Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Sensitive photodetection below silicon bandgap using quinoid-capped organic semiconductors

High-sensitivity organic photodetectors (OPDs) with strong near-infrared (NIR) photoresponse have attracted enormous attention due to potential applications in emerging technologies. However, few organic semiconductors have been reported with photoelectric response beyond ~1.1 μm, the detection limit of silicon detectors. Here, we extend the absorption of organic small-molecule semiconductors to below silicon bandgap, and even to 0.77 eV, through introducing the newly designed quinoid-terminals with high Mulliken-electronegativity (5.62 eV). The fabricated photodiode-type NIR OPDs exhibit detectivity (D*) over 10 12 Jones in 0.41 to 1.2 μm under zero bias with a maximum of 2.9 × 10 12 Jones at 1.02 μm, which is the highest D* for reported OPDs in photovoltaic-mode with response spectra beyond 1.1 μm. The high D* in 0.9 to 1.2 μm is comparable to those of commercial InGaAs photodetectors, despite the detection limit of our OPDs is shorter than InGaAs (~1.7 μm). A spectrometer prototype with a wide measurable region (0.4 to 1.25 μm) and NIR imaging under 1.2-μm illumination are demonstrated successfully in OPDs.

36 MATERIALS SCIENCE↗

Directional detection of dark matter using solid-state quantum sensing

Next-generation dark matter (DM) detectors searching for weakly interacting massive particles (WIMPs) will be sensitive to coherent scattering from solar neutrinos, demanding an efficient background-signal discrimination tool. Directional detectors improve sensitivity to WIMP DM despite the irreducible neutrino background. Wide-bandgap semiconductors offer a path to directional detection in a high-density target material. A detector of this type operates in a hybrid mode. Here, the WIMP or neutrino-induced nuclear recoil is detected using real-time charge, phonon, or photon collection. The directional signal, however, is imprinted as a durable sub-micron damage track in the lattice structure. This directional signal can be read out by a variety of atomic physics techniques, from point defect quantum sensing to x-ray microscopy. In this Review, we present the detector principle as well as the status of the experimental techniques required for directional readout of nuclear recoil tracks. Specifically, we focus on diamond as a target material; it is both a leading platform for emerging quantum technologies and a promising component of next-generation semiconductor electronics. Based on the development and demonstration of directional readout in diamond over the next decade, a future WIMP detector will leverage or motivate advances in multiple disciplines toward precision dark matter and neutrino physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Capacitance–voltage modeling of mid-wavelength infrared nBn detectors

Capacitance–voltage measurements are a powerful technique to determine doping profiles of semiconductor pn junctions and Schottky barrier diodes. The measurements were recently extended to III-V-based mid-wavelength nBn infrared detectors, and absorber doping densities have been extracted using the widely accepted Schottky approximation, where the potential drop across the device is assumed to be across the depleting absorber layer. However, this approach is limited to when the absorber region of the nBn is under high reverse bias and thus is only able to extract the absorber region doping profile. Here, we introduce a semi-analytical model that is capable of extracting barrier dopant polarity, doping concentration, and thickness, as well as contact and absorber layer doping concentrations, all from a capacitance–voltage measurement. Rather than solely considering the potential drop across the depleting layers, it considers the potential drop across the accumulating layer as well. This negative charge accumulation occurs for the contact and absorber layers in the case of reverse and forward biases, respectively. This allows for a single model to be applied to a capacitance–voltage curve at forward and reverse biases and it can provide regions of bias where the absorber transitions from depletion to accumulation. We compare the agreement of the semianalytical model with modeling results from commercially available finite element method software and experimental capacitance–voltage data. Finally, we show that the method is consistent with the Schottky approximation of extracting absorber doping densities at high reverse bias and discuss the model's limitations.

Physics↗

Plasmonics-enhanced photoconductive terahertz detector pumped by Ytterbium-doped fiber laser

We present a photoconductive terahertz detector operating at the 1 µm wavelength range at which high-power and compact Ytterbium-doped femtosecond fiber lasers are available. The detector utilizes an array of plasmonic nanoantennas to provide sub-picosecond transit time for the majority of photo-generated carriers to enable high-sensitivity terahertz detection without using a short-carrier-lifetime substrate. By using a high-mobility semiconductor substrate and preventing photocarrier recombination, the presented detector offers significantly higher sensitivity levels compared with previously demonstrated broadband photoconductive terahertz detectors operating at the 1 µm wavelength range. We demonstrate pulsed terahertz detection over a 4 THz bandwidth with a record-high signal-to-noise ratio of 95 dB at an average terahertz radiation power of 6.8 µW, when using an optical pump power of 30 mW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel Perovskite Semiconductors for the Detection of Special Nuclear Material

Special nuclear material detection using portable, highly efficient detectors is of paramount importance to national security and environmental monitoring. Current neutron detectors, including gas proportional counters and scintillators, are not suitable for discrete or portable monitoring due to size, weight, and power limitations. For example, 3 He gas proportional detectors have significant drawbacks, including long absorption lengths, high voltage requirements, and dependence on the availability of 3 He. The goal of this project is to synthesize a novel, boron-based perovskite semiconductor crystals to create a more efficient and more portable neutron detector. This innovative material will lead to a significant decrease in power and size requirements with higher operating temperatures than other traditional solid-state detectors. Directly incorporating 10 B eliminates the need for a conversion layer and leads to high neutron absorption coefficients. In this seedling project, we used inverse temperature crystallization with boron precursors to create CH 3 NH 3 PbI 3-x (BF 4 ) x . The crystals were analyzed with X-ray diffraction, but the results were inconclusive. Future work will focus on tailoring the solution growth and selecting appropriate solvents and precursors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Metrics In Situ Aging Detector for SiC Power MOSFET Modules with Full Driver-Integration Capability

In this paper, the concept and prototype of an aging detector for silicon carbide (SiC) power metal oxide semiconductor field effect transistor (MOSFET) are proposed and described. It leverages the resonant peak values of gate-source voltage at different instants during the switching transients to decode the change of multiple aging indicators, such as the increases of on-state resistance and threshold voltage. Modeling-based analysis is conducted to support the idea. The detector can be fully integrated into gate drivers without any additional connection to the power stage and is functional during normal power stage operation. A prototype unit was built, and preliminary tests were conducted to validate the idea and the practicality of the detector.

aging↗

High Performance Pd/4H-SiC Epitaxial Schottky Barrier Radiation Detectors for Harsh Environment Applications

Although many refractory metals have been investigated as the choice of contact metal in 4H-SiC devices, palladium (Pd) as a Schottky barrier contact for 4H-SiC radiation detectors for harsh environment applications has not been investigated adequately. Pd is a refractory metal with high material weight-to-thickness ratio and a work function as high as nickel, one of the conventional metal contacts for high performing 4H-SiC Schottky barrier detectors (SBDs). In this article, Pd/4H-SiC epitaxial SBDs have been demonstrated for the first time as a superior self-biased (0 V applied bias) radiation detector when compared to benchmark Ni/4H-SiC SBDs. The Pd/4H-SiC SBD radiation detectors showed a very high energy resolution of 1.9% and 0.49% under self- and optimized bias, respectively, for 5486 keV alpha particles. The SBDs demonstrated a built-in voltage (V bi ) of 2.03 V and a hole diffusion length (L d ) of 30.8 µm. Such high V bi and L d led to an excellent charge collection efficiency of 76% in the self-biased mode. Capacitance mode deep level transient spectroscopy (DLTS) results revealed that the “lifetime-killer” Z 1/2 trap centers were present in the 4H-SiC epilayer. Another deep level trap was located at 1.09 eV below the conduction band minimum and resembles the EH5 trap with a concentration of 1.98 × 10 11 cm –3 and capture cross-section 1.7 × 10 –17 cm –2 ; however, the detector performance was found to be limited by charge trapping in the Z 1/2 center. The results presented in this article revealed the unexplored potential of a wide bandgap semiconductor, SiC, as high-efficiency self-biased radiation detectors. Such high performance self-biased radiation detectors are poised to address the longstanding problem of designing self-powered sensor devices for harsh environment applications e.g., advanced nuclear reactors and deep space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation hard Ga 2 O 3 detectors for high energy physics

In this project, we explore the use of ultra-wide bandgap Ga 2 O 3 materials for fabricating next-generation radiation hard solid-state detectors for high energy physics (HEP) applications. As an emerging semiconductor, Ga 2 O 3 has ultra-wide bandgap (4.5-4.9 eV), high breakdown electric field (8 MV/cm) and much lower production cost compared with radiation hard diamond detectors, all of which make Ga 2 O 3 a great candidate material working in harsh radiation environment of future HEP experiments. The recent breakthrough of growth technologies of Ga 2 O 3 significantly improves the availability of large area single crystalline Ga 2 O 3 . We focus on an early proof-of-principle demonstration of Ga 2 O 3 detectors and conduct comprehensive material and detector characterization to evaluate the potential of the emerging Ga 2 O 3 as a new radiation-hard detector material. Our endeavors directly support the instrumentation development and update need of HEP experiments and fits very well into the DOE HEP “Detector R&D” research subprogram.

36 MATERIALS SCIENCE↗

Study of CdZnTeSe Gamma-Ray Detector under Various Bias Voltages

Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of 241 Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Impact of dopant-induced band tails on optical spectra, charge carrier transport, and dynamics in single-crystal CdTe

Abstract Cadmium telluride (CdTe) semiconductors are used in thin-film photovoltaics, detectors, and other optoelectronic applications. For all technologies, higher efficiency and sensitivity are achieved with reduced charge carrier recombination. In this study, we use state-of-the-art CdTe single crystals and electro-optical measurements to develop a detailed understanding of recombination rate dependence on excitation and temperature in CdTe. We study recombination and carrier dynamics in high-resistivity (undoped) and arsenic (As)-doped CdTe by employing absorption, the Hall effect, time-resolved photoluminescence, and pump-probe in the 80–600 K temperature range. We report extraordinarily long lifetimes (30 µs) at low temperatures in bulk undoped CdTe. Temperature dependencies of carrier density and mobility reveal ionization of the main acceptors and donors as well as dominant scattering by ionized impurities. We also distinguish different recombination defects. In particular, shallow As Te and deep V Cd −As Cd acceptors were responsible for p-type conductivity. AX donors were responsible for electron capture, while nonradiative recombination centers (V Cd −As Te , As 2 precipitates), and native defects (V Cd −Te Cd ) were found to be dominant in p-type and n-type CdTe, respectively. Bimolecular and surface recombination rate temperature dependencies were also revealed, with bimolecular coefficient T −3/2 temperature dependence and 170 meV effective surface barrier, leading to an increase in surface recombination velocity at high temperatures and excitations. The results of this study allowed us to conclude that enhanced crucible rotation growth of As-doped CdTe is advantageous to As activation, leading to longer lifetimes and larger mobilities and open-circuit voltages due to lower absorption and trapping.

36 MATERIALS SCIENCE↗

Probing the surface oxidation process in hexagonal boron nitride epilayers

Thermal neutron detectors based on hexagonal boron nitride ( h -BN) epilayers have demonstrated a record high efficiency among solid-state detectors at 58%. It was found that the performance of h -BN detectors is profoundly influenced by charge recombination at the surfaces. The dynamic process of surface oxidation in h -BN epilayers has been probed by x-ray photoelectron spectroscopy. The spectra of high-resolution (0.1 eV) scans indicated that the linewidth of the B 1s peak at 190.6 eV increased and the peak intensity decreased with an increase in exposure time in-air (t air ). The main B 1s peak at 190.6 eV evolved into multiple peaks at a higher binding energy position due to oxygen impurities tending to occupy nitrogen sites and form the B–O bond. Time constants of the oxidation process have been determined, revealing that the formation process of the B–O bond is very fast and within minutes in h -BN. The results suggest that reducing nitrogen vacancy generation during growth and employing surface treatment techniques would further improve the performance of h -BN devices.

2D materials↗

Charge collection in h -BN neutron detectors at elevated temperatures

Many of the neutron detector applications are in the environments with harsh conditions such as high temperatures. We report here the measurements of charge collection parameters of hexagonal boron nitride (h-BN) detectors at elevated temperatures, including the electron mobility-lifetime product (μτ) and surface recombination field (s/μ). It was found that μτ is increased, while s/μ is decreased as temperature increases. The temperature dependence of the surface recombination field (s/μ) revealed that electrons trapped in the surface states tend to thermally activate to the bulk region at higher temperatures with an activation energy of about 0.22 eV, leading to a reduction in the density of the charged surface states at elevated temperatures. Consequently, the charge collection efficiency is enhanced at elevated temperatures due to a reduced surface recombination field and increased electron mobility-lifetime product. The results suggested that h-BN neutron detectors are favorable for high temperature operation.

47 OTHER INSTRUMENTATION↗

Adversarial autoencoder ensemble for fast and probabilistic reconstructions of few-shot photon correlation functions for solid-state quantum emitters

Second-order photon correlation measurements [g (2) (τ) functions] are widely used to classify single-photon emission purity in quantum emitters or to measure the multiexciton quantum yield of emitters that can simultaneously host multiple excitations – such as quantum dots – by evaluating the value of g (2) (τ = 0). Accumulating enough photons to accurately calculate this value is time consuming and could be accelerated by fitting of few-shot photon correlations. Here, we develop an uncertainty-aware, deep adversarial autoencoder ensemble (AAE) that reconstructs noise-free g (2) (τ) functions from noise-dominated, few-shot inputs. The model is trained with simulated g (2) (τ) functions that are facilely generated by Poisson sampling time bins. The AAE reconstructions are performed orders-of-magnitude faster, with reconstruction errors and estimates of g (2) (τ = 0) that are lower in variance and similar in accuracy compared to Maximum likelihood estimation and Levenberg-Marquardt least-squares fitting approaches, for simulated and experimentally measured few-shot g (2) (τ) functions (~100 two-photon events) of InP/ZnS/ZnSe and CdS/CdSe/CdS quantum dots. The deep-ensemble model comprises eight individual autoencoders, allowing for probabilistic reconstructions of noise-free g (2) (τ) functions, and we show that the predicted variance scales inversely with number of shots, with comparable uncertainties to computationally intensive Markov chain Monte Carlo sampling. Furthermore, this work demonstrates the advantage of machine learning models to perform uncertainty-aware, fast, and accurate reconstructions of simple Poisson-distributed photon correlation functions, allowing for on-the-fly reconstructions and accelerated materials characterization of solid-state quantum emitters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gamma-ray Spectra from a 3x3 CsPbBr 3 Array

CsPbBr 3 is a promising semiconductor material for X- and γ-ray detection at room temperature due to a wide bandgap of 2.3eV, high stopping power, and relatively high mobility-lifetime products of electrons and holes, and the capability of growing large crystals. In this paper we report on fabrication and testing of a 3.8 mm thick, 3 X 3 array with 1.2 mm pitch. Raw 137 Cs spectra were acquired with applied bias of 400 V, 500 V, and 600 V. Energy resolution of between 2 and 3 % FWHM at 662 keV was obtained from most pixels without any correction at room temperature. After 15 days under continuous bias at 600 V, no polarization effects were observed.

36 MATERIALS SCIENCE↗

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Anisotropy in Thermal Conductivity of Ga2O3 under Irradiation: Ab-initio Investigations

Ga2O3 is a wide-bandgap semiconducting material known for its high breakdown electric field and thermal stability. Its various crystalline forms have shown great potential in power electronics, optoelectronics, and high-temperature applications. Specifically, ß-Ga2O3 has been recognized for its suitability in neutron and gamma radiation detection, making it ideal for sensor and detector applications [1]. Notably, ß-Ga2O3 exhibits anisotropic thermal conductivity, meaning that the magnitude of thermal conductivity varies with the crystallographic direction [2]. Under neutron irradiation, Ga2O3 undergoes a significant phenomenon, resulting in the formation of Helium bubbles within its crystalline matrix. The presence of Helium in Ga2O3 has been found to influence the material's anisotropic thermal conductivity. In this study, the objectives were twofold: firstly, to employ Density Functional Theory (DFT) to determine the most probable sites of Helium occupation in ß-Ga2O3, and secondly, to investigate the anisotropic variation in thermal conductivity when Helium is present in the crystalline matrix of ß-Ga2O3. These ab-initio DFT studies provide crucial insights into understanding the behavior of Helium in Ga2O3 and its impact on thermal conductivity, which can contribute to further advancements in sensor and detector applications based on this wide-bandgap semiconductor.

36 MATERIALS SCIENCE↗