Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TCP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

On the use of biomathematical models in patient-specific IMRT dose QA

Purpose: To investigate the use of biomathematical models such as tumor control probability (TCP) and normal tissue complication probability (NTCP) as new quality assurance (QA) metrics.Methods: Five different types of error (MLC transmission, MLC penumbra, MLC tongue and groove, machine output, and MLC position) were intentionally induced to 40 clinical intensity modulated radiation therapy (IMRT) patient plans (20 H and N cases and 20 prostate cases) to simulate both treatment planning system errors and machine delivery errors in the IMRT QA process. The changes in TCP and NTCP for eight different anatomic structures (H and N: CTV, GTV, both parotids, spinal cord, larynx; prostate: CTV, rectal wall) were calculated as the new QA metrics to quantify the clinical impact on patients. The correlation between the change in TCP/NTCP and the change in selected DVH values was also evaluated. The relation between TCP/NTCP change and the characteristics of the TCP/NTCP curves is discussed.Results:{Delta}TCP and {Delta}NTCP were summarized for each type of induced error and each structure. The changes/degradations in TCP and NTCP caused by the errors vary widely depending on dose patterns unique to each plan, and are good indicators of each plan's 'robustness' to that type of error.Conclusions: In this in silico QA study the authors have demonstrated the possibility of using biomathematical models not only as patient-specific QA metrics but also as objective indicators that quantify, pretreatment, a plan's robustness with respect to possible error types.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-319: The Effect of Slice Thickness On IMRT Planning

Purpose: The accuracy of volume estimated of a treatment planning system is investigated in this study. In addition, the effect of slice thickness on IMRT planning is also studied. Methods: The accuracy in volume determination was investigated using a water phantom containing various objects with known volumes ranging from 1–100cm{sup 3}. The phantom was scanned with different slice thickness (1–10 mm). The CT data sets were sent to Eclipse TPS for contour delineation and volume calculation. The effect of slice thickness on IMRT planning was studied using a commercial phantom containing four different shaped objects. The phantom was scanned with different slice thickness (1–5 mm). IMRT plans were generated for the different CT datasets to calculate TCP, homogeneity (HI) and conformity indices (CI). Results: The variability of volumes with CT slice thickness was significant especially for small volume structures. The minimum and maximum error in the volume estimation is in the range of −2.3% to 92%. On the other hand, with increasing slice thickness, the PTV mean dose and TCP values decreases. Maximum variation of ∼5% was observed in mean dose and ∼2% in TCP with slice thickness change from 1–5 mm. The relative decrease in target volume receiving 95% of prescribed dose is ∼5% slice thickness change from 1–5 mm. HI increases up to 163% and CI decreases by 4% between 1–5 mm slice thickness change, producing highly inhomogeneous and least conformal plan. Conclusion: Accuracy of volume estimation is dependent on CT slice thickness and the contouring algorithm in a TPS. During TPS commissioning and for all clinical protocols, evaluation of volume should be included to provide the limit of accuracy in DVH calculation. A smaller slice thickness provides superior dosimetry with improved TCP values. Thus, the smallest possible slice thickness should be used for IMRT planning.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-135: Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy

Purpose: To estimate the clinical relevance of approximations made in analytical dose calculation methods (ADCs) used for treatment planning on tumor coverage and tumor control probability (TCP) in proton therapy. Methods: We compared dose distributions planned with ADC to delivered dose distributions (as determined by TOPAS Monte Carlo (MC) simulations). We investigated 10 patients per site for 5 treatment sites (head-and-neck, lung, breast, prostate, liver). We evaluated differences between the two dose distributions analyzing dosimetric indices based on the dose-volume-histograms, the γ-index and the TCP. The normal tissue complication probability (NTCP) was estimated for the bladder and anterior rectum for the prostate patients. Results: We find that the target doses are overestimated by the ADC by 1–2% on average for all patients considered. All dosimetric indices (the mean dose, D95, D50 and D02, the dose values covering 95%, 50% and 2% of the target volume, respectively) are predicted within 5% of the delivered dose. A γ-index with a 3%/3mm criteria had a passing rate for target volumes above 96% for all patients. The TCP predicted by the two algorithms was up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head-and-neck and lung patients, respectively. Differences in NTCP for anterior-rectum and bladder for prostate patients were less than 3%. Conclusion: We show that ADC provide adequate dose distributions for most patients, however, they can Result in underdosage of the target by as much as 5%. The TCP was found to be up to 11% lower than predicted. Advanced dose-calculation methods like MC simulations may be necessary in proton therapy to ensure target coverage for heterogeneous patient geometries, in clinical trials comparing proton therapy to conventional radiotherapy to avoid biases due to systematic discrepancies in calculated dose distributions, and, if tighter range margins are considered. Fully funded by NIH grants.

60 APPLIED LIFE SCIENCES↗

Data Transfer Efficiency Over Satellite Circuits Using a Multi-Socket Extension to the File Transfer Protocol (FTP)

In several experiments using NASA's Advanced Communications Technology Satellite (ACTS), investigators have reported disappointing throughput using the transmission control protocol/Internet protocol (TCP/IP) protocol suite over 1.536Mbit/sec (T1) satellite circuits. A detailed analysis of file transfer protocol (FTP) file transfers reveals that both the TCP window size and the TCP 'slow starter' algorithm contribute to the observed limits in throughput. In this paper we summarize the experimental and and theoretical analysis of the throughput limit imposed by TCP on the satellite circuit. We then discuss in detail the implementation of a multi-socket FTP, XFTP client and server. XFTP has been tested using the ACTS system. Finally, we discuss a preliminary set of tests on a link with non-zero bit error rates. XFTP shows promising performance under these conditions, suggesting the possibility that a multi-socket application may be less effected by bit errors than a single, large-window TCP connection.

Allman, Mark↗

The Effect of Alloying on Topologically Close Packed Phase Instability in Advanced Nickel-Based Superalloy Rene N6

An investigation was conducted to describe topologically close packed (TCP) phase instability as a function of composition in the advanced Ni-base superalloy Rene N6. TCP phases are detrimental to overall high-temperature performance of Ni-base superalloys because of their brittle nature and because they deplete the Ni-rich matrix of potent solid solution strengthening elements. Thirty-four variations of polycrystalline Rene N6 determined from a design-of-experiments approach were cast and homogenized at 1315"C for 80 hours followed by exposure at 10930C for 400 hours to promote TCP formation. The alloys had the following composition ranges in atomic percent: Co 10.61 to 16.73%, Mo 0.32 to 1.34%, W 1.85 to 2.52%, Re 1.80 to 2.1 1 %, Ta 2.36 to 3.02%, Al 11.90 to 14.75%, and Cr 3.57 to 6.23%. Physical and chemical characteristics of all n-ticrostructures obtained were described using various analytical techniques. From these observations, a mathematical description of TCP occurrence (omega and P phase) was generated for polycrystalline Rene N6.

Ritzert, Frank↗

Investigation of the Formation of Topologically Close Packed Phase Instabilities in Nickel-Based Superalloy Rene N6

Topologically close packed (TCP) phase instability in third generation Ni-base superalloys is understood to hinder component performance when used in high-temperature jet engine applications. The detrimental effects on high temperature performance from these brittle phases includes weakening of the Ni-rich matrix through the depletion of potent solid solution strengthening elements. Thirty-four compositional variations of polycrystalline Rene N6 were defined from a design-of-experiments approach and then cast, homogenized, and finally aged to promote TCP formation. Our prior work reported on the results of the multiple retression modeling of these alloys in order to predict the volume fraction of TCP. This paper will present further regression modeling results on these alloys in order to predict the occurrence of TCP in third generation Ni-base superalloy microstructures. Kinetic results are also discussed.

Ritzert, Frank↗

Protocol Support for a New Satellite-Based Airspace Communication Network

We recommend suitable transport protocols for an aeronautical network supporting Internet and data services via satellite. We study the characteristics of an aeronautical satellite hybrid network and focus on the problems that cause dramatically degraded performance of the Transport Protocol. We discuss various extensions to standard TCP that alleviate some of these performance problems. Through simulation, we identify those TCP implementations that can be expected to perform well. Based on the observation that it is difficult for an end-to-end solution to solve these problems effectively, we propose a new TCP-splitting protocol, termed Aeronautical Transport Control Protocol (AeroTCP). The main idea of this protocol is to use a fixed window for flow control and one duplicated acknowledgement (ACK) for fast recovery. Our simulation results show that AeroTCP can maintain higher utilization for the satellite link than end-to-end TCP, especially in high BER environment.

Shang, Yadong↗

Using Transmission Control Protocol in the Trans-Pacific High Definition Video Satellite Communication Experiment - the Next Test

Ths paper describes a future Transmission Control Protocol (TCP) test which was planned as a part of the Trans-Pacific High Definition Video Satellite Communications Experiment. The TCP test portion of the Trans-Pacific High Definition Video Satellite Communications Experiment intends to examine the correlation between the underlying assumptions of come TCP algorithms and the performance shortfalls observed when the algorithms are used in a stellite-based environment, and to make experimental changes to existing TCP variants to study the effects of the modifications.

global information infrastructure (GII) satellites↗

System and method for implementing periodic early discard in on-chip buffer memories of network elements

An advance is made over the prior art in accordance with the principles of the present invention that is directed to a new approach for a system and method for a buffer management scheme called Periodic Early Discard (PED). The invention builds on the observation that, in presence of TCP traffic, the length of a queue can be stabilized by selection of an appropriate frequency for packet dropping. For any combination of number of TCP connections and distribution of the respective RTT values, there exists an ideal packet drop frequency that prevents the queue from over-flowing or under-flowing. While the value of the ideal packet drop frequency may quickly change over time and is sensitive to the series of TCP connections affected by past packet losses, and most of all is impossible to compute inline, it is possible to approximate it with a margin of error that allows keeping the queue occupancy within a pre-defined range for extended periods of time. The PED scheme aims at tracking the (unknown) ideal packet drop frequency, adjusting the approximated value based on the evolution of the queue occupancy, with corrections of the approximated packet drop frequency that occur at a timescale that is comparable to the aggregate time constant of the set of TCP connections that traverse the queue.

97 MATHEMATICS AND COMPUTING↗

Update on Plans for Treatment of Research Reactor Used Fuels at La Hague - 19507

Over the past decades, Orano (formerly AREVA) has been transporting, unloading, storing, and reprocessing research reactor spent fuel (RRSF) in its French facilities and with its equipment. This experience has resulted in the transportation and industrial-scale reprocessing of over 23 tons of RRSF (mainly of the Al type) at Orano's facilities in France, both in the Marcoule and the La Hague plants. In order to meet its customers growing needs in terms of RRSF management, Orano is developing new RRSF reprocessing capacities for the La Hague UP2-800 facility utilizing the lessons learned from the reprocessing of the current RRSF. This new facility is called the Traitement des Combustibles Particuliers or TCP and was introduced last year. The TCP is planned to reprocess several types of RRSF, including both Al and U{sub 3}Si{sub 2} RRSF, and in the future may also be useful in the support of reprocessing LWR and fast reactor MOX fuels. The focus of the TCP is on developing shearing and dissolution processes for these fuel types that can be incorporated into, and operated along with, the existing La Hague facilities. This paper will cover each of the stages of the current reprocessing of RRSF at La Hague from its transportation to La Hague to its post-reprocessing vitrified waste production, provide an update on its status, and identifying the areas where the TCP will better facilitate the reprocessing of the RRSF. Ultimately, this paper illustrates the innovative solutions available to modify existing recycling/reprocessing facilities to address pseudo-unique used nuclear fuel (UNF) forms to improve/simplify back-end UNF management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Radiation Cross-Talk Effects on Biological Dose Rates in Maintenance Areas Inside the ITER Tokamak - Paper 107

The intense plasma neutron source of ITER requires careful consideration of radiation safety during the design of the machine, its operation plan and licensing process. One important issue is that of occupational radiation exposure (ORE) during in-situ maintenance activities inside the cryostat, and particularly in the port inter-space area (PI) where up keeping of port systems should take place (diagnostics, tritium breeding test modules, heating antennas). ITER ports and port plugs (PP) become activated by neutron irradiation during plasma operation; from the subsequent decay and gamma emission of irradiated materials, the so-called shutdown dose rate field (SDR) appears. A project requirement of 100 uSv/h after 12 days exists for the SDR in the PI in order to limit exposure during maintenance and meet ORE regulatory limits. This requirement is particularly challenging for equatorial ports (EP) due to, among others, background neutron radiation and activation from/by neighbouring components (a.k.a. 'cross-talk'), and particularly the lower ports (LP). For a particular port inter-space, the SDR field is a combination of: (i) the gamma dose due to the activation of components local to the PI, typically referring to the PI itself plus the port plug, port duct and bellows, vessel extension and blankets in its vicinity; (ii) the gamma dose due to activation of components far away from the PI, a.k.a. the cross-talk, which typically refers to other ports, cryostat and rest of the vacuum vessel and blankets. The situation is complicated to some extent by the fact that both these components can arise from a combination of irradiation by local neutrons, i.e. those permeating through the vicinity of the port itself, and by cross-talk neutrons, i.e. those permeating via other paths. In simple terms, the so-called 'neutron cross-talk' refers to neutron leakage through other ports and components producing activation, decay gammas and dose locally in the PI of interest, whereas the 'gamma cross-talk' refers to activation and decay gammas in other ports producing dose in the PI from far away. The study reported here focuses on the evaluation of the effect of radiation cross-talk from a torus cryopump (TCP) LP located directly underneath a generic diagnostics equatorial port plug (DEPP) in the equatorial port itself. This is considered the worst case scenario, as the TCP-LP has a large aperture and has to be mostly empty in order to meet TCP pumping requirements. For the reference case and R1, the neutron cross-talk from the LP activating the EP is responsible for 109 uSv/h. In addition, a gamma cross-talk of 51 uSv/h from LP activation has been found. The total cross-talk contribution is therefore responsible for 160 uSv/h of SDR at EP PI. The local SDR contribution, i.e. that from activation of the EP with 'local-only' neutrons, is 166 uSv/h. The total SDR at R1 is 360 uSv/h, including some minor contributions from the UP, lateral EPs, cryostat and bio-shield. The total SDR at R2 is 349 uSv/hr, with a cross-talk contribution of 203 uSv/h. In R2 the gamma cross-talk is more intense, as it is closer to the highly activated TCPH. These results illustrate how the SDR field produced by radiation cross-talk through a TCP-LP is comparable in magnitude with that produced by neutron leakage and activation local to the EP. Shielding options are currently under consideration. Local gamma shielding at the EP PI is found to be effective in reducing gamma cross-talk from the LP and TCPH, and also in reducing the local contribution from the port duct and bellows. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-202-11: Radiobiological Modeling of Tumor Response During Radiotherapy Based On Pre-Treatment Dynamic PET Imaging Data

Purpose: To evaluate the ability of a multiscale radiobiological model of tumor response to predict mid-treatment hypoxia images, based on pretreatment imaging of perfusion and hypoxia with [18-F]FMISO dynamic PET and glucose metabolism with [18-F]FDG PET. Methods: A mechanistic tumor control probability (TCP) radiobiological model describing the interplay between tumor cell proliferation and hypoxia (Jeong et al., PMB 2013) was extended to account for intra-tumor nutrient heterogeneity, dynamic cell migration due to nutrient gradients, and stromal cells. This extended model was tested on 10 head and neck cancer patients treated with chemoradiotherapy, randomly drawn from a larger MSKCC protocol involving baseline and mid-therapy dynamic PET scans. For each voxel, initial fractions of proliferative and hypoxic tumor cells were obtained by finding an approximate solution to a system of linear equations relating cell fractions to voxel-level FDG uptake, perfusion (FMISO K{sub 1}) and hypoxia (FMISO k{sub 3}). The TCP model then predicted their evolution over time up until the mid treatment scan. Finally, the linear model was reapplied to predict each lesion’s median hypoxia level (k{sub 3}[med,sim]) which in turn was compared to the FMISO k{sub 3}[med] measured at mid-therapy. Results: The average k3[med] of the tumors in pre-treatment scans was 0.0035 min{sup −1}, with an inter-tumor standard deviation of σ[pre]=0.0034 min{sup −1}. The initial simulated k{sub 3}[med,sim] of each tumor agreed with the corresponding measurements within 0.1σ[pre]. In 7 out of 10 lesions, the mid-treatment k{sub 3}[med,sim] prediction agreed with the data within 0.3σ[pre]. The remaining cases corresponded to the most extreme relative changes in k{sub 3}[med]. Conclusion: This work presents a method to personalize the prediction of a TCP model using pre-treatment kinetic imaging data, and validates the modeling of radiotherapy response by predicting changes in median hypoxia values during treatment. Variations from predicted response may be a useful biomarker, which should be further explored. Partially supported by NIH grant #1 R01 CA157770-01A1 and a grant from Varian Corporation.

60 APPLIED LIFE SCIENCES↗

Dose Escalation for Locally Advanced Lung Cancer Using Adaptive Radiation Therapy With Simultaneous Integrated Volume-Adapted Boost

Purpose: To test the feasibility of a planned phase 1 study of image-guided adaptive radiation therapy in locally advanced lung cancer. Methods and Materials: Weekly 4-dimensional fan beam computed tomographs (4D FBCT) of 10 lung cancer patients undergoing concurrent chemoradiation therapy were used to simulate adaptive radiation therapy: After an initial intensity modulated radiation therapy plan (0-30 Gy/2 Gy), adaptive replanning was performed on week 2 (30-50 Gy/2 Gy) and week 4 scans (50-66 Gy/2 Gy) to adjust for volume and shape changes of primary tumors and lymph nodes. Week 2 and 4 clinical target volumes (CTV) were deformably warped from the initial planning scan to adjust for anatomical changes. On the week 4 scan, a simultaneous integrated volume-adapted boost was created to the shrunken primary tumor with dose increases in 5 0.4-Gy steps from 66 Gy to 82 Gy in 2 scenarios: plan A, lung isotoxicity; plan B, normal tissue tolerance. Cumulative dose was assessed by deformably mapping and accumulating biologically equivalent dose normalized to 2 Gy-fractions (EQD2). Results: The 82-Gy level was achieved in 1 in 10 patients in scenario A, resulting in a 13.4-Gy EQD2 increase and a 22.1% increase in tumor control probability (TCP) compared to the 66-Gy plan. In scenario B, 2 patients reached the 82-Gy level with a 13.9 Gy EQD2 and 23.4% TCP increase. Conclusions: The tested image-guided adaptive radiation therapy strategy enabled relevant increases in EQD2 and TCP. Normal tissue was often dose limiting, indicating a need to modify the present study design before clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Head-and-Neck Cancer: Potential to Improve Tumor Control and Late Toxicity

Purpose: To evaluate the potential benefit of 4π radiation therapy in recurrent, locally advanced, or metastatic head-and-neck cancer treated with stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty-seven patients with 29 tumors who were treated using SBRT were included. In recurrent disease (n=26), SBRT was delivered with a median 44 Gy (range, 35-44 Gy) in 5 fractions. Three patients with sinonasal mucosal melanoma, metastatic breast cancer, and primary undifferentiated carcinoma received 35 Gy, 22.5 Gy, and 40 Gy in 5 fractions, respectively. Novel 4π treatment plans were created for each patient to meet the objective that 95% of the planning target volume was covered by 100% of the prescription dose. Doses to organs at risk (OARs) and 50% dose spillage volumes were compared against the delivered clinical SBRT plans. Local control (LC), late toxicity, tumor control probability (TCP), and normal tissue complication probability were determined. Results: Using 4π plans, mean/maximum doses to all OARs were reduced by 22% to 89%/10% to 86%. With 4π plans, the 50% dose spillage volume was decreased by 33%. Planning target volume prescription dose escalation by 10 Gy and 20 Gy were achieved while keeping doses to OARs significantly improved or unchanged from clinical plans, except for the carotid artery maximum dose at 20-Gy escalation. At a median follow-up of 10 months (range, 1-41 months), crude LC was 52%. The 2-year LC of 39.2% approximated the predicted mean TCP of 42.2%, which increased to 45.9% with 4π plans. For 10-Gy and 20-Gy dose escalation, 4π plans increased TCP from 80.1% and 88.1% to 85.5% and 91.4%, respectively. The 7.4% rate of grade ≥3 late toxicity was comparable to the predicted 5.6% mean normal tissue complication probability for OARs, which was significantly reduced by 4π planning at the prescribed and escalated doses. Conclusions: 4π plans may allow dose escalation with significant and consistent improvements in critical organ sparing, tumor control, and coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Radiobiological Gamma Index for Evaluation of 3-Dimensional Predicted Dose Distribution

Purpose: To propose a gamma index-based dose evaluation index that integrates the radiobiological parameters of tumor control (TCP) and normal tissue complication probabilities (NTCP). Methods and Materials: Fifteen prostate and head and neck (H&N) cancer patients received intensity modulated radiation therapy. Before treatment, patient-specific quality assurance was conducted via beam-by-beam analysis, and beam-specific dose error distributions were generated. The predicted 3-dimensional (3D) dose distribution was calculated by back-projection of relative dose error distribution per beam. A 3D gamma analysis of different organs (prostate: clinical [CTV] and planned target volumes [PTV], rectum, bladder, femoral heads; H&N: gross tumor volume [GTV], CTV, spinal cord, brain stem, both parotids) was performed using predicted and planned dose distributions under 2%/2 mm tolerance and physical gamma passing rate was calculated. TCP and NTCP values were calculated for voxels with physical gamma indices (PGI) >1. We propose a new radiobiological gamma index (RGI) to quantify the radiobiological effects of TCP and NTCP and calculate radiobiological gamma passing rates. Results: The mean RGI gamma passing rates for prostate cases were significantly different compared with those of PGI (P<.03–.001). The mean RGI gamma passing rates for H&N cases (except for GTV) were significantly different compared with those of PGI (P<.001). Differences in gamma passing rates between PGI and RGI were due to dose differences between the planned and predicted dose distributions. Radiobiological gamma distribution was visualized to identify areas where the dose was radiobiologically important. Conclusions: RGI was proposed to integrate radiobiological effects into PGI. This index would assist physicians and medical physicists not only in physical evaluations of treatment delivery accuracy, but also in clinical evaluations of predicted dose distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-Fluorodeoxyglucose/Positron Emission Tomography Predicts Patterns of Failure After Definitive Chemoradiation Therapy for Locally Advanced Non-Small Cell Lung Cancer

