = 3.00 +0.13 -0.13 M ⨁ , with relative uncertainties of the planet radius and mass of 4.7% and 4.2%, respectively. From the planet parameters and the stellar element abundances, we infer the most probable models of planet internal structure and composition, which are consistent with a relatively small metallic core with respect to the Earth, a deep silicate mantle, and a thin volatile upper layer. With all these ingredients, we outline prospects for Gl 486 b atmospheric studies, especially with forthcoming James Webb Space Telescope (Webb) observations.

Planetary systems

Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

Zhou, Dazhuang

Integration of Multilevel Superconducting Buried Wiring Layers with Transition-Edge Sensor Detectors for Large Scale Arrays

Lynx, one of the four mission concepts under consideration for the next Astrophysics DecadalReview, will include a microcalorimeter array consisting of more than 100,000 pixels in a compact arrangement with absorber pitch as small as 25 microns. In order to realize the desired array scale, fine-pitch multi-level superconducting wiring with high yield, compatible with rapid expansion of our hydra absorber designs, is essential. We have demonstrated a method of integrating transition edge sensor (TES) microcalorimeters with suitable multilevel buried wiring, fabricated at MIT Lincoln Laboratory using advanced tools dedicated to superconducting circuit fabrication. The TES Mo/Au bilayer is deposited on a high-quality oxide surface created by chemical-mechanical polishing, allowing tight specifications on the TES superconducting transition and link conductivity to be achieved even though the process order has been inverted. The TESs contact the top-level niobium wiring through vias etched through silicon dioxide down to the topmost wiring layer. The article discusses the overall fabrication process, as wellas the behavior of sensors with different via designs, proximity structures, and lateral sizes. An initial iteration of the integrated fabrication process indicates that microcalorimeters fabricated in this way should meet mission specifications using a Mo/Au bilayer with a reasonable critical temperature below 100 mK.

Detector

HPIC: The Habitable Worlds Observatory Preliminary Input Catalog

The Habitable Worlds Observatory Preliminary Input Catalog (HPIC) is a list of ∼13,000 nearby bright stars that will be potential targets for the Habitable Worlds Observatory (HWO) in its search for Earth-sized planets around Sun-like stars. We construct this target list using the TESS and Gaia DR3 catalogs and develop an automated pipeline to compile stellar measurements and derived astrophysical properties for all stars. We benchmark the stellar properties in the HPIC relative to those of the manually curated ExEP HWO Precursor Science Stars list and find that, for the 164 best targets for exo-Earth direct imaging, our stellar properties are consistent. We demonstrate the utility of the HPIC by using it as an input for yield calculations to predict the science output of various mission designs, including those with larger telescope diameters and those focused on other planet types besides Earth analogs, such as Jupiter-mass planets. The breadth and completeness of the HPIC is essential for accurate HWO mission trade studies, and it will be useful for other exoplanet studies and general astrophysics studying the population of bright nearby stars.

Noah W. Tuchow

X-Ray Missions Based on LTD Technologies

Microcalorimeter arrays used as imaging spectrometers will enable ground-breaking science in X-ray astrophysics. Their development has been one of the driving applications of the low temperature detector community since the early 1980s. While their application in space remains in relative infancy, we are on the verge of an era in which microcalorimeter spectrometers are likely to dominate instrumentation for high-energy astrophysics missions. NASA sounding rocket experiments such as the X-ray Quantum Calorimeter (XQC) and Micro-X have now paved the way for orbital observatories. JAXA’s Astro-H gave us a glimpse of this fantastic new capability before its unfortunate demise. The launch of XRISM later this year should finally demonstrate the sort of large suite of observations that X-ray microcalorimeter arrays will make major contributions to. In the mid-2030s, we will see the launch of ESA’s flagship Athena mission, that will further advance the imaging and spectroscopic capabilities for the high-energy X-ray community enormously. Numerous other potential new mission concepts using X-ray microcalorimeters have been studied in detail such as NASA’s Lynx and the Light Element Mapper (LEM), JAXA’s Super-DIOS, and China’s Hot Universe Baryon Surveyor (HUBS). In the first half of this presentation, I will review the development and desired requirements of the X-ray microcalorimeter missions and concepts, and describe the current progress and status missions being implemented and proposed. In the second half of this presentation, I will focus on The Line Emission Mapper (LEM) which is a probe-class mission concept under study by NASA that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight X-ray optic with 10” angular resolution and a large-format microcalorimeter array with a 15” pixel pitch over a 29’ field of view (FOV). The main microcalorimeter array and readout design takes advantage of mature technology that has been developed for Athena X-IFU. The central 7’ region of the array consists of ~ 800 transition-edge sensors (TESs), optimized for a bandpass of 0.3-2 keV and with an energy resolution of 1.2 eV at 1 keV. The rest of the FOV is covered by 4-pixel TES hydras with 2.5 eV energy resolution at 1 keV. Hydras are position-sensitive (‘thermally multiplexed’) detectors that enable extremely large numbers of effective pixels in an array, without a commensurate increase in the number of wires, bias circuit, and readout components. In total the array will have ~ 4k TESs with ~ 14k imaging elements on a 290 micron-pitch. The array will be read out with state-of-the-art time-division multiplexing (TDM), implement with 59 pixels (and 1 dark pixel) in each of the 69 TDM columns. Here we present a detailed overview of the baseline microcalorimeter detector design and present first results from both single pixel TESs and 4-pixel hydras. Our prototype LEM pixels utilize 15um x 50um Mo/Au TESs with a transition temperature of around 58 mK. These pixels incorporate high-fill-factor Au absorbers of thickness 0.54um. We have demonstrated an energy resolution of 0.90+/-0.02 eV and 1.90 +/-0.02 eV at 1.5 keV for single pixel and 4-pixel hydras, respectively, meeting the performance requirements of LEM. We show how the position discrimination in the hydra pixels can be achieved, down to energies of a few 100 eV, using the measured pulse rise-times. Finally, we will show that the properties of the LEM pixels are well optimized for the proposed TDM read out architecture.

