Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Steam compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Status Report on the High-Temperature Steam Electrolysis Plant Model Developed in the Modelica Framework (FY17)

This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year 2015 (FY15), Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY16, INL developed two additional subsystems in the Modelica framework: (1) a high-temperature steam electrolysis (HTSE) plant as a high priority industrial plant to be integrated with a light water reactor (LWR) within an N-R HES and (2) a gas turbine power plant as a secondary energy supply. In FY17, five new components (i.e., a feedwater pump, a multi-stage compression system, a sweep-gas turbine, flow control valves, and pressure control valves) have been incorporated into the HTSE system proposed in FY16, aiming to better realistically characterize all key components of concern. Special attention has been given to the controller settings based on process models (i.e., direct synthesis method), aiming to improve process dynamics and controllability. A dynamic performance analysis of the improved LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. The analysis (evaluated in terms of the step response) clearly shows that the FY17 model resulted in superior output responses with much smaller settling times and less oscillatory behavior in response to disturbances in the electric load than those observed with the FY16 model. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the steam utilization factor, cathode stream inlet composition, and temperatures and pressures of the process streams at various locations) within desired limits under various plant operating conditions. The results also indicate that the proposed HTSE plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES.

08 HYDROGEN↗

Process for capturing CO{sub 2} arising from the calcination of the CaCO{sub 3} used in cement manufacture

This paper outlines a new CaCO{sub 3} calcination method for producing a stream of CO{sub 2} (suitable for permanent geological storage after purification and compression). The process is based on the use of very hot CaO particles (T {gt} 1000{sup o}C) to transfer heat from a circulating fluidized bed combustor (CFBC) to a calciner (fluidized with CO{sub 2} and/or steam). Since the fluidized bed combustor and calciner have separate atmospheres, the CO{sub 2} resulting from the decomposition of CaCO{sub 3} can be captured, while the CO{sub 2} generated in the combustion of the fuel in air is emitted to the atmosphere. We demonstrate that with this system it is possible to reduce the CO{sub 2} emissions of a cement plant by around 60%. Furthermore, since the key pieces of equipment are similar to the commercial CFBCs used in power generation plants, it is possible to establish the additional investment required for the system and to estimate the cost per ton of CO{sub 2} avoided for this process to be about 19 $/tCO{sub 2} avoided. 19 refs., 4 figs.

01 COAL, LIGNITE, AND PEAT↗

High Temperature Test Facility At Scale Testing, Validation, and Demonstration

Theses slides will be used to brief the Tribal DOE and Council Chairman for the project listed below. The High Temperature Test Facility (HTTF) is a demonstration-scale high temperature electrolysis (HTE) system that provides the ability to produce, process, store, and dispense electrolytically produced hydrogen. The system will be designed to accommodate electrolysis systems from various industry partners. The HTTF will be supplied up to 10 MW of power for electrolysis at 5 separate test article locations, each up to 2MW. The system will include post-processing and compression, storage, and capabilities to provide hydrogen for consumption by future end users. The HTTF will also provide the ability to test and demonstrate an HTE system in a configuration that would simulate the use of a nuclear generated steam supply for the high temperature heat source. The HTTF will be located at the Central Facilities Area (CFA) adjacent to CFA-686 on the INL site, 45 miles west of Idaho Falls.

08 HYDROGEN↗

Integrated Cyber/Physical Impact Analysis to secure US Critical Infrastructure

In a common electric power plant, heat is used to boil water into steam which drives a turbine. The steam from the turbine outlet is condensed with cooling water. This is the common Rankine cycle and, even after decades of development is relatively inefficient and water intensive. Alternatively, a closed Brayton cycle recirculates the working fluid, and the turbine exhaust is used in a recuperating heat exchanger to heat the turbine feed. A "supercritical cycle' is a closed Brayton cycle in which the working fluid, such as supercritical carbon dioxide (sCO2), is maintained above the critical point during the compression phase of the cycle. The key property of the fluid near its critical point is its higher gas density, closer to that of a liquid than of a gas, allowing for the pumping power in the compressor to be significantly reduced resulting in improved efficiency. Other advantages include smaller component size and the reduced use of water, not only due to the increased efficiency, but also due sensible heat rejection which facilitates dry air cooling compared to air-cooled steam condensers. A Sandia National Laboratories commercialization review concluded that the technology has applicability across various power generation applications including fossil fuels, concentrated solar power and nuclear power. In 2006, Sandia National Laboratories (SNL), recognizing the potential advantages of a higher efficiency power cycle, used internal funds to establish a testing capability and began partnering with the U.S. Department of Energy Office of Nuclear Energy to develop a laboratory-scale test assembly to show the viability of the underlying science and demonstrate system performance. Since that time, SNL has generated power, verified cycle performance, and developed cycle controls and maintenance procedures. The test assembly has successfully operated in different configurations (simple Brayton, waste heat cycle, and recompression) and tested additives to the s-CO2 working fluid. Our current focus is to partner with industry and develop cycle components and control strategies sufficient to support a successful commercial offering. This paper has been developed for the Energy Policy Institute's (EPI's) 6th Annual Energy Policy Research Conference scheduled for 8 & 9 September 2016 in Santa Fe, NM. We describe the cycle in more detail and describe specific benefits and applications. The paper will also include current technology development activities and future plans.

20 FOSSIL-FUELED POWER PLANTS↗

Comparison of well-to-wheels energy use and emissions of a hydrogen fuel cell electric vehicle relative to a conventional gasoline-powered internal combustion engine vehicle

The operation of hydrogen fuel cell electric vehicles (HFCEVs) is more efficient than that of gasoline conventional internal combustion engine vehicles (ICEVs), and produces zero tailpipe pollutant emissions. However, the production, transportation, and refueling of hydrogen are more energy- and emissions-intensive compared to gasoline. In this research, a well-to-wheels (WTW) energy use and emissions analysis was conducted to compare a HFCEV (Toyota Mirai) with a gasoline conventional ICEV (Mazda 3). Two sets of specific fuel consumption data were used for each vehicle: (1) fuel consumption derived from the U.S. Environmental Protection Agency's (EPA's) window-sticker fuel economy figure, and (2) weight-averaged fuel consumption based on physical vehicle testing with a chassis dynamometer on EPA's five standard driving cycles. The WTW results show that a HFCEV, even fueled by hydrogen from a fossil-based production pathway (via steam methane reforming of natural gas), uses 5%–33% less WTW fossil energy and has 15%–45% lower WTW greenhouse gas emissions compared to a gasoline conventional ICEV. The WTW results are sensitive to the source of electricity used for hydrogen compression or liquefaction.

33 ADVANCED PROPULSION SYSTEMS↗

Plant-wide simulation model for transient studies on the XE-100 - 18464

This paper gives an overview of the plant-wide simulation model that is used by X-energy LLC for developing their plant design and control philosophy, as well as assessing plant upset conditions. The simulation model was created in Flownex{sup R} thermal-fluid system simulation software, which solves mass, momentum and energy equations for compressible, incompressible and homogeneous two-phase flow. The plant model encompasses all major components, from reactor to condenser, including main control loop elements. The paper pays particular attention to the validation of the two-phase flow framework used for the secondary steam cycle. Two steady-state validation cases are done using operational data from the THTR. Validation of transient operation is done by simulating density wave oscillations, a type of system-level boiling phenomenon. This is regarded as a thorough test of transient capability because of the challenges this phenomenon poses to several aspects of the calculation and to the consistency of the code as a whole. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimal Synthesis of a Pulverized Coal Power Plant with Carbon Capture

Coal constitutes an important source of fuel for the production of power in the United States. For instance, in January 2009, pulverized coal (PC) power plants alone contributed to over 45 percent of the Nation's total electric power production. However, PC power plants also contribute to increased emissions of greenhouse gases principally carbon-dioxide (CO2). Recently, various carbon capture strategies have been under active investigation so as to make these plants compete with the more environmental friendly renewable energy sources. One such technology that has received considerable success is the capture of CO2 by an amine-based solvent extraction process. However, an aqueous absorption/stripping technology when used in a PC power plant can reduce the net power output of the plant by as much as 20-40%. The energy penalty comes from heating up the solvent in the regenerator, balancing the enthalpy of reaction, and water stripping. This energy penalty poses considerable limitations on commercial viability of the solvent extraction process and, as a result, various energy-saving modifications have been proposed in the literature ranging from the use of hybrid solvents to novel stripper configurations. In this paper, we show that the energy penalty can be further reduced by heat integration of various PC plant components with the carbon capture system. In addition to the release of greenhouse gases to the environment, PC plants also consume a large amount of freshwater. It is estimated that subcritical and supercritical PC plants have water losses of 714 gal/MWh and 639 gal/MWh, respectively. Water loss is based on an overall balance of the plant source and exit streams. This includes coal moisture, air humidity, process makeup, cooling tower makeup (equivalent to evaporation plus blowdown), process losses (including losses through reactions, solids entrainment, and process makeup/blowdown) and flue gas losses. The primary source of water used in PC power plants is the closed-loop steam-based (Rankine) power cycles. These plants need to condense large quantities of low-pressure steam back to water so that it can be reused to produce high pressure steam. However, this requires the removal of large quantities of heat from the low pressure steam in the condensation process. This is usually done by transferring the heat to cooling water, which in turn transfers this heat to the environment by evaporation to the atmosphere. Also, the inclusion of a carbon capture process can increase the raw water usage by as much as 95 percent. In this work, we use heat exchanger network synthesis followed by an optimization approach to process synthesis for developing strategies for reducing water use in a supercritical PC power plant with a carbon capture and compression system. Uncertainties associated with dry bulb temperature, relative humidity, and demand will also be considered in this analysis.

01 COAL, LIGNITE, AND PEAT↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evidence of Technetium and Iodine from a Sodalite-Bearing Ceramic Waste Form

Current plans for nuclear waste vitrification at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) lack the capacity to treat all of the low activity waste (LAW) that is not encapsulated in the vitrified product. Several technologies are being considered to treat the excess LAW. One such technology is Fluidized Bed Steam Reforming (FBSR). The FBSR process results in a granular product composed of feldspathoid mineral phases that immobilize the major components in the LAW as well as other contaminants of concern (COCs), with Tc and I expected to be present in sodalite cages formed during the process. In order to meet compressive strength requirements at the Hanford Integrated Disposal Facility (IDF), the granular product may be encapsulated in a monolith. To demonstrate the ability of the technology to serve the mission of managing excess LAW, Single Pass Flow-Through (SPFT) tests have been performed on non-radioactive granular materials and granular materials encapsulated in a geopolymer binder produced at the engineering- and bench-scale as well as a granular product produced at the bench scale with actual Hanford tank waste. SPFT tests were conducted at 40 °C for durations up to 2 months with a flow-through solution buffered at pH 9. The forward reaction rate of the non-radioactive mineral product dissolution based on Si release for the granular product was measured to be (6.2 ± 2.1) × 10-4 g/m2d for the engineering-scale product and (13 ± 4.9) × 10-4 g/m2d for the bench-scale product. The resulting non-radioactive monoliths showed forward reaction rates based on Si release of (3.4 ± 1.1) × 10-4 g/m2d for the engineering-scale material and (4.2 ± 1.5) × 10-4 g/m2d for the bench-scale material demonstrating that encapsulation of the FBSR granular product in a monolith does not significantly alter the performance of the material. Finally, an FBSR granular product created at the bench scale using actual Hanford LAW gave similar release values and also demonstrated that Re and Tc show similar release behavior with a dilute-condition release rate of (1.1 ± 0.5) × 10-4 g/m2d for Tc and (1.6 ± 0.6) × 10-4 g/m2d for Re. We believe that this is the first demonstration to show that Re and I have similar release behavior and that similar behavior of Re and Tc also occurs. These results indicate that the FBSR mineral product may be a suitable supplementary immobilization technique at the Hanford site and they also suggest that both Tc and Re occupy similar sites in the sodalite cage structure.

fluidized bed steam reforming↗

Development of a Turnkey Hydrogen Fueling Station Final Report

The transition to hydrogen as a fuel source presents several challenges. One of the major hurdles is the cost-effective production of hydrogen in small quantities (less than 1MMscf/month). In the early demonstration phase, hydrogen can be provided by bulk distribution of liquid or compressed gas from central production plants; however, the next phase to fostering the hydrogen economy will likely include onsite generation and extensive pipeline networks to help effect a pervasive infrastructure. Providing inexpensive hydrogen at a fleet operator’s garage or local fueling station is a key enabling technology for direct hydrogen Fuel Cell Vehicles (FCVs). The objective of this project was to develop a comprehensive, turnkey, stand-alone, commercial hydrogen fueling station for FCVs with state-of-the-art technology that is cost-competitive with current hydrocarbon fuels. Such a station would promote the advent of the hydrogen fuel economy for buses, fleet vehicles, and ultimately personal vehicles. Air Products, partnering with the U.S. Department of Energy (DOE), The Pennsylvania State University, Harvest Energy Technology, and QuestAir, developed a turnkey hydrogen fueling station on the Penn State campus. Air Products aimed at designing a station that would have 65% overall station efficiency, 82% PSA (pressure swing adsorption) efficiency, and the capability of producing hydrogen at $3.00/kg (gge) H2 at mass production rates. Air Products designed a fueling station at Penn State from the ground up. This project was implemented in three phases. The first phase evaluated the various technologies available in hydrogen generation, compression, storage, and gas dispensing. In the second phase, Air Products designed the components chosen from the technologies examined. Finally, phase three entailed a several-month period of data collection, full-scale operation, maintenance of the station, and optimization of system reliability and performance. Based on field data analysis, it was determined by a proprietary hydrogen-analysis model that hydrogen produced from the station at a rate of 1500 kg/day and when produced at 1000 stations per year would be able to deliver hydrogen at a price of $3.03/kg (gge) H2. The station’s efficiency was measured to be 65.1%, and the PSA was tested and ran at an efficiency of 82.1%, thus meeting the project targets. From the study, it was determined that more research was needed in the area of hydrogen fueling. The overall cost of the hydrogen energy station, when combined with the required plot size for scaled-up hydrogen demands, demonstrated that a station using steam methane reforming technology as a means to produce on–site hydrogen would have limited utility in the marketplace. Alternative hydrogen supplies, such as liquid or pipeline delivery to a refueling station, need to be included in the exploration of alternative energy site layouts. These avenues need to be explored before a definitive refueling station configuration and commercialization pathway can be determined.

08 HYDROGEN↗

Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced “F”-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus® is converted to an Aspen Plus Dynamics® simulation and integrated with MATLAB® for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportional–integral–derivative (PID) control is considered for the syngas pressure control. For maintaining the desired CO{sub 2} capture rate while load-following, a linear model predictive controller (LMPC) is implemented in MATLAB®. A combined process and disturbance model is identified by considering a number of model forms and choosing the final model based on an information-theoretic criterion. The performance of the LMPC is found to be superior to the conventional PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

01 COAL, LIGNITE, AND PEAT↗

Optimal integrated design of air separation unit and gas turbine block for IGCC systems

