Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTRAL EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Infrared spectroscopy (2.3-20 microns) for the geological interpretation of remotely-sensed multispectral thermal infrared data

The spectral radiance and spectral reflectance of natural weathered surfaces of common sedimentary and igneous rocks is determined from in situ and in the laboratory measurements. In situ spectral radiance measurements (5-14 microns) were made with a portable spectral radiometer and were used to derive the spectral emissivity of the rocks. The spectral reflectance measurements (2.3-20 microns) were made in a laboratory with a Fourier transform IR spectrometer with a diffuse reflectance accessory. Good agreement is found between the two techniques. The field portable spectrometer has a larger field of view and the in situ data provide more accurate measurements of the intensity of spectral features related to temperature and atmospheric effects.

Bartholomew, Mary Jane↗

Feasibility Investigation for Performing Fireball Temperature Tests

NASA Johnson Space Center White Sands Test Facility (WSTF) was requested by the Launch Abort Subpanel and the Power Systems Subpanel of the Interagency Nuclear Safety Review Panel to investigate the feasibility of using spectroscopic techniques to measure propellant fireball gas temperatures. This report outlines the modeling and experimental approaches and results of this investigation. Descriptions of the theoretical particle temperature and mass effusion models are presented along with the results of the survivability of small plutonium dioxide (less than or equal to 1000 microns diameter) particles entrained in various propellant fireball scenarios. The experimental test systems used to measure the hydroxide radical, water, and particle graybody spectral emissions and absorptions are discussed. Spectral results along with temperatures extracted by analyzing the spectral features are presented for the flames investigated in the laboratory environment. Methods of implementing spectroscopic measurements for future testing using the WSTF Large-scale Hydrogen/Oxygen Explosion Facility are discussed, and the accuracy expected for these measurements is estimated from laboratory measurements.

Tapphorn, Ralph M.↗

DERIVING PLASMA DENSITIES AND ELEMENTAL ABUNDANCES FROM SERTS DIFFERENTIAL EMISSION MEASURE ANALYSIS

We use high-resolution spectral emission line data obtained by the SERTS instrument during three rocket flights to demonstrate a new approach for constraining electron densities of solar active region plasma. We apply differential emission measure (DEM) forward-fitting techniques to characterize the multithermal solar plasma producing the observed EUV spectra, with constraints on the high-temperature plasma from the Yohkoh Soft X-ray Telescope. In this iterative process, we compare line intensities predicted by an input source distribution to observed line intensities for multiple iron ion species, and search a broad range of densities to optimize {chi}{sup 2} simultaneously for the many available density-sensitive lines. This produces a density weighted by the DEM, which appears to be useful for characterizing the bulk of the emitting plasma over a significant range of temperature. This 'DEM-weighted density' technique is complementary to the use of density-sensitive line ratios and less affected by uncertainties in atomic data and ionization fraction for any specific line. Once the DEM shape and the DEM-weighted density have been established from the iron lines, the relative elemental abundances can be determined for other lines in the spectrum. We have also identified spectral lines in the SERTS wavelength range that may be problematic.

79 ASTRONOMY AND ASTROPHYSICS↗

Deriving Plasma Densities and Elemental Abundances from SERTS Differential Emission Measure Analysis

We use high-resolution spectral emission line data obtained by the SERTS instrument during three rocket flights to demonstrate a new approach for constraining electron densities of solar active region plasma.We apply differential emission measure (DEM) forward-fitting techniques to characterize the multithermal solar plasma producing the observed EUV spectra, with constraints on the high-temperature plasma from the Yohkoh Soft X-ray Telescope. In this iterative process, we compare line intensities predicