Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Study center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A study of LC-39 cryogenic systems. Part 1: A study of the vacuum insulated transfer lines at Kennedy Space Center. Part 2: Cooldown pressure surges

The vacuum liquid hydrogen and liquid oxygen transfer lines at Kennedy Space Center were studied to evaluate the feasibility of using a condensing gas such as CO2 inside the vacuum spaces to achieve a condensing-vacuum. The study indicates that at ambient temperature, a maximum vacuum hyphen space pressure of 4000 microns is acceptable for the LH2 transfer lines. In addition, the cooldown procedures for the 14-inch cross-country liquid oxygen line was studied using a simplified mathematical model. Preliminary cooldown times are presented for various heat leak rates to the line and for two vent configurations.

Ludtke, P. R.↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

South Repeater Building (Swmu 121) Pilot Study Work Plan, Kennedy Space Center, Florida

This document is a Pilot Study Work Plan for a groundwater remediation system at the South Repeater Building (N6-1118) located at the John F. Kennedy Space Center (KSC), Florida. Aqueous fire-fighting foam was applied near the building in the late 1990s during a wildfire. Per- and polyfluoroalkyl substances (PFAS) are components of the foam. Sampling completed at and near the South Repeater Building identified PFAS in groundwater, surface water and soil. KSC is planning to design and install a groundwater remediation system to address the potential for off-Center migration of PFAS compounds in groundwater. This Pilot Study Work Plan outlines subsurface hydrogeologic data that will be collected to use in the construction of a groundwater flow model that will guide the design of a full-scale remediation system. This document was prepared by AECOM Technical Services, Inc., for NASA under Indefinite Delivery Indefinite Quantity Contract 80KSC019D0010, Task Order 80KSC019F0096.

PFAS↗

Solar collector performance evaluated outdoors at NASA-Lewis Research Center

The study of solar reflector performance reported is related to a project in which solar collectors are to be provided for the solar heating and cooling system of an office building at NASA's Langley Research Center. The solar collector makes use of a liquid consisting of 50% ethylene glycol and 50% water. A conventional air-liquid heat exchanger is employed. Collector performance and solar insolation data are recorded along with air temperature, wind speed and direction, and relative humidity.

Vernon, R. W.↗

Lighting in Senior Care Centers: Comparing Tunable LED Systems to Conventional Lighting Systems in Four Senior Care Centers

This study was initiated to contribute to evidence-based practices for tunable light-emitting diode (LED) lighting upgrades in the future. The report summarizes Pacific Northwest National Laboratory (PNNL) evaluations of lighting conditions in four senior care centers in Wisconsin including energy savings analysis and non-image forming (NIF) response metric calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Geothermal Heat Pump Case Study: Westwood Hills Nature Center

Geothermal heat pumps can be great alternatives to air conditioners and furnaces, and require less electricity to run. This case study focuses on Westwood Hills Nature Center and is part of a series: https://www.energy.gov/eere/geothermal/geothermal-heat-pump-case-studies.

geothermal↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies: Beta Release

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. This report details the DML’s beta release, completed in July 2026. This is a revision and expansion of the alpha release, which was made available in January 2026 The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

electromagnetic transients↗

Comparison study of gear dynamic computer programs at NASA Lewis Research Center

A comparison study was performed on four gear dynamic analysis computer programs developed under NASA/Army sponsorship. These programs are GRDYNMULT (a multimesh program applicable to a number of epicyclic systems), TELSGE (a single mesh program), PGT (a multimesh program applicable to a planetary system with three planets), and DANST (a single mesh program). The capabilities and features, input and output options, and technical aspects of the programs were reviewed and compared. Results are presented in a concise tabular form. Parametric studies of the program models were performed to investigate the predicted results of the programs as input parameters such as speed, torque, and mesh damping were varied. In general, the program models predicted similar dynamic load and stress levels as operating conditions were varied. Flash temperature predictions from programs GRDYNMULT and TELSGE indicated similar trends; however, actual values were not in close agreement. The program GRDYNMULT was found to be the most versatile in system size, type, and analysis capabilities. The programs DANST, TELSGE, and PGT are more specialized for specific systems; however, in specific areas they provide a more detailed treatment than GRDYNMULT.

Zakrajsek, James J.↗

Aircraft measurements of electrified clouds at Kennedy Space Center. Part 2: Case study: 4 November 1988 (88309)

During the fall of 1988, a Schweizer airplane equipped to measure electric field and other meteorological parameters flew over Kennedy Space Center (KSC) in a program to study clouds defined in the existing launch restriction criteria. A case study is presented of a single flight over KSC on November 4, 1988. This flight was chosen for two reasons: (1) the clouds were weakly electrified, and no lightning was reported during the flight; and (2) electric field mills in the surface array at KSC indicated field strengths greater than 3 kV/m, yet the aircraft flying directly over them at an altitude of 3.4 km above sea level measured field strengths of less than 1.6 kV/m. A weather summary, sounding description, record of cloud types, and an account of electric field measurements are included.

Jones, J. J.↗

Surface convergence techniques and the prediction of lightning at Kennedy Space Center

This study compares two convergence techniques leading to the prediction of convective development and lightning: the area-averaged technique and a convergence cell approach. The area-averaged technique uses total area divergence across the network to identify the potential for new, local thunderstorm growth. A threshold of 75 x 10 to the -6th/s change in divergence is used to define a convergence event, and a separation of 30 minutes between flashes defines a lightning event. Convergence-lightning life cycles are found to be on the order of 1 hour from beginning convergence to first flash, and more than 2 hours from beginning convergence to the end of lightning. The convergence cell technique measures the strength of the convergence cell, which in turn leads to vertical development. Therefore, the likely lightning location and intensity can be ascertained in the larger network. Several cells can be monitored in the recently expanded Kennedy Space Center forecast network at the same time.

Watson, Andrew I.↗

Applications systems verification and transfer project. Volume 4: Operational applications of satellite snow cover observations. Colorado Field Test Center

The study was conducted on six watersheds ranging in size from 277 km to 3460 km in the Rio Grande and Arkansas River basins of southwestern Colorado. Six years of satellite data in the period 1973-78 were analyzed and snowcover maps prepared for all available image dates. Seven snowmapping techniques were explored; the photointerpretative method was selected as the most accurate. Three schemes to forecast snowmelt runoff employing satellite snowcover observations were investigated. They included a conceptual hydrologic model, a statistical model, and a graphical method. A reduction of 10% in the current average forecast error is estimated when snowcover data in snowmelt runoff forecasting is shown to be extremely promising. Inability to obtain repetitive coverage due to the 18 day cycle of LANDSAT, the occurrence of cloud cover and slow image delivery are obstacles to the immediate implementation of satellite derived snowcover in operational streamflow forecasting programs.

Shafer, B. A.↗

A continuation of base-line studies for environmentally monitoring space transportation systems at John F. Kennedy Space Center. Executive summary

Studies conducted in and around John F. Kennedy Space Center, Merrit Island, Florida were designed to establish baseline conditions for various attributes of the biotic and abiotic environment. Features were described and quantitatively measured. Certain condition were found to be appropriate for the detection and assessment of possible environmental perturbations caused by future NASA activities. These include plant communities, mammal populations, rainfall chemistry, fish populations, and the status of rare and endangered species. On the basis of statistical analysis of quantitative data and logistic considerations, it was possible to refine the kinds and amounts of measurements needed to evaluate perturbations in selected environmental components.

Stout, I. J.↗

National Aeronautics and Space Administration Manned Spacecraft Center data base requirements study

A study was conducted to evaluate the types of data that the Manned Spacecraft Center (MSC) should automate in order to make available essential management and technical information to support MSC's various functions and missions. In addition, the software and hardware capabilities to best handle the storage and retrieval of this data were analyzed. Based on the results of this study, recommendations are presented for a unified data base that provides a cost effective solution to MSC's data automation requirements. The recommendations are projected through a time frame that includes the earth orbit space station.

Source record↗

Data Center High-Temperature Liquid Cooling and Heat Reuse Techno-Economic Study: Preprint

