TRUPACT-III Program Guidance (Rev. 0)

The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model IIl (TRUPACT-IlI) and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-lII Safety Analysis Report for Packaging (SARP) and U.S. Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) No. 9305.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of the Cause of Low Blister Threshold Temperatures in the RERTR-12 and AFIP-4 Experiments

Blister–threshold testing of fuel plates is a standard method through which the safety margin for operation of plate-type in research and test reactors is assessed. The blister-threshold temperature is indicative of the ability of fuel to operate at high temperatures for short periods of time (transient conditions) without failure. This method of testing was applied to the newly developed U-Mo monolithic fuel system. Blister annealing studies on the U-Mo monolithic fuel plates began in 2007, with the Reduced Enrichment for Research and Test Reactors (RERTR)-6 experiment, and they have continued as the U-Mo fuel system has evolved through the research and development process. Blister anneal threshold temperatures from early irradiation experiments (RERTR-6 through RERTR-10) ranged from 400 to 500°C. These temperatures were projected to be acceptable for NRC-licensed research reactors and the high-power Advanced Test Reactor (ATR) and the High Flux Isotope Reactor (HFIR) based on current safety-analysis reports (SARs). Initial blister testing results from the RERTR-12 experiment capsules X1 and X2 showed a decrease in the blister-threshold temperatures. Blister threshold temperatures from this experiment ranged from 300 to 400°C. Selected plates from the AFIP-4 experiment, which was fabricated using a process similar to that used to fabricate the RERTR-12 experiment, also underwent blister testing to determine whether results would be similar. The measured blister-threshold temperatures from the AFIP-4 plates fell within the same blister-threshold temperature range measured in the RERTR-12 plates. Investigation of the cause of this decrease in bister threshold temperature is being conducted under the guidance of Idaho National Laboratory PLN-4155, “Analysis of Low Blister Threshold Temperatures in the RERTR-12 and AFIP-4 Experiments,” and is driven by hypotheses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Verification and validation of the PLTEMP/ANL code for thermal hydraulic analysis of experimental and test reactors

The document compiles in a single volume several verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. Some works that are available in the open literature are simply referenced at the outset, and are not included in the document. PLTEMP has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a more validated code like the RELAP5 code.

Kalimullah, M.↗

Managing Aging Effects on Dry Cask Storage Systems for Extended Long-Term Storage and Transportation of Used Fuel – Revision 1

Because there is currently no designated disposal site for used nuclear fuel in the United States, the nation faces the prospect of extended long-term storage (i.e., >120 years) and deferred transportation of used fuel at operating and decommissioned nuclear power plant sites. Under U.S. federal regulations contained in Title 10 of the Code of Federal Regulations (CFR) 72.42, the initial license term for an Independent Spent Fuel Storage Installation (ISFSI) must not exceed 40 years from the date of issuance. Licenses may be renewed by the U.S. Nuclear Regulatory Commission (NRC) at the expiration of the license term upon application by the licensee for a period not to exceed 40 years. Applications for ISFSI license renewals must include the following: 1. Time-limited aging analyses (TLAAs) that demonstrate that structures, systems, and components (SSCs) important to safety will continue to perform their intended function for the requested period of extended operation, and 2. A description of the aging management program (AMP) for management of issues associated with aging that could adversely affect SSCs important to safety. In addition, the application must include design basis information as documented in the most recently updated final safety analysis report, as required by 10 CFR 72.70. Information contained in previous applications, statements, or reports filed with the Commission under the license may be incorporated by reference, provided that these references are clear and specific.

