Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SiB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Boron capture stabilizing the diffusion barriers in a two-step Mo-Si-B coated refractory multi-principal element alloy

A Mo-Si-B based coating has been applied on a refractory multi-principal element alloy (RMPEA) using a two-step coating strategy and has endured more than 750 hours of thermal cycling oxidation exposure between room temperature to 1300°C with a minimal weight change. Here, the formation of the Mo 5 SiB 2 diffusion barrier in the coating prevents the inward diffusion of the coating components. Then, boron is captured by the RMPEA, resulting in the formation of a solid solution X 5 SiB 2 (X= W, Mo, Ta, Nb, V) layer and an RMPEA-B boride layer underneath it that acts as the second diffusion barrier.

36 MATERIALS SCIENCE↗

Polyanion-type iron-based sulfate cathode materials: From fundamental research to industrialization

Sodium-ion batteries (SIBs) with the merits of abundant sodium resources and low cost are considered significant supplements to lithium-ion batteries in large-scale energy storage systems. Among the discovered cathode materials for SIBs, iron-based sulfate materials have attracted widespread attention due to their high operating voltage, superior structural stability, and high safety. Here, in this review, we summarize the research achievements of iron-based sulfate cathode materials in fundamental research, as well as provide a comprehensive overview of its industrialization progress for the first time. Meanwhile, effective modification strategies (including morphology design, hybridization with carbon materials, and construction of heterostructure) and further research directions to boost the sodium storage performance of iron-based sulfate cathode materials are also proposed. This review can provide valuable guidance for developing high-performance iron-based sulfate cathode materials for practical application.

cathode materials↗

Whole Brain Radiotherapy With Hippocampal Avoidance and Simultaneous Integrated Boost for 1-3 Brain Metastases: A Feasibility Study Using Volumetric Modulated Arc Therapy

Purpose: To evaluate the feasibility of using volumetric modulated arc therapy (VMAT) to deliver whole brain radiotherapy (WBRT) with hippocampal avoidance and a simultaneous integrated boost (SIB) for one to three brain metastases. Methods and Materials: Ten patients previously treated with stereotactic radiosurgery for one to three brain metastases underwent repeat planning using VMAT. The whole brain prescription dose was 32.25 Gy in 15 fractions, and SIB doses to brain metastases were 63 Gy to lesions >=2.0 cm and 70.8 Gy to lesions <2.0 cm in diameter. The mean dose to the hippocampus was kept at <6 Gy{sub 2}. Plans were optimized for conformity and target coverage while minimizing hippocampal and ocular doses. Plans were evaluated on target coverage, prescription isodose to target volume ratio, conformity number, homogeneity index, and maximum dose to prescription dose ratio. Results: Ten patients had 18 metastases. Mean values for the brain metastases were as follows: conformity number = 0.73 +- 0.10, target coverage = 0.98 +- 0.01, prescription isodose to target volume = 1.34 +- 0.19, maximum dose to prescription dose ratio = 1.09 +- 0.02, and homogeneity index = 0.07 +- 0.02. For the whole brain, the mean target coverage and homogeneity index were 0.960 +- 0.002 and 0.39 +- 0.06, respectively. The mean hippocampal dose was 5.23 +- 0.39 Gy{sub 2}. The mean treatment delivery time was 3.6 min (range, 3.3-4.1 min). Conclusions: VMAT was able to achieve adequate whole brain coverage with conformal hippocampal avoidance and radiosurgical quality dose distributions for one to three brain metastases. The mean delivery time was under 4 min.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grade 3/4 Dermatitis in Head and Neck Cancer Patients Treated With Concurrent Cetuximab and IMRT

Purpose: To assess the rate of serious (>Grade 2, CTCAE 3.0) dermatitis in our head-and-neck cancer (HNC) patients undergoing simultaneous integrated boost intensity-modulated radiotherapy with concomitant cetuximab (SIB-IMRT-cetuximab). We hypothesized a positive association between the radiation dose to the skin and the degree of dermatitis in patients receiving cetuximab. Methods and Materials: Between April 2006 and December 2009, 99 HNC patients underwent SIB-IMRT-cetuximab. In 69/99 (70%), systemic treatment consisted of concomitant cetuximab only, whereas 30 (30%) were switched from concomitant cisplatin to concomitant cetuximab. Treatment-related dermatitis was prospectively monitored. Ninety-nine patients treated with four to seven concomitant cycles of cisplatin only served as an internal control group. The radiation dose delivered to the skin was measured and related to dermal reactions. Results: Grade 3/4 dermatitis developed in 34% of the cetuximab cohort, which was substantially higher than in the control cohort (3%, p < 0.01). No cases of skin necrosis or other fatal events related to cetuximab have occurred so far. A significantly larger mean skin area was found exposed to high radiation doses in patients with severe cetuximab-related dermatitis, compared with those without (p < 0.01). Conclusion: Concomitant cetuximab resulted in a {approx}10-fold increase in the rate of severe transient dermatitis compared with the use of concomitant cisplatin. We found a positive association between the incidence of Grade 3/4 dermatitis and the radiation dose delivered to the skin in patients receiving cetuximab.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Versus Conventional Intensity-Modulated Radiation Therapy for Primary Chemoradiation in Cervical Cancer Patients: An Intraindividual Comparison

Purpose: To compare intensity-modulated radiotherapy (IMRT) delivered by helical tomotherapy (HT) with conventional IMRT for primary chemoradiation in cervical cancer patients. Methods and Materials: Twenty cervical cancer patients undergoing primary chemoradiation received radiation with HT; 10 patients underwent pelvic irradiation (PEL) and 10 extended-field irradiation (EXT). For treatment planning, the simultaneously integrated boost (SIB) concept was applied. Tumor, pelvic, with or without para-aortic lymph nodes were defined as planning target volume A (PTV-A) with a prescribed dose of 1.8/50.4 Gy (28 fractions). The SIB dose for the parametrium (PTV-B), was 2.12/59.36 Gy. The lower target constraints were 95% of the prescribed dose in 95% of the target volume, and the upper dose constraint was 107%. The irradiated small-bowel volumes were kept as low as possible. For every HT plan, a conventional IMRT plan was calculated and compared with regard to dose-volume histogram, conformity index and conformity number, and homogeneity index. Results: Both techniques allowed excellent target volume coverage and sufficient SB sparing. Conformity index and conformity number results for both PTV-A and PTV-B, homogeneity index for PTV-B, and SB sparing for V45, V50, Dmax, and D1% were significantly better with HT. SB sparing was significantly better for conventional IMRT at low doses (V10). Conclusions: Both HT and conventional IMRT provide optimal treatment of cervical cancer patients. The HT technique was significantly favored with regard to target conformity, homogeneity, and SB sparing. Randomized trials are needed to assess the oncological outcome, toxicity, and clinical relevance of these differences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flattening Filter Free vs Flattened Beams for Breast Irradiation

Purpose: Flattening filter free (FFF) beams offer the potential for a higher dose rate, shorter treatment time, and lower peripheral dose. To investigate their role in large-field treatments, this study compared flattened and FFF beams for breast irradiation. Methods and Materials: Ten left breast clinical plans comprising 2 tangential beams and a medially located 3-field simultaneous integrated boost (SIB) were replanned. Full intensity modulated radiotherapy (IMRT), hybrid IMRT, electronic tissue compensator (ETC), and multiple static field treatment plans were created for the elective breast volume using flattened and FFF beams, in combination with a 3-field IMRT SIB. Plan quality was assessed and delivery times were measured for all plans for 1 patient. Out-of-field doses were measured using an ionization chamber for an IMRT plan optimized on a corner of simple cubic phantom for both flattened and FFF beams. Results: For each technique, mean target volume metrics (planning target volume coverage, homogeneity, conformity) were typically within 3% for flattened and FFF beams. Larger mean differences in boost conformity favoring flattened hybrid (7.2%) and full IMRT (5.5%) plans may have reflected limitations in plan normalization. Calculated heart and ipsilateral lung doses were comparable; however, both flattened and FFF low-dose phantom measurements were substantially higher than calculated values, rendering the comparison of low dose in the contralateral breast uncertain. Beam delivery times were on average 31% less for FFF. Conclusions: In general, target volume metrics for flattened and FFF plans were comparable. The planning system did not seem to allow for accurate peripheral dose evaluation. FFF was associated with a potentially shorter treatment time. All 4 IMRT techniques allowed FFF beams to generate acceptable plans for breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Toxicity and Tumor Response in Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy With Shortening of the Overall Treatment Time Using Intensity-Modulated Radiation Therapy With Simultaneous Integrated Boost: A Phase 2 Trial

Background and Purpose: This phase 2 study investigated the efficacy and safety of preoperative intensity modulated radiation therapy with a simultaneous integrated boost (IMRT-SIB) without dose escalation, concomitant with standard capecitabine chemotherapy in locally advanced rectal cancer. Methods and Materials: Between January 2014 and March 2015, 51 patients with operable stage II-III rectal adenocarcinoma received preoperative IMRT with pelvic dose of 41.8 Gy and simultaneously delivered 46.2 Gy to T2/3 and 48.4 Gy to T4 tumor in 22 fractions, concomitant with capecitabine, 825 mg/m{sup 2}/12 hours, including weekends. The primary endpoint was pathologic complete response (pCR). Results: Fifty patients completed preoperative treatment according to the protocol, and 47 underwent surgical resection. The sphincter preservation rate for the low rectal tumors was 62%, and the resection margins were free in all but 1 patient. Decrease in tumor and nodal stage was observed in 32 (68%) and 39 (83%) patients, respectively, with pCR achieved in 12 (25.5%) patients. There were only 2 G ≥ 3 acute toxicities, with infectious enterocolitis in 1 patient and dermatitis over the sacral area caused by the bolus effect of the treatment table in the second patient. Conclusions: Preoperative IMRT-SIB without dose escalation is well tolerated, with a low acute toxicity profile, and can achieve a high rate of pCR and downstaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale electro-chemo-mechanical model of high-capacity amorphous silicon anode material in sodium-ion batteries

The growing interest in sodium-ion batteries (SIBs) is fueled by their abundant resources and environmentally friendly nature, with amorphous silicon (a-Si) emerging as a promising anode material for enhancing capacity. However, the key challenge lies in sustaining reversible capacity during cycling. Here, in this work, we developed a multiscale electrochemical model incorporating an a-Si anode to elucidate the performance parameters of SIBs. Additionally, we integrated an electro-chemo-mechanical model at the particle level to capture stress generation, an essential factor in the degradation of high-capacity electrodes. Unlike existing models, our approach accounts for large-deformation chemo-mechanics at the particle scale and includes simulations under varying charge rates to explore multiscale behavior. The results reveal that coupled sodiation significantly prolongs complete cycling times and influences discharge dynamics, indicating that neglecting this coupling leads to an underestimation of actual capacity. Furthermore, we observed pronounced polarization effects at higher charge rates, resulting in heterogeneous stress distributions across the anode. With the identification of critical failure parameters for both active particles and binder materials, offering novel insights for mitigating degradation in high-capacity electrode systems.

Amorphous silicon anode↗

Mechanistic origin of solvent-dependent thermal stability in sodiated Sn anodes for sodium-ion batteries

Understanding the thermal stability of high-energy density alloy anodes is critical for the safe deployment of sodium-ion batteries (SIBs). Here, accelerating rate calorimetry (ARC), post-mortem characterizations, and density functional theory (DFT) calculations are combined to understand the thermal reactivity of fully sodiated Sn, Sn-hard carbon (HC) blends, and HC anodes in carbonate- and ether-based electrolytes. ARC measurements show that propylene carbonate (PC) causes earlier self-heating rate (SHR) onset and higher reactivity than tetraethylene glycol dimethyl ether (TEGDME), indicating inferior thermal stability. Sodiated Sn exhibits better thermal stability than sodiated HC, while Sn-HC blends show intermediate behavior that improves with increasing Sn content. Post-ARC analyses reveal desodiation of Na15Sn4 to metallic Sn with particle coalescence, whereas Sn-HC blends and HC retain finer morphologies. PC promotes Sn oxidation to SnO, while TEGDME suppresses oxide formation; NaPF6-containing electrolytes additionally form NaF. DFT calculations show that PC adsorption lowers Na extraction energy and enhances interfacial electronic interactions, facilitating Na release and reductive decomposition. These results establish a direct correlation between solvent-dependent reaction pathways and thermal stability in SIB alloy anodes.

