Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Software Verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

MAMA Software Features: Errors, Uncertainty, and Standards

This document reviews the sources of uncertainty, standards, and the UQ development plan for the MAMA software. Our intention is to allow users to generate quantification data with uncertainty based on the contributing back end sources. We do not intend to add in front end uncertainty into the software itself, due to the numerous different instruments that could be used, and the enormous variation in factors that would add to that uncertainty among different users, samples, and sample prep routines. We could not possibly or reasonably address them all. We will however, add in the uncertainty component from the image scale bar, which must be provided by the user as an input to the software, and could be used to incorporate any front end uncertainty. (Note: the detailing of these front end uncertainties is beyond the scope of this software effort.) The verification testing we have done generates uncertainties that are fundamentally pixel based. Given the uncertainty in the scale bar, we can then propagate the uncertainty and convert to uncertainty in all calculated results in microns (or whatever unit the scale bar is in.) Users can then add any additional instrumentation and sample prep uncertainty to the resulting output as appropriate for the data calculation and analysis being performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Transport [Slides]

We present an overview of radiation transport, covering terminology, blackbody radiation, opacities, Boltzmann transport theory, approximations to the transport equation. Next we introduce several transport methods. We present a section on Caseology, observing transport boundary layers. We briefly broach topics of software development, including verification and validation, and we close with a section on high energy-density experiments that highlight and support radiation transport.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of accuracy of calculations of VVER-1000 core states with incomplete covering of fuel by the absorber

An additional verification of bundled software (BS) SAPFIR-95 and amp;RC [1] and code KORSAR/GP [2] was performed. Both software products were developed in A.P. Alexandrov NITI and certified by ROSTEKHNADZOR of RF for numeric simulation of stationary, transitional and emergency conditions of VVER reactors. A benchmark model for neutronics calculations was created within the limits of this work. The cold subcritical state of VVER - 1000 reactor stationary fuelling was simulated on the basis of FA with an increased height of the fuel column (TVS-2M) considering detailed presentation of radial and front neutron reflectors. A case of passing of pure condensate slug through the core in initially deep subcritical state during start of the first RCP set after refueling was considered as an examined condition of reactor operation. A relatively small size of the slug, its spatial position near the reflectors (lower and lateral), as well as failure of the inserted control rods of the control and protection system (CPS CR) to reach the lower limit of the fuel column stipulate for methodical complexity of a correct calculation of the neutron multiplication constant (K{sub eff}) using engineering codes. Code RC was used as a test program in the process of reactor calculated 3-D modeling. Code MCNP5 [3] was used as the precision program, which solves the equation of neutrons transfer by Monte-Carlo method and which was developed in the US (Los-Alamos). As a result of comparative calculations dependency of K{sub eff} on two parameters was evaluated - boron acid concentration (Cb) and CPS CR position. Reactivity effect was evaluated, which is implemented as a result of failure of all CPS control rods to reach the lower fuel limit calculated using the engineering codes mentioned above. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MFANS 2024 - Formally Proving Characteristics of Cyber-Physical Systems

Cyber-physical systems (CPS) are engineered systems that rely on the smooth integration of computational algorithms and physical elements. This integration presents new challenges for verifying that systems will behave as expected. The goal of this presentation is to present current challenges and potential solutions for the formal verification of cyber-physical systems. For cyber systems, formal methods refer to systematically rigorous mathematical techniques employed in the specification, development, analysis, and verification of both software and hardware systems. Recent advancements in computer science have yielded sophisticated tools specifically designed to address challenges associated with formal methods in complex systems. These tools leverage various foundational concepts such as logic, formal languages, program semantics, type systems, type theory, and automata theory. A notable achievement in the application of formal methods is the seL4 microkernel, claimed to be the first general-purpose operating-system kernel to be verified. Its proof implies the absence of bugs and guarantees that the kernel meets specifications. For physical systems, dynamic and control theory has a history of using rigorous analytic techniques to prove functional correctness. Lyapunov, optimal, classical, modern, and robust control theories all provide rigorous mathematical methods both to analyze system performance and to design controller that can be guaranteed to meet certain objectives. Recent computational techniques like level set theory and reachability analysis provide assertions that a system's state will avoid unsafe regions. Even though success has been independently achieved for cyber systems and physical systems, the integration of such systems creates new challenges. In particular, there is an obvious discrepancy between finite-state machines and infinite-state systems, resulting in different approaches for modeling and analyzing these system. While it is possible to simulate hybrid systems, this provides only a demonstration of a performance and not proof. For hybrid systems, current formal methods and system analysis approaches typically require a workarounds to work on hybrid systems like CPS. This paper will outline the state of the art and limits of current practice for formally verifying CPS and will identify possible research directions that require attention.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-442: Sensitivity of Quality Assurance Tools to Delivery Errors On a Magnetic Resonance-Imaging Guided Radiation Therapy (MR-IGRT) System