Simon Richard Bandler

NASA's Work in Exoplanet Hunting Satellites and Robotic Servicing of Satellites

An overview of three missions connected with NASA's Goddard Space Flight Center at the present time: (1) NASA's flagship mission, the James Webb Space Telescope, is nearing its 2021 launch date. The James Webb, which is considered the successor to the Hubble Space Telescope, will orbit at the Earth-Sun Lagrangian Point Two where it will peer back in time, using infrared detectors, to the beginnings of our Universe. (2) NASA is conducting pioneering work in the field of robotic satellite servicing in earth orbit. The RESTORE-L project, which is slated for a 2021 launch date, is expected to pave the way for the inception of robotic assembly for deep space exploration as well as the commercialization of satellite servicing. (3) The Transiting Exoplanet Survey Satellite (TESS) has been orbiting the Earth actively searching for new planets since April of 2018. The discoveries that TESS has made to-date have benefited from a careful characterization of the refractive lens assemblies on its science instruments. The presentation will provide a detailed description of how the index of refraction of the glasses used to fabricate the TESS lens assemblies were measured at Goddard to an accuracy that enables the ability to make exoplanet discoveries hundreds of light years from Earth.

Miller, Kevin H.

Combining Photometry from Kepler and TESS to Improve Short-Period Exoplanet Characterization

Planets emit thermal radiation and reflect incident light that they receive from their host stars. As a planet orbits its host star the photometric variations associated with these two effects produce very similar phase curves. If observed through only a single bandpass, this leads to a degeneracy between certain planetary parameters that hinder the precise characterization of such planets. However, observing the same planet through two different bandpasses gives much more information about the planet. Here we develop a Bayesian methodology for combining photometry from both Kepler and the Transiting Exoplanet Survey Satellite. In addition, we demonstrate via simulations that one can disentangle the reflected and thermally emitted light from the atmosphere of a hot-Jupiter as well as more precisely constrain both the geometric albedo and day-side temperature of the planet. This methodology can further be employed using various combinations of photometry from the James Webb Space Telescope, the Characterizing ExOplanet Satellite, or the PLATO mission.

photometric variations

Advances in Small Pixel TES-Based X-Ray Microcalorimeter Arrays for Solar Physics and Astrophysics

We are developing small-pixel transition-edge-sensor (TES) for solar physics and astrophysics applications. These large format close-packed arrays are fabricated on solid silicon substrates and are designed to accommodate count-rates of up to a few hundred counts/pixel/second at a FWHM energy resolution approximately 2 eV at 6 keV. We have fabricated versions that utilize narrow-line planar and stripline wiring. We present measurements of the performance and uniformity of kilo-pixel arrays, incorporating TESs with single 65-micron absorbers on a 7s-micron pitch, as well as versions with more than one absorber attached to the TES, 4-absorber and 9-absorber "Hydras". We have also fabricated a version of this detector optimized for lower energies and lower count-rate applications. These devices have a lower superconducting transition temperature and are operated just above the 40mK heat sink temperature. This results in a lower heat capacity and low thermal conductance to the heat sink. With individual single pixels of this type we have achieved a FWHM energy resolution of 0.9 eV with 1.5 keV Al K x-rays, to our knowledge the first x-ray microcalorimeter with sub-eV energy resolution. The 4-absorber and 9-absorber versions of this type achieved FWHM energy resolutions of 1.4 eV and 2.1 eV at 1.5 keV respectively. We will discuss the application of these devices for new astrophysics mission concepts.

Bandler, S. R.

Development of arrays of position-sensitive microcalorimeters for Constellation-X

We are developing arrays of position-sensitive transition-edge sensor (POST) X-ray detectors for future astronomy missions such as NASA's Constellation-X. The POST consists of multiple absorbers thermally coupled to one or more transition-edge sensor (TES). Each absorber element has a different thermal coupling to the TES. This results in a distribution of different pulse shapes and enables position discrimination between the absorber elements. POST'S are motivated by the desire to achieve the largest possible focal plane area with the fewest number of readout channels and are ideally suited to increasing the Constellation-X focal plane area, without comprising on spatial sampling. Optimizing the performance of POST'S requires careful design of key parameters such as the thermal conductances between the absorbers, TES and the heat sink. as well as the absorber heat capacities. Using recently developed signal processing algorithms we have investigated the trade-off between position-sensitivity, energy resolution and pulse decay time. based on different device design parameters for PoST's. Our new generation of PoST's utilize technology successfully developed on high resolution (approximately 2.5eV) single pixels arrays of Mo/Au TESs. also under development for Constellation-X. This includes noise mitigation features on the TES and low resistivity electroplated absorbers. We report on the first experimental results from these new one and two-channel PoST"s, consisting of all Au and composite Au/Bi absorbers, which are designed to achieve an energy resolution of < 10 eV. coupled with count-rates of 100's per pixel per second and position sensitivity over the energy range 0.3-10 keV.

Smith, S. J.

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics