Re-establishment of Sandia National Labs super-critical carbon dioxide testing autoclave capability for exposure of metal alloys and polymers (Level 4 Milestone Report)
The sCO 2 system located in 916/160A, Sandia National Laboratories, CA, was constructed in 2014, for testing of materials in the presence of supercritical carbon dioxide (sCO 2 ) at high pressures (up to 3500 psi) and temperatures (up to 650°C). The basic design of the system consists of a thermally insulated IN625 autoclave, a high-pressure supercritical CO 2 compressor, autoclave heaters, temperature controllers, gas manifold, and temperature and pressure diagnostics. This system was modified in 2016 (sCO 2 compressor was removed) to enable corrosion studies with metal alloys in gaseous CO 2 at lower pressure (up to 300 psi) at 500°C. The capability was not used much afterwards until 2020, when preliminary tests using this capability (again without the supercritical CO 2 compressor) involved the exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours in gaseous CO 2 . Using this capability, we finished experiments with low pressure (450 psi/ 3 MPa), high temperature (650°C) exposure of fatigue and tensile specimens of HN 230 and 800H alloys to CO 2 gas for 168 hours. The data from these experiments will be compared to that gathered from experiments performed in 2020 using the tube furnace and presented in a future report. It is to be noted that the tube furnace experiments ran 500-1500 hours, unlike the 168 hours of exposure in the recent experiment. This can help validate the use of the sCO 2 autoclave for both CO 2 and sCO 2 experiments.