Background: We previously reported that pretreatment positron emission tomography (PET) identifies lesions at high risk for progression after concurrent chemoradiation therapy (CRT) for locally advanced non-small cell lung cancer (NSCLC). Here we validate those findings and generate tumor control probability (TCP) models. Methods: We identified patients treated with definitive, concurrent CRT for locally advanced NSCLC who underwent staging {sup 18}F-fluorodeoxyglucose/PET/computed tomography. Visible hypermetabolic lesions (primary tumors and lymph nodes) were delineated on each patient's pretreatment PET scan. Posttreatment imaging was reviewed to identify locations of disease progression. Competing risks analyses were performed to examine metabolic tumor volume (MTV) and radiation therapy dose as predictors of local disease progression. TCP modeling was performed to describe the likelihood of local disease control as a function of lesion size. Results: Eighty-nine patients with 259 hypermetabolic lesions (83 primary tumors and 176 regional lymph nodes) met the inclusion criteria. Twenty-eight patients were included in our previous report, and the remaining 61 constituted our validation cohort. The median follow-up time was 22.7 months for living patients. In 20 patients, the first site of progression was a primary tumor or lymph node treated with radiation therapy. The median time to progression for those patients was 11.5 months. Data from our validation cohort confirmed that lesion MTV predicts local progression, with a 30-month cumulative incidence rate of 23% for lesions above 25 cc compared with 4% for lesions below 25 cc (P=.008). We found no evidence that radiation therapy dose was associated with local progression risk. TCP modeling yielded predicted 30-month local control rates of 98% for a 1-cc lesion, 94% for a 10-cc lesion, and 74% for a 50-cc lesion. Conclusion: Pretreatment FDG-PET identifies lesions at risk for progression after CRT for locally advanced NSCLC. Strategies to improve local control should be tested on high-risk lesions, and treatment deintensification for low-risk lesions should be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In situ synthesis of magnesium-substituted biphasic calcium phosphate and in vitro biodegradation

Highlights: ► Mg–BCP were successfully prepared through in situ aqueous co-precipitation method. ► The amount of β-TCP phase was changed with the magnesium substitution level. ► The substitution of magnesium led to a decrease in the unit cell volume. ► Mg–BCP could be able to develop a new apatite phase on the surface faster than BCP. -- Abstract: In situ preparation of magnesium (Mg) substituted biphasic calcium phosphate (BCP) of hydroxyapatite (HAp)/β-tricalcium phosphate (β-TCP) were carried out through aqueous co-precipitation method. The concentrations of added magnesium were varied with the calcium in order to obtain constant (Ca + Mg)/P ratios of 1.602. X-ray diffraction (XRD) and Fourier transformed infrared (FTIR) spectroscopy were used to characterize the structure of synthesized magnesium substituted BCP powders. The results have shown that substitution of magnesium in the calcium deficient apatites revealed the formation of biphasic mixtures of different HAp/β-TCP ratios after heating at 1000 °C. The ratios of the formation of phase mixtures were dependent on the content of magnesium. After immersing in Hanks’ balanced salt solution (HBSS) for 1 week, 1 wt% magnesium substituted BCP powders were degraded and precipitation started to be formed with small granules consisting of number of flake-like crystal onto the surface of synthesized powders. On the other hand, in the case of pure BCP powders, the formation of new precipitates was detected after immersion in HBSS for 2 weeks. On the basis of these results, magnesium substituted BCP could be able to develop a new apatite phase on the surface in contact with physiological fluids faster than BCP does. In addition, the retention time to produce the new apatite phase in implantation operation for the BCP powder could be controlled by the amount of magnesium substitution.

36 MATERIALS SCIENCE↗

Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer

Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTV{sub setup} were compared according to target coverage and dose. The PTV{sub setup} was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5 Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