Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

135 records · Page 8

Variable-Depth Liner Evaluation Using Two NASA Flow Ducts

Four liners are investigated experimentally via tests in the NASA Langley Grazing Flow Impedance Tube. These include an axially-segmented liner and three liners that use reordering of the chambers. Chamber reordering is shown to have a strong effect on the axial sound pressure level profiles, but a limited effect on the overall attenuation. It is also shown that bent chambers can be used to reduce the liner depth with minimal effects on the attenuation. A numerical study is also conducted to explore the effects of a planar and three higher-order mode sources based on the NASA Langley Curved Duct Test Rig geometry. A four-segment liner is designed using the NASA Langley CDL code with a Python-based optimizer. Five additional liner designs, four with rearrangements of the first liner segments and one with a redistribution of the individual chambers, are evaluated for each of the four sources. The liner configuration affects the sound pressure level profile much more than the attenuation spectra for the planar and first two higher-order mode sources, but has a much larger effect on the SPL profiles and attenuation spectra for the last higher-order mode source. Overall, axially variable-depth liners offer the potential to provide improved fan noise reduction, regardless of whether the axially variable depths are achieved via a distributed array of chambers (depths vary from chamber to chamber) or a group of zones (groups of chambers for which the depth is constant).

Jones, M. G.↗

TPSAS-NF1676L-12833-DND

A field test on a 3-microphone array at NASA Langley Research Center was conducted using a mobile controlled infrasonic source. A Helmholtz resonator, used to provide a simulated point source for infrasonic propagation studies, had an output SPL of 99 dB (at 1 m) at its resonance frequency of 9.45 Hz. The 3-microphone array was arranged as an equilateral triangle with microphones spacing of 30.48 m (100 ft) and at a distance of more than 85.3 m (280 ft) from the source. The signal level was 40 dB above the background noise in a 1-Hz band. Measurements of the acoustical response for each of the array microphones were recorded and the received signal was measured at the nearest microphone to be 60 dB (6 dB per doubling of distance).

Qamar A Shams↗

Estimating the Noise Floor of Sonic Boom Metrics Across the USA

NASA is building the X-59 Quiet Supersonic Technology aircraft to produce low noise sonic booms for a series of community noise surveys across the USA. Survey participants will rate their perception of the low booms from supersonic X-59 flyovers. Several noise metrics are proposed to quantify the noise dose: A-, B-, D-, E-weighted Sound Exposure Level, Stevens Perceived Level, and Indoor Sonic Boom Annoyance Predictor. Sparse measurements across the survey area will be used to estimate community noise exposure. The level of these low booms may be comparable to the ambient noise level in some locations, leading to uncertainty in noise exposure estimations. This uncertainty may necessitate increased reliance on sonic boom propagation predictions for exposure estimation. Low-boom signal to ambient noise ratio is one way to quantify uncertainty in measured sonic boom levels. An empirical relationship between A-weighted ambient level and sonic boom metric levels is used in conjunction with the National Park Service’s L50 SPL map to estimate sonic boom metric ambient levels across the USA. The estimate of ambient sonic boom metric levels will aid in X-59 test planning and execution.

sonic boom↗

Estimated Ambient Sonic Boom Metric Levels and X-59 Signal-to-Noise Ratios across the USA

NASA is building the X-59 Quiet Supersonic Technology aircraft to produce low noise sonic booms for a series of community noise surveys across the USA. Survey participants will rate their perception of the low-booms from supersonic X-59 flyovers. Several noise metrics are proposed to quantify the noise dose: A-, B-, D-, and E-weighted Sound Exposure Level, Stevens Perceived Level, and Indoor Sonic Boom Annoyance Predictor. Sparse measurements across the survey area will be used to estimate community noise exposure. The level of these low-booms may be comparable to the ambient noise level in some locations, leading to uncertainty in noise exposure estimations. This uncertainty may necessitate increased reliance on sonic boom propagation predictions for exposure estimation. Low-boom signal to ambient noise ratio is one way to quantify uncertainty in measured sonic boom levels. An empirical relationship between A-weighted ambient level and sonic boom metric levels is used in conjunction with the National Park Service’s L50 SPL map to estimate ambient noise levels expressed in terms of sonic boom noise metrics across the USA. These estimates of ambient levels will aid in X-59 community test planning and execution. The signal-to-noise ratio for the undertrack X-59 sonic boom is also estimated, and an example application of these data is presented for comparing potential noise monitor sites prior to a community noise test.

X-59↗

High Intensity Modal Impedance Tube Development at NASA Langley

A High Intensity Modal Impedance Tube (HIMIT) was developed for evaluation of acoustic liners in a normal incidence, high sound pressure level (SPL), and high frequency environment. Capabilities of the HIMIT are demonstrated here by testing three classes of acoustic liners: a narrow chamber liner, conventional single degree of freedom liners, and over-the-rotor liners. The experimental results are compared to results in NASA Langley's Normal Incidence Tube (NIT) for validation. The Zwikker and Kosten Transmission Line (ZKTL) model is also compared to the HIMIT results for selected configurations to study its applicability at high SPLs and frequencies. The HIMIT and NIT impedance spectra compare favorably up to 3.0 kHz, which is the upper frequency limit of the NIT analysis. The ZKTL model was used at frequencies up to 6.0 kHz and showed great comparison for the entire frequency range tested, indicating that the model may be used at high frequencies when the plane wave mode is dominant.

Chelsea Solano↗

Toward Fully 3D-Printed Two Degree of Freedom Acoustic Liners

An acoustic liner optimization tool is developed for designing two degree of freedom (2DOF) liners with high absorption over a wide range of frequencies and sound pressure levels (SPLs). Two additively manufactured 2DOF liners (one constant and one variable chamber depth) are designed and printed with an embedded perforate layer as the septum. A normal incidence impedance tube study is performed to directly compare impedance and absorption spectra to a more traditionally manufactured 2DOF liner with embedded mesh caps in phenolic honeycomb. Comparisons of test data to predictions are shown as well as SPL sensitivities for each acoustic liner. Broadband absorption is achieved with the 3D printed 2DOF liner containing constant chamber depths, although due to current limitations in printed embedded perforate hole size, not as broad as the traditional mesh cap liner. However, results also show that the 3D printed variable chamber depth sample is more comparable to the mesh cap liner absorption, demonstrating the viability of printed embedded perforates in novel concepts.

acoustic liner 2DOF two degree of freedom 3D print↗

Intern Poster Session 08/13: Autonomous Nuclear Robotics: Applications in nuclear waste inspection and hot cell experiments

The nuclear industry is experiencing renewed interest in autonomous robotics, yet most deployed systems remain teleoperated with limited autonomy. This work presents two contributions toward fully autonomous nuclear robotic systems: autonomous waste inspection at the Hanford Site and an autonomous hot cell laboratory framework. Inspections of Hanford's underground waste storage tanks are performed manually at significant cost and personnel exposure. We developed a reinforcement-learning (RL) training pipeline for a custom-built inspection arm. In parallel, we are designing an autonomous laboratory framework for post-irradiation examination in hot cells at the Specimen Preparation Laboratory (SPL) that integrates computer vision, task and motion planning, hardware execution, and operator-in-the-loop control. These systems demonstrate a path toward safer, more efficient nuclear operations by reducing human exposure while maintaining rigorous human oversight at critical decision points.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Smart Home Test Bed: Examining How Smart Homes Interact with the Power Grid

This fact sheet highlights the Smart Home Test Bed capability at the Energy Systems Integration Facility. The National Renewable Energy Laboratory (NREL) is working on one of the new frontiers of smart home research: finding ways for smart home technologies and systems to enhance grid operations in the presence of distributed, clean energy technologies such as photovoltaics (PV). To help advance this research, NREL has developed a controllable, flexible, and fully integrated Smart Home Test Bed.

24 POWER TRANSMISSION AND DISTRIBUTION↗