Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Subcooled Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental Investigation of Flow Orientation Effects on Cryogenic Flow Boiling

Cryogenic flow boiling physics is of paramount importance for future cryogenic space applications employing Cryogenic Fluid Management (CFM) technologies. This experimental study investigates the two-phase flow and heat transfer performance of LN 2 flow boiling across five distinct flow orientations: vertical upflow, vertical downflow, horizontal flow, 45° inclined upflow, and 45° inclined downflow. The study employed the steady- state heating method within a circular heated tube featuring an 8.5-mm inner diameter and a 680-mm heated length. High-speed video recordings were utilized to capture two-phase flow patterns and interfacial behaviors across various flow orientations. The experiments covered a wide range of operating conditions, including mass velocities ranging from 351.80 to 1572.77 kg/m 2 s and inlet pressures from 297.14 to 1032.97 kPa, primarily with near-saturated inlet subcooling. Distinct two-phase flow patterns and regime transitions were identified for each flow orientation. Symmetrical flow patterns were evident in vertical orientations, whereas non-vertical orientations exhibited asymmetric flow stratifications, primarily influenced by the buoyancy force in a terrestrial gravity environment. Bubble dynamic parameters were quantified, and bubble collision and dispersion phenomena were visualized. Analyzing heat transfer performance based on local flow boiling curves and variations in heat transfer coefficients (HTCs), it was observed that vertical upflow demonstrated the most enhanced heat transfer performance, while vertical downflow exhibited the lowest. As mass velocity exceeded 830 kg/ m 2 s, the differences in heat transfer among orientations became less distinct, emphasizing the role of flow inertia in mitigating the influence of flow orientation. A direct comparison of microgravity HTC data from a recent study by the authors against the 1-𝘨 e HTC data indicated enhanced heat transfer performance in microgravity for flow orientation configurations in terrestrial gravity. However, this enhancement progressively diminished as the heat flux increased. Distinct HTC trends were observed as mass velocity increased for different flow orientations and gravity levels.

Cryogens↗

Rewet Temperature Correlations for Liquid-Nitrogen Boiling Pipe Flows Across Varying Flow Conditions and Orientations

In many convective liquid-vapor phase change heat transfer engineering applications, cryogenic fluids are widely used in industrial processes, spacecraft and cryosurgery systems, and so on. For example, cryogens are usually used as liquid fuels such as liquid hydrogen and oxygen in the rocket industry, liquid nitrogen (LN2) and helium are frequently used to cool superconducting magnetic device for medical applications. In these systems, proper transport, handling, and storage of cryogenic fluids are of extreme importance. Among all the cryogenic transport processes performed in room temperatures, quenching, also termed chilldown, is a unavoidable initial, transient phase-change heat transfer process that brings the system down to the cryogenic condition. The Leidenfrost temperature or rewet temperature that signals the end of film boiling is practically considered the completion point of a quenching process. Therefore, rewet temperature has been considered the most important parameter for the engineering design of cryogenic thermal management systems. As most of the previous correlations for predicting the Leidenfrost temperature and the rewet temperature have been basically developed for water, they are shown to disagree with recent liquid nitrogen pipe chilldown experiments in upward and downward flow directions over a wide range of flow rates, pressures, and degrees of inlet subcooling. In addition to a complete review of the literature, two new correlations are presented in this work, one based on bubble growth and another based on the theoretical maximum limit of superheat. Each correlation performs well over the entire data set.

liquid nitrogen↗

Experimental and Computational Investigation of Flow Boiling in Microgravity

This study explores use of Computational Fluid Dynamics (CFD) to predict near-saturated flow boiling of FC-72 in microgravity. The computational method employs transient analysis to predict detailed interfacial behavior and heat transfer characteristics along a rectangular channel heated along two opposite walls. Predicted results are validated against experimental temperature measurements and high-speed video images captured during a series of parabolic aircraft maneuvers for three sets of operating conditions which include variations of both mass velocity and wall heat flux. The computational method is based on the multi-phase volume of fluid (VOF) model, which is combined with appropriate phase change and turbulence models, and accounts for both shear-lift force on bubbles and conjugate heat transfer along the heating walls. A key advantage of the CFD method is ability to capture details that are very difficult to measure experimentally, including detailed spatial variations of bubble shape, void fraction, mixture fluid temperature, liquid velocity, and vapor velocity, results for which are presented for each of the three test cases. Different flow regimes predicted along the heated length exhibit a number of dominant mechanisms including bubble nucleation, bubble growth, coalescence, vapor blankets, interfacial waviness, and residual liquid sub-layer, all of which agree well with experiment. Vapor velocity is shown to increase appreciably along the heated length because of increased void fraction, while liquid velocity experiences large fluctuations. Non-equilibrium effects are accentuated with increasing mass velocity, contributing minor deviations of fluid temperature from simulations compared to those predicted by the analytical method. Predicted wall temperature is fairly uniform in the middle of the heated length but increases in the entrance region, due to sensible heat transfer in the subcooled liquid, and decreases toward the exit, mostly because of flow acceleration resulting from increased void fraction.

two-phase cooling; flow boiling; CFD; microgravity↗

Gas-Liquid Flows and Phase Separation

Common issues for space system designers include:Ability to Verify Performance in Normal Gravity prior to Deployment; System Stability; Phase Accumulation & Shedding; Phase Separation; Flow Distribution through Tees & Manifolds Boiling Crisis; Heat Transfer Coefficient; and Pressure Drop.The report concludes:Guidance similar to "A design that operates in a single phase is less complex than a design that has two-phase flow" is not always true considering the amount of effort spent on pressurizing, subcooling and phase separators to ensure single phase operation. While there is still much to learn about two-phase flow in reduced gravity, we have a good start. Focus now needs to be directed more towards system level problems .

McQuillen, John↗

Marangoni Effects on Near-Bubble Microscale Transport During Boiling of Binary Fluid Mixtures

In earlier investigations, Marangoni effects were observed to be the dominant mechanism of boiling transport in 2-propanol/water mixtures under reduced gravity conditions. In this investigation we have examined the mechanisms of binary mixture boiling by exploring the transport near a single bubble generated in a binary mixture between a heated surface and cold surface. The temperature field created in the liquid around the bubble produces vaporization over the portion of its interface near the heated surface and condensation over portions of its interface near the cold surface. Experiments were conducted using different mixtures of water and 2-propanol under 1g conditions and under reduced gravity conditions aboard the KC135 aircraft. Since 2-propanol is more volatile than water, there is a lower concentration of 2-propanol near the hot surface and a higher concentration of 2-propanol near the cold plate relative to the bulk quantity. This difference in interface concentration gives rise to strong Marangoni effects that move liquid toward the hot plate in the near bubble region for 2-propanol and water mixtures. In the experiments in this study, the pressure of the test system was maintained at about 5 kPa to achieve the full spectrum of boiling behavior (nucleate boiling, critical heat flux and film boiling) at low temperature and heat flux levels. Heat transfer data and visual documentation of the bubble shape were extracted from the experimental results. In the 1-g experiments at moderate to high heat flux levels, the bubble was observed to grow into a mushroom shape with a larger top portion near the cold plate due to the buoyancy effect. The shape of the bubble was somewhat affected by the cold plate subcooling and the superheat of the heated surface. At low superheat levels for the heated surface, several active nucleation sites were observed, and the vapor stems from them merged to form a larger bubble. The generation rate of vapor is moderate in this regime and the bubble shape is cylindrical in appearance. In some instances, the bubble interface appeared to oscillate. At higher applied heat flux levels, the top of the bubble became larger, apparently to provide more condensing interface area adjacent to the cold plate. Increasing the applied heat flux ultimately led to dry-out of the heated surface, with conditions just prior to dryout corresponding to the maximum heat flux (CHF). A more stable bubble was observed when the system attained the minimum heat flux (for film boiling). In this regime, most of the surface under the bottom of the bubble was dry with nucleate boiling sometimes occuring around the contact perimeter of the bubble at heated surface. Different variations (e.g. gap between two plates, molar concentration of the liquid mixture) of the experiments were examined to determine parametric effects on the boiling process and to determine the best conditions for the KC135 reduced gravity tests. Variation of the gap was found to have a minor impact on the CHF. However, reducing the gap between the hot and cold surface was observed to significantly reduce the minimum heat flux for fixed molar concentration of 2-propanol. In the reduced gravity experiments aboard the KC135 aircraft, the bubble formed in the 6.4 mm gap was generally cylindrical or barrel shaped and it increased its extent laterally as the surface superheat increased. In reduced gravity experiments, dryout of the heated surface under the bubble was observed to occur at a lower superheated temperature than for 1g conditions. Observed features of the boiling process and heat transfer data under reduced gravity will be discussed in detail. The results of the reduced gravity experiments will also be compared to those obtained in comparable 1g experiments. In tandem with the experiments we are also developing a computational model of the transport in the liquid surrounding the bubble during the boiling process. The computational model uses a level set method to model motion of the interface. It will incorporate a macroscale treatment of the transport in the liquid gap between the surfaces and a microscale treatment of transport in the regions between the bubble interface and the solid surfaces. The features of the model will be described in detail. Future research directions suggested by the results to date will also be discussed.

V. Carey↗

Transition from Pool to Flow Boiling: The Effect of Reduced Gravity

Applications of boiling heat transfer in space can be found in the areas of thermal management, fluid handling and control, power systems, on-orbit storage and supply systems for cryogenic propellants and life support fluids, and for cooling of electronic packages for power systems associated with various instrumentation and control systems. Recent interest in exploration of Mars and other planets, and the concepts of in-situ resource utiliLation on Mars highlights the need to understand the effect of gravity on boiling heat transfer at gravity levels varying from 1>= g/g(sub e) >=10(exp -6). The objective of the proposed work was to develop a mechanistic understanding of nucleate boiling and critical heat flux under low and micro-gravity conditions when the velocity of the imposed flow is small. For pool boiling, the effect of reduced gravity is to stretch both the length scale as well as the time scale for the boiling process. At high flow velocities, the inertia of the liquid determines the time and the length scales and as such the gravitational acceleration plays little role. However, at low velocities and at low gravity levels both liquid inertia and buoyancy are of equal importance. At present, we have little understanding of the interacting roles of gravity and liquid inertia on the nucleate boiling process. Little data that has been reported in the literature does not have much practical value in that it can not serve as a basis for design of heat exchange components to be used in space. Both experimental and complete numerical simulations of the low velocity, low-gravity nucleate boiling process were carried out. A building block type of approach was used in that first the growth and detachment process of a single bubble and flow and heat transfer associated with the sliding motion of the bubble over the heater surface after detachment was studied. Liquid subcooling and flow velocity were varied parametrically. The experiments were conducted at 1 g(sub e), while varying the orientation of surface with respect to the gravity vector. In the laboratory experiments, holographic interferometry was used to obtain data on velocity and temperature fields associated with a bubble prior to, and after detachment and during sliding motion. A test rig for conducting experiments in the KC-135 was developed, but experiments could not be conducted due to the unavailability of the aircraft prior to completion of the project. Numerical simulations modeling the micro and macro regions of the bubble were carried out in three dimensions. The results of the experiments were used to validate analytical/numerical models.

Dhir, Vijay K.↗

A study of forced convection boiling under reduced gravity

This report presents the results of activities conducted over the period 1/2/85-12/31/90, in which the study of forced convection boiling under reduced gravity was initiated. The study seeks to improve the understanding of the basic processes that constitute forced convection boiling by removing the buoyancy effects which may mask other phenomena. Specific objectives may also be expressed in terms of the following questions: (1) what effects, if any, will the removal of body forces to the lowest possible levels have on the forced convection boiling heat transfer processes in well-defined and meaningful circumstances? (this includes those effects and processes associated with the nucleation or onset of boiling during the transient increase in heater surface temperature, as well as the heat transfer and vapor bubble behaviors with established or steady-state conditions); and (2) if such effects are present, what are the boundaries of the relevant parameters such as heat flux, heater surface superheat, fluid velocity, bulk subcooling, and geometric/orientation relationships within which such effects will be produced?

Merte, Herman, Jr.↗

Forced Convection Boiling and Critical Heat Flux of Ethanol in Electrically Heated Tube Tests

Electrically heated tube tests were conducted to characterize the critical heat flux (transition from nucleate to film boiling) of subcritical ethanol flowing at conditions relevant to the design of a regeneratively cooled rocket engine thrust chamber. The coolant was SDA-3C alcohol (95% ethyl alcohol, 5% isopropyl alcohol by weight), and tests were conducted over the following ranges of conditions: pressure from 144 to 703 psia, flow velocities from 9.7 to 77 ft/s, coolant subcooling from 33 to 362 F, and critical heat fluxes up to 8.7 BTU/in(exp 2)/sec. For the data taken near 200 psia, critical heat flux was correlated as a function of the product of velocity and fluid subcooling to within +/- 20%. For data taken at higher pressures, an additional pressure term is needed to correlate the critical heat flux. It was also shown that at the higher test pressures and/or flow rates, exceeding the critical heat flux did not result in wall burnout. This result may significantly increase the engine heat flux design envelope for higher pressure conditions.

Meyer, Michael L.↗

System design and analysis of thermal power dispatch systems for boiling water reactors

Nuclear power plants are crucial to meeting net zero emission goals and achieving energy sustainability. Integrating these plants with clean energy technologies such as high-temperature steam electrolysis (HTSE) may improve the efficiency and economic competitiveness of these plants. Here, the current study investigates the design and operation of a thermal power dispatch (TPD) system for coupling boiling water reactors (BWRs) to HTSE plants. The TPD system extracts a portion of the steam from the reactor’s main steam line and transfers its thermal energy to an HTSE plant through a power transport loop. A TPD system for 5 % steam extraction has been designed and the system performance during steady and transient operations has been analyzed. The TPD system dispatched a total of 197 MW thermal energy to the HTSE plant under nominal design conditions. Saturated steam at 7.17 MPa from the BWR plant was condensed and subcooled to a temperature of 168 °C, while a mass flow rate of 91.1 kg/s of superheated steam was dispatched to the HTSE plant. Furthermore, the system performance during transient operation showed a continuous transition from the initial hot standby mode to the nominal power dispatch level. The transient simulation results emphasized the importance of investigating component level performance for the TPD system design. The current results will guide future works on the development of integrated energy systems for hydrogen production or process heat applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Mechanistic Study of Nucleate Boiling Heat Transfer Under Microgravity Conditions

Experimental studies of growth and detachment processes of a single bubble and multiple bubbles formed on a heated surface have been conducted in the parabola flights of KC-135 aircraft. Distilled water and PF5060 were used as the test liquids. A micro-fabricated test surface was designed and built. Artificial cavities of diameters 10 microns, 7 microns and 4 microns were made on a thin polished Silicon wafer that was electrically heated by a number of small heating elements on the back side in order to control the surface superheat. Bubble growth period, bubble size and shape from nucleation to departure were measured under subcooled and saturation conditions. Significantly larger bubble departure diameters and bubble growth periods than those at earth normal gravity were observed. Bubble departure diameters as large as 20 mm for water and 6 mm for PF5060 were observed as opposed to about 3 mm for water and less than 1 mm for PF5060 at earth normal gravity respectively. It is found that the bubble departure diameter can be approximately related to the gravity level through the relation D(sub d) proportional 1/g(exp 1/2). For water,the effect of wall superheat and liquid subcooling on bubble departure diameter is found to be small.The growth periods are found to be very sensitive to liquid subcooling at a given wall superheat. However,the preliminary results of single bubble dynamics using PF5060 showed that the departure diameter increases when wall superheat is elevated at the same gravity and subcooling. Growth period of single bubbles in water has been found to vary as t(sub g) proportional g(exp -.93). For water, when the magnitude of horizontal gravitational components was comparable to that of gravity normal to the surface, single bubbles slid along the heater surface and departed with smaller diameter at the same gravity level in the direction normal to the surface. For PF5060, even a very small horizontal gravitational component caused the sliding of bubble along the surface. The numerical simulation has been carried out by solving under the condition of axisymmetry, the mass, momentum, and energy equations for the vapor and the liquid phases. In the model the contribution of micro-layer has been included and instantaneous shape of the evolving vapor-liquid interface is determined from the analysis. Consistent with the experimental results, it is found that effect of reduced gravity is to stretch the growth period and bubble diameter It is found that effect of reduced gravity is to stretch the growth period and bubble diameter at departure. The numerical simulations are in good agreement with the experimental data for both the departure diameters and the growth periods. In the study on dynamics of multiple bubbles, horizontal merger of 2,3 4,and 5 bubbles was observed. It is found that after merger of 2 and 3 bubbles the equivalent diameter of the detached bubble is smaller than that of a single bubble departing at the same gravity level. During and after bubble merger, liquid still fills the space between the vapor stems so as to form mushroom type bubbles. The experimental and numerical studies conducted so far have brought us a step closer to prediction of nucleate boiling heat fluxes under low gravity conditions. Preparations for a space flight are continuing.