Purpose: To test the sensitivity of the quality assurance (QA) tools actively used on a clinical MR-IGRT system for potential delivery errors. Methods: Patient-specific QA procedures have been implemented for a commercially available Cobalt-60 MR-IGRT system. The QA tools utilized were a MR-compatible cylindrical diode-array detector (ArcCHECK) with a custom insert which positions an ionization chamber (Exradin A18) in the middle of the device, as well as an in-house treatment delivery verification program. These tools were tested to investigate their sensitivity to delivery errors. For the ArcCHECK and ion chamber, a baseline was established with a static field irradiation to a known dose. Variations of the baseline were investigated which included rotated gantry, altered field size, directional shifts, and different delivery time. In addition, similar variations were tested with the automated delivery verification program that compared the treatment parameters in the machine delivery logs to the ones in the plan. To test the software, a 3-field conformal plan was generated as the baseline. Results: ArcCHECK noted at least a 13% decrease in passing rate from baseline in the following scenarios: gantry rotation of 1 degree from plan, 5mm change in field size, 2mm lateral shift, and delivery time decrease. Ion chamber measurements remained consistent for these variations except for the 5 second decrease in delivery time scenario which resulted in an 8% difference from baseline. The delivery verification software was able to detect and report the simulated errors such as when the gantry was rotated by 0.6 degrees, the beam weighting was changed by a percent, a single multileaf collimator was moved by 1cm, and the dose was changed from 2 to 1.8Gy. Conclusion: The results show that the current tools used for patient specific QA are capable of detecting small errors in RT delivery with presence of magnetic field.

60 APPLIED LIFE SCIENCES↗

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

A Knowledge-based Framework for Building Energy Model Performance Verification

Building energy modeling (BEM) has been widely used by researchers, regulators, and engineers to quantify building energy performance. Quality assurance (QA) and quality control (QC) of the model's performance are essential parts of such analysis. Currently, QA/QC is done in a manual and ad-hoc manner, which is tedious, error-prone, and time-consuming when QA/QC a large number of models. To solve these challenges, we propose a a dAta-driveN buIlding perforMance verificATion framEwork (ANIMATE), which conducts automated output-based verification of building operations requirements (especially for time-series output-based verification of control requirements). While this framework was developed for verifying energy model performance, it can be extended for other applications such as BEM software testing and performance verification of real buildings in the field.

Chen, Yan↗

CI/CD Efforts for Validation, Verification and Benchmarking OpenMP Implementations

Software developers must adapt to keep up with the changing capabilities of platforms so that they can utilize the power of High-Performance Computers (HPC), including exascale systems. OpenMP, a directive-based parallel programming model, allows developers to include directives to existing C, C++, or Fortran code to allow node level parallelism without compromising performance. This paper describes our CI/CD efforts to provide easy evaluation of the support of OpenMP across different compilers using existing testsuites and benchmark suites on HPC platforms. Our main contributions include (1) the set of a Continuous Integration (CI) and Continuous Development (CD) workflow that captures bugs and provides faster feedback to compiler developers, (2) an evaluation of OpenMP (offloading) implementations supported by AMD, HPE, GNU, LLVM, and Intel, and (3) evaluation of the quality of compilers across different heterogeneous HPC platforms. With the comprehensive testing through the CI/CD workflow, we aim to provide a comprehensive understanding of the current state of OpenMP (offloading) support in different compilers and heterogeneous platforms consisting of CPUs and GPUs from NVIDIA, AMD, and Intel.

Jarmusch, Aaron↗

Software Quality Assurance Plan for the Geochemist’s Workbench®

The Geochemist’s Workbench® (GWB) Release 10.0.10 is a geochemical modeling suite for simulating the reactive fate and transport of radionuclides and other metals in aqueous systems including groundwater, surface water, soil, and sediment. At the Savannah River National Laboratory, GWB plays an important role in the preparation of Performance Assessments involving cementitious materials. The software classification for GWB is Level “C.” GWB was purchased from Aqueous Solutions LLC and came into existence outside of the Software Quality Assurance procedures; therefore, it is considered “existing/acquired” software. This Software Quality Assurance Plan addresses verification techniques and the required life cycle components for Level “C” existing/acquired software (i.e., “Evaluation,”“Configuration Control,” and “Cyber Security Analysis”) with other elements optionally applied using a graded approach.

58 GEOSCIENCES↗

Methodology and Software for Gross Defect Detection of Spent Nuclear Fuel at the Atucha-I Reactor [Novel Methodology and Software for Spent Fuel Gross Defect Detection at the Atucha-I Reactor]

Here, fuel assemblies in the spent fuel pool are stored by suspending them in two vertically stacked layers at the Atucha Unit 1 nuclear power plant (Atucha-I). This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 wt% 235 U and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A gross defect detection tool, the spent fuel neutron counter (SFNC), has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups, the existing signal processing software of the tool was found to fail due to nonlinearity of the source term with burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimization Methodology of Pebble Bed HTGR Start-Up and Running-in Strategy

In recent years interest in advanced reactor technologies has increased significantly. However, the methods used for analysis of traditional nuclear reactors are insufficient to consider all the different and varied advanced reactor designs without further development. One promising advanced reactor design is the pebble bed reactor (PBR). PBRs possess unique operational and fuel cycle features that require the development of specific analysis methodologies to adequately design and analyze the systems. There is a need in PBR research for a capability to analyze and optimize the process of transitioning from the start-up reactor core to the equilibrium core (known as the “running-in” of the reactor). The start-up of a PBR and the transition to the equilibrium core is a complex, multi-physics challenge that has not yet been well researched and has many opportunities for design, analysis, and optimization of the process. In this research, a methodology is defined to consider the potential strategies in PBR start-up and run-in to the equilibrium core. Multiple candidate software are considered, and their pros and cons are discussed for the PBR-specific application in the methodology. A preliminary software selection for the physics engine is made, and initial verification of key modules is performed. Software to support optimization of the reactor run-in strategies through reduced order modeling (ROM) and machine learning are considered. Challenges for a full implementation of the methodology are discussed. Additional code selections and verification of models relevant to the application are needed before full demonstration of the methodology can be achieved and an optimal strategy determined.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Land Ice Verification and Validation Kit

To address a pressing need to better understand the behavior and complex interaction of ice sheets within the global Earth system, significant development of continental-scale, dynamical ice-sheet models is underway. The associated verification and validation process of these models is being coordinated through a new, robust, python-based extensible software package, the Land Ice Verification and Validation toolkit (LIVV). This release provides robust and automated verification and a performance evaluation on LCF platforms. The performance V&V involves a comprehensive comparison of model performance relative to expected behavior on a given computing platform. LIVV operates on a set of benchmark and test data, and provides comparisons for a suite of community prioritized tests, including configuration and parameter variations, bit-4-bit evaluation, and plots of tests where differences occur.

Source record↗

Land Ice Verification and Validation Kit

To address a pressing need to better understand the behavior and complex interaction of ice sheets within the global Earth system, significant development of continental-scale, dynamical ice-sheet models is underway. The associated verification and validation process of these models is being coordinated through a new, robust, python-based extensible software package, the Land Ice Verification and Validation toolkit (LIVV). This release provides robust and automated verification and a performance evaluation on LCF platforms. The performance V&V involves a comprehensive comparison of model performance relative to expected behavior on a given computing platform. LIVV operates on a set of benchmark and test data, and provides comparisons for a suite of community prioritized tests, including configuration and parameter variations, bit-4-bit evaluation, and plots of tests where differences occur.

Source record↗

SU-E-T-03: 3D GPU-Accelerated Secondary Checks of Radiation Therapy Treatment Plans

Purpose: Redundant treatment verifications in conformal and intensity-modulated radiation therapy techniques are traditionally performed with single point calculations. New solutions can replace these checks with 3D treatment plan verifications. This work describes a software tool (Mobius3D, Mobius Medical Systems) that uses a GPU-accelerated collapsed cone algorithm to perform 3D independent verifications of TPS calculations. Methods: Mobius3D comes with reference beam models for common linear accelerators. The system uses an independently developed collapsed cone algorithm updated with recent enhancements. 144 isotropically-spaced cones are used for each voxel for calculations. These complex calculations can be sped up by using GPUs. Mobius3D calculate dose using DICOM information coming from TPS (CT, RT Struct, RT Plan RT Dose). DVH-metrics and 3D gamma tests can be used to compare both TPS and secondary calculations. 170 patients treated with all common techniques as 3DCFRT (including wedged), static and dynamic IMRT and VMAT have been successfully verified with this solution. Results: Calculation times are between 3–5 minutes for 3DCFRT treatments and 15–20 for most complex dMLC and VMAT plans. For all PTVs mean dose and 90% coverage differences are (1.12±0.97)% and (0.68±1.19)%, respectively. Mean dose discrepancies for all OARs is (0.64±1.00)%. 3D gamma (global, 3%/3 mm) analysis shows a mean passing rate of (97.8 ± 3.0)% for PTVs and (99.0±3.0)% for OARs. 3D gamma pasing rate for all voxels in CT has a mean value of (98.5±1.6)%. Conclusion: Mobius3D is a powerful tool to verify all modalities of radiation therapy treatments. Dose discrepancies calculated by this system are in good agreement with TPS. The use of reference beam data results in time savings and can be used to avoid the propagation of errors in original beam data into our QA system. GPU calculations permit enhanced collapsed cone calculations with reasonable calculation times.

60 APPLIED LIFE SCIENCES↗

Final Technical Report on Quantifying Dependability Attributes of Software Based Safety Critical Instrumentation and Control Systems in Nuclear Power Plants

With the current transition from analog to digital instrumentation and control systems in nuclear power plants, the number and variety of software-based systems have significantly increased. The sophisticated nature and increasing complexity of software raises trust in these systems as a significant challenge. The trust placed in a software system is typically termed software dependability. Software dependability analysis faces uncommon challenges since software systems’ characteristics differ from those of hardware systems. The lack of systematic science-based methods for quantifying the dependability attributes in software-based instrumentation as well as control systems in safety critical applications has proved itself to be a significant inhibitor to the expanded use of modern digital technology in the nuclear industry. Dependability refers to the ability of a system to deliver a service that can be trusted. Dependability is commonly considered as a general concept that encompasses different attributes, e.g., reliability, safety, security, availability and maintainability. Dependability research has progressed significantly over the last few decades. For example, various assessment models and/or design approaches have been proposed for software reliability, software availability and software maintainability. Advances have also been made to integrate multiple dependability attributes, e.g., integrating security with other dependability attributes, measuring availability and maintainability, modeling reliability and availability, quantifying reliability and security, exploring the dependencies between security and safety and developing integrated analysis models. However, there is still a lack of understanding of the dependencies between various dependability attributes as a whole and of how such dependencies are formed. To address the need for quantification and give a more objective basis to the review process -- therefore reducing regulatory uncertainty -- measures and methods are needed to assess dependability attributes early on, as well as throughout the life-cycle process of software development. In this research, extensive expert opinion elicitation is used to identify the measures and methods for assessing software dependability. Semi-structured questionnaires were designed to elicit expert knowledge. A new notation system, Causal Mechanism Graphing, was developed to extract and represent such knowledge. The Causal Mechanism Graphs were merged, thus, obtaining the consensus knowledge shared by the domain experts. In this report, we focus on how software contributes to dependability. However, software dependability is not discussed separately from the context of systems or socio-technical systems. Specifically, this report focuses on software dependability, reliability, safety, security, availability, and maintainability. Our research was conducted in the sequence of stages found below. Each stage is further examined in its corresponding chapter. Stage 1 (Chapter 2): Elicitation of causal maps describing the dependencies between dependability attributes. These causal maps were constructed using expert opinion elicitation. This chapter describes the expert opinion elicitation process, the questionnaire design, the causal map construction method and the causal maps obtained. Stage 2 (Chapter 3): Elicitation of the causal map describing the occurrence of the event of interest for each dependability attribute. The causal mechanisms for the “event of interest” were extracted for each of the software dependability attributes. The “event of interest” for a dependability attribute is generally considered to be the “attribute failure”, e.g. security failure. The extraction was based on the analysis of expert elicitation results obtained in Stage 1. Stage 3 (Chapter 4): Identification of relevant measurements. Measures for the “events of interest” and their causal mechanisms were obtained from expert opinion elicitation for each of the software dependability attributes. The measures extracted are presented in this chapter. Stage 4 (Chapter 5): Assessment of the coverage of the causal maps via measures. Coverage was assessed to determine whether the measures obtained were sufficient to quantify software dependability, and what measures are further required. Stage 5 (Chapter 6): Identification of “missing” measures and measurement approaches for concepts not covered. New measures, for concepts that had not been covered sufficiently as determined in Stage 4, were identified using supplementary expert opinion elicitation as well as literature reviews. Stage 6 (Chapter 7): Building of a detailed quantification model based on the causal maps and measurements obtained. Ability to derive such a quantification model shows that the causal models and measurements derived from the previous stages (Stage 1 to Stage 5) can form the technical basis for developing dependability quantification models. Scope restrictions have led us to prioritize this demonstration effort. The demonstration was focused on a critical system, i.e. the reactor protection system. For this system, a ranking of the software dependability attributes by nuclear stakeholders was developed. As expected for this application, the stakeholder ranking identified safety as the most critical attribute to be quantified. A safety quantification model limited to the requirements phase of development was built. Two case studies were conducted for verification. A preliminary control gate for software safety for the requirements stage was proposed and applied to the first case study. The control gate allows a cost effective selection of the duration of the requirements phase.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-609: Evaluation of Transit Dosimetry Software Using Heterogeneous Phantom

Purpose: The purpose of this work was to evaluate limits and capabilities in the transit dosimetry software for use with the TomoTherapy system by irradiating a heterogeneous phantom. Methods: Helical TomoTherapy plan was created using CIRS phantom (model 062M) with nine various tissue equivalent inserts (lung inhale 0.2 g/cm{sup 3}, lung exhale 0.5 g/cm{sup 3}, adipose 0.96 g/cm{sup 3}, breast 0.99 g/cm{sup 3}, water 1.01 g/cm{sup 3}, muscle 1.06 g/cm{sup 3}, liver 1.07 g/cm{sup 3}, trabecular bone 1.16 g/cm{sup 3}, and dense bone 1.53 g/cm{sup 3}). Targets were contoured within every insert. The phantom was scanned with a 50 cm field of view and 3 mm slice width. Images were imported into the TomoTherapy TPS. A plan was generated to deliver 20 Gy to every insert (2 Gy per fraction) with a jaw width of 2.5 cm, a pitch of 0.430 and an actual modulation factor of 2.621. After the radiation delivery the planning CT, the RT structure, the RT plan, and the RT dose (DICOM format) as well as the exit detector sinogram were imported into the Dosimetry Check software (Math Resolutions, LLC). The 3D delivered doses were reconstructed from the exit detector data by correcting for phantom and couch attenuation. The resulting dose distribution were compared with the TPS planned dose using gamma index. Results: Using the clinical gamma criteria, 3% and 3 mm, all tissue equivalent inserts had a passing percentage of 100% except for 0.2 g/cm{sup 3} and 0.5 g/cm{sup 3} density inserts (gamma value of 81.67% and 99.18% respectively). Conclusion: The evaluated transit dosimetry software provides an independent verification of helical TomoTherapy plans giving additional confidence in the treatment delivery, however, an overestimation of the reconstructed dose in low density materials has been revealed. Implementation of Monte Carlo algorithm for exit dose reconstruction should improve dosimetric accuracy in heterogeneous patient tissues. Agreement with Math Resolutions.

60 APPLIED LIFE SCIENCES↗