Sterilization requirements, operational procedures, facilities and hardware.
Space vehicle sterilization and decontamination, discussing dry heat sterilization and Capsule System Advanced Development
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Space vehicle sterilization and decontamination, discussing dry heat sterilization and Capsule System Advanced Development
Technical report on the effects of sterilization on the energy-dissipating properties of balsa wood is given. Sterilization by ethylene oxide plus heat enhances the average specific energy of balsa while plastic impregnation followed by irradiation-induced polymerization does not.
Bacillus test organisms, microbe survival studies, and sterility certification for Mars landing capsule sterilization container
Technique for sterile insertion of liquids into previously sterilized spacecraft
Ethylene oxide sterilization and encapsulating process for sterile preservation of instruments and solid propellants
A body encountering the atmosphere of an outer planet is subjected to heat loads which could result in high temperature conditions that render terrestrial organisms on or within the body nonviable. To determine whether an irregularly shaped entering body, consisting of several different materials, would be sterilized during inadvertent entry at high velocity, the thermal response of a typical outer planet spacecraft instrument was studied. The results indicate that the Teflon insulated cable and electronic circuit boards may not experience sterilizing temperatures during a Jupiter, Saturn, or Titan entry. Another conclusion of the study is that small plastic particles entering Saturn from outer space have wider survival corridors than do those at Jupiter.
A study was conducted: to identify those experiments that could and should be done on a returned Martian sample in order to characterize its inorganic properties; to evaluate, insofar as can be done, the effects of potential biological sterilization of the sample by heating prior to its return; to identify particular analytical techniques needing further improvement in order to make optimum use of a returned sample; and to identify experiments to be done on simulants, with and without sterilization, that better define the limits of information available about the planet from analyses of returned samples.
As a body encounters the atmosphere of an outer planet, whether accidentally or by plan, it will be subjected to heat loads which could result in high temperature conditions that render terrestrial organisms on or within the body non-viable. To determine whether an irregularly shaped entering body, consisting of several different materials, would be sterilized during inadvertent entry at high velocity, the thermal response of a typical outer planet spacecraft instrument was studied. The results indicate that the Teflon-insulated cable and electronic circuit boards may not experience sterilizing temperatures during a Jupiter, Saturn, or Titan entry. Another conclusion of the study is that small plastic particles entering Saturn from outer space have wider survival corridors than do those at Jupiter.
Canister, originally conceived for remote sterilization of spacecraft packages, could be used terrestrially to handle samples in biologically hazardous environments. Multiwalled canister includes inner layer of pyrotechnic powder. For sterilization, electrically activated squib ignites powder, raising temperature of outer surface of canister to 230 degrees centigrade for several minutes. Thermal-buffer inner layer prevents inside temperature for exceeding 100 degrees centigrade to protect contents from damage. Samples in field hospitals and other emergency situations could also be handled by equipment.
Continuous sterilization of plumbing, such as in hospitals, clinics, and biological testing laboratories is possible with ethylene oxide/Freon 12 (ETO/F-12) humidifier developed for sterilization of potable water systems.
The effect of sterilization gamma irradiation on the friction and wear properties of ultrahigh molecular weight polyethylene (UHMWPE) sliding against 316L stainless steel in dry air at 23 C was determined. A pin-on-disk apparatus was used. Experimental conditions included a 1-kilogram load, a 0.061- to 0.27-meter-per-second sliding velocity, and a 32000- to 578000-meter sliding distance. Although sterilization doses of 2.5 and 5.0 megarads greatly altered the average molecular weight and the molecular weight distribution, the friction and wear properties of the polymer were not significantly changed.
Since the 1976 Viking Mission to Mars, follow-on efforts to resolve its controversial life detection results have been thwarted by two heretofore insurmountable difficulties: the huge expense of sterilizing the entire spacecraft to protect the integrity of life detection experiments; and the lack of a practical robotic life detection package that could produce results acceptable as unambiguous by the scientific community. We here present a method that assures sterility and the complete integrity of robotic life detection experiments, all at a negligible cost. Second, we propose a candidate set of integrated, highly sensitive experiments that we believe could produce results acceptable to the vast majority of scientists. In addition to the biology-chemistry issue, the extensively debated oxidative state of the Martian surface and other chemical and physical characteristics of the Martian soil would be determined. We present our concept for a miniaturized instrument that could carry out a number of candidate experiments to achieve the objective.
The United States is about to embark on an ambitious program of Lunar and Space Exploration. This program will not only serve the needs of the national and international scientific community but will also enhance the prestige of the United States in the eyes of the peoples of the world.There are many problems associated with such pioneering investigations, among which is included the effecting of adequate safe- guards against biological contamination of celestial bodies with ter- restrial microorganisms. In the not too distant future, the reverse problem of preventing contamination of our terrestrial body with extraterrestrial microorganisms must be considered. In order to determine the current status of decontamination and sterilization procedures and to arrive at areas of research required in order to increase the knowledge in this field, the NASA sponsored a meeting at which time this problem was discussed. Invitations to attend this meeting were extended to agencies actively concerned with the development of spacecraft and launch vehicles as well as those groups involved in the investigation and development of decontamination and sterilization techniques. The meeting was held in Washington, D, C. on June 29, 1960. The recorded minutes of this meeting, which have been edited, are included in this paper, as well as a listing of recommendations resulting from the deliberations.
A relatively low-temperature process for dehydrating and sterilizing biohazardous wastes in an enclosed life-support system exploits (1) the superior mass-transport properties of supercritical fluids in general and (2) the demonstrated sterilizing property of supercritical CO2 in particular. The wastes to be treated are placed in a chamber. Liquid CO2, drawn from storage at a pressure of 850 psi (approx.=5.9 MPa) and temperature of 0 C, is compressed to pressure of 2 kpsi (approx.=14 MPa) and made to flow into the chamber. The compression raises the temperature to 10 C. The chamber and its contents are then further heated to 40 C, putting the CO2 into a supercritical state, in which it kills microorganisms in the chamber. Carrying dissolved water, the CO2 leaves the chamber through a back-pressure regulator, through which it is expanded back to the storage pressure. The expanded CO2 is refrigerated to extract the dissolved water as ice, and is then returned to the storage tank at 0 C
There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.
The potential to return Martian samples to Earth for extensive analysis is in great interest of the planetary science community. It is important to make sure the mission would securely contain any microbes that may possibly exist on Mars so that they would not be able to cause any adverse effects on Earth's environment. A brazing sealing and sterilizing technique has been proposed to break the Mars-to-Earth contamination chain. Thermal analysis of the brazing process was conducted for several conceptual designs that apply the technique. Control of the increase of the temperature of the Martian samples is a challenge. The temperature profiles of the Martian samples being sealed in the container were predicted by finite element thermal models. The results show that the sealing and sterilization process can be controlled such that the samples' temperature is maintained below the potentially required level, and that the brazing technique is a feasible approach to break the contamination chain.
For a variety of medical and scientific reasons, human bones can be exposed to ionizing radiation. At relatively high doses (30,000±5,000 Gy), ex vivo ionizing radiation is commonly used to sterilize bone allografts. However, ionizing radiation in these applications has been shown to increase risk of fracture clinically and decrease bone quality. Previously, we observed a significant decrease in compressive static strength and fatigue life of ex vivo whole bones exposed to x-ray radiation at 17,000 Gy and above; no changes in compressive mechanical properties were observed for radiation doses of 1,000 Gy and below. The gap in doses between no mechanical change (1,000 Gy) and significant mechanical degradation (17,000 Gy) is large, and it is unclear at what dose mechanical integrity begins to diminish in whole bones, and if its effects differ in response to static versus cyclic mechanical loading. This is a major clinical concern, as trabecular and cortical bone allografts are commonly used in structural, load-bearing applications. To gain insight into the effect of ionizing radiation from 1,000-17,000 Gy, we conducted an ex vivo radiation study on the static and fatigue mechanical properties of the vertebral whole bone. Our objectives were to: (1) quantify the effect of exposure to ex vivo ionizing radiation on the mechanical integrity (compressive static and fatigue) of whole bones; and (2) evaluate, if there are observed differences in mechanics, if they differ in magnitude for static versus cyclic properties. The results of this study will give insight into the need for changes in protocols for bone allograft radiation sterilization procedures.
The potential return of samples back to Earth from other planetary bodies would be based on planetary protection requirements that vary depending on the type of body [1]. Potential Mars Sample Return would require the protection of our planet from backward contamination. To fulfill this requirement, it would be necessary to implement “break the chain of contact (BTC)” process, where any material reaching Earth would have to be inside a container that is sealed with an extremely high level of confidence. In order to accomplish this, it would be necessary to contain the acquired samples and destroy any potential biological materials that may have contaminated the external surface of the container, while protecting the samples for further analysis. Using brazing, a novel synchronous separation, seaming, sealing and sterilization (S4) process for sample containerization and planetary protection has been conceived and demonstrated. A prototype double-wall container with inner and outer shells and Earth clean interstitial space was used for this demonstration. For potential Mars sample return, the double wall container would be consist of two halves and prepared on Earth. The on-orbit execution would consist of inserting the sample into one of the halves and then mating to the other half and melt the braze material to perform the S4 process. The use of brazing material that melts at temperatures higher than 500OC would assure sterilization of the exposed areas due to pyrolysis since carbon bonds are broken at this temperature. The process consists of two-steps, Step-1: the double wall container halves are fabricated and brazed on Earth; and Step-2: Assembly and brazing the samples on orbit. To prevent potential jamming during the process of mating the two halves of the double-wall container and the extraction of the brazed inner container, a double cone-within-cone approach has been conceived. The results of this study are described and discussed in this manuscript.