Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Stream or ponded width measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,219 records · Page 8

Introduction to Radiation Issues for International Space Station Extravehicular Activities: Chapter 1

The International Space Station (ISS) provides significant challenges for radiation protection of the crew due to a combination of circumstances including: the extended duration of missions for many crewmembers, the exceptionally dynamic nature of the radiation environment in ISS orbit, and the necessity for numerous planned extravehicular activities (EVA) for station construction and maintenance. Radiation protection requires accurate radiation dose measurements and precise risk modeling of the transmission of high fluxes of energetic electrons and protons through the relatively thin shielding provided by the space suits worn during EVA. Experiments and analyses have been performed due to the necessity to assure complete radiation safety for the EVA crew and thereby ensure mission success. The detailed characterization described of the material and topological properties of the ISS space suits can be used as a basis for design of space suits used in future exploration missions. In radiation protection practices, risk from exposure to ionizing radiation is determined analytically by the level of exposure, the detrimental quality of the radiation field, the inherent radiosensitivity of the tissues or organs irradiated, and the age and gender of the person at the time of exposure. During low Earth orbit (LEO) EVA, the relatively high fluxes of low-energy electrons and protons lead to large variations in exposure of the skin, lens of the eye, and tissues in other shallow anatomical locations. The technical papers in this publication describe a number of ground-based experiments that precisely measure the thickness of the NASA extravehicular mobility unit (EMU) and Russian Zvezda Orlan-M suits using medical computerized tomography (CT) X-ray analysis, and particle accelerator experiments that measure the minimum kinetic energy required by electrons and photons to penetrate major components of the suits. These studies provide information necessary for improving the understanding of the current ISS space suits and provide insights into improved approaches for the design of future suits. This chapter begins with a summary of the dynamic ionizing radiation environment in LEO space and introduces the concepts and quantities used to quantify exposure to space radiation in LEO. The space suits used for EVA and the experimental partial human phantom are described. Subsequent chapters report results from measured charged particle fields before and after incident protons and secondary particles are transported through the space suits and into organs and tissues.

M R Shavers

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Material efficiency technologies in the food and beverage industry

The U.S. food and beverage (F&B) sector is a major contributor to manufacturing gross domestic product and supports substantial employment and economic activity, while exerting significant pressures on land and water resources. At the same time, the industry faces growing expectations to balance its resource-intensive operations without compromising cost competitiveness. Material inefficiencies across the F&B value chain, particularly in raw material use and product loss/waste, lead to substantial financial losses and resource depletion. Thus, the F&B sector requires adoption of solutions and measures to avoid food wastage, reduce raw material consumption and valorize waste to high-value added products. This work presents a comprehensive understanding of the various technology solutions available for the F&B sector. The following two research questions are addressed: “What are the mid-to-high Technology Readiness Level technologies or measures to reduce material use and enable waste valorization in the F&B sector? What are the barriers to their commercial deployment? Additionally, what targeted research and development efforts are needed to overcome these barriers and accelerate their scale-up?” The findings are intended to support evidence-based decision-making, guide strategic investment, and help stakeholders strengthen resilience and competitiveness across the F&B sector.

Nain, Preeti [ORNL] (ORCID:0000000258358959)

Detecting Magnon-phonon coupling in yttrium iron garnet with variable temperature STEM-EELS

Magnons, quanta of spin wave excitations in magnetically ordered materials, have been identified as candidates for several potentially transformative technologies in recent years. Macroscopic techniques, such as neutron scattering or Raman spectroscopy, can be used to identify and analyze magnons, but provide relatively delocalized information about the sample. Understanding how the bonding and local structure of a material interacts with, and influences, the magnon population in a material is a crucial step toward the ability to produce any real-world application utilizing magnons. By leveraging the combined spatial resolution of scanning transmission electron microscopy (STEM) and the energy resolution of monochromated electron energy-loss spectroscopy (EELS) nanoscale analysis of magnons can be performed. While the weak interaction of magnons with the electron beam makes magnon EELS challenging on reasonable timescales, magnon-phonon coupling can be leveraged to understand magnons through their effect on the more easily measured phonons. Here, we examine yttrium iron garnet (YIG) flakes, and demonstrate non-linear, temperature-dependent shifts in the phonon frequencies, consistent with previously described magnon-phonon coupling effects. The ability to measure the temperature-dependence of vibrational frequencies with high precision in individual nanoscale flakes, demonstrates the ability to study magnon-phonon coupling in the STEM with unprecedented spatial resolution.

Reifsnyder, Alexander [ORNL]

Ground-Based Microwave Measurements of ClO and O3 Over Scott Base, Antarctica

We present measurements from a new microwave instrument that has been deployed at Scott Base, Antarctica, primarily to measure ClO. The new instrument allows for the extension of the time series of lower stratospheric ClO measurements begun in 1996 at this site, while some of the technical improvements offer the possibility of making additional measurements. We show measurements of ClO and O 3 in both the upper and lower stratosphere near both the fall and spring equinox and document the diurnal variations of these measurements throughout the season. The ground-based measurements are compared with Aura Microwave Limb Sounder (MLS) measurements, which are available twice per day, and with a NASA Goddard 2D model (GSFC2D) simulation. We show that, in agreement with the GSFC2D model diurnal variations, upper stratospheric ClO mixing ratios gradually increase throughout the daylight hours, while in the lower stratospheric austral spring, when heterogeneous chemistry associated with polar stratospheric clouds occurs, daily maximum ClO mixing ratios of near 2 ppbv occur near noon. We also show measurements of stratospheric O 3 , primarily in the upper stratosphere, which, while exhibiting a low bias of ∼15%–20% relative to Aura MLS, show temporal variations in good agreement with MLS.

stratospheric ozone

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

Measurement of Interfacial Tension of Immiscible Liquid Pairs in Microgravity

A discussion is given of a containerless microgravity experiment aimed at measuring the interfacial tension of immiscible liquid pairs using a compound drop rotation method. The reasons for the failure to execute such experiments in microgravity are described. Also, the results of post-flight analyses used to confirm our arguments are presented.

Michael C Weinberg

Cyclic Peptides for Lanthanide Binding

Lanthanide ions are difficult to separate from one another due to their similar chemical properties. The discovery of lanthanide-binding peptides and proteins in nature has led to an increased interest in the possibility of utilizing the strong binding of peptides to lanthanide ions for their separations; as such, there has been an effort to identify or design peptides with improved lanthanide binding and selectivity toward particular lanthanide ions. Here, in this study, we designed and characterized lanthanide-binding cyclic peptides (LBCPs) with molecular dynamics simulations, electronic structure calculations, and emission spectroscopy. Luminescent decay measurements were done to determine the number of water molecules coordinated to the Eu 3+ ion in Eu-LBCP complexes and compare to the predicted number of water molecules by computation to assess the lanthanide-binding affinity of LBCPs. Measured stability constants show binding of the LBCPs to the Eu 3+ ion with stronger than micromolar affinity. We were able to identify multiple peptides that selectively bind to middle lanthanides. We describe the structural basis of the lanthanide-binding selectivity trend with strongest binding to the middle lanthanides, followed by the heavier lanthanides, and finally to the lighter ions.

ions

Tracing the Source of Carbon Oxides on the Large Moons of Uranus

The Uranian moons Ariel, Umbriel, Titania, and Oberon are enriched in CO 2 mixed with CO, but the origin(s) of these carbon oxides, be they primarily native or radiolytic, remain(s) uncertain. Using data collected by NIRSpec on the James Webb Space Telescope (JWST), we measured the spectral signature of CO 2 and other carbon oxides to help disentangle these hypotheses. Through comparison to laboratory data, we find that many of the detected spectral features are consistent with CO 2 ice, including 12 CO2 scattering peaks (4.15–4.26 μm), multilobe 13 CO 2 bands (4.35–4.43 μm), and CO 2 biphonon and triphonon modes (4.80–5.25 μm). Our measurements show that CO 2 and CO are concentrated on the trailing hemispheres of the inner moons Ariel and Umbriel, potentially supporting a radiolytic production hypothesis, consistent with prior ground-based results. However, many of the identified spectral features are only observed in thick crystalline ice deposits measured in the laboratory, which may be difficult to form via radiolysis of carbon-bearing material mixed in icy regoliths. Similarly, the data exhibit weak 4.02 and 4.40 μm bands, hinting at the presence of carbonate minerals and 13 CO 2 clathrates, respectively, possibly formed in the interiors of these moons. Furthermore, JWST has revealed that CO 2 is widespread at Uranus, present in its system of rings, ring moons, and irregular satellites, consistent with its largest moons accreting CO 2 and other carbon oxides from the Uranian subnebula. We conclude that exposed carbon oxides are potentially native, with their surface distributions shaped by charged particle irradiation and seasonal sublimation–condensation cycles.

Ice spectroscopy

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi