Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Probabilistic simulation of long term behavior in polymer matrix composites

A methodology to compute cumulative probability distribution functions (CDF) of fatigue life for different ratios, r of applied stress to the laminate strength based on first ply failure criteria has been developed and demonstrated. Degradation effects due to long term environmental exposure and mechanical cyclic loads are considered in the simulation process. A unified time-stress dependent multi-factor interaction equation model developed at NASA Lewis Research Center has been used to account for the degradation/aging of material properties due to cyclic loads. Fast probability integration method is used to perform probabilistic simulation of uncertainties. Sensitivity of fatigue life reliability to uncertainties in the primitive random variables are computed and their significance in the reliability based design for maximum life is discussed. The results show that the graphite/epoxy (0/+45/90) deg laminate with ply thickness 0.125 in. has 500,000 cycles life for applied stress to laminate strength ratio of 0.6 and a reliability of 0.999. Also, the fatigue life reliability has been found to be most sensitive to the ply thickness and matrix tensile strength. Tighter quality controls must therefore be enforced on ply thickness and matrix strength in order to achieve high reliability of the structure.

Shah, A. R.↗

Shock Sensitivity of energetic materials

Viscoplastic deformation is examined as the principal source of hot energy. Some shock sensitivity data on a proposed model is explained. A hollow sphere model is used to approximate complex porous matrix of energetic materials. Two pieces of shock sensitivity data are qualitatively compared with results of the proposed model. The first is the p2 tau law. The second is the desensitization of energetic materials by a ramp wave applied stress. An approach to improve the model based on experimental observations is outlined.

Kim, K.↗

Nondestructive construction error detection in large space structures

Continuum modeling of large space structures is extended to the problem of detecting construction errors in large space structures such as the proposed space station. First-order dynamic sensitivity equations for structures involving eigenfrequencies, modal masses, modal stiffnesses, and modal damping are presented. Matrix equations relating changes in element parameters to dynamic sensitivities are summarized. The sensitivity equations for the entire dynamical system are rearranged as a system of algebraic equations with unknowns of stiffness losses at selected locations. The feasibility of the formulation is numerically demonstrated on a simply-supported Euler-Bernouilli beam with simulated construction defects. The method is next extended to large space structures modelled as equivalent continua with simulated construction defects.

Stubbs, Norris↗

Linearized ray-trace analysis

A new, coordinate-free version of the exact ray-trace equations for optical systems consisting of conic reflecting, refracting and reference surfaces is presented. These equations are differentiated to obtain closed-form optical sensitivity dyadics. For computation, the sensitivities are evaluated in a single global coordinate frame and combined in linearized ray-trace matrix difference equations that propagate the rays and the sensitivities from element to element. One purpose of this analysis is to create optical models that can be directly integrated with models of the instrument structure and control systems for dynamic simulation.

Redding, David C.↗

Compressed Expanded Natural Graphite (CENG) Processing for PCM Composites

The use of phase change materials (PCMs) in thermal energy storage applications has received considerable attention in recent decades. Organic PCMs are popular due to their high latent heat of fusion, noncorrosive properties, and relative stability over many charge and discharge cycles. A primary limitation of these materials is their low thermal conductivity. This has led researchers to develop various methods to increase thermal conductivity by seeding PCM with or impregnating them into more conductive materials. One method is to impregnate PCMs into compressed expanded natural graphite (CENG) matrices, which can improve thermal conductivity by a factor of 100. CENG matrices have received particular interest due to their low cost, high porosity, small (nano/micro) pore size, high pore density, high thermal conductivity, and ability to be compressed into many geometries. PCM/CENG matrix composites have been extensively studied; however, the effect that CENG processing has on PCM saturation and the overall matrix thermal conductivity has not been well investigated. This processing includes four major steps including graphite intercalation, thermal shock, compression, and PCM saturation. Intercalation involves soaking graphite flakes in sulfuric and/or nitric acid to intercalate the acids between the graphene layers. The graphite flakes are then subjected to a high-temperature thermal shock, during which the intercalated acid is gasified rapidly, pushing the graphene layers apart, resulting in accordion-shaped graphite "worms". The "worms" are then compacted to a desired bulk density and then soaked with molten PCM until fully saturated. The properties of the produced CENG matrix, and its ability to allow PCM permeation, are sensitive to the processing parameters, namely, the thermal shock temperature and exposure time, as well as the matrix apparent density or porosity. Here, we study the effect of the thermal shock conditions necessary to expand intercalated graphite flakes on PCM saturation and the expanded graphite's thermal conductivity and morphology. We found that the thermal shock temperature exhibits the greatest influence. At greater shock temperatures, SEM images showed that expanded graphite worms exhibited greater density of pores, thus increasing total surface area within the matrices. Increasing thermal shock temperature yielded greater overall PCM saturation, as well as an increased rate of saturation. Improvements in PCM saturation rate and overall saturation are obtained as the shock temperature is increased. Longer exposure to thermal shock also improves initial saturation rates and is beneficial if a shortened impregnation time is needed. Thermal shock conditions did not impact thermal conductivity; however, conductivity was largely affected by matrix porosity. A local maximum in axial thermal conductivity was observed at around 83% porosity, which is similar to that observed in previous studies.

compressed expanded natural graphite↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Constraints on anomalous Higgs boson couplings from its production and decay using the WW channel in proton–proton collisions at $\sqrt{s} = 13~\text {TeV}$

A study of the anomalous couplings of the Higgs boson to vector bosons, including ${\textit{CP}}$-violation effects, has been conducted using its production and decay in the WW channel. This analysis is performed on proton–proton collision data collected with the CMS detector at the CERN LHC during 2016–2018 at a center-of-mass energy of 13 TeV, and corresponds to an integrated luminosity of 138$\,\text {fb}^{-1}$. The different-flavor dilepton $({\textrm{e}} {{\upmu }})$ final state is analyzed, with dedicated categories targeting gluon fusion, electroweak vector boson fusion, and associated production with a W or Z boson. Kinematic information from associated jets is combined using matrix element techniques to increase the sensitivity to anomalous effects at the production vertex. A simultaneous measurement of four Higgs boson couplings to electroweak vector bosons is performed in the framework of a standard model effective field theory. All measurements are consistent with the expectations for the standard model Higgs boson and constraints are set on the fractional contribution of the anomalous couplings to the Higgs boson production cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deformation of a metal-matrix tensile coupon with a central slot - An experimental study

A metal-matrix specimen was investigated using high-sensitivity moire interferometry. In-plane displacement fields were analyzed at various load levels from 15 to 95 percent of the failure load. Normal and shear strains were determined from displacement gradients. Highly localized plastic slip zones occured in the ductile aluminum matrix tangent to the ends of the slot. Shear strains in the slip zone were an order of magnitude greater than the largest normal strains in the specimen. The shear-strain concentration factor rose dramatically with the onset of plastic slip and continued to rise gradually with load to 95 percent of the failure load. Upon unloading, shear strains in the slip zone remained precariously high.

Post, Daniel↗

Hypergravity Stimulates Osteoblast Proliferation Via Matrix-Integrin-Signaling Pathways

Extensive characterizations of the physiologic consequences of microgravity and gravity indicate that lack of weight-bearing may cause tissue atrophy through cellular and subcellular level mechanisms. We hypothesize that gravity is needed for the efficient transduction of cell growth and survival signals from the extra-cellular matrix (ECM) in mechanosensitive tissues. Recent work from our laboratory and from others shows that an increase of gravity increases bone cell growth and survival. We found that 50-g hypergravity stimulation increased osteoblast proliferation for cells grown on Collagen Type I and Fibronectin, but not on Laminin or uncoated plastic. This may be a tissue-specific response, because 50-g hypergravity stimulation caused no increase in proliferation for primary rat fibroblasts. These results combined with RT-PCR for all possible integrins indicate that beta1 integrin subunit may be involved. The osteoblast proliferation response on Collagen Type I was greater at 25-g than at 10-g or 50-g; 24-h duration of hypergravity was necessary to see an increase in proliferation. Survival was enhanced during hypergravity stimulation by the presence of matrix. Flow cytometry analysis indicated that cell cycle may be altered; BrdU incorporation in proliferating cells showed an increase in the number of actively dividing cells from about 60% at 1-g to over 90% at 25-g. To further investigate the molecular components involved, we applied fluorescence labeling of cytoskeletal and signaling molecules to cells after 2 to 30 minutes of hypergravity stimulation. While structural components did not appear to be altered, phosphorylation increased, indicating that signaling pathways may be activated. These data indicate that gravity mechanostimulation of osteoblast proliferation involves specific matrix-integrin signaling pathways which are sensitive to duration and g-level.

Vercoutere, W.↗

Well proppants

Deployable smart acoustic resonance particles have dense cores, compliant matrixes surrounding the cores and stiff outer shells surrounding the matrixes. The particles have mechanical stress sensitivities that provide unique band gap shifts when compressed. Groups of similar particles with similar stress sensitivities and similar band gap shifts are added at different times to hydraulic fluids, as circulated through wells with the fluid and pushed into fractures. A plural, sonic monopole well logging tool is lowered into the well to determine locations and depth of fractures and local pressures by distinct resonance of individual groups.

Pollock, Jacob↗

Implementation of Windowed Multipole into MCNP6.3

This work details the implementation of the Windowed MultiPole(WMP) method of generating cross sections into the monte carlo code MCNP6.3, the verification and validation performed, and potential future improvements to be implemented. Further, this work contextualizes WMP within the broader changes to how nuclear data is stored, iterated upon, and used that have been developing over the past decade.

97 MATHEMATICS AND COMPUTING↗

Integrated structural-aerodynamic design optimization

This paper focuses on the processes of simultaneous aerodynamic and structural wing design as a prototype for design integration, with emphasis on the major difficulty associated with multidisciplinary design optimization processes, their enormous computational costs. Methods are presented for reducing this computational burden through the development of efficient methods for cross-sensitivity calculations and the implementation of approximate optimization procedures. Utilizing a modular sensitivity analysis approach, it is shown that the sensitivities can be computed without the expensive calculation of the derivatives of the aerodynamic influence coefficient matrix, and the derivatives of the structural flexibility matrix. The same process is used to efficiently evaluate the sensitivities of the wing divergence constraint, which should be particularly useful, not only in problems of complete integrated aircraft design, but also in aeroelastic tailoring applications.

Haftka, R. T.↗

Polymer-Based Thermally Stable Chemiresistive Sensor for Real-Time Monitoring of NO 2 Gas Emission

Here, we present a thermally stable, mechanically compliant, and sensitive polymer-based NO 2 gas sensor design. Interconnected nanoscale morphology driven from spinodal decomposition between conjugated polymers tethered with polar side chains and thermally stable matrix polymers offers judicious design of NO 2 -sensitive and thermally tolerant thin films. The resulting chemiresitive sensors exhibit stable NO 2 sensing even at 170 °C over 6 h. Controlling the density of polar side chains along conjugated polymer backbone enables optimal design for coupling high NO 2 sensitivity, selectivity, and thermal stability of polymer sensors. Lastly, thermally stable films are used to implement chemiresistive sensors onto flexible and heat-resistant substrates and demonstrate a reliable gas sensing response even after 500 bending cycles at 170 °C. Such unprecedented sensor performance as well as environmental stability are promising for real-time monitoring of gas emission from vehicles and industrial chemical processes.

47 OTHER INSTRUMENTATION↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visual optimization of DCT quantization matrices for individual images

Many image compression standards (JPEG, MPEG, H.261) are based on the Discrete Cosine Transform (DCT). However, these standards do not specify the actual DCT quantization matrix. We have previously provided mathematical formulae to compute a perceptually lossless quantization matrix. Here I show how to compute a matrix that is optimized for a particular image. The method treats each DCT coefficient as an approximation to the local response of a visual 'channel'. For a given quantization matrix, the DCT quantization errors are adjusted by contrast sensitivity, light adaptation, and contrast masking, and are pooled non-linearly over the blocks of the image. This yields an 8x8 'perceptual error matrix'. A second non-linear pooling over the perceptual error matrix yields total perceptual error. With this model we may estimate the quantization matrix for a particular image that yields minimum bit rate for a given total perceptual error, or minimum perceptual error for a given bit rate. Custom matrices for a number of images show clear improvement over image-independent matrices. Custom matrices are compatible with the JPEG standard, which requires transmission of the quantization matrix.

Watson, Andrew B.↗

Thermomechanical Fatigue Behavior of Three Cfcc's

The thermomechanical fatigue (TMF) behavior of three continuous-fiber ceramic composites (CFCC's) was examined. The three matrices consisted of two different glass-ceramics and silicon carbide, respectively. The matrices of some of the specimens with the silicon carbide matrix were enhanced to improve oxidation resistance. All three were reinforced with Nicalon fibers with various fiber architectures. The thermoelastic properties of the matrix relative to the fibers, the elastic moduli and coefficients of thermal expansion (CTE), were different in each composite, providing a comparison of the effects of these critical properties. The specimens were tested under in-phase (IP) and out-of-phase (OP) cyclic loadings with respect to thermal cycling between 600 C and 1100 C. One of the glass-ceramic composites had greatly increased TMF lives compared to the other glass-ceramic matrix composites. This was probably caused by the reversal of the CTE mismatch between the fibers and the matrices and caused by the different oxidation resistances of the composites. For the same TMF lives a cross-ply reinforced composite had a maximum cyclic stress half as great, as that of unidirectionally reinforced composite. This indicated that the (0 deg) ply fibers had a strong influence of TMF life. Both the glass ceramic matrix composites had shallow-slope stress-life plots that indicated sensitivity to damage and therefore low damage tolerance. The composites with an unenhanced silicon carbide matrix experienced the shortest TMF lives of all the CFCC's tested. However, the enhanced composite had the longest. Also, the enhanced composite demonstrated the best damage tolerance as evidenced by a stress-life curve that curves sharply upward to the left. In all the composites, out-of-phase cyclic loading was worse than in-phase cyclic loadings despite the CTE mismatch between fiber and matrix. A damage investigation and a preliminary analysis of the stresses in the fibers and matrices taking into account their respective thermoelastic properties provided insight into the relative behavior of the glass-ceramic matrix composites under IP and OP TMF.

Worthem, Dennis W.↗

Determining g A / g V with High-Resolution Spectral Measurements Using a LiInSe 2 Bolometer

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g A /g V ), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. Here we present measurements performed on a high-resolution LiInSe 2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115 In . The value of g A /g V is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g A /g V at >5 σ with a model-dependent quenching factor of 0.655 ± 0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the 115 In half-life to be [5.18 ± 0.06(stat) $^{+0.005}_{- 0.015}$(sys)] x 10 14 yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-β decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νββ sensitivity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Resistivity of Carbon-Carbon Composites Halved

Carbon-carbon composites have become the material of choice for applications requiring strength and stiffness at very high temperatures (above 2000 C). These composites comprise carbon or graphite fibers embedded in a carbonized or graphitized matrix. In some applications, such as shielding sensitive electronics in very high temperature environments, the performance of these materials would be improved by lowering their electrical resistivity. One method to lower the resistivity of the composites is to lower the resistivity of the graphite fibers, and a proven method to accomplish that is intercalation. Intercalation is the insertion of guest atoms or molecules into a host lattice. In this study the host fibers were highly graphitic pitch-based graphite fibers, or vapor-grown carbon fibers (VGCF), and the intercalate was bromine. Intercalation compounds of graphite are generally thought of as being only metastable, but it has been shown that the residual bromine graphite fiber intercalation compound is remarkably stable, resisting decomposition even at temperatures at least as high as 1000 C. The focus of this work was to fabricate composite preforms, determine whether the fibers they were made from were still intercalated with bromine after processing, and determine the effect on composite resistivity. It was not expected that the resistivity would be lowered as dramatically as with graphite polymer composites because the matrix itself would be much more conductive, but it was hoped that the gains would be substantial enough to warrant its use in high-performance applications. In a collaborative effort supporting a Space Act Agreement between the NASA Glenn Research Center and Applied Sciences, Inc. (Cedarville, OH), laminar preforms were fabricated with pristine and bromine-intercalated pitch-based fibers (P100 and P100-Br) and VGCF (Pyro I and Pyro I-Br). The green preforms were carbonized at 1000 C and then heat treated to 3000 C. To determine whether the fibers in the samples were still intercalated after composite fabrication, they were subjected to X-ray diffraction. The composites containing intercalated graphite fibers showed much higher background scatter than that of pristine fibers, indicating the presence of bromine in the samples. More importantly, faint features indicative of intercalation were visible in the diffraction pattern, showing that the fibers were still intercalated.

Gaier, James R.↗