Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Preparation Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Solar System Samples for Research, Education, and Public Outreach

In the next two years, during the NASA Year of the Solar System, spacecraft from NASA and our international partners will; encounter a comet, orbit asteroid 4 Vesta, continue to explore Mars with rovers, and launch robotic explorers to the Moon and Mars. We have pieces of all these worlds in our laboratories, and their continued study provides incredibly valuable "ground truth" to complement space exploration missions. Extensive information about these unique materials, as well as actual lunar samples and meteorites, are available for display and education. The Johnson Space Center (JSC) has the unique responsibility to curate NASA's extraterrestrial samples from past and future missions. Curation includes documentation, preservation, preparation, and distribution of samples for research, education, and public outreach.

Allen, J.↗

Repair and Utilization of the Kratos XSAM 800 X-Ray Photoelectron Spectrometer (XPS)

The objectives for this summer faculty fellowship were first to repair the Kratos XSAM 800 X-ray Photoelectron Spectrometer (XPS) and then to utilize the instrument to participate in ongoing research projects at KSC and in the researcher's own laboratory at UCF. The first 6 weeks were used in repairing the instrument. Working both alone and with the Kratos service engineer, a number of hardware problems, largely associated with the sample stage control system, were corrected. Defective parts were identified and fixed in the computer driver boards, the stage power supply, and the driver interface. The power supply was completely replaced. After four weeks of work, the instrument was functional. This occurred on a Wednesday. The following Friday the instrument had to be completely shut down because the power to the O & C Building was to be turned off. The instrument was properly secured. On Monday, the instrument was powered up and the original problems returned. After another 2 weeks of work, a software problem was identified. This problem caused the computer to use a defective port for the sample stage control. It was circumvented by rewriting the startup routine. The final 3 weeks of the fellowship were spent using the XPS to analyze samples being studied in the Langley materials project (Martha Williams) and a catalyst project (Dr. Orlando Melendez). During this time, several sample analysis requests from other groups at KSC also came in and those samples were run as well. The summer faculty fellowship also allowed many contacts to be made. After meeting with the sensors group, two projects were identified for collaboration and white papers are being prepared. One project aims to develop small, very sensitive hydrogen detectors and the other to develop a broad area, easily monitored, zero power consumption hydrogen detector. In addition to the work mentioned above, the XPS was utilized in a study underway in Dr. Hampton's laboratory at UCF.

Hampton, Michael D.↗

Rationale for Mars Rover/Sampler Return mission

A Mars Rover/Sample Return (MRSR) mission is currently being studied for the late 1990's. The objectives of the mission are to better understand the origin and evolution of Mars, to search for evidence of former life, and to improve the knowledge of the Martian environment in preparation for subsequent human exploration. Having formed in a different part of the Solar System from Earth, Mars will provide clues that will better enable the discrimination between conflicting theories of Solar System formations. Mars is also a natural laboratory on which a wide range of geologic and meteorological processes have operated under conditions very different from those on Earth. Samples are needed so that the full range of analytical techniques available here on Earth can be applied to the study of these issues. The rover provides the mobility needed to access different materials, and can be equipped with an analytical capability so that the planet can be sampled intelligently. The rover will also provide the means of exploring the planet on a human scale and performing a wide range of in situ measurements at different locations. Different mission scenarios are currently being studied with the goal of achieveing sample return before the end of the century.

Carr, Michael H.↗

Mineralogic and petrologic implications of Viking geochemical results from Mars - Interim report

Chemical results from four samples of Martian fines delivered to Viking landers 1 and 2 are remarkably similar in that they all have high iron; moderate magnesium, calcium, and sulfur; low aluminum; and apparently very low alkalies and trace elements. This composition is best interpreted as representing the weathering products of mafic igneous rocks. A mineralogic model, derived from computer mixing studies and laboratory analog preparations, suggests that Mars fines could be an intimate mixture of about 80% iron-rich clay, about 10% magnesium sulfate (kieserite), about 5% carbonate (calcite), and about 5% iron oxides (hematite, magnetite, maghemite, goethite). The mafic nature of the present fines (distributed globally) and their probable source rocks seems to preclude large-scale planetary differentiation of a terrestrial nature.

