Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Multiple dye interactions in plastic scintillators: Effects on pulse shape discrimination

The scintillation process in plastic scintillators has been studied with mixed systems containing high concentrations of multiple fluorescence dyes. It has been shown that the triplet–triplet interaction phenomena leading to the production of delayed light and pulse shape discrimination (PSD) can vary depending on the triplet energies of the interacting dyes. At small differences between the first excited triplet state energies, found to be below 0.1 eV, a pair of interacting dyes of different molecular species can be involved in heterogeneous excitation migration and triplet–triplet annihilation that result in the enhancement of delayed light and PSD, due to the engagement of both dyes in the process. At differences above 0.27 eV, excitation trapping on the lower energy triplet molecules leads to conditions when triplet–triplet migration and annihilation can proceed only homogeneously between molecules of the same species. The results explain the different effects produced by the selection of fluorescent dyes in previously reported PSD systems containing one primary and one secondary dyes. They also demonstrate a non-traditional approach to the design of new plastic scintillators with multiple dyes that, at improved scintillation and PSD performance, may simplify the production process.

36 MATERIALS SCIENCE↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Mixed Material Scintillator Systems (Quarterly Report FY20Q3)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed Material Scintillator Systems (NA-22 Project End Report)

This project aimed to invent, model, and prototype architected multimaterial scintillator systems (AMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (AM, i.e. 3D printing) of scintillator, a currently emerging application of additive manufacture technology. AMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising AMSS designs, this project enabled a new class of detectors to meet DNN’s mission needs for SNM detection.

36 MATERIALS SCIENCE↗

Mixed Material Scintillator Systems Position Reconstruction Modelling Report

A Mixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Event Reconstruction for Water-based Liquid Scintillator Detectors

Water Cherenkov and liquid scintillator detectors represent two complementary approaches in neutrino physics. Water Cherenkov detectors provide particle track direction and particle identification (PID) through Cherenkov ring topology, while liquid scintillator detectors offer higher light yield and lower energy thresholds. Water-based liquid scintillator (WbLS) is designed to combine the advantages of both technologies. However, the simultaneous detection of Cherenkov and scintillation light by photosensors introduces significant challenges for event reconstruction. This poster presents event reconstruction studies for WbLS detectors. A likelihood-based reconstruction framework, fiTQun, has been successfully used in Super-Kamiokande to reconstruct water Cherenkov events in cylindrical detectors. We extend and improve this framework to demonstrate event reconstruction in WbLS detectors, enabling the concurrent reconstruction of particle energy, PID, vertex, and direction. The results demonstrate competitive performance in energy resolution, PID separation, and vertex and direction reconstruction, highlighting the strong potential of WbLS for next-generation neutrino experiments.

Xie, Zhenxiong [Minnesota U.] (ORCID:0009000301442↗

Defect-resistant plastic scintillation radiation detector compositions and fabrication methods

Scintillating plastics resistant to crazing and fogging, methods of making and using the same are disclosed. The scintillating plastics include: one or more primary polymers present in an amount ranging from about 40 wt % to about 95 wt %; one or more secondary polymers present in an amount ranging from about 1 wt % to about 60 wt %; and one or more fluors present in an amount ranging from about 0.1 wt % to about 50 wt %. Methods of making such plastics include: creating a homogenous mixture of precursor materials including primary polymer, secondary polymer, and fluor in the amounts set forth above; and polymerizing the homogenous mixture. Methods of using such plastics include: exposing the scintillating plastic to one or more extreme environmental conditions for a predetermined amount of time without generating crazing or fogging within the scintillating plastic. Various additional features and specific embodiments of these inventive concepts are also disclosed.

36 MATERIALS SCIENCE↗

Tl+-based and mixed halide A3B2X9-type scintillators

Inorganic halides (e.g., inorganic halide scintillators) of the general formula A3B2X9, including inorganic halides comprising thallium monovalent cations and/or combinations of different halides, are described. Radiation detectors including the inorganic halide scintillators and methods of using the detectors to detect high energy radiation are also described. In some cases, the scintillators can include a gadolinium cation, a boron cation, a lithium cation, a chloride ion, or combinations thereof and the scintillator can be used to detect neutrons.

Rutstrom, Daniel↗

System and method for neutron and gamma radiation detection using non-homogeneous material scintillator

A scintillator system is disclosed for detecting incoming radiation. The system makes use of a scintillator structure having first and second dissimilar materials. The first dissimilar material emits a first color of light and the second dissimilar material emits a second color of light different from the first color of light. Either one, or both, of the first or second colors of light are emitted in response to receipt of the incoming radiation. A plurality of light detectors is disposed in proximity to the scintillator structure for detecting the first and second different colors of light and generating output signals in response thereto. A detector electronics subsystem is responsive to the output signals and provides an indication of colors emitted by the scintillator structure to infer at least one property of the incoming radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Defect-resistant plastic scintillators with aliphatic additives

A plastic scintillator includes a polymer matrix, an aliphatic additive present in the polymer matrix in an effective amount to impart fog resistance to the plastic scintillator, and at least one fluorescent dye in the polymer matrix, the dye being effective to provide scintillation upon exposure to radiation. The effective amount of the aliphatic additive is in a range of greater than 0 weight percent up to 5 weight percent relative to the total weight of the plastic scintillator. Moreover, the aliphatic additive has a structure comprising up to 300 repeat units.

Mabe, Andrew Neil↗