Accelerating rate calorimetry↗

The T2 phase in the Nb-Si-B system studied by ab initio calculations and synchrotron X-ray diffraction

The solid solution based on Nb{sub 5}Si{sub 3} (Cr{sub 5}B{sub 3} structure type, D8{sub l}, tI32, I4/mcm, No140, a=6.5767 A, c=11.8967 A) in the Nb-Si-B system was studied from the structural and thermodynamic point of view both experimentally and by ab initio calculations. Rietveld refinement of powder X-ray synchrotron data allowed to determine the boron to silicon substitution mechanism and the structural parameters. Ab initio calculations of different ordered compounds and selected disordered alloys allowed to obtain in addition to the enthalpy of formation of the solution, substitution mechanism and structural parameters which are in excellent agreement with the experimental data. The stability of the phase is discussed. - Graphial abstract: Valence-charge electron localization function in the z=0 plane of the D8{sub l} structure for the ordered compound Nb{sub 5}SiB{sub 2}. Highlights: Black-Right-Pointing-Pointer Coupling between ab initio data and experimental results from synchrotron powder diffraction. Black-Right-Pointing-Pointer Excellent agreement between the two techniques for the site occupancies and internal coordinates. Black-Right-Pointing-Pointer Explanation of the phase stability up to Nb{sub 5}SiB{sub 2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Peculiarities of thermoelectric half-Heusler phase formation in Gd-Ni-Sb and Lu-Ni-Sb ternary systems

The phase equilibria in the Gd–Ni–Sb and Lu-Ni-Sb ternary systems were studied at 873 K by X-ray and metallographic analyses in the whole concentration range. The interaction of the elements in the Gd–Ni–Sb system results the formation of five ternary compounds at investigated temperature: Gd{sub 5}Ni{sub 2}Sb (Mo{sub 5}SiB{sub 2}-type), Gd{sub 5}NiSb{sub 2} (Yb{sub 5}Sb{sub 3}-type), GdNiSb (MgAgAs-type), Gd{sub 3}Ni{sub 6}Sb{sub 5} (Y{sub 3}Ni{sub 6}Sb{sub 5}-type), and GdNi{sub 0.72}Sb{sub 2} (HfCuSi{sub 2}-type). At investigated temperature the Lu-Ni-Sb system is characterized by formation of the LuNiSb (MgAgAs-type), Lu{sub 5}Ni{sub 2}Sb (Mo{sub 5}SiB{sub 2}-type), and Lu{sub 5}Ni{sub 0.56}Sb{sub 2.44} (Yb{sub 5}Sb{sub 3}-type) compounds. The disordering in the crystal structure of half-Heusler GdNiSb and LuNiSb was revealed by EPMA and studied by means of Rietveld refinement and DFT modeling. The performed electronic structure calculations are in good agreement with electrical transport property studies. - Graphical abstract: Crystal structure model and electron localization function of Lu{sub 5}Ni{sub 2}Sb. Display Omitted - Highlights: • Gd-Ni-Sb and Lu-Ni-Sb phase diagrams were constructed at 873 K. • GdNiSb and LuNiSb are characterized by disordered crystal structure. • Crystal structure optimization with DFT calculations confirmed crystal structure disorder in GdNiSb and LuNiSb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Feasibility of Dose Escalation Positron Emission Tomography-Positive Disease with Intensity-Modulated Radiation Therapy and the Effects on Normal Tissue Structures for Thoracic Malignancies

The pattern of failure is one of the major causes of mortality among thoracic patients. Studies have shown a correlation between local control and dose. Intensity-modulated radiation therapy (IMRT) has resulted in conformal dose distributions while limiting dose to normal tissue. However, thoracic malignancies treated with IMRT to highly conformal doses up to 70 Gy still have been found to fail. Thus, the need for dose escalation through simultaneous integrated boost (SIB) may prove effective in minimizing reoccurrences. For our study, 28 thoracic IMRT plans were reoptimized via dose escalation to the gross tumor volume (GTV) and planning target volume (PTV) of 79.2 Gy and 68.4 Gy, respectively. Reoccurrences in surrounding regions of microscopic disease are rare therefore, dose-escalating regional nodes (outside GTV) were not included. Hence, the need to edit GTV margins was acceptable for our retrospective study. A median dose escalation of approximately 15 Gy (64.8-79.2 Gy) via IMRT using SIB was deemed achievable with minimal percent differences received by critical structures compared with the original treatment plan. The target's mean doses were significantly increased based on p-value analysis, while the normal tissue structures were not significantly changed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy

The purpose of this study was to evaluate helical tomotherapy dosimetry in postmastectomy patients undergoing treatment for chest wall and positive nodal regions with simultaneous integrated boost (SIB) in the scar region using strip bolus. Six postmastectomy patients were scanned with a 5-mm-thick strip bolus covering the scar planning target volume (PTV) plus 2-cm margin. For all 6 cases, the chest wall received a total cumulative dose of 49.3-50.4 Gy with daily fraction size of 1.7-2.0 Gy. Total dose to the scar PTV was prescribed to 58.0-60.2 Gy at 2.0-2.5 Gy per fraction. The supraclavicular PTV and mammary nodal PTV received 1.7-1.9 dose per fraction. Two plans (with and without bolus) were generated for all 6 cases. To generate no-bolus plans, strip bolus was contoured and overrode to air density before planning. The setup reproducibility and delivered dose accuracy were evaluated for all 6 cases. Dose-volume histograms were used to evaluate dose-volume coverage of targets and critical structures. We observed reduced air cavities with the strip bolus setup compared with what we normally see with the full bolus. The thermoluminescence dosimeters (TLD) in vivo dosimetry confirmed accurate dose delivery beneath the bolus. The verification plans performed on the first day megavoltage computed tomography (MVCT) image verified that the daily setup and overall dose delivery was within 2% accuracy compared with the planned dose. The hotspot of the scar PTV in no-bolus plans was 111.4% of the prescribed dose averaged over 6 cases compared with 106.6% with strip bolus. With a strip bolus only covering the postmastectomy scar region, we observed increased dose uniformity to the scar PTV, higher setup reproducibility, and accurate dose delivered beneath the bolus. This study demonstrates the feasibility of using a strip bolus over the scar using tomotherapy for SIB dosimetry in postmastectomy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer

This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV){sub 63} {sub Gy} as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV{sub 70} {sub Gy} and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV{sub 70} {sub Gy} coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Na 4 Fe 1.5 Mn 1.5 (PO 4 ) 2 (P 2 O 7 ): A low-cost and earth-abundant cathode for robust sodium storage

The mixed compounds of phosphates and pyrophosphates are attractive cathodes for sodium-ion batteries (SIBs) owing to their robust open framework structure and superior diffusion dynamics. However, most reported mixed phosphate cathodes generally suffer from low operating potential. Herein, we develop a bimetallic Na 4 Fe 1.5 Mn 1.5 (PO 4 ) 2 (P 2 O 7 )/C-rGO (NFMPP/C-rGO) cathode, which possesses two working plateaus at 2.92 and 3.95 V. The obtained NFMPP/C-rGO demonstrates a stable high capacity of over 120 mAh g −1 at 0.1 C. In-situ XRD characterization discloses a solid solution reaction for the Fe 2+/3+ redox couple and a two-phase reaction for the Mn 2+/3+ redox couple. In conclusion, first-principles calculations reveal the migration of Na + in NFMPP has low barriers. This work provides a new, low-cost, earth-abundant, and stable cathode choice for practical SIBs.

Cathode materials↗

Tailoring conductive networks within hollow carbon nanospheres to host phosphorus for advanced sodium ion batteries

The formidable sustainability challenges in advancing energy storage technologies call for game-changing research in battery designs. The previous pursuing of novel cathode materials with high redox potentials impedes the vast applications due to the simultaneous electrolyte decomposition at high potentials, though they are expected to deliver high specific capacities. Eventually, people start thinking in an opposite way, desirable anode materials with low redox potentials can also own high specific capacities. Among all the promising candidates, phosphorus-based anodes in sodium ion batteries (SIBs) have received considerable attention owing to the low cost and relatively high natural abundance of phosphorus. More importantly, phosphorus can store three sodium atoms and enable a high theoretical capacity of 2596 mAh g -1 , which overwhelms any other SIB anode currently available. However, the poor electronic conductivity and large volume change of phosphorus during cycling severely deteriorate battery performance. The most widely used strategy is to confine phosphorus within well-designed carbon hosts. Here, we thereby introduce a new type of porous hollow carbon with conductive-network interior as phosphorus host, which not only improves the electrical conductivity, but also creates enough interior surface for maximizing phosphorus utilization and shortening the ion's diffusion distance, compared to those conventional hollow carbon hosts. Therefore, the as-prepared red phosphorus-carbon spheres composites (RP/CS) exhibit superior rate performance (similar to 1083 mAh g -1 at 4 A g -1 , similar to 837 mAh g -1 even at 8 A g -1 ) and excellent cycle life (1027 mAh g -1 at 4 A g -1 more than 2000 cycles).

25 ENERGY STORAGE↗