Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation Cases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-Federate Co-Convergence with HELICS

In co-simulation studies, convergence refers to the ability of different simulation tools involved to achieve a consistent and stable solution. Convergence is a critical aspect of co-simulation as it determines the accuracy of the results obtained from the simulation. Convergence in co-simulation studies depends on several factors, this includes system complexity, the accuracy of the models used, and the numerical methods employed by the simulation tools. It is essential to ensure that the coupling interfaces between the different tools are designed to allow for data exchange in a consistent and accurate manner. Hierarchical Engine for Large-scale Infrastructure Co-Simulation (HELICS) is an open-source co-simulation framework developed for the energy domain. This paper explores the convergence performance of a set of co-simulation use cases. We further explore the use of a co-convergence helper federate to help with co-simulation convergence. The convergence efficacy of several algorithms (both gradient-based and gradient-free) is tested against these use cases. Finally, the sensitivity of these algorithms to several factors, such as system scaling and others, is tested and detailed in this paper. Our results show that for a subset of use cases, the co-convergence helper federate is able to improve co-simulation convergence significantly.

co-convergence↗

Process Failure Detection via Recurrence Quantification Analysis in a Slot-Rectangular Spouted Bed

A study was conducted to explore the applicability of recurrence and recurrence quantification analysis (RQA) to the detection of process failures in spouted bed reactor systems. Here, three different potential failure modes were examined in a transparent, cold flow slot-rectangular spouted bed. These being, a simulated air leak from a side wall of the reactor, a simulated gas leak from the top wall of the reactor, and simulated agglomeration of solids via introduction of larger “klinker” particles. Bed pressure drop time history data were collected and analyzed via generation of recurrence plots (RPs) and RQA parameters. In general, the simulated agglomeration case was quite easily detected via ever RQA Parameter examined, whereas the simulated air leaks were detected by only a single RQA parameter.

30 DIRECT ENERGY CONVERSION↗

Truchas Overview

Truchas and Truchas-PBF are two sister codes for part-scale multi-physics modeling of manufacturing processes. Both programs are open source and made publicly available. They’re designed for efficient use of HPC resources and can be programmatically driven from Python packages. This enables automatic execution and analysis of ensembles of simulations, in some cases allowing 1000s of simulations to be evaluated in a day on HPC. Beyond just giving engineers a window into the concealed internal state of a system, the goal of Truchas is to provide a framework for developing novel manufacturing processes by understanding how the entire space of engineering inputs affects thermal state. It often is used to explore combinations of capabilities uncommon in commercial software, or to scale up analyses beyond the capabilities of commercial software.

97 MATHEMATICS AND COMPUTING↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Verification and Validation of Open-Source Computational Fluid Dynamics Capabilities in MOOSE

The Multiphysics Object Oriented Simulation Environment (MOOSE) advances predictive modeling in nuclear research by simplifying the application design process and making modeling more efficient and accessible to researchers and the broader community. Because of MOOSE’s critical role in the scientific computation field, verification and validation are important to evaluate the reliability and credibility of MOOSE’s code, simulations, and models. To assess MOOSE’s Navier Stokes module and turbulence models, the following verification and validation University of Manchester ERCOFTAC cases were simulated in MOOSE, and the results were compared: Case 032 Turbulent Flow in a 2D Channel Case 079 Natural Convection in an Enclosed Cavity

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗

Influences of Cloud Microphysics on the Components of Solar Irradiance in the WRF-Solar Model

An accurate forecast of Global Horizontal solar Irradiance (GHI) and Direct Normal Irradiance (DNI) in cloudy conditions remains a major challenge in the solar energy industry. This study focuses on the impact of cloud microphysics on GHI and its partition into DNI and Diffuse Horizontal Irradiance (DHI) using the Weather Research and Forecasting model specifically designed for solar radiation applications (WRF-Solar) and seven microphysical schemes. Three stratocumulus (Sc) and five shallow cumulus (Cu) cases are simulated and evaluated against measurements at the US Department of Energy’s Atmospheric Radiation Measurement (ARM) user facility, Southern Great Plains (SGP) site. Results show that different microphysical schemes lead to spreads in simulated solar irradiance components up to 75% and 350% from their ensemble means in the Cu and Sc cases, respectively. The Cu cases have smaller microphysical sensitivity due to a limited cloud fraction and smaller domain-averaged cloud water mixing ratio compared to Sc cases. Cloud properties also influence the partition of GHI into DNI and DHI, and the model simulates better GHI than DNI and DHI due to a non-physical error compensation between DNI and DHI. The microphysical schemes that produce more accurate liquid water paths and effective radii of cloud droplets have a better overall performance.

54 ENVIRONMENTAL SCIENCES↗

Modeling receiver flux of commercial power tower concentrating solar power plants using ray tracing: a round-robin comparison of SolTrace, Solstice, and TieSOL

This study presents a multi-stage, cross-validation comparison of three software packages for Monte Carlo ray tracing (MCRT) applied to central tower concentrating solar power (CSP) systems. The three packages evaluated are: (1) SolTrace, an open-source tool developed by the National Renewable Energy Laboratory (NREL); (2) Solstice, an open-source program created by CNRS-PROMES and Meso-Star, with enhancements for CSP applications (called solsticepy) from the Australian National University; and (3) TieSOL, a commercial software developed by Tietronix. This investigation extends previous ray tracing comparisons by incorporating models of multi-facet heliostats within a commercial-scale solar field, taking into account zoned focal lengths and canting configurations. Receiver flux distributions were compared across the tools using a series of case studies, including single-heliostat scenarios, isolated blocking situations, and comprehensive full-field simulations. The case studies were designed to diagnose differences across the models at varying levels of complexity, and to identify and resolve discrepancies as additional parameters were introduced. Key factors examined in the analysis include sun positions, heliostat location, facet and canting focus, and aimpoint strategies. The comparison aims to improve the accuracy and reliability of these tools while providing benchmark cases for validating future optical modeling tools.

14 SOLAR ENERGY↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal mechanical assessment of a SiC-SiC-composite clad fuel pin concept in a light water reactor environment

Accident Tolerant Fuels (ATFs) are designed to increase coping time following an accident scenario while preserving or improving current steady state reactor operational performance. A potential ATF concept is SiC-SiC composite claddings. Fuel performance simulations were conducted on a SiC-SiC based cladding concept utilizing a multilayered approach for improved performance. This cladding concept referred to as the Duplex concept is a duplex structure composed of a monolithic SiC layer placed on the outside of a SiC-SiC composite. A liquid metal is added to fuel-cladding gap for improved heat dissipation from the fuel. The monolithic SiC layer is used to improve the coolant corrosion characteristics and protect the SiC-SiC composite layer from exposure to the coolant. The fuel performance code BISON was used to conduct fuel performance simulations on the cladding concepts. Comparisons are made with a current prototypic fuel rod design (UO 2 fuel enclosed in Zircaloy-4 cladding). Representative steady-state cases were considered for normal power and two cycle power histories. Additionally, a PCI ramp case was simulated to analyze potential anticipated operational occurrences. Transient response during a Loss of Coolant Accident and a Reactivity Initiated Accident were also simulated. This computational study demonstrated that for normal operating conditions, the SiC concept cladding performed as well as the baseline for the standard power cases evaluated. The ramping evaluations indicate potential fracturing of the SiC-SiC composite of the composite cladding compared to the Zircaloy-4 cladding due to the temperature gradient and the subsequent differential thermal conductivity degradation and swelling across the composite thickness. In conclusion, the rod fails early at low enthalpy for RIA but survives a LOCA with minimal material loss due to high temperature steam corrosion.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Surrogate-driven design optimization with uncertainty constraints in Monte Carlo simulations

In multi-objective design tasks, the computational cost increases rapidly when high-fidelity simulations are used to evaluate objective functions. Surrogate models help mitigate this cost by approximating the simulation output, simplifying the design process. However, under high uncertainty, surrogate models trained on noisy data can produce inaccurate predictions, as their performance depends heavily on the quality of training data. This study investigates the impact of data uncertainty on two multi-objective design problems modelled using Monte Carlo transport simulations: a neutron moderator and an ion-to-neutron converter. For each, a grid search was performed using five different tally uncertainty levels to generate training data for neural network surrogate models. These models were then optimized using NSGA-III. The recovered Pareto-fronts were analyzed across uncertainty levels: in the moderator problem, normalized hypervolume dropped from 0.886 at 1.0% uncertainty to 0.748 at 10% uncertainty, while in the converter problem it remained near 0.50 for all cases. Average simulation times were also compared to evaluate the trade-off between accuracy and computational cost. Results show that the influence of simulation uncertainty is strongly problem-dependent. In the neutron moderator case, higher uncertainties led to exaggerated objective sensitivities and distorted Pareto-fronts, reducing normalized hypervolume. In contrast, the ion-to-neutron converter task was less affected—low-fidelity simulations produced results similar to those from high-fidelity data. These findings suggest that a fixed-fidelity approach is not optimal. Surrogate models can recover the Pareto-front under noisy conditions, and multi-fidelity studies help identify suitable uncertainty levels for each problem to balance efficiency and accuracy.