Dhir, V. K.↗

Pool film boiling from rotating and stationary spheres in liquid nitrogen

Results are presented for a preliminary experiment involving a saturated pool boiling at 1 atm from rotating 2 and 3 inch diameter spheres which were immersed in LN2. Additional results are presented for a stationary 2 inch diameter sphere quenched in LN2, which were obtained with a more versatile and complete experimental apparatus. The speed of the rotational tests varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere.

Cuan, Winston M.↗

Investigations of Mechanisms Associated with Nucleate Boiling Under Microgravity Conditions

In this work a building block type of approach is used so that a basic understanding of the processes that contribute to nucleate boiling heat fluxes under microgravity conditions can be developed. This understanding will lead to development of a mechanistic model for nucleate boiling heat transfer which could eventually be used as a design tool in space applications. Task Description Task 1: Fabrication of the Experimental Setup. Under this task, the test section and liquid holding and viewing chambers will be fabricated. Artificial cylinder cavities will be formed on silicon wafers. A single cavity and two or four cavities, with a prescribed spacing and size, will be formed. The desired nucleation wall superheat will be used to determine the size of the mouth of the cavities. Task 2: Experiments. The basic experiments for flow and temperature field around single and multiple (2 or 4 separated or merged bubbles growing on downward facing or inclined surfaces) will be carried out under normal gravity conditions. The experiments will be conducted at one atmosphere pressure, but liquid subcooling will be varied from 0 to 30C. Water and PF-5050 will be used as test liquids. Task 3: Analytical/Numerical Models. In this task, transient temperature and flow field in vapor and liquid will be determined during growth of a single bubble. Analysis will include the evolution of the vapor-liquid interface and development of microlayer underneath the bubbles. For merged bubbles, detailed calculations of flow and temperature field will be carried out for transient shapes of vapor stems supporting a large bubble and the corresponding evaporation rate. Flow and temperature field for a bubble sliding along a heated wall will also be determined. Microgravity conditions will be simulated and a framework of a numerical tool for prediction of nucleate boiling heat fluxes under microgravity conditions will be developed. Task 4: Experiments in a KC-135. To understand bubble growth and detachment behavior of single or large merged bubbles, boiling experiments will be conducted under low gravity (10-2 g) conditions of the aircraft. In these experiments, 'designed' surfaces will be used. Visual observations and heat transfer data will be taken, but holography will not be used. The apparatus used for laboratory experiments will also be employed for experiments in the aircraft. Task 5: Experiments in the Space Shuttle. Effort will be devoted for defining a boiling experiment to be conducted on a 'designed' surface. The experiment will provide microgravity data on bubble growth and departure. These data are needed for development of a credible model for nucleate boiling heat fluxes under microgravity conditions. The heat transfer data will also be obtained and will be used to validate the models.

Dhir, Vijay K.↗

Cryogenic Propellant Tank Self-Pressurization and Active Pressure Control

This AIAA Short Course lecture will present an overview of different experiments and computational modeling work that has been done to examine different aspects of pressurization and pressure control of a Cryogenic propellant tank. The lecture will cover several large-scale ground-based liquid Hydrogen cryogenic self-pressurization experiments that were performed at NASA Glenn and NASA Marshall, LN2 Nitrogen autogenous pressurization experiments, pressure control experiments using both subcooled jet mixing and subcooled droplet injection, and experiments that examined pressure drops that occur during tank sloshing. Numerical modeling and simulations that were done in association to these experiments as part of a comprehensive model validation effort will also be presented and discussed. Finally, the results of two simulant fluid pressurization and pressure control microgravity investigations performed as part of the Tank Pressure Control Experiment (TCPE) and The Zero-Boil-Off Tank (ZBOT)Experiment will also be presented.

Propellant Management↗

Modeling of Vapor Bubble Growth Under Nucleate Boiling Conditions in Reduced Gravity

A dynamic model is developed to describe the evolution of a vapor bubble growing at a nucleation site on a superheated surface under arbitrary gravity. The bubble is separated from the surface by a thin microlayer and grows due to the evaporation from the microlayer interface. The average thickness of the microlayer increases as the bubble expands along the surface if the evaporation rate is lower than some critical value. The corresponding threshold value of the surface temperature has to be associated with the burn-out crisis. Two main reasons make for bubble separation, which are the buoyancy force and a force caused by the vapor momentum that comes to the bubble with vapor molecules. The latter force is somewhat diminished if condensation takes place at the upper bubble surface in subcooled liquids. The action of the said forces is opposed by inertia of the additional mass of liquid as the bubble center rises above the surface and by inertia of liquid being expelled by the growing bubble in radial directions. An extra pressure force arises due to the liquid inflow into the microlayer with a finite velocity. The last force helps in holding the bubble close to the surface during an initial stage of bubble evolution. Two limiting regimes with distinctly different properties can be singled out, depending on which of the forces that favor bubble detachment dominates. Under conditions of moderately reduced gravity, the situation is much the same as in normal gravity, although the bubble detachment volume increases as gravity diminishes. In microgravity, the buoyancy force is negligible. Then the bubble is capable of staying near the surface for a long time, with intensive evaporation from the microlayer. It suggests a drastic change in the physical mechanism of heat removal as gravity falls below a certain sufficiently low level. Inferences of the model and conclusions pertaining to effects caused on heat transfer processes by changes in bubble hydrodynamics induced by gravity are discussed in connection with experimental evidence, both available in current and in as yet unpublished literature.

Buyevich, Yu A.↗

Assembly and Integrated Systems Testing for the Flow Boiling and Condensation Experiment (FBCE)

The Flow Boiling and Condensation Experiment (FBCE) is a flight experiment that is designed to operate in the Fluids Integrated Rack (FIR) on the International Space Station (ISS). The objective of the FBCE is to develop an integrated two-phase flow experiment that will serve as a primary platform for obtaining flow boiling and condensation heat transfer data in microgravity. This data will enable the design and analysis of two-phase thermal management systems for future NASA missions that require increased efficiency beyond the current single-phase systems. The FBCE consists of seven modules, each of which must link together mechanically, electrically, and fluidically upon final integration. Five of the modules provide the fluidic and electronic components required to bring the test fluid to the inlet conditions required by the test module, where the primary science is conducted. These inlet conditions encompass fluid quality ranging from a superheated vapor to a subcooled liquid at a variety of flow rates and pressures. The FBCE is currently manufacturing two test modules, each of which has its own separate test campaign with the five support modules. Each of the modules presents a unique challenge in its assembly and checkout, particularly related to ensuring the final hardware configuration can meet the fluid and thermal requirements levied upon them. Following assembly, a series of flight verification tests will be performed, including thermal testing, EMI testing, and final integration in a FIR Ground Integration Unit. This presentation discusses the status of the FBCE as it continues through final verification testing, including current test results and lessons learned throughout the assembly and integration phase of the project. In addition, future options for additional flight test sections will be explored that will benefit the broader NASA thermal and fluids community.

deFiebre, Jesse↗

A Report from the Thermal Science Research Center (TSRC)

A vertical flow loop was designed and assembled to determine the local (circumferential and axial) and mean wall temperature distributions for single-phase and two-phase (subcooled and saturated) downward flow in both uniformly-heated and single-side heated vertical channels. Freon-11 was used as the working fluid in order to directly relate and compare the results with a previous experimental campaign which employed this same working fluid. For a given steady-state experiment, the following parameters were held constant: (1) exit pressure, (2) inlet temperature, and (3) mass velocity. For a given configuration of the 2.2 m long cylindrical channel test section, which had a 1.2 m long heated section, the applied heat rate was varied from zero through successive quasi-steady states to a level which corresponded to localized film boiling in the test section. The measurements showed that the boiling curve changes significantly at higher mass velocities with respect to both the circumferential and axial directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential directions. The slope of the boiling curve changes in a non-monotonic fashion with respect to the circumferential direction. The measurements point to the existence of a dry-out phenomenon occurring at multiple levels of the applied heat for the single-side heated channel. In comparing the heat transfer for horizontal channel flow with a vertically downward flow, the results show that significantly lower heat transfer occurs in the horizontal flow. However, this trend reverses as both the Reynolds number and the applied heat rate increase. Both the Liu-Winterton and Shah correlations were compared with the experimental data. The Shah correlation predicted the uniformly heated tube data better. When a thermal hydraulic diameter approach was used for the single-side heated case, the data at upstream locations for Z/L less than 0.5 was bounded above by the Liu-Winterton correlation and below by the Shah correlation. At Z/L = 0.5, the Shah correlation bounded the data; and for Z/L greater than 0.5, both correlations overpredicted the data with the Shah correlation being closest to the data. The present results indicate that additional correlational development is needed. In addressing some of the advanced space thermal management objectives concerning accommodating high heat fluxes in non-uniformly heated systems, a large battery of experiments 88 have been completed where local two-dimensional wall temperature variations were measured for both single-phase and two-phase flow in a single-side heated circular tube. As noted above, the results show significant axial and circumferential variations. Accurately accounting for such variations can result in optimized future advanced space, enhanced (high heat flux) thermal management systems.

Boyd, Ronald D.↗

Combined buoyancy and flow direction effects on saturated boiling critical heat flux in liquid nitrogen

Buoyancy effects on the critical heat flux and general data trends for a liquid nitrogen internal flow system were determined by comparison of upflow and downflow data under identical test conditions. The test section had a 1.28 cm diameter flow passage and a 30.5 cm heated length which was subjected to uniform heat fluxes through resistance heating. Test conditions covered a range of pressures from 3.4 to 10.2 atm, inlet velocities from 0.23 to 3.51 m/sec, with the liquid nitrogen temperature at saturated inlet conditions. Data comparisons showed that the critical heat flux for downflow could be up to 36 percent lower than for upflow. A nonmonotonic relationship between the critical heat flux and velocity was determined for upflow but not for downflow. A limiting inlet velocity of 4.12 m/sec was determined to be the minimum velocity required to completely suppress the influence of buoyancy on the critical heat flux for this saturated inlet flow system. A correlation of this limiting fluid velocity is presented that was developed from previously published subcooled liquid nitrogen data and the saturated data of this investigation.

Papell, S. S.↗

Flow Boiling Heat Transfer Characteristics of Water for Metal-foam-filled Horizontal Tubes

The goal of this paper is to enhance the in-tube flow boiling heat transfer of water while accounting for potential increase in pressure drop. Metal foams are a class of cellular structure with large surface-area-to-volume ratio and tortuous structure which has shown promising results for various energy conversion and storage applications. The higher heat transfer area and higher nucleation sites density due to the porous media can effectively enhance the heat transfer of water in both single-phase and two-phase operations. This paper presents the local heat transfer and pressure drop measurements of water in a partially metal-foam-filled horizontal copper tube. The ranges of parameters in the experiments are: mass flux from 80 to 200 kg/s-m2, heat flux from 3.5 to 105 kW/m2, and vapor quality from subcooled to 0.3. The results in the metal-foam-filled tube are compared with that of the bare copper tube. The effect of metal foam on the thermal hydraulic characteristics is discussed and analyzed. In addition, the two-phase flow behavior in a transparent tube filled with the same metal foam was visualized and investigated by high-speed imaging system. The experiments were also conducted in the tube without the metal foam for comparison.

Nawaz, Kashif↗