Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Heavy ion ranges from first-principles electron dynamics

The effects of incident energetic particles, and the modification of materials under irradiation, are governed by the mechanisms of energy losses of ions in matter. The complex processes affecting projectiles spanning many orders of magnitude in energy depend on both ion and electron interactions. Developing multi-scale modeling methods that correctly capture the relevant processes is crucial for predicting radiation effects in diverse conditions. Here, we obtain channeling ion ranges for tungsten, a prototypical heavy ion, by explicitly simulating ion trajectories with a method that takes into account both the nuclear and the electronic stopping power. The electronic stopping power of self-ion irradiated tungsten is obtained from first-principles time-dependent density functional theory (TDDFT). Although the TDDFT calculations predict a lower stopping power than SRIM by a factor of three, our result shows very good agreement in a direct comparison with ion range experiments. These results introduce the validity of the TDDFT approach for determining electronic energy losses of heavy projectiles, and in turn its viability for the study of radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MeV Au Ion Irradiation in Silicon and Nanocrystalline Zirconia Film Deposited on Silicon Substrate

Nanocrystalline zirconia (ZrO2) film with thickness of 305 nm deposited on a silicon substrate was irradiated with 2 MeV Au ions to different fluences at different temperatures. The implanted ion profiles were measured by time-of-flight secondary ion mass spectrometry (ToF-SIMS) and simulated using the stopping and range of ions inmatter (SRIM) code, respectively. The experimental results show that a large fraction of the incident Au ions penetrates through the ZrO2 film and are deposited into the Si substrate. At the interface of ZrO2 and Si, a sudden decrease of Au concentration is observed due to the much larger scattering cross section of Au in ZrO2 than in Si. The depth profile of the Au ions is measured in both the ZrO2 films and the Si substrates, and the results show that the Au distribution profiles do not exhibit a dependence on irradiation temperature. The local Au concentration increases proportionally with the irradiation fluence, suggesting that no thermal or irradiation-induced redistribution of the implanted Au ions. However, the Au concentration in the ZrO2 films, as determined by SIMS, is considerably lower than that predicted by the SRIM results, and the penetration depth from the SIMS measurements is much deeper than that from the SRIM predictions. These observations can be explained by an overestimation of the electronic stopping power, used in the SRIM program, for heavy incident ions in light targets. Over-estimation of the heavy-ion electronic stopping power may lead to errors in local dose calculation and underestimation of the projected range of slow heavy ions in targets that contain light elements. A quick estimate based on a reduced target density may be used to compensate the overestimation of the electronic stopping power in the SRIM program to provide better ion profile prediction.

Environmental Molecular Sciences Laboratory↗

SU-C-201-07: Towards Clinical Cherenkov Emission Dosimetry: Stopping Power-To-Cherenkov Power Ratios and Beam Quality Specification of Clinical Electron Beams

Purpose: We propose a Cherenkov emission (CE)-based reference dosimetry method, which in contrast to ionization chamber-based dosimetry, employs spectrum-averaged electron restricted mass collision stopping power-to-Cherenkov power ratios (SCRs), and we examine Monte Carlo-calculated SCRs and beam quality specification of clinical electron beams. Methods: The EGSnrc user code SPRRZnrc was modified to compute SCRs instead of stopping-power ratios (single medium: water; cut-off: CE threshold (observing Spencer-Attix conditions); CE power: Frank-Tamm). SCRs are calculated with BEAMnrc for realistic electron beams with nominal energies of 6–22 MeV from three Varian accelerators (TrueBeam Clinac 21EX, Clinac 2100C/D) and for mono-energetic beams of energies equal to the mean electron energy at the water surface. Sources of deviation between clinical and mono-energetic SCRs are analyzed quantitatively. A universal fit for the beam-quality index R{sub 50} in terms of the depth of 50% CE C{sub 50} is carried out. Results: SCRs at reference depth are overestimated by mono-energetic values by up to 0.2% for a 6-MeV beam and underestimated by up to 2.3% for a 22-MeV beam. The variation is mainly due to the clinical beam spectrum and photon contamination. Beam angular spread has a small effect across all depths and energies. The influence of the electron spectrum becomes increasingly significant at large depths, while at shallow depths and high beam energies photon contamination is predominant (up to 2.0%). The universal data fit reveals a strong linear correlation between R{sub 50} and C{sub 50} (ρ > 0.99999). Conclusion: CE is inherent to radiotherapy beams and can be detected outside the beam with available optical technologies, which makes it an ideal candidate for out-of-beam high-resolution 3D dosimetry. Successful clinical implementation of CE dosimetry hinges on the development of robust protocols for converting measured CE to radiation dose. Our findings constitute a key step towards clinical CE dosimetry.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 04: Stopping power-to-Cherenkov power ratios and beam quality specification for clinical Cherenkov emission dosimetry of electrons: beam-specific effects and experimental validation