07 ISOTOPE AND RADIATION SOURCES↗

Specific Ion and Electric Field Controlled Diverse Ion Distribution and Electroosmotic Transport in a Polyelectrolyte Brush Grafted Nanochannel

Controlling ion distribution inside a charged nanochannel is central to using such channels in diverse applications. Here, we show the possibility of using a charged polyelectrolyte (PE) brush grafted nanochannel for triggering diverse nanoscopic ion distribution and nanofluidic electroosmotic transport by controlling the valence and size of the counterions (that screen the charges of the PE brushes) and the strength of an externally applied axial electric field. We atomistically simulate separate cases of fully charged Polyacrylic acid (PAA) brush functionalized nanochannels with Na + , Cs + , Ca 2+ , Ba 2+ , and Y 3+ counterions screening the PE charges. Four key findings emerge from our simulations. First, we find that the counterions with a greater valence and a smaller size prefer to remain localized inside the brush layer. Second, for the case where there is an added chloride salt with the same cation (as the screening counterions), there are more coions (Cl - ions) in the brush-free bulk than counterions (for counterions Na + , Ca 2+ , Ba 2+ , Y 3+ ): this is a manifestation of the overscreening (OS) of the PE brush layer. Contrastingly, the number of Cs + ions remain higher than the Cl - ions inside the brush-free bulk, ensuring that there is no OS effect for this case. Third, large applied electric field enables a few Na + , Cs + , and Ba 2+ counterions to leave the brush layer and to go to the bulk: this makes the OS of the PE brush layer disappear for the cases of PE brushes being screened by the Na+ and Ba 2+ ions. On the other hand, no such electric-field-mediated disappearance of OS is observed for the cases of Ca 2+ and Y 3+ screening counterions; we attribute this to the firm attachment of these counterions to the negatively charged monomers. Free energy associated to a counterion binding to a PE chain corroborates this diversity in the counterion-specific response to the applied electric field. Lastly, we demonstrate that such diverse ion distributions, along with specific electric-field-strength-dependent ion properties, lead to (1) EOS transport in nanochannels grafted with PAA brushes screened with Cs + ions to be always counterion dominated, (2) EOS transport in nanochannels grafted with PAA brushes screened with Ca 2+ and Y 3+ ions to be always coion dominated, and (3) EOS transport in nanochannels grafted with PAA brushes screened with Na + and Ba 2+ ions to be coion dominated for smaller electric fields and counterion dominated for larger electric fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Importance of Being Adaptable: An Exploration of the Power and Limitations of Domain Adaptation for Simulation-Based Inference with Galaxy Clusters

The application of deep machine learning methods in astronomy has exploded in the last decade, with new models showing remarkably improved performance on benchmark tasks. Not nearly enough attention is given to understanding the models' robustness, especially when the test data are systematically different from the training data, or "out of domain." Domain shift poses a significant challenge for simulation-based inference, where models are trained on simulated data but applied to real observational data. In this paper, we explore domain shift and test domain adaptation methods for a specific scientific case: simulation-based inference for estimating galaxy cluster masses from X-ray profiles. We build datasets to mimic simulation-based inference: a training set from the Magneticum simulation, a scatter-augmented training set to capture uncertainties in scaling relations, and a test set derived from the IllustrisTNG simulation. We demonstrate that the Test Set is out of domain in subtle ways that would be difficult to detect without careful analysis. We apply three deep learning methods: a standard neural network (NN), a neural network trained on the scatter-augmented input catalogs, and a Deep Reconstruction-Regression Network (DRRN), a semi-supervised deep model engineered to address domain shift. Although the NN improves results by 17% in the Training Data, it performs 40% worse on the out-of-domain Test Set. Surprisingly, the Scatter-Augmented Neural Network (SANN) performs similarly. While the DRRN is successful in mapping the training and Test Data onto the same latent space, it consistently underperforms compared to a straightforward Yx scaling relation. These results serve as a warning that simulation-based inference must be handled with extreme care, as subtle differences between training simulations and observational data can lead to unforeseen biases creeping into the results.