The Integrated Gasification Combined Cycle (IGCC) systems are considered as a promising technology for power generation. However, they are not yet in widespread commercial use and opportunities remain to improve system feasibility and profitability via improved process integration. This work focuses on the integrated design of gasification system, air separation unit (ASU) and the gas turbine (GT) block. The ASU supplies oxygen to the gasification system and it can also supply nitrogen (if required as a diluent) to the gas turbine block with minimal incremental cost. Since both GT and the ASU require a source of compressed air, integrating the air requirement of these units is a logical starting point for facility optimization (Smith et al., 1997). Air extraction from the GT can reduce or avoid the compression cost in the ASU and the nitrogen injection can reduce NOx emissions and promote trouble-free operation of the GT block (Wimer et al., 2006). There are several possible degrees of integration between the ASU and the GT (Smith and Klosek, 2001). In the case of 'total' integration, where all the air required for the ASU is supplied by the GT compressor and the ASU is expected to be an elevated-pressure (EP) type. Alternatively, the ASU can be 'stand alone' without any integration with the GT. In this case, the ASU operates at low pressure (LP), with its own air compressor delivering air to the cryogenic process at the minimum energy cost. Here, nitrogen may or may not be injected because of the energy penalty issue and instead, syngas humidification may be preferred. A design, which is intermediate between these two cases, involves partial supply of air by the gas turbine and the remainder by a separate air compressor. These integration schemes have been utilized in some IGCC projects. Examples include Nuon Power Plant at Buggenum, Netherlands (both air and nitrogen integration), Polk Power Station at Tampa, US (nitrogen-only integration) and LGTI at Plaquemine, US (stand-alone). However, there is very little information on systematic assessment of air extraction, nitrogen injection and configuration and operating conditions of the ASU and it is not clear which scheme is optimal for a given IGCC application. In this work, we address the above mentioned problem systematically using mixed-integer optimization. This approach allows the use of various objectives such as minimizing the investment and operating cost or SOx and NOx emissions, maximizing power output or overall efficiency or a weighted combination of these factors. A superstructure is proposed which incorporates all the integration schemes described above. Simplified models for ASU, gas turbine system and steam cycle are used which provide reasonable estimates for performance and cost (Frey and Zhu, 2006). The optimal structural configuration and operating conditions are presented for several case studies and it is observed that the optimal solution changes significantly depending on the specified objective.

97 MATHEMATICS AND COMPUTING↗

Low Temperature Combustion with Thermo-Chemical Recuperation to Maximize In-Use Engine Efficiency

The key to overcome Low Temperature Combustion (LTC) load range limitations in reciprocating engines is based on proper control over the thermo-chemical properties of the in-cylinder charge. The studied alternative to achieve the required control of LTC is the use of two separate fuel streams to regulate timing and heat release at specific operational points, where the secondary fuel is a reformed product of the primary fuel in the tank. It is proposed in this report that the secondary fuel can be produced using exhaust heat and Thermo-Chemical Recuperation (TCR). TCR for reciprocating engines is a system that employs high efficiency recovery of sensible heat from engine exhaust gas and uses this energy to transform fuel composition. The recuperated sensible heat is returned to the engine as chemical energy. Chemical conversions are accomplished through catalytic and endothermic reactions in a specially designed reforming reactor. An equilibrium model developed by Gas Technology Institute (GTI) for heptane steam reforming was applied to estimate reformed fuel composition at different reforming temperatures. Laboratory results, at a steam/heptane mole ratio less than 2:1, confirm that low temperature reforming reactions, in the range of 550 K to 650 K, can produce 10-30% hydrogen (by volume, wet) in the product stream. Also, the effect of trading low mean effective pressure for displacement to achieve power output and energy efficiency has been explored by WVU. A zerodimensional model of LTC using heptane as fuel and a diesel Compression Ignition (CI) combustion model were employed to estimate pressure, temperature and total heat release as inputs for a mechanical and thermal loss model. The model results show that the total cooling burden on an LTC engine with lower power density and higher displacement was 14.3% lower than the diesel engine for the same amount of energy addition in the case of high load (43.57mg fuel/cycle). These preliminary modeling and experimental results suggest that the LTC-TCR combination may offer a high efficiency solution to engine operation. A single zone model using a detailed chemical kinetic mechanism was implemented in CHEMKIN and to study the effects of base fuel and steam-fuel reforming products on the ignition timing and heat release characteristics. The study was performed considering the reformed fuel species composition for total n-heptane conversion (ideal case) and also at the composition corresponding to a specific set of operational reforming temperatures (real case). The computational model confirmed that the reformed products have a strong influence on the low temperature heat release (LTHR) region, affecting the onset of the high temperature heat release (HTHR). The ignition timing was proportionally delayed with respect to the baseline fuel case when higher concentrations of reformed gas were used. For stoichiometric concentration of RG, it was found that by increasing the proportion of reformed fuel to total fuel (RG), from 0% to 30%, the amount of energy released during the LTHR regime, or HR L , was reduced by 48% and the ignition timing was delayed 10.4 CA degrees with respect to the baseline fuel case. For RG composition corresponding to certain operational reforming temperatures, it was found that the most significant effects on the HCCI combustion, regarding HR L reduction and CA50 delay, was obtained by RG produced at a reforming temperature range of 675 K-725 K.

10 SYNTHETIC FUELS↗

Life-cycle implications of hydrogen fuel cell electric vehicle technology for medium- and heavy-duty trucks

This study provides a comprehensive and up-to-date life-cycle comparison of hydrogen fuel cell electric trucks (FCETs) and their conventional diesel counterparts in terms of energy use and air emissions, based on the ensemble of well-established methods, high-fidelity vehicle dynamic simulations, and real-world vehicle test data. For the centralized steam methane reforming (SMR) pathway, hydrogen FCETs reduce life-cycle or well-to-wheel (WTW) petroleum energy use by more than 98% compared to their diesel counterparts. The reduction in WTW air emissions for gaseous hydrogen (G.H2) FCETs ranges from 20-45% for greenhouse gases, 37-65% for VOC, 49-77% for CO, 62-83% for NOx, 19-43% for PM10, and 27-44% for PM2.5, depending on vehicle weight classes and truck types. With the current U.S. average electricity generation mix, FCETs tend to create more WTW SOx emissions than their diesel counterparts, mainly because of the upstream emissions related to electricity use for hydrogen compression/liquefaction. Compared to G.H2, liquid hydrogen (L.H2) FCETs generally provide smaller WTW emissions reductions. For both G.H2 and L.H2 pathways for FCETs, because of electricity consumption for compression and liquefaction, spatio-temporal variations of electricity generation can affect the WTW results. FCETs retain the WTW emission reduction benefits, even when considering aggressive diesel engine efficiency improvement.

air emissions↗

Integrated hydrogen generator and compressor with related method

An integrated hydrogen generator and compressor (200) that includes a combined engine compressor (collectively 109, 110, 111) and steam-methane reformer (104) to produce high-pressure hydrogen from natural gas (methane). The reformer (104) combines methane, water, and heat under high pressure in the presence of an appropriate catalyst, to produce hydrogen utilizing waste heat from combustion cylinders of the combined engine compressor (collectively 109, 110, 111). Compression serves to pressurize two different gases (methane and hydrogen) in different compression cylinders including the compression cylinders (109a, 109b, 109c) of the combined engine compressor (collectively 109, 110, 111) alternatively and/or optionally combined with internal combustion engine (310) and/or gas compressor(s) (410) that are integrated thermally and via communication of compressed gases.

08 HYDROGEN↗

Optimal Integrated Design of Air Separation Unit and Gas Turbine Block for IGCC Systems

The Integrated Gasification Combined Cycle (IGCC) systems are considered as a promising technology for power generation. However, they are not yet in widespread commercial use and opportunities remain to improve system feasibility and profitability via improved process integration. This work focuses on the integrated design of gasification system, air separation unit (ASU) and the gas turbine (GT) block. The ASU supplies oxygen to the gasification system and it can also supply nitrogen (if required as a diluent) to the gas turbine block with minimal incremental cost. Since both GT and the ASU require a source of compressed air, integrating the air requirement of these units is a logical starting point for facility optimization (Smith et al., 1997). Air extraction from the GT can reduce or avoid the compression cost in the ASU and the nitrogen injection can reduce NOx emissions and promote trouble-free operation of the GT block (Wimer et al., 2006). There are several possible degrees of integration between the ASU and the GT (Smith and Klosek, 2001). In the case of 'total' integration, where all the air required for the ASU is supplied by the GT compressor and the ASU is expected to be an elevated-pressure (EP) type. Alternatively, the ASU can be 'stand alone' without any integration with the GT. In this case, the ASU operates at low pressure (LP), with its own air compressor delivering air to the cryogenic process at the minimum energy cost. Here, nitrogen may or may not be injected because of the energy penalty issue and instead, syngas humidification may be preferred. A design, which is intermediate between these two cases, involves partial supply of air by the gas turbine and the remainder by a separate air compressor. These integration schemes have been utilized in some IGCC projects. Examples include Nuon Power Plant at Buggenum, Netherlands (both air and nitrogen integration), Polk Power Station at Tampa, US (nitrogen-only integration) and LGTI at Plaquemine, US (stand-alone). However, there is very little information on systematic assessment of air extraction, nitrogen injection and configuration and operating conditions of the ASU and it is not clear which scheme is optimal for a given IGCC application. In this work, we address the above mentioned problem systematically using mixed-integer optimization. This approach allows the use of various objectives such as minimizing the investment and operating cost or SOx and NOx emissions, maximizing power output or overall efficiency or a weighted combination of these factors. A superstructure is proposed which incorporates all the integration schemes described above. Simplified models for ASU, gas turbine system and steam cycle are used which provide reasonable estimates for performance and cost (Frey and Zhu, 2006). The optimal structural configuration and operating conditions are presented for several case studies and it is observed that the optimal solution changes significantly depending on the specified objective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing A Fully Implicit Compressible Flow Valve Model in RELAP-7 and Its Application in Short Term BWR Station Black-Out Analyses

This paper presents a set of dynamical models for SRV simulation and their implementation in the RELAP-7 code, which is a new reactor system analysis code being developed at INL. RELAP-7 is based on the MOOSE (the Multi-Physics Object-Oriented Simulation Environment) framework. The compressible flow SRV model covers three different sets of models: fully closed case, subsonic case, and choking case. The RELAP-7 is a fully implicit code and the preconditioned Jacobian-free Newton-Krylov (JFNK) method is used to solve the discretized nonlinear problem. The JFNK method generally needs a good preconditioning scheme to be effective and efficient. There are different ways to precondition the JFNK method. In RELAP-7, two main options are used to obtain the preconditioning matrix: (1) FDP (Finite Difference Preconditioning) option which uses the default finite differencing method provided in the PETSc package. PETSc is the numerical solver software developed by Argonne National Laboratory and used by MOOSE as the numerical solution engine; (2) SMP (Single Matrix Preconditioning) option which requires code developers to provide approximate analytical Jacobian inputs for the important diagonal and off-diagonal terms. Due to the strong discontinuity in the residual vector space when the compressible flow valve model switches from one set of model to another, FDP option cannot guarantee convergence. Instead, accurate analytical Jacobain terms are provided for the compressible flow valve model. With the SMP option selected, the compressible flow valve model can be solved efficiently under different cases. The developed compressible flow valve model has been used for SRV component simulation in several simplified BWR SBO (Station Black-Out) simulations with RELAP-7. This paper only presents cases for short-term SBO in which all the safety systems fail to start and function properly when SBO occurs. Consequently, only the SRVs automatically open and close periodically to control the primary system pressure and discharge the high temperature and high pressure steam into the suppression pool. Although simplified, this case is quite similar to what happened in Fukushima Daiichi Unit 1. Unit 1 had no RCIC system, while the isolation condenser system was believed to be non-functioning, or only available for a very short period of time during the accident. Therefore, the Unit 1 reactor core reached a fuel failure temperature only a few hours into the accident. Two short-term SBO cases will be compared: one with single SRV discharge line which represents all the SRV lines and another case with multi-group SRVs which represent each group of SRV line with different setting points.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