Purpose: To advance towards clinical Cherenkov emission (CE)-based dosimetry by investigating beam-specific effects on Monte Carlo-calculated electron-beam stopping power-to-CE power ratios (SCRs), addressing electron beam quality specification in terms of CE, and validating simulations with measurements. Methods: The EGSnrc user code SPRRZnrc, used to calculate Spencer-Attix stopping-power ratios, was modified to instead calculate SCRs. SCRs were calculated for 6- to 22-MeV clinical electron beams from Varian TrueBeam, Clinac 21EX, and Clinac 2100C/D accelerators. Experiments were performed with a 20-MeV electron beam from a Varian TrueBeam accelerator, using a diffraction grating spectrometer with optical fiber input and a cooled back-illuminated CCD. A fluorophore was dissolved in the water to remove CE signal anisotropy. Results: It was found that angular spread of the incident beam has little effect on the SCR (≤ 0.3% at d{sub max}), while both the electron spectrum and photon contamination increase the SCR at shallow depths and decrease it at large depths. A universal data fit of R{sub 50} in terms of C{sub 50} (50% CE depth) revealed a strong linear dependence (R{sup 2} > 0.9999). The SCR was fit with a Burns-type equation (R{sup 2} = 0.9974, NRMSD = 0.5%). Below-threshold incident radiation was found to have minimal effect on beam quality specification (< 0.1%). Experiments and simulations were in good agreement. Conclusions: Our findings confirm the feasibility of the proposed CE dosimetry method, contingent on computation of SCRs from additional accelerators and on further experimental validation. This work constitutes an important step towards clinical high-resolution out-of-beam CE dosimetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Thick Target Neutron Yield Calculations for Alphas on F-19 using MCNP6 1.1 Beta with TENDL 2012 Libraries