Chopra, O. K.↗

Global Threat Reduction Initiative Fuel-Thermo-Physical Characterization Project Quality Assurance Plan

The charter of the Fuel Thermo-Physical Characterization Project is to ready Pacific Northwest National Laboratory (PNNL) facilities and processes for the receipt of unirradiated and irradiated low enriched uranium (LEU) molybdenum (U-Mo) fuel element samples, and to perform analysis to support the Global Threat Reduction Initiative conversion program. PNNL’s support for the program will include the establishment of post-irradiation examination processes, including thermo-physical properties, unique to the U.S. Department of Energy laboratories. These processes will ultimately support the submission of the base fuel qualification (BFQ) to the U.S. Nuclear Regulatory Commission (NRC) and revisions to High Performance Research Reactor Safety Analysis Reports to enable conversion from highly enriched uranium to LEU fuel. This quality assurance plan (QAP) provides the quality assurance requirements and processes that support the NRC BFQ. This QAP is designed to be used by project staff, and prescribes the required management control elements that are to be met and how they are implemented. Additional controls are captured in Fuel Thermo-Physical Characterization Project plans, existing procedures, and procedures to be developed that provide supplemental information on how work is conducted on the project.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating the use of PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of nuclear canister filters

This document details the distinction between using PAO (4 cSt polyalphaoelfin) oil instead of DOP (di-octyl phthalate) oil for measuring the aerosol capture of filters. This document is developed to justify the use of PAO rather than DOP for evaluating the performance of filters in the SAVY 4000 and Hagan containers. The design criteria (Anderson et al, 2012) for purchasing SAVY 4000 containers and the Safety Analysis Report for the SAVY 4000 Container Series specified that the filter must “capture greater than 99.97% of 0.45 μm mean diameter dioctyl phthalate (DOP) aerosol at the rated flow with a DOP concentration of 65±15 micrograms per liter.”This corresponds to a leakage percent of 0.03% (3.0x10 -2 ). The density of DOP oil is 985 kg/m 3 and the density of PAO oil is 819 kg/m 3 . ATI Test Inc measured the mass mean diameter of aerosol distributions produced by a single Laskin type III-A nozzle operating at a 20 psig air pressure as 0.563 μm for DOP oil and 0.549 μm for PAO oil. (See Appendix A.) For both types of oil in this document, the single fiber method calculated the leakage percent to be 4.4x10 -5 for DOP oil and 4.7x10 -5 for PAO oil. Although the percent error between these two quantities is 7.7%, these calculated leakage percent values are more than two orders of magnitude less than the criterion specified in the SAVY canister SAR. As a point of reference, the photometer used to measure the SAVY canister filter performance cannot resolve values for the leakage percent below 1.0x10 -5 . Additionally, over a range of particle sizes from 0.01 μm to 3.0 μm, there was less than 4.0x10 -5 error between the calculated filter efficiency for the two types of oil at any particular particle size diameter. In conclusion, the difference between using DOP and PAO for testing SAVY canister filters is of inconsequential concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Managing Aging Effects on Dry Cask Storage Systems for Extended Long-Term Storage and Transportation of Used Fuel (Rev. 2)

At present, the United States does not have a designated disposal site for used nuclear fuel — the nation therefore faces the prospect of extended long‐term storage (i.e., >60 years) and deferred transportation of used fuel at operating and decommissioned nuclear power plant sites. Under current U.S. federal regulations contained in Title 10 of the Code of Federal Regulations (CFR) 72.42, the initial license term for an Independent Spent Fuel Storage Installation (ISFSI) must not exceed 40 years from the date of issuance (20 years before the rule change in 2010 that became effective in 2011). The U.S. Nuclear Regulatory Commission (NRC) may renew licenses at the expiration of the license term upon application by the licensee for a period not to exceed 40 years. Applications for ISFSI license renewals must include the following: 1. Time‐limited aging analyses (TLAAs) that demonstrate that structures, systems, and components (SSCs) important to safety will continue to perform their intended function for the requested period of extended operation and 2. A description of the aging management program (AMP) for the management of issues associated with aging that could adversely affect SSCs important to safety. In addition, the application must include design basis information as documented in the most recently updated final safety analysis report, as required by 10 CFR 72.70. Information contained in previous applications, statements, or reports filed with the Commission under the license may be incorporated by reference, provided that these references are clear and specific. The NRC has issued the “Standard Review Plan for Renewal of Spent Fuel Dry Cask Storage System Licenses and Certificates of Compliance,” NUREG‐1927, under which NRC may renew a specific license or a Certificate of Compliance (CoC) for a term not to exceed 40 years. Both the license and the CoC renewal applications must contain revised technical requirements and operating conditions (fuel storage, surveillance and maintenance, and other requirements) for the ISFSI and dry cask storage system (DCSS) that address aging effects that could affect the safe storage of the used fuel. The information contained in the license and CoC renewal applications will require NRC review to verify that the aging effects on the SSCs in DCSSs/ISFSIs are adequately managed for the requested period of extended operation. To date, all of the ISFSIs across the United States with more than 1,500 dry casks loaded with used fuel have initial license terms of 20 years — three ISFSIs (Surry, H.B. Robinson, and Oconee) have received their renewed licenses for 40 years, and two other ISFSIs (Calvert Cliffs and Prairie Island) have applied for license renewal for 40 years. In addition, renewal of the CoC for the VSC‐24 system is pending approval from NRC.