Data centers are energy-intensive facilities with growing demands for efficiency and cost-effective operations. Smaller, more distributed edge inference data centers are expected to proliferate as AI applications require low latency closer to the user of AI tools, which presents a growing opportunity to explore the systems implications of liquid cooling on water and energy use. This study analyzes the implementation of high-temperature liquid cooling systems in a prototypical inference 1-MW data center and explores the potential for heat reuse across varying climates with a goal to optimize energy efficiency, reduce capital and operational costs, and identify opportunities for high-performance cooling and water use reduction infrastructure. This analysis evaluated configurations utilizing a peak day hourly sizing and systems performance spreadsheet to evaluate design and operational conditions from which component sizes, installed cost, operational cost, and performance metrics were determined for the Base case and the Elevated case. The techno-economic analysis included heat reuse applications across a range of heat recovery temperatures and heat rejection options. The analysis shows that high-temperature liquid cooling allows for improved energy efficiency, lower water consumption, and lower capital costs compared to traditional cooling approaches. Transitioning to elevated water inlet/outlet temperatures (50 degrees C/60 degrees C) eliminates the need for chillers, cooling towers, and heat recovery equipment in many scenarios across three distinct climate zones. This results in up to 75% capital cost savings for the cooling and heat recovery equipment, and with significantly reduced water consumption, especially in non-heat reuse applications. Heat generated from data centers can also be repurposed for space heating, domestic hot water, and other applications, and is most cost-effective when data center outlet temperatures exceed 55-60 degrees C.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies on color-center formation in glass utilizing measurements made during 1 to 3 MeV electron irradiation

The coloring of NBS 710 glass was studied using a facility for making optical absorption measurements during and after electron irradiation. The induced absorption contains three Gaussian shaped bands. The color center growth curves contain two saturating exponential and one linear components. After irradiation the coloring decays can be described by three decreasing exponentials. At room temperature both the coloring curve plateau and coloring rate increases with increasing dose rate. Coloring measurements made at fixed dose rate but at increasing temperature indicate: (1) The coloring curve plateau decreases with increasing temperature and coloring is barely measurable near 400 C. (2) The plateau is reached more rapidly as the temperature increases. (3) The decay occurring after irradiation cannot be described by Arrhenius kinetics. At each temperature the coloring can be explained by simple kinetics. The temperature dependence of the decay can be explained if it is assumed that the thermal untrapping is controlled by a distribution of activation energies.

Swyler, K. J.↗

CROCUS Tipping Bucket Rain Gauge Data from Argonne Deployable Mast Deployed at NEIU Carruthers Center for Inner City Studies (CCICS)

The Tipping Bucket Rain Gauge (TBRG) dataset contains data from a non-heated Met One 12-inch tipping bucket rain gauge that was mounted on the Argonne Deployable Mast (ADM). The ADM is a rapid deployable meteorological trailer that can be outfitted with instrumentation to measure urban heat island effects, urban flooding or urban flux measurements. During the urban flooding field campaign, the ADM was outfitted with multiple precipitation measurement systems, including the TBRG. This dataset contains one minute measurements for precipitation accumulation during the ADM's deployment at the Northeastern Illinois University (NEIU) Carruthers Center for Inner City Studies (CCICS) campus. These data are helpful for identifying periods of precipitation, leading to potential flooding. TBRGs can be used to validate optical rain gauge data and disdrometer data collected during the CROCUS urban flooding campaign. Data were collected at the CCICS building parking lot, located in the south side of Chicago, IL. The data is presented as daily NetCDF (.nc) files, each containing approximately 24 hours of observations. Files follow the naming convention of: the project (CROCUS), location (ADM-ccics), instrument name (tbrg), data level (raw, a1), and date (year, month, day). The NetCDF format can be accessed using common scientific software such as Python using xarray, netCDF4 or act-doe.

1-minute Precipitation Accumulation↗

Investigation of the launch pad abort capabilities of the HL-20 lifting body

The capability of the HL-20 lifting body spacecraft to perform an abort maneuver from the launch pad to a horizontal landing was studied at NASA Langley Research Center. This study involved both piloted and batch simulation models of the vehicle. A point-mass model of the vehicle was used for trajectory optimization studies. The piloted simulation was performed in the Visual Motion Simulator in fixed-base mode. A candidate maneuver was developed and refined for the worst-case launch-pad-to-landing-site geometry using an iterative procedure of off-line maneuver analysis followed by piloted evaluations and heuristic improvements to the candidate maneuver. The resulting maneuver demonstrates the launch site abort capability of the HL-20 and dictates requirements for nominal abort motor performance. The sensitivity of the maneuver to variations in several design parameters was documented.

Jackson, E. B.↗

Space Shuttle orbiter trimmed center-of-gravity extension study

Aerodynamic, heat transfer, and system design studies to determine removable modifications for the Space Shuttle orbiter that would extend its forward center-of-gravity triom capability are summarized. Wind-tunnel tests were conducted at Mach numbers ranging from 0.25 to 20.3 to determine the most effective aerodynamic modifications. Heat transfer and system design studies determined the impact of the modifications on the thermal protection system and structural weight of the vehicle. The most effective modifications were in-fillet canards or a forward extension of the existing forward wing fillet.

Scallion, W. I.↗