Baird, A. K.↗

Automated Microbial Metabolism Laboratory

Development of the automated microbial metabolism laboratory (AMML) concept is reported. The focus of effort of AMML was on the advanced labeled release experiment. Labeled substrates, inhibitors, and temperatures were investigated to establish a comparative biochemical profile. Profiles at three time intervals on soil and pure cultures of bacteria isolated from soil were prepared to establish a complete library. The development of a strategy for the return of a soil sample from Mars is also reported.

Source record↗

The Inventory of Interstellar Materials Available for the Formation of the Solar System

Dr. Derek Sears, the editor of the journal Meteoritics and Planetary Science, has established a policy of having each issue of the journal contain an invited review of an area that he deems to be of special cur-rent importance. Typically 20 to 25 pages of the beginning of the journal are devoted to each review. He has asked me to prepare such a review summarizing what we know about the composition and structure of interstellar materials. The attached paper is the result. This is a good time for such a review since tremendous progress has been made in the field of interstellar dust in recent years through the use of telescopic observations, theoretical studies, laboratory studies of analogs, and the study of actual interstellar samples found in meteorites. It is increasing clear that the interstellar medium (ISM) contains an enormous diversity of materials created by a wide range of chemical and physical processes. This understanding is a far cry from the picture of interstellar materials held as recently as two decades ago, a picture which incorporated only a few generic types of grains and few molecules. In the paper I review our current knowledge of the more abundant materials thought to exist in the ISM. The review concentrates on matter in interstellar dense molecular clouds since it is the materials in these environments from which new stars and planetary systems are formed, although materials in circumstellar environments and in the diffuse ISM are also discussed. The paper focuses largely on solid materials since they contain a major fraction of the heavier elements in clouds and because solids are most likely to survive incorporation into new planetary systems in identifiable form. The paper concludes with discussion of some of the implications resulting from the identification of these interstellar materials. I also present some new thoughts, the most intriguing being that meteoritic 'microdiamonds' may be the same material that modelers of the interstellar extinction call graphite! If my suggestion is correct it will help resolve the dilemma associated with the current over-subscription of cosmic C and should lead to some new approaches to both extinction models and the study of meteoritic interstellar microdiamonds.

Sandford, Scott A.↗

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

gene expression↗

Successful Validation of Sample Processing and Quantitative Real-Time PCR Capabilities on the International Space Station

The WetLab-2 system was developed by NASA Ames Research Center to offer new capabilities to researchers. The system can lyse cells and extract RNA (Ribonucleic Acid) on-orbit from different sample types ranging from microbial cultures to animal tissues. The purified RNA can then either be stabilized for return to Earth or can be used to conduct on-orbit quantitative Reverse Transcriptase PCR (Polymerase Chain Reaction) (qRT-PCR) analysis without the need for sample return. The qRT-PCR results can be downlinked to the ground a few hours after the completion of the run. The validation flight of the WetLab-2 system launched on SpaceX-8 on April 8, 2016. On orbit operations started on April 15th with system setup and was followed by three quantitative PCR runs using an E. coli genomic DNA template pre-loaded at three different concentrations. These runs were designed to discern if quantitative PCR functions correctly in microgravity and if the data is comparable to that from the ground control runs. The flight data showed no significant differences compared to the ground data though there was more variability in the values, this was likely due to the numerous small bubbles observed. The capability of the system to process samples and purify RNA was then validated using frozen samples prepared on the ground. The flight data for both E. coli and mouse liver clearly shows that RNA was successfully purified by our system. The E. coli qRT-PCR run showed successful singleplex, duplex and triplex capability. Data showed high variability in the resulting Cts (Cycle Thresholds [for the PCR]) likely due to bubble formation and insufficient mixing during the procedure run. The mouse liver qRT-PCR run had successful singleplex and duplex reactions and the variability was slightly better as the mixing operation was improved. The ability to purify and stabilize RNA and to conduct qRT-PCR on-orbit is an important step towards utilizing the ISS as a National Laboratory facility. The ability to get on-orbit data will provide investigators with the opportunity to adjust experimental parameters in real time without the need for sample return and re-flight. The WetLab-2 Project is supported by the Research Integration Office in the ISS Program.

quantitative PCR↗

TEMPUS: First results

The electromagnetic levitation facility, TEMPUS, developed by Dornier is designed to operate under microgravity conditions. Compared to terrestrial levitation, microgravity offers the possibility to melt and undercool in ultra high vacuum, thereby, providing an ultra clean environment. The technical concept of the TEMPUS facility was tested on two KC 135 flights and in the Texus 22 mission. Preparative investigations concerning the coil system and the heating and positioning efficiencies were carried out in the TEMPUS laboratory version. Furthermore, temperature-time profiles were determined under various boundary conditions. As a consequence of processing liquid metals under UHV, correct temperature measurement arises as the most critical problem. Experiences with experiments in the TEMPUS laboratory module show that due to the evaporation losses of the sample, the transmission of the CaF2 shielding windows changes drastically during the processing time. The investigation of the effect of contamination on pyrometry and the development of alternative evaporation shielding methods were initiated. During the second KC 135 flight, it was possible to heat up and melt an FeNi sample under He atmosphere. Oscillations of the molten sample, which were excited by switching out the magnetic heating field, could be detected and afterwards analyzed. From the frequency of these oscillations the surface tension of the sample material could be derived. The measurement of the surface tension and viscosity of an undercooled metal is proposed for TEMPUS on IML-2. This document is presented in view graph form.

Neuhaus, P.↗

Simulation of Spiral Slot Antennas on Composite Platforms

The project goals, plan and accomplishments up to this point are summarized in the viewgraphs. Among the various accomplishments, the most important have been: the development of the prismatic finite element code for doubly curved platforms and its validation with many different antenna configurations; the design and fabrication of a new slot spiral antennas suitable for automobile cellular, GPS and PCs communications; the investigation and development of various mesh truncation schemes, including the perfectly matched absorber and various fast integral equation methods; and the introduction of a frequency domain extrapolation technique (AWE) for predicting broadband responses using only a few samples of the response. This report contains several individual reports most of which have been submitted for publication to referred journals. For a report on the frequency extrapolation technique, the reader is referred to the UM Radiation Laboratory report A total of 14 papers have been published or accepted for publication with the full or partial support of this grant. Several more papers are in preparation.

Volakis, John L.↗

Algorithmic Classification of Raman Spectra Biosignatures: Improving Life Detection Confidence

“Agnostic” biosignatures – indicators of life (or the absence of life), independent of a particular biochemistry – are increasingly considered a high standard for life detection. The Ladder of Life Detection (2018) called for investigating how combinations of independent and different potential biosignatures affect confidence. To address this gap, statistical classification of elemental abundances, isotopic fractionation, and reflectance spectroscopy (VNIR) has been implemented. Raman spectroscopy, highly desirable due to its wide availability, has the potential to improve this predictive power. This work implemented biosignature classification algorithms on Raman data alone, in preparation for combination with the other data types. Raman spectroscopy data was collected from published databases and papers as part of a manually curated dataset of “indicative” and “non-indicative of life” samples. These currently include 61 non-indicative samples (meteorites, magnetite); 3 indicative living samples (bacteria); 20 indicative non-living samples (chalk, bone); and 12 indicative mixed (with non-indicative material) samples (soil, microbial mats). Laboratory work is ongoing to characterize additional samples, particularly a greater breadth of mixed systems. Spectra were interpolated, filtered with the Savitzsky-Golay filter, and de-noised. For a preliminary examination, agnostic features were manually extracted including mean intensity, number of peaks, and mean peak width. Different peak prominences and filtering polynomials were used to refine features. Classification algorithms were implemented: k-nearest neighbors (KNN), logistic regression (LR), linear support vector machines (SVM), random forest (RF), Gaussian naïve bayes (GNB). Lastly, Monte Carlo simulations on 1,000 50%-train-test-splits were used to validate classification performance and feature significance. The preliminary feature set achieved its highest AUC of 0.52 with LR, with no strongly discriminatory features. Work to improve feature extraction, such as through deep learning with back propagation, is planned. In future work, the Raman data will be combined with the other data types, and potentially new data types such as enantiomeric excess. This project was partially supported through the NASA Ames Project EXcellence (APEX) incubator program.

Astrobiology↗

Further laboratory study of the diffuse reflectance spectra of frosts occurring on astronomical objects

Oligoclase and bloedite, two mined samples, have been investigated, and the diffuse reflectance spectra are presented. These data are for powdered material, 50 microns to 5 microns size mixture, cooled to 160 K. The reflectivity of the oligoclase sample was also measured at room temperature, about 290 K, and the results at these two temperatures do indicate some tentative differences. A frost of ordinary water was prepared and its spectral reflectance is presented. This result compares reasonably well with measurements made by other investigators.

Glaser, F. M.↗

Modification of Experimental Protocols for a Space Shuttle Flight and Applications for the Analysis of Cytoskeletal Structures During Fertilization, Cell Division , and Development in Sea Urchin Embryos

To explore the role of microgravity on cytoskeletal organization and skeletal calcium deposition during fertilization, cell division, and early development, the sea urchin was chosen as a model developmental system. Methods were developed to employ light, immunofluorescence, and electron microscopy on cultures being prepared for flight on the Space Shuttle. For analysis of microfilaments, microtubules, centrosomes, and calcium-requiring events, our standard laboratory protocols had to be modified substantially for experimentation on the Space Shuttle. All manipulations were carried out in a closed culture chamber containing 35 ml artificial sea water as a culture fluid. Unfertilized eggs stored for 24 hours in these chambers were fertilized with sperm diluted in sea water and fixed with concentrated fixatives for final fixation in formaldehyde, taxol, EGTA, and MgCl2(exp -6)H2O for 1 cell to 16 cell stages to preserve cytoskeletal structures for simultaneous analysis with light, immunofluorescence, and electron microscopy, and 1.5 percent glutaraldehyde and 0.4 percent formaldehyde for blastula and plueus stages. The fixed samples wre maintained in chambers without degradation for up to two weeks after which the specimens were processed and analyzed with routine methods. Since complex manipulations are not possible in the closed chambers, the fertilization coat was removed from fixation using 0.5 percent freshly prepared sodium thioglycolate solution at pH 10.0 which provided reliable immunofluorescence staining for microtubules. Sperm/egg fusion, mitosis, cytokinesis, and calcium deposition during spicule formatin in early embryogenesis were found to be without artificial alterations when compared to cells fixed fresh and processed with conventional methods.

Chakrabarti, Amitabha↗

Recommended Laboratory and Field Studies ahead of Future Mercury Exploration

Data from Mariner 10, MESSENGER, and ground-based telescopic observations have facilitated great advancements towards understanding the geochemistry, geology, internal structure, and space environment (exosphere/magnetosphere) of Mercury. Future exploration efforts by BepiColombo, landed science, and sample return will revolutionize our understanding of this planet. However, to enhance the scientific return of past, present, and future data collection at Mercury, it is imperative that laboratory and field-based studies be conducted over the next decade. This white paper gives examples of laboratory and field studies, including instrument testing, which should take place over the next decade to facilitate the interpretation of data and preparation of future missions to the inner-most planet. By no means are the topics in this paper exhaustive, but rather are meant to demonstrate the immense amount of work that needs to be completed ahead of, or in conjunction with, current and future exploration efforts of Mercury. This work would amplify the benefits from additional data obtained from the planet’s surface to the fullest extent possible, and to aid in decision making of future instrument payloads. We have chosen to focus our inputs here on geochemistry, geology, and space environment related efforts, but we emphasize that extensive research in the areas of geophysics and other geosciences-related disciplines will benefit from additional studies.

Kathleen E. Vander Kaaden↗

NASA Work Experience

I have had the opportunity to support the analytical laboratories in chemical analysis of unknown samples, using Optical Microscopy (OM), Polarizing Light Microscopy (PLM), Fourier-Transform Infrared Spectroscopy (FT-IR), Scanning Electron Microscopy with Energy Dispersive Spectroscopy (SEMEDS), and X-ray Powder Diffraction (XPD). I have assisted in characterizing fibers pulled from a spacecraft, a white fibrous residue discovered in a jet refueler truck, brown residue from a plant habitat slated for delivery to the ISS (International Space Station), corrosion on a pipe from a sprinkler, and air filtration material brought back from the ISS. I also conducted my own fiber study in order to practice techniques and further my understanding of background concepts. Furthermore, I had the opportunity to participate in diverse work assignments, where I was assigned to work with other branches of the engineering department for 1-2 days each. The first was in the Materials Science branch where I participated in the construction of the plant habitat intended for use in research aboard the ISS. The second was in the Testing Design branch where I assisted with tensile and hardness testing of over 40 samples. In addition, I have had the privilege to attend multiple tours of the NASA KSC campus, including to the Astronaut Crew Quarters, the VAB (the main area, the Columbia room, and the catwalk), the Visitor Center housing the shuttle Atlantis, the Saturn-V exhibit, the Prototype laboratory, SWAMP WORKS, the Shuttle Landing Facility, the Crawler, and the Booster Fabrication Facility (BFF). Lastly, much of my coursework prepared me for this experience, including numerous laboratory courses with topics diverse as chemistry, physics, and biology.

Florida Tech↗

Analysis of Direct Samples of Early Solar System Aqueous Fluids

Over the past three decades we have become increasingly aware of the fundamental importance of water, and aqueous alteration, on primitive solar-system bodies. Some carbonaceous and ordinary chondrites have been altered by interactions with liquid water within the first 10 million years after formation of their parent asteroids. Millimeter to centimeter-sized aggregates of purple halite containing aqueous fluid inclusions were found in the matrix of two freshly-fallen brecciated H chondrite falls, Monahans (1998, hereafter simply "Monahans") (H5) and Zag (H3-6) (Zolensky et al., 1999; Whitby et al., 2000; Bogard et al., 2001) In order to understand origin and evolution of the aqueous fluids inside these inclusions we much measure the actual fluid composition, and also learn the O and H isotopic composition of the water. It has taken a decade for laboratory analytical techniques to catch up to these particular nanomole-sized aqueous samples. We have recently been successful in (1) measuring the isotopic composition of H and O in the water in a few fluid inclusions from the Zag and Monahans halite, (2) mineralogical characterization of the solid mineral phases associated with the aqueous fluids within the halite, and (3) the first minor element analyses of the fluid itself. A Cameca ims-1270 equipped with a cryo-sample-stage of Hokkaido University was specially prepared for the O and H isotopic measurements. The cryo-sample-stage (Techno. I. S. Corp.) was cooled down to c.a. -190 C using liquid nitrogen at which the aqueous fluid in inclusions was frozen. We excavated the salt crystal surfaces to expose the frozen fluids using a 15 keV Cs+ beam and measured negative secondary ions. The secondary ions from deep craters of approximately 10 m in depth emitted stably but the intensities changed gradually during measurement cycles because of shifting states of charge compensation, resulting in rather poor reproducibility of multiple measurements of standard fluid inclusions of +/- 90 0/00(2 sigma) for delta D, and +/- 29 0/00 (2 sigma) for delta O-18. On the other hand, the reproducibility of Delta O-17 is plus or minus 8 /00 (2 sigma ) because the observed variations of isotope ratios follow a mass dependent fractionation law. Variations of delta D of the aqueous fluids range over sog,a 330(90; 2 sigma ) to +1200(90) 0/00 for Monahans and delta 300(96) 0/00 to +90(98)0/00 for Zag. Delta O-17 of aqueous fluids range over delta 16(22) 0/00 to +18(10) 0/00 for Monahans and +3(10) 0/00 to +27(11) 0/00 for Zag. These variations are larger than the reproducibility of standard analyses and suggest that isotope equilibria were under way in the fluids before trapping into halite. The mean values of delta D and Delta O-17 are +290 0/00 and +9 0/00, respectively. The mean values and the variations of these fluids are different from the representative values of ordinary chondrites, verifying our working hypothesis that the fluid inclusion-bearing halites were not indigenous to the H chondrite parent-asteroid but rather represent exogenous material delivered onto the asteroid from a separate cryovolcanically-active body. This initial isotopic work has demonstrated the feasibility of the measurements, but also revealed sample processing and analytical shortcomings that are now being addressed. Examination of solid mineral inclusions within Monahans and Zag halite grains by confocal Raman spectroscopy at the Carnegie Geophysical Laboratory has revealed them to be metal, magnetite, forsteritic olivine (Fo.98), macromolecular carbon (MMC), pyroxenes, feldspar with Raman spectral affinity to anorthoclase and, probably, fine-grained lepidocrocite (FeO(OH)). In addition, one inclusion features aliphatic material with Raman spectral features consistent with a mixture of short-chain aliphatic compounds. We have initiated analyses of the bulk composition of the fluids within the inclusions in Zag and Monahans halites at Virginia Tech by LA ICPMS using angilent 7500ce quadrupole ICPMS and a Lambda Physik GeoLas 193 nm excimer laser ablation system. Preliminary results reveal that the inclusion aqueous fluids contain highly charged cations of Ca, Mg and Fe. The minerals and compounds discovered thus far within Monahans/Zag halites are indicative of an originating body at least partly composed of unequilibrated anhydrous materials (high Fo olivine, pyroxenes, feldspars, possibly the metal) which were subjected to aqueous alteration (the halite parent brine) and containing a light organic component (the short-chain aliphatic compounds). This material was ejected from the originating body with little or no disruption, as evidenced with the presence of fluid inclusions. An actively geysering body similar to modern Enceladus (Postberg et al., 2011) may be a reasonable analogue in this respect. Also, the originating body should have been within close proximity to the H chondrite parent in order to generate the number of halite grains seen in Monahans and Zag. Other candidates for Monahans/Zag halite parent bodie(s) may include a young Ceres with its possible liquid ocean, or Main Belt comets.

Zolensky, Michael E.↗

In Situ Noble-Gas Based Chronology on Mars

Determining radiometric ages in situ on another planet's surface has never been done, and there are good reasons to think that it will be extremely difficult. It is certainly hard to imagine that such ages could be measured as precisely as they could be measured on returned samples in state-of-the-art terrestrial laboratories. However, it may be possible, by using simple noble-gas-based chronology techniques, to determine ages on Mars to a precision that is scientifically useful. This abstract will: (1) describe the techniques we envision; (2) give some examples of how such information might be scientifically useful; and (3) describe the system we are developing, including the requirements in terms of mass, power, volume, and sample selection and preparation.

Swindle, T. D.↗

RESOLVE Project

The RESOLVE project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph- mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize C!Jmponent and integrated system performance. Ray will be assisting with component testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments. He will be developing procedures to guide these tests and test reports to analyze and draw conclusions from the data. In addition, he will gain experience with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer, WDD, Sample Delivery System, and GC-MS in the vacuum chamber. This testing will provide hands-on exposure to a flight forward spaceflight subsystem, the processes associated with testing equipment in a vacuum chamber, and experience working in a laboratory setting. Examples of specific analysis Ray will conduct include: pneumatic analysis to calculate the WOO's efficiency at extracting water vapor from the gas stream to form condensation; thermal analysis of the conduction and radiation along a line connecting two thermal masses; and proportional-integral-derivative (PID) heater control analysis. In this Research and Technology environment, Ray will be asked to problem solve real-time as issues arise. Since LAVA is a scientific subsystem, Ray will be utilizing his chemical engineering background to operate the near-infrared spectrometer and GC-MS instruments during ETU testing. Ray will be working with Modified Commercial off the Shelf (MCOTS) instruments and characterizing their analytical behavior for optimization. Ray will be offered the opportunity to suggest testing modifications or configuration changes at any time to improve the experimental effectiveness. He will gain many skills needed for working in a technical team setting requiring flexibility and critical thinking.

Parker, Ray O.↗