Ntampaka, Michelle [Baltimore, Space Telescope Sci↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FIDES-II/P2M Simulation Exercise on AN3 and AN10 bump tests: main results

This paper presents simulations of bump tests conducted as part of the P2M (Power to Melt and Maneuverability) project within the OECD/NEA FIDES-II framework (Framework for Irradiation Experiments). To prepare fuel performance codes for analyzing the P2M experiments, an international Simulation Exercise (SE) was initiated under the P2M project. The objective of this exercise was to model the AN3 and AN10 bump tests carried out in the 1980s at the DR3 reactor (3rd RISØ Fission Gas Project), during which instrumented fuel rodlets (equipped with thermocouples and pressure sensors) were subjected to prolonged power transients and power dips. The ongoing simulation exercise involves seven organizations from industry, research, and regulatory bodies, each using different fuel performance codes. This paper provides detailed descriptions of the test cases and simulation results from six fuel performance codes (ALCYONE, BISON, FAST, FEMAXI, FRAPCON, and TRANSURANUS), with a particular focus on fission gas release kinetics.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detector alignment for X-ray crystallography using Millepede-II

I describe a method for accurately refining the geometrical parameters of segmented X-ray area detectors on the basis of serial crystallography data, using 'Millepede' – an algorithm created for a very similar problem in high-energy physics. The Millepede method for serial crystallography builds on the approach of Brewster et al. [Acta Cryst. (2018), D74, 877–894], in which the detector parameters are refined simultaneously with the parameters for each individual crystal. This accounts for the mutual dependency between the parameters and thereby avoids the bias and slow convergence problems that have afflicted older approaches in which the deviations between observed and calculated Bragg peak positions were taken directly as the updates for the detector panel positions. The Millepede method uses the special structure of the least-squares normal equations to reduce them to a much smaller form that can be solved very quickly, even compared with the sparse matrix methods used previously. This makes it practical to refine the detector geometry frequently and thereby maintain accurate calibration without specialized alignment campaigns. Tilts of detector panels out of the plane can be reliably refined, as can the overall distance of the detector in the beam direction. With a simulated test case, the new method produced panel shifts within 7% of the correct values with only one iteration, and produced almost exactly correct shifts after a second iteration. A simulated out-of-plane panel rotation was correctly determined to within 0.001°. Applied to experimental data from an X-ray free-electron laser, the method increased the indexable fraction of frames from 30% to 91% in a single iteration, and to 96% after two further iterations. Computing the geometry updates on the basis of 2060 crystals took only 0.819 s on desktop computing hardware, including the time taken to read the required data from disk. The scaling was found to be very close to linear for up to 100 980 sets of crystal parameters, which took only 78.2 s to process under the same conditions. The method has been applied as part of a real-time feedback system at a synchrotron radiation beamline, in which an out-of-plane detector tilt of 0.04° was detected and corrected. Possible further applications are also described here.

Millepede-II↗

Unsaturated alluvium disposal modelling with improved geological realism

This report describes specific activities in the Fiscal Year (FY) 2023 associated with the Geologic Disposal Safety Assessment (GDSA) Repository Systems Analysis (RSA) work package funded by the Spent Fuel and Waste Science and Technology (SFWST) Campaign of the U.S. Department of Energy Office of Nuclear Energy (DOE-NE), Office of Spent Fuel and Waste Disposition (SFWD). The overall objective of the GDSA RSA work package is to develop generic deep geologic repository concepts and system performance assessment (PA) models in several potential host-rock environments, and to simulate and analyze these generic repository concepts and models using the GDSA Framework toolkit and other tools as needed. The specific GDSA goal addressed in this report is reference case development, simulation, and analysis for the unsaturated alluvium (UZ), one of the four potential host-rocks considered by the GDSA. Further, we aim to exercise the simulation tools and methodologies under development by GDSA for PA modelling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modelling of sawtooth-induced fast ion transport in positive and negative triangularity in TCV

Internal kinks are a common magneto hydro-dynamic (MHD) instability observed in tokamak operation when the q profile in the plasma core is close to unity. This MHD instability impacts both the transport of the bulk plasma (current, particle and energy transport) and minority species, such as fast ions. In TCV (R 0 /a = 0.88 m/0.25 m) the fast ion population is generated in the plasma by neutral beam tangential injection of energies up to 28 keV. TCV features 16 active shaping coils permitting a great flexibility in plasma shape, including negative triangularity (δ) configurations that show surprisingly high confinement. This study focuses on the transport of fast ions induced by sawteeth, by comparing two triangularity cases and simulation results with experimental data. Comparison of two equilibria with opposite δ shows that the fast ion drifts are larger for δ < 0. Furthermore, the sawtooth-induced transport in this case is larger than δ > 0 in similar conditions. Additionally, comparison with experimental data confirms the dominance of the modification of thermal kinetic profiles following the sawtooth crash in explaining drops in the neutron rates and FIDA signals. Additional fast ion diffusion, however, improves the interpretation of the experimental data. For δ < 0, the amplitude of the perturbation better representing the experimental data is larger. Finaly, an exploratory study for 50 keV particles (soon available in TCV) shows that the situation does not worsen for such particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