At least 145 records · Page 8

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank

This paper presents a multi-node finite volume model of the chilling and filling of a cryogenic tank using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. Vented Chill and No Vent Fill (VCNVF) tests were conducted at Marshall Space Flight Center where a flight-like tank was filled with liquid nitrogen from a supply tank. In the VCNVF tests, the tank was partially chilled while the vent valve was open. After the partial chilling, the vent valve was closed and the tank was filled without any venting. An integrated numerical model of the test set up was developed. The model included the transfer line from the supply tank, the target tank with the spray nozzle and solid walls, and the discharge line with the vent valve. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor in the tank when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall and ullage temperature in the tank were compared with the test data.

Alok Majumdar↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Deployment of Low Temperature Aluminum Dissolution (LTAD) Technology to Retrieve H-Modified (HM) Sludge in SRS Tank 15 – 25672

Tank 15 is a 4,234,000-liter (1,118,500-gallon) Type 2 high-level waste storage tank located in H Tank Farm at the Savannah River Site. It was put into service in 1960 to receive high-activity, H-Modified (HM) waste from H Canyon. Between June 1964 and November 1972, the waste tank was filled six times, and supernate was decanted five times, leaving behind the sludge solids. Tank 15 also received a mixture of high-activity and low-activity HM waste from Tank 16. Tank 15 has more recently undergone several mixing campaigns to remove much of the sludge waste; however, the effectiveness of suspending the sludge heel via mechanical mixing has significantly diminished. Low Temperature Aluminum Dissolution (LTAD) is a process developed for the dissolution of suspended aluminum solids in a large waste storage tank. Originally intended for deployment during the preparation of sludge batches in H Tank Farm for the Defense Waste Processing Facility (DWPF), the process involves maintaining the waste storage tank at a slightly elevated temperature and highly alkaline chemistry to facilitate dissolution of aluminum solids. As mechanical heel removal efforts diminished in effectiveness in Tank 15, LTAD was selected to both reduce the volume of sludge solids remaining in the heel and to modify the sludge rheology to facilitate the suspension of additional solids using the installed mixing devices.

Campbell, Seth G.↗

Review of analytical studies on seismic fluid-structure interaction of base-supported cylindrical tanks

Analytical solutions for seismic fluid-structure interaction (FSI) of tanks are used by analysts and engineers for a number of purposes, including preliminary sizing, risk assessment, and verification of numerical models. Analytical solutions for seismic FSI of tanks were first developed in the 1930s and have been extended and/or modified in the following nine decades to accommodate different seismic inputs and boundary conditions. This report reviews published analytical solutions for rigid and flexible, base-supported, cylindrical tanks subjected to unidirectional horizontal motion of a small amplitude. The studies parsed the fluid-structure (FSI) response into an impulsive and a convective component, and addressed frequencies of lateral motions of the tank (i.e., impulsive frequencies), hydrodynamic pressures, frequencies of waves (i.e., convective frequencies), wave heights, and reactions at the base. The solutions were categorized into exact and approximate solutions based on the methodologies used. Herein, FSI responses are calculated and compared for a range of tank dimensions using the analytical solutions from the different studies. The responses presented here are normalized to be unitless, and can be used for tanks with different dimensions and mechanical properties, and subjected to different input motions. A sample steel water tank is analyzed using the normalized solutions for two earthquake ground motions with different frequency contents. Ignoring tank flexibility may significantly underestimate seismic responses of the tank and its contained fluid. The approximate solutions, which have been widely used for decades, may not be sufficiently accurate in the modern era. Calculation errors in the reviewed studies are identified and corrected, and differences are quantified for the sample tank.

42 ENGINEERING↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

The purpose of the pressurization system in liquid rocket propulsion is to control the pressure in the gas space of the propellant tank (known as the ullage space) and the propellant mass flowrate to the engine. A mathematical model is required to predict the amount of pressurant necessary to ensure that pressure and temperature levels inside the tank remain within acceptable limits and that the propellant pressure leaving the tank satisfies the net positive suction pressure (NPSP) requirement of the pump feeding the engine. Nodal codes typically model tank pressurization and draining using a single node to represent the ullage and a single node to represent the propellant. As the tank drains, the ullage node grows and the propellant node shrinks. The heat transfer between ullage to wall and ullage to propellant is governed by natural convection. Designers of liquid propulsion systems often use empirical correlations to estimate the “Collapse Factor” which represents the ratio of pressurant required with heat transfer and the amount of pressurant required without heat transfer. A single node ullage model of tank pressurization was developed using GFSSP to compute the collapse factor reasonably well and later was used to model tank pressurization during test firing of the FASTRAC rocket engine. The predicted tank pressure compared well with the test data. In the early 1970’s, pressurization and drain tests with liquid methane were performed at NASA Lewis Research Center in a vacuum chamber. A 5 ft diameter spherical aluminum tank was tested to drain from 95% to 5% full using gaseous helium, hydrogen, nitrogen and methane as pressurant. Tests were conducted with different pressurant inlet temperatures and drain times. Measured data include pressurant requirement, amount of pressurant condensed, and ullage and wall temperatures at various heights in the ullage space at the end of draining. A single node GFSSP model was developed to simulate helium pressurization of the methane tank. Predicted helium consumption was 8-23% less than measured. The average error of the six test cases was 16%. A single ullage node with multiple solid node model was developed using Thermal Desktop. Predicted helium consumption compares with the test data within 2%. This paper describes the development of a GFSSP multi-node ullage model of the test configuration and compares the predicted pressurant consumption for both helium and autogenous pressurization using gaseous methane with experimental as well as TD predictions.

Nodal Model↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 48H Tetraphenylborate Mitigation: Simulant Studies using Sodium Permanganate

Tank 48H currently holds legacy material containing organic tetraphenylborate (TPB) compounds from the operation of the In-Tank Precipitation (ITP) process. TPB was added during the ITP process to precipitate the otherwise soluble cesium as insoluble cesium TPB (CsTPB), but excessive benzene generation from TPB degradation curtailed this treatment method. The contents of Tank 48H, which include approximately 26.000 kg of potassium TPB (KTPB) and trace CsTPB, are not compatible with the waste treatment facilities at the Savannah River Site (SRS) since the organic content and the associated flammability issues pose a challenge to the salt processing and sludge processing facilities within the liquid waste system. An in-tank process to remove (or decompose) TPB safely would be of great value. Previous testing at Savannah River National Laboratory (SRNL) demonstrated the destruction of glycolate via chemical oxidation using sodium permanganate with simulated and radioactive waste. Scoping tests were performed to study the destruction of TPB to determine if the contents of Tank 48H would be amenable to the same type of destruction. Partial destruction of TPB was observed in Tank 48H simulants under mild conditions (e g., pH 11, room temperature) with no definitive indication of benzene generation. To build upon the success of the scoping tests, an additional study was requested to provide a better understanding of the underlying chemistry for Tank 48H content destruction using sodium permanganate. Three experiments were performed with Tank 48H simulants at 40 °C to determine the efficacy of using sodium permanganate for TPB destruction. Three starting pH values were selected: 1) pH 11 for comparison with the previous work at room temperature, 2) pH 10 as the minimum pH recommended by the Corrosion Control Program (CCP) for in-tank processing, and 3) pH 8 to determine the effectiveness of TPB destruction at near neutral pH. While below the allowable pH for the CCP, the experiment at pH 8 was performed to study the TPB-Permanganate reaction under more extreme conditions and further verify the potential for out-of-tank processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge Batch 11 Assembly: Tank 51

Savannah River Mission Completion (SRMC) Nuclear Safety and Engineering Integration has requested that Savannah River National Laboratory (SRNL) perform Tank 51 characterization analyses in support of Sludge Batch 11 (SB11) assembly. This report provides important characterization of the slurry in Tank 51 after transfers from Tank 22, Tank 35, and Tank 13 (post Tank 15 to Tank 13 transfer) to Tank 51 that demonstrates the sludge concurs with the estimated transfer mass for the SB11 recipe. A total of 3 sets of Tank 51 samples were delivered to SRNL from March 2023 to February 2024. The composite sample was analyzed for the following: density, weight percent solids, chemical composition, radionuclides, and supernate corrosion control analyses. The results of the Tank 51 samples are consistent with and representative of expected sludge projections for Sludge Batch 11.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design considerations for honeycomb double-bubble tanks utilized in aerospace vehicles

Future earth-to-orbit vehicles will utilize reusable internal fuel tanks requiring most of the vehicle volume. Because weight reduction and volumetric efficiency are essential, these tanks will be integral to the vehicle structure, and the vehicle cross section will dictate the size and shape of the tank. For a fuselage with a noncircular cross section, a multibubble tank configuration may be employed. Multibubble tanks offer a reduction in tank weight over a single-lobe tank or several cylindrical tanks in a noncircular cross section but sacrifice the efficiency of utilizing the entire fuselage cross section. This paper includes a general configuration analysis of a double-bubble tank, a materials and efficiency study, and a complete mission design analysis centers on sizing the tank to withstand ascent and reentry loads while minimizing the structural weight.

Lentz, Christopher A.↗

Experimental Investigation of Jet-Induced Mixing of a Large Liquid Hydrogen Storage Tank

Experiments have been conducted to investigate the effect of fluid mixing on the depressurization of a large liquid hydrogen storage tank. The test tank is approximately ellipsoidal, having a volume of 4.89 m(exp 3) and an average wall heat flux of 4.2 W/m(exp 2) due to external heat input. A mixer unit was installed near the bottom of the tank to generate an upward directed axial jet flow normal to the liquid-vapor interface. Mixing tests were initiated after achieving thermally stratified conditions in the tank either by the introduction of hydrogen gas into the tank or by self-pressurization due to ambient heat leak through the tank wall. The subcooled liquid jet directed towards the liquid-vapor interface by the mixer induced vapor condensation and caused a reduction in tank pressure. Tests were conducted at two jet submergence depths for jet Reynolds numbers from 80,000 to 495,000 and Richardson numbers from 0.014 to 0.52. Results show that the rate of tank pressure change is controlled by the competing effects of subcooled jet flow and the free convection boundary layer flow due to external tank wall heating. It is shown that existing correlations for mixing time and vapor condensation rate based on small scale tanks may not be applicable to large scale liquid hydrogen systems.

Lin, C. S.↗

Water Tank with Capillary Air/Liquid Separation

A bladderless water tank (see figure) has been developed that contains capillary devices that allow it to be filled and emptied, as needed, in microgravity. When filled with water, the tank shields human occupants of a spacecraft against cosmic radiation. A membrane that is permeable by air but is hydrophobic (neither wettable nor permeable by liquid water) covers one inside surface of the tank. Grooves between the surface and the membrane allow air to flow through vent holes in the surface as the tank is filled or drained. A margin of wettable surface surrounds the edges of the membrane, and all the other inside tank surfaces are also wettable. A fill/drain port is located in one corner of the tank and is covered with a hydrophilic membrane. As filling begins, water runs from the hydrophilic membrane into the corner fillets of the tank walls. Continued filling in the absence of gravity will result in a single contiguous air bubble that will be vented through the hydrophobic membrane. The bubble will be reduced in size until it becomes spherical and smaller than the tank thickness. Draining the tank reverses the process. Air is introduced through the hydrophobic membrane, and liquid continuity is maintained with the fill/drain port through the corner fillets. Even after the tank is emptied, as long as the suction pressure on the hydrophilic membrane does not exceed its bubble point, no air will be drawn into the liquid line.

Ungar, Eugene K.↗

Multifunctional Tanks for Spacecraft

A document discusses multifunctional tanks as means to integrate additional structural and functional efficiencies into designs of spacecraft. Whereas spacecraft tanks are traditionally designed primarily to store fluids and only secondarily to provide other benefits, multifunctional tanks are designed to simultaneously provide multiple primary benefits. In addition to one or more chamber(s) for storage of fluids, a multifunctional tank could provide any or all of the following: a) Passageways for transferring the fluids; b) Part or all of the primary structure of a spacecraft; c) All or part of an enclosure; d) Mechanical interfaces to components, subsystems, and/or systems; e) Paths and surfaces for transferring heat; f)Shielding against space radiation; j) Shielding against electromagnetic interference; h) Electrically conductive paths and surfaces; and i) Shades and baffles to protect against sunlight and/or other undesired light. Many different multifunctional-tank designs are conceivable. The design of a particular tank can be tailored to the requirements for the spacecraft in which the tank is to be installed. For example, the walls of the tank can be flat or curved or have more complicated shapes, and the tank can include an internal structure for strengthening the tank and/or other uses.

