Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Screening of alkali-assisted storage conditions to define the operational window of deacetylation within storage systems in the bioenergy supply chain

Overcoming biomass heterogeneity and associated recalcitrance to thermal, chemical, and enzymatic depolymerization is a necessary but challenging aspect of valorizing lignocellulosic biomass to fuels and chemicals. Here, this study explores how this recalcitrance can be reduced during the supply chain unit operation of storage, which is required for seasonally harvested agricultural residues to maintain constant throughput at a biorefinery. In this work, partial alkali pretreatment was performed just prior to corn stover entering storage, which had the benefit of providing a high pH environment entering storage such that soluble sugars were preserved and saponified acetyl groups in hemicellulose. This work investigated a range of viable conditions where saponification and preservation occur simultaneously by varying the moisture content (40% and 60%) and concentrations of sodium hydroxide (low and high) during aerobic and anaerobic storage. Anaerobic conditions preserved overall dry matter below 5% in the three scenarios evaluated, and the highest alkali loading solubilized up to 15% lignin, 18% xylan, and 50% of acetate, meanwhile doubling the extractable components. Scanning electron microscopy images highlighted potential physical impacts including cell-wall disruption near vascular bundles, pitting within parenchyma cells, and cell-wall distortion. Techno-economic assessment indicated that this storage approach and associated logistics system is economically competitive with a conventional approach using low-moisture bales.

09 BIOMASS FUELS↗

Host-guest prospects of neodymium and gadolinium ultraphosphate frameworks for nuclear waste storage: Multi-temperature topological analysis of nanoporous cages in RP{sub 5}O{sub 14}

Highlights: • The temperature-dependent cage topologies of RP{sub 5}O{sub 14} (R = Nd or Gd) were examined. • A topological analysis revealed similar cage structure for RP{sub 5}O{sub 14} (R = Nd or Gd). • One exception: the 8/4 cage topology of NdP{sub 5}O{sub 14} lacks structural cross-linking. • Volume (UO{sub 2} or PuO{sub 2}) ≫ 8/4 topology in RP{sub 5}O{sub 14} (R = Nd or Gd). • RP{sub 5}O{sub 14} (R = Nd or Gd) are good prospective host media for nuclear waste storage. - Abstract: Rare-earth ultraphosphate (RP{sub 5}O{sub 14}) framework materials are potential host media for nuclear waste storage, since cages within their nanoporous structures have volumes that match well those of prospective guests such as uranium or plutonium ions. Good volume matches of host cages and guest compounds are nonetheless not the only structural requirement for ensuring viable nuclear waste storage. Host structures also need to be stable enough to withstand the typical environmental conditions of long-term storage of spent nuclear fuel. To this end, the nanoporous cage topologies of neodymium and gadolinium ultraphosphate, NdP{sub 5}O{sub 14} and GdP{sub 5}O{sub 14}, are investigated as a function of temperature. Topological analysis shows that, while both compounds are essentially isostructural, thus displaying the same type of cage structures, the cage volumes of NdP{sub 5}O{sub 14} are significantly larger than those of GdP{sub 5}O{sub 14}, with one stark exception. This exception concerns the cage of NdP{sub 5}O{sub 14} whose 8/4 topology lacks structural cross-linking that would otherwise give it much more strength. This 'squashed' cage appears to owe its origins to the specific nature of crystallographic twinning in NdP{sub 5}O{sub 14}, which causes strain that needs alleviating; squashing the 8/4 cage in NdP{sub 5}O{sub 14} would be the most susceptible option towards this end, since its cage manifests the weakest structural construct. GdP{sub 5}O{sub 14} succumbs to a gradual contraction of its 8/4 cage only with increasing temperature above 300 K; this is well below its second-order monoclinic-to-orthorhombic phase transition at 420–430 K; which is 420 K for NdP{sub 5}O{sub 14}. Fortunately, the volumes of heavy metal ions that arise from spent nuclear fuels do not match the size requirements of cages with 8/4 topology in RP{sub 5}O{sub 14} hosts needed for encapsulation; otherwise, radiation leakage of such containment would present a risk. Both NdP{sub 5}O{sub 14} and GdP{sub 5}O{sub 14} would therefore seem to offer good prospects as host media for nuclear waste storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Determining the profitability of energy storage over its life cycle using levelized cost of storage

Levelized cost of storage (LCOS) can be a simple, intuitive, and useful metric for determining whether a new energy storage plant would be profitable over its life cycle and to compare the cost of different energy storage technologies. However, researchers and industry decision makers still use conflicting definitions of LCOS. For example, some include charging cost, while others only include round trip efficiency (RTE) losses. Additionally, inputs to the existing formulations are not specific enough to generate repeatable results across studies, which reduces trust in the metric. To push for standardization in economic assessment of batteries and other energy storage devices, the authors review existing definitions of LCOS and identify the desired characteristics for a standard. They then propose a new definition and demonstrate that it fits these characteristics very well relative to other prominent options. Unit analysis is applied to this proposed definition to provide a deeper understanding of the equations and to demonstrate its effectiveness. Finally, the sensitivity of LCOS to different input parameters is investigated to help users understand how to compare analyses from literature to their own. The authors also provide a spreadsheet and a Python script to streamline adoption of the proposed definition.

25 ENERGY STORAGE↗

Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as an Innovative Energy Storage Technology for Fossil-Integrated Systems

Pumped-storage hydropower (PSH) provides around 95% of all utility-scale energy storage in the U.S. and globally. Additional deployment of PSH is hampered by excessively long permitting and commissioning requirements and is constrained to locations for which natural topography provides suitable elevation relief between the upper and lower reservoirs (the ΔH challenge). The purpose of this research was to evaluate Pumped-Storage Hydropower using Abandoned Underground Mines (PSH-AUM) as a means to solve the ΔH challenge and initiate the commercialization pathway for a promising new energy storage technology. Four primary tasks were conducted: Screening and ranking of candidate sites for project development; multiphase reservoir modeling to evaluate mine performance; techno-economic analysis and preliminary designs for PSH-AUM systems integrated with fossil-fuel power units; and stakeholder engagement to identify pathways to commercialization of this new technology. Key results were achieved in each of the four primary tasks. Candidate site screening determined that nearly 10,000 underground mines were spatially locatable, of which more than 100 sites appear suitable for integration with existing fossil power plants that are expected to remain in longer-term operation. Mine reservoir models were developed using PNNL’s STOMP simulator and parameterized using candidate site data to evaluate interactions with the surrounding groundwater system and confirm the potential for some mines to accommodate inflows and outflows on the order of 100 m3/s over 8-hour durations (1.6 GWh system) without excessive aqueous pressures. Techno-economic analysis resulted in a project cost optimization scheme to identify key sensitivities and the development of preliminary designs that can minimize overall costs of deployment. Finally, stakeholder engagement with industry, state government, and local economic development leaders confirmed the viability of PSH-AUM as a promising new technology. Our Phase I project results suggest that PSH-AUM technology has a domestic market potential on the order of $100+ Billion with ample space for technology development to commercialization within the next decade.

13 HYDRO ENERGY↗

The Influence of Hydraulic Fracturing on Carbon Storage Performance: Hydraulic Fracturing in Carbon Storage

We report that conventional principles of the design and operation of geologic carbon storage (GCS) require injecting CO 2 below the caprock fracturing pressure to ensure the integrity of the storage complex. In nonideal storage reservoirs with relatively low permeability, pressure buildup can lead to hydraulic fracturing of the reservoir and caprock. While the GCS community has generally viewed hydraulic fractures as a key risk to storage integrity, a carefully designed stimulation treatment under appropriate geologic conditions could provide improved injectivity while maintaining overall seal integrity. A vertically contained hydraulic fracture, either in the reservoir rock or extending a limited height into the caprock, provides an effective means to access reservoir volume far from the injection well. Employing a fully coupled numerical model of hydraulic fracturing, solid deformation, and matrix fluid flow, we study the enabling conditions, processes, and mechanisms of hydraulic fracturing during CO 2 injection. A hydraulic fracture's pressure-limiting behavior dictates that the near-well fluid pressure is only slightly higher than the fracturing pressure of the rock and is insensitive to injection rate and mechanical properties of the formation. Although a fracture contained solely within the reservoir rock with no caprock penetration, would be an ideal scenario, poroelastic principles dictate that sustaining such a fracture could lead to continuously increasing pressure until the caprock fractures. We also investigate the propagation pattern and injection pressure responses of a hydraulic fracture propagating in a caprock subjected to heterogeneous in situ stress. In conclusion, the results have important implications for the use of hydraulic fracturing as a tool for managing storage performance.

58 GEOSCIENCES↗

Interfacing HDF5 with a scalable object‐centric storage system on hierarchical storage

Summary Object storage technologies that take advantage of multitier storage on HPC systems are emerging. However, to use these technologies at present, applications have to be modified significantly from current I/O libraries. HDF5, a widely used I/O middleware on HPC systems, provides a virtual object layer (VOL) that allows applications to connect to different storage mechanisms transparently without requiring significant code modifications. We recently designed the proactive data containers (PDC) object‐centric storage system that provides the capabilities of transparent, asynchronous, and autonomous data movement taking advantage of multiple storage tiers—a decision that has so far been left upon the user on most current systems. To enable PDC's features through HDF5 without modifying application codes, we have developed an HDF5 VOL connector that interfaces with PDC. We present in this article the connector interface and evaluate its performance on Cori, a Cray XC40 supercomputer located at the National Energy Research Scientific Computing Center (NERSC). Our evaluation demonstrates up to an 8× improvement compared with HDF5 that has the most recent optimizations.

Mu, Jingqing↗

Ambient-Temperature Hydrogen Storage via Vanadium(II)-Dihydrogen Complexation in a Metal-Organic Framework

In this report, the widespread implementation of H 2 as a fuel is currently hindered by the high pressures or cryogenic temperatures required to achieve reasonable storage densities. In contrast, the realization of materials that strongly and reversibly adsorb hydrogen at ambient temperatures and moderate pressures could transform the transportation sector and expand adoption of fuel cells in other applications. To date, however, no adsorbent has been identified that exhibits a binding enthalpy within the optimal range of -15 to -25 kJ/mol for ambient-temperature hydrogen storage. Here, we report the hydrogen adsorption properties of the metal-organic framework (MOF) V 2 Cl 2.8 (btdd) (H 2 btdd, bis(1 H -1,2,3-triazolo[4,5- b ],[4',5'- i ])dibenzo[1,4]dioxin), which features exposed vanadium(II) sites capable of backbonding with weak π acids. Significantly, gas adsorption data reveal that this material binds H 2 with an enthalpy of -21 kJ/mol. This binding energy enables usable hydrogen capacities that exceed that of compressed storage under the same operating conditions. The Kubas-type vanadium(II)-dihydrogen complexation is characterized by a combination of techniques. From powder neutron diffraction data, a V-D 2 (centroid) distance of 1.966(8) Å is obtained, the shortest yet reported for a MOF. Using in situ infrared spectroscopy, the H-H stretch was identified, and it displays a red shift of 242 cm -1 . Electronic structure calculations show that a main contribution to bonding stems from the interaction between the vanadium d π and H 2 σ* orbital. Ultimately, the pursuit of MOFs containing high densities of weakly π-basic metal sites may enable storage capacities under ambient conditions that far surpass those accessible with compressed gas storage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO2 Saline Storage: Costs and Storage Capacity

This document provides a brief description of the current state of CO2 saline storage. It then discusses factors determining the cost of storage and provides examples for two storage formations. It concludes by discussing the factors influencing CO2 storage capacity and provides cost supply cirves for CO2 storage.

Morgan, David↗

Performance Modeling of Network-Attached Storage Device Based Hierarchical Mass Storage Systems

Network attached storage devices improve I/O performance by separating control and data paths and eliminating host intervention during the data transfer phase. Devices are attached to both a high speed network for data transfer and to a slower network for control messages. Hierarchical mass storage systems use disks to cache the most recently used files and a combination of robotic and manually mounted tapes to store the bulk of the files in the file system. This paper shows how queuing network models can be used to assess the performance of hierarchical mass storage systems that use network attached storage devices as opposed to host attached storage devices. Simulation was used to validate the model. The analytic model presented here can be used, among other things, to evaluate the protocols involved in 1/0 over network attached devices.

Menasce, Daniel A.↗

Developing CO 2 Source and Storage Opportunities across the Illinois Basin Subtask 5.3 – Regional Roadmap for Source Network and Storage Deployment Topical Report

Large-scale anthropogenic CO 2 sources (>100,000 tonnes/year) were catalogued for the CarbonSAFE Illinois East Sub-Basin carbon capture and storage pre-feasibility study. The source portfolio is diverse, consisting of fossil-base power production, ethanol production operations, chemical development, and refinery facilities, most of which are relatively new or modernized (i.e. post year 2000). Ten facilities were considered for potential commercial-scale geological storage in a regional CO 2 source and storage network study. The study area has a number of potential geologic sequestration targets, including three significant deep saline reservoirs with corresponding seals, and potential enhanced oil recovery (EOR) opportunities. Recent research has focused on a high-porosity, highly arkosic zone within the Lower Mt. Simon Sandstone. Based on this work, we present a conceptual CO 2 source and storage network, which focuses on the arkosic zone in the Lower Mt. Simon as a prospective storage resource play in the Illinois East Sub-Basin region.

01 COAL, LIGNITE, AND PEAT↗

Thermal energy storage apparatus, controllers and thermal energy storage control methods

Thermal energy storage apparatus, controllers and thermal energy storage control methods are described. According to one aspect, a thermal energy storage apparatus controller includes processing circuitry configured to access first information which is indicative of surpluses and deficiencies of electrical energy upon an electrical power system at a plurality of moments in time, access second information which is indicative of temperature of a thermal energy storage medium at a plurality of moments in time, and use the first and second information to control an amount of electrical energy which is utilized by a heating element to heat the thermal energy storage medium at a plurality of moments in time.

Hammerstrom, Donald J.↗

Anisotropic storage medium development in a full-scale, sodium alanate-based, hydrogen storage system

Deuterium desorption in an automotive-scale hydrogen storage tube was studied in-situ using neutron diffraction. Gradients in the concentration of the various alanate phases were observed along the length of the tube but no significant radial anisotropy was present. In addition, neutron radiography and computed tomography showed large scale cracks and density fluctuations, confirming the presence of these structures in an undisturbed storage system. These results demonstrate that large scale storage structures are not uniform even after many absorption/desorption cycles and that movement of gaseous hydrogen cannot be properly modeled by a simple porous bed model. In addition, the evidence indicates that there is slow transformation of species at one end of the tube indicating loss of catalyst functionality. These observations explain the unusually fast movement of hydrogen in a full scale system and shows that loss of capacity is not occurring uniformly in this type of hydrogen-storage system.

08 HYDROGEN↗