Because of the heritage of MCNPX, the first production release of MCNP6{sup TM} used physics models, instead of ACE (A Compact Evaluated Nuclear Data File) formatted libraries, for simulating the transport of alpha particles at all energies, as MCNPX could not yet read ACE formatted light ion libraries. For non-Coulombic interactions, the physics models have suggested minimums of ∼ 20-200 MeV. The first production release of MCNP6, MCNP6{sup TM} 1.0, was still capable of transporting alphas to low energies; however, the physics models resulted in poor prediction of inelastic reactions at energies below the suggested minimums. This poorer prediction at low energies resulted in orders of magnitude lower neutron yields for events resulting from light ion interactions at low energies. For example, F-19(α,n)Na-22 from U-234 decay in UF{sub 6} produced poor neutron production results. Modeling these types of interactions correctly is vital for signal analysis for nonproliferation safeguards and nuclear security as well as for correctly characterizing source terms for radiation protection and shielding calculations. The TALYS computer code was developed to simulate nuclear reactions involving neutrons, photons, protons, deuterons, tritons, alphas and He-3 particles, in the 1 keV - 200 MeV energy range. TENDL is a nuclear data library, which provides the output of the TALYS nuclear model code system for direct use in applications (i.e. ACE formatted cross sections). Since 2008, TENDL had publicly provided ACE formatted libraries for alpha transport; however, not until the release of MCNP6{sup TM} 1.1 beta, had MCNP6 publicly possessed the capability to read such libraries. At the Radiation Protection and Shielding Division topical meeting in 2014, initial testing of MCNP6 1.1 beta showed that MCNP6 using TENDL 2012 resulted in poor prediction when compared to the compilation of experiment data provided in R. Heaton et al. Further comparisons for PuBe sources, using the MCNP6 1.1 beta spontaneous decay alpha feature coupled with alpha transport, were also given in the winter American Nuclear Society meeting in 2014, where the results showed large discrepancies with measured data. For F-19(α,n)Na-22 interactions, the R. Heaton et al. paper is a conglomeration of several important references; and the data provided by R. Heaton et al. used a numerical fit of the excitation function provided by Norman et al.. Norman et al. has recently published their (α,n) thick target yield data for PbF{sub 2} in tabular form, backing out the thick target yields of F-19(α,n)Na-22 and computing F{sub 2} and UF{sub 6} thick target neutron yields (as supplements to the PbF{sub 2} data). Here we compared measured thick target yields of E. B. Norman et al. to MCNP6 1.1 beta using TENDL 2012 libraries. Deterministically backing out the thick target yield from measured values involves using the stopping power. MCNP uses either the SPAR code or an interpolation of the Spar code and Bethe-Boch formula for computing stopping powers. As a result one may believe that these separate methods will arrive at separate thick target yields independent of the production cross section. In our MCNP calculations, we simulated the alpha until the alpha completely stopped in the medium. The energy loss in the condensed history algorithm is not continuous but discrete and related to the stopping powers. Because the neutron production yield is energy dependent, the energy loss dictates the emission of secondary neutrons; and therefore the difference in stopping powers used may have some slight effect on the yield difference. For this study, we chose to use the default condensed history algorithm setup, while future studies should address tightening steps in the condensed history algorithm to prove whether or not choice of stopping power actually matters. The fact that all 5 evaluated isotopic compositions resulted in different thick target yield percent differences does warrant this type of investigation. A typical user may not be only interested in integral emission, taking 10 s to 100 s of processor hours to simulate, but rather a timely generation of the spectra. Such an application would require biasing the production of secondaries from alpha sources such that millions of secondaries could be produced, emulating a converged energy dependent spectra. Neutron production biasing from alpha sources does not currently exist; however, developing a biasing algorithm for neutron production from alpha sources should be investigated in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-TeP2-13: Patient-Specific Reduction of Range Uncertainties in Proton Therapy by Proton Radiography with a Multi-Layer Ionization Chamber

Purpose: The conversion from Hounsfield units (HU) to stopping powers is a major source of range uncertainty in proton therapy (PT). Our contribution shows how proton radiographs (PR) acquired with a multi-layer ionization chamber in a PT center can be used for accurate patient positioning and subsequently for patient-specific optimization of the conversion from HU to stopping powers. Methods: A multi-layer ionization chamber was used to measure the integral depth-dose (IDD) of 220 MeV pencil beam spots passing through several anthropomorphic phantoms. The whole area of interest was imaged by repositioning the couch and by acquiring a 45×45 mm{sup 2} frame for each position. A rigid registration algorithm was implemented to correct the positioning error between the proton radiographs and the planning CT. After registration, the stopping power map obtained from the planning CT with the calibration curve of the treatment planning system was used together with the water equivalent thickness gained from two proton radiographs to generate a phantom-specific stopping power map. Results: Our results show that it is possible to make a registration with submillimeter accuracy from proton radiography obtained by sending beamlets separated by more than 1 mm. This was made possible by the complex shape of the IDD due to the presence of lateral heterogeneities along the path of the beam. Submillimeter positioning was still possible with a 5 mm spot spacing. Phantom specific stopping power maps obtained by minimizing the range error were cross-verified by the acquisition of an additional proton radiography where the phantom was positioned in a random but known manner. Conclusion: Our results indicate that a CT-PR registration algorithm together with range-error based optimization can be used to produce a patient-specific stopping power map. Sylvain Deffet reports financial funding of its PhD thesis by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work. Francois Vander Stappen reports being employed by Ion Beam Applications (IBA) during the confines of the study and outside the submitted work.

60 APPLIED LIFE SCIENCES↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