Collins, David H.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

External Tank Program - Legacy of Success

The largest single element of Space Shuttle is the External Tank (ET), which serves as the structural backbone of the vehicle during ascent and provides liquid propellants to the Orbiter s three Main Engines. The ET absorbs most of the seven million pounds of thrust exerted by the Solid Rocket Boosters and Main Engines. The design evolved through several block changes, reducing weight each time. Because the tank flies to orbital velocity with the Space Shuttle Orbiter, minimization of weight is mandatory, to maximize payload performance. The initial configuration, the standard weight tank, weighed 76,000 pounds and was an aluminum 2219 structure. The light weight tank weighed 66,000 pounds and flew 86 missions. The super light weight tank weighed 58,500 pounds and was primarily an aluminum-lithium structure. The final configuration and low weight enabled system level performance sufficient for assembly of the International Space Station in a high inclination orbit, vital for international cooperation. Another significant challenge was the minimization of ice formation on the cryogenic tanks. This was essential due to the system configuration and the choice of ceramic thermal protection system materials on the Orbiter. Ice would have been a major debris hazard. Spray on foam insulation materials served multiple functions including thermal insulation, conditioning of cryogenic propellants, and thermal protection for the tank structure during ascent and entry. The tank is large, and unique manufacturing facilities, tooling, and handling, and transportation operations were developed. Weld processes and tooling evolved with the design as it matured through several block changes. Non Destructive Evaluation methods were used to assure integrity of welds and thermal protection system materials. The aluminum-lithium alloy was used near the end of the program and weld processes and weld repair techniques had to be refined. Development and implementation of friction stir welding was a substantial technology development incorporated during the Program. Automated thermal protection system application processes were developed for the majority of the tank surface. Material obsolescence was an issue throughout the multi-decade program. Process controls were implemented to assure cleanliness in the production environment, to control contaminants, and to preclude corrosion. Each tank was accepted via rigorous inspections, including non-destructive evaluation techniques, proof testing, and all systems testing. In the post STS-107 era, the project focused on ascent debris risk reduction. This was accomplished via stringent process controls, post flight assessment using substantially improved imagery, and selective redesigns. These efforts were supported with a number of test programs to simulate combined environments. The debris risk was reduced by two orders of magnitude. During this time a major natural disaster was overcome when hurricane Katrina damaged the manufacturing facility. Numerous lessons from these efforts, the manufacturing and material processing issues, the key design features, and evolution of the design will be discussed.

Pilet, Jeffery C.↗

Sloshing in Liquid Hydrogen and LOX Propellant Tanks After Main Engine Cut-off

NASA Marshall Space Flight Center is designing and developing the Main Propulsion System (MPS) for Ares launch vehicles. The objective of this study is to calculate the sloshing forces and moments in the LH2 and LO2 propellant tanks using a CFD/VOF analysis under realistic flight conditions. Propellant sloshing in the liquid hydrogen (LH2) and the liquid oxygen (LO2) propellant tanks after Main Engine Cut Off (MECO) was modeled using the Volume of Fluid (VOF) module of the computational fluid dynamics code, CFD-ACE+. The present simulation shows that there are substantial sloshing side forces acting on the LH2 tank during the deceleration of the vehicle after MECO. The LH2 tank features a side wall drain pipe. The side loads result from the residual propellant mass motion in the LH2 tank which is initiated by the stop of flow into the drain pipe at MECO. The simulations show that radial force on the LH2 tank wall is less than 50 lbf and the radial moment calculated based up the center of gravity of the vehicle is predicted to be as high as 300 lbf-ft. The LO2 tank features a bottom dome drain system and is equipped with sloshing baffles. The remaining LO2 in the tank slowly forms a liquid column along the centerline of tank under the zero gravity environments. The radial force on the LO2 tank wall is predicted less than 100 lbf. The radial moment calculated based on the center of gravity of the vehicle is predicted as high as 4500 lbf-ft just before MECO and dropped down to near zero after propellant draining stopped completely.

Kim, Sura↗