Chopra, O. K.↗

CSR behavior and aging model for the Viton© Fluorelastomer O-rings in the 9975 shipping package

The 9975 Type B shipping package is used within the DOE complex for shipping special nuclear materials. This package is re-certified annually in accordance with Safety Analysis Report for Packaging (SARP) requirements. The package is also used at the Savannah River Site as part of the long-term storage configuration of special nuclear materials. As such, the packages do not undergo annual recertification during storage, with uncertainty as to how long some of the package components will meet their functional requirements in the storage environment. The packages are currently approved for up to 15 years storage, and work continues to provide a technical basis to extend that period. This report describes efforts by the Savannah River National Laboratory (SRNL) to extend the service life estimate of Viton® GLT and GLT-S fluoroelastomer O-rings used in the 9975 shipping package. O-rings of both GLT and GLT-S compositions are undergoing accelerated aging at elevated temperature, and are periodically tested for compression stress relaxation (CSR) behavior. The CSR behavior of O-rings was evaluated at temperatures from 175 to 400 °F. These collective data were used to develop predictive models for extrapolation of CSR behavior to relevant service temperatures (< 156 °F). The predictive model developed from the CSR data conservatively indicates a service life of approximately 37 years for Viton GLT O-rings at the maximum effective service temperature of 156 °F. The estimated service life for Viton GLT-S O-rings is significantly longer.

36 MATERIALS SCIENCE↗

Dose Rate Evaluation for the ES-3100 Package with HEU Content Using MCNP, ADVANTG, Monaco, and MAVRIC

This paper presents a comparative study of dose rate calculations for the ES-3100 package with highly enriched uranium (HEU) content for different source configurations using computer codes: (1) MCNP; (2) Automated Variance Reduction Generator (ADVANTG)/MCNP; (3) Monaco; and (4) Monaco with Automated Variance Reduction using Importance Calculations (MAVRIC). The Model ES-3100 package was developed at the Y-12 National Security Complex for domestic and international transportation of Type B fissile radioactive material. In this study, six different source configurations (i.e., solid cylinder, cylindrical hemi-shell, cylindrical shell, rectangular plate, cylindrical rod, or cylindrical segment form) having 36 kg of HEU metal inside the package containment vessel (based on configurations in the ES-3100/HEU safety analysis report for packaging) are evaluated. Dose rates at the package surfaces and 1 m from the package surfaces are calculated for these different source configurations. MCNP and Monaco cases are run without any biasing options to accelerate the convergence. Consistent Adjoint Driven Importance Sampling (CADIS) and Forward-Weighted CADIS (FW-CADIS) methods developed at the Oak Ridge National Laboratory are implemented in ADVANTG/MCNP and MAVRIC codes to accelerate the convergence. ADVANTG generates variance reduction parameters using Denovo code, and MCNP is used with the variance reduction parameters to accelerate the convergence. MAVRIC uses Denovo code to construct an importance map and a biased source distribution that are supplied to Monaco to accelerate the Monte Carlo simulation. The FW-CADIS option in ADVANTG and MAVRIC is used to accelerate the convergence in this study. The accelerated convergence cases (ADVANTG/MCNP and MAVRIC) are about 100 times faster with 100 times less particle simulation than those cases run without biasing options (analog MCNP and analog Monaco). The MCNP, ADVANTG/MCNP, Monaco, and MAVRIC calculated dose rates at the package surfaces and at 1 m from the package surfaces for the different source configurations are compared and are found to be in general agreement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hydrogen Gas Concentration in Model 9979 Type AF Containers at Los Alamos National Laboratory

Between May 2016 and July 2017 Los Alamos National Laboratory (LANL) packaged sixty eight Model 9979 Type AF containers with solid, non -combustible low -level waste (LLW) in accordance with S-SARP -G-00006, R4, Safety Analysis Report for Packagings, Model 9979 Type AF Shipping Package. The LLW items were packed into inner metal containers (convenience cans). There are no additional materials inside convenience cans, and the material was controlled during loading to ensure each Model 9979 package has less than 350 grams (total) of U -235. All LANL packages include an insulation bag and top, and 5.7 kg of granular boron carbide. The minimum void volume fraction that is present in LANL containers is calculated to be 48%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors

The document compiles in a single volume the verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. The verification of sixteen capabilities of the PLTEMP/ANL Version 4.3 code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis are described and documented. Each chapter of the document deals with the verification or validation of a specific model. The model verification is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The model validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL verification works that are available in the open literature are simply referenced and not included in the document. PLTEMP/ANL has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads

The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proposed Alternate Methodology for Preparation of a Documented Safety Analysis for the Transformational Challenge Reactor

10 CFR Part 830, Subpart B, Appendix A, Table 2 lists acceptable methodologies for development of a Documented Safety Analysis (DSA) for various types of nuclear facilities. The acceptable methodology listed for a DOE reactor is U.S. Nuclear Regulatory Commission Regulatory Guide 1.70, Standard Format and Content of Safety Analysis Reports for Nuclear Power Plants, or successor document. This document was developed for large commercial light-water power reactors. The difference between the Transformational Challenge Reactor (TCR) and commercial reactors in power output, radiological source term, fuel type and composition, and operational life span makes application of the Regulatory Guide to the TCR overly burdensome relative to the value added.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Massachusetts Institute of Technology Reactor LEU Fuel Element Flow Test Conceptual Design – Hydraulic Reactor Design Parameters

The Massachusetts Institute of Technology Reactor (MITR-II, also referred to as MITR) is one of six U.S. high performance research reactors (USHPRR), including one critical facility, that is actively collaborating with the U.S. National Nuclear Security Administration (NNSA) Material Management and Minimization (M 3 ) Reactor Conversion Program to convert to the use of low-enriched uranium (LEU, < 20 wt% 235 U) fuel. The MIT Nuclear Reactor Laboratory has been working with the USHPRR Reactor Conversion (RC) Pillar at Argonne National Laboratory to perform fuel element design and fuel cycle performance analyses, steady-state thermal hydraulics safety analyses, and accident safety analyses in preparation for the conversion of MITR and support a preliminary Safety Analysis Report (SAR) for conversion to LEU fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors (Code Version 4.3)

The document compiles in a single volume the verification and validation works done for the PLTEMP/ANL code during the years of its development and improvement. The verification of sixteen capabilities of the PLTEMP/ANL Version 4.3 code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis are described and documented. Each chapter of the document deals with the verification or validation of a specific part of the software that calculates a specific phenomenon, e.g., channel flow calculation, coolant property calculation, heat transfer calculation, and flow instability calculation. The software verification work is usually done by comparing the code with hand calculation, Microsoft spreadsheet calculation, or Mathematica calculation. The software validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL verification works that are available in the open literature are simply referenced and not included in the document. PLTEMP/ANL has been used in conversion safety analysis reports of several US and foreign research reactors that have been licensed and converted. A list of such reactors is given.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

University of Missouri Research Reactor (MURR) LEU Fuel Fluid-Structure Interaction Analysis

The University of Missouri Research Reactor (MURR ® ) is one of five U.S. high performance research reactors (USHPRR), plus one critical facility, that are actively collaborating with the National Nuclear Security Administration (NNSA) Material Management and Minimization (M 3 ) Reactor Conversion Program to convert from highly enriched uranium (HEU, ≥ 20 wt.% U-235) to low-enriched uranium (LEU, < 20 wt.% U-235) fuel. A new type of LEU fuel with very high density, based on an alloy of uranium and 10 weight percent molybdenum (U-10Mo), is expected to allow the conversion to LEU of USHPRR that have been found unable to be converted with previously qualified uranium silicide-aluminum (U 3 Si 2 -Al) dispersion fuel. MURR has been working with the USHPRR Reactor Conversion (RC) Pillar at Argonne National Laboratory to perform fuel element design and fuel cycle performance analyses, steady-state thermal hydraulics safety analyses, and accident safety analyses in preparation for the conversion of MURR and to support a preliminary Safety Analysis Report (SAR) for conversion to LEU fuel. In this work, Fluid-structure interaction (FSI) analysis at the fuel element level, as compared to the fuel plate level of the previous work. is performed which models all components of the MURR LEU fuel element, including fuel plates and the supporting structures e.g., side plates, end fittings, and combs. Therefore, the effect of supporting structures on the coolant flow distribution, the fuel plate deflection, and the resulting coolant channel gap reduction can be evaluated. In addition to the nominal element geometry and flow rate, the tolerances in the geometry dimensions of coolant channel and plate thickness, the effect of a comb on plate deflection, and the uncertainty of the flow rate per element are considered in this work. The effect of comb on plate displacement is quantified through two bounding cases: the case assuming a perfect bond between the comb and plates and the case neglecting the comb effect. Note that in this analysis, the FSI has been decoupled from the other structural effects caused by irradiation (e.g., swelling and irradiation creep). Assessment of combined effects is planned for a later stage of this project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Foam Degradation Model during Thermal Hypothetical Accident Conditions

Current practice in Safety Analysis Report for Packaging (SARP) thermal analysis for hypothetical accident conditions (HAC) of packages is to not explicitly model the consequence to the foam impact limiting material, but instead to make conservative estimates of those consequences and begin calculations from that point. This approach is typically used for the foam regression distance, which is the thickness of the degraded foam layer after the 30-minute fire event. Estimates for regression distance can come directly from package burn test results or from correlations based on one-dimensional testing by the foam manufacturer. In either case, this is a subjective process, and although it can be used to produce a conservative result, it is a significant approximation in the analysis. This paper describes testing and refinement of a simplified foam regression model. Comparisons are made against available data from laboratory experiments. Model refinements were tested until satisfactory agreement was achieved. The final modeling approach was then compared with post-test inspection results from HAC burn test data. A new model with an effective thermal conductivity based on foam to char density variation was shown successful in representing laboratory-scale foam thermal degradation experiments and full-scale burn tests of a current package. This model offers a technically defensible and predictive approach for modeling thermal degradation of rigid polyurethane insulation in transport packages.

36 MATERIALS SCIENCE↗

Verification and Validation of the PLTEMP/ANL Code for Thermal-Hydraulic Analysis of Experimental and Test Reactors, Volume 1

This is Volume 1 of a two-volume document that collects the verification and validation (V&V) works done for the PLTEMP/ANL code during the years of its development and improvement. Volume 1 describes the V&V of sixteen capabilities of the PLTEMP/ANL code that were identified by research reactor analysts as frequently used in their thermal-hydraulic analysis. Volume 2 describes the V&V of developments and improvements since the release of PLTEMP/ANL Version 4.3. Each chapter of the document focuses on verifying or validating a specific part of the software that calculates a specific phenomenon, e.g., channel flow calculation, coolant property calculation, heat transfer calculation, and flow instability calculation. Software verification is performed by comparing the code with hand calculation, Microsoft spreadsheet calculation, Mathematica calculation, or MATLAB calculation. The software validation is done by comparing the code with experimental data or a widely tested code like the RELAP5 code. In addition, some PLTEMP/ANL V&V works that are available in the open literature are simply cited in Volume 1 of the document. PLTEMP/ANL has been used in the safety analysis reports of several US and foreign research reactors licensed and converted from highly enriched uranium fuel to low-enriched uranium fuel. A list of such reactors is given in Volume 1 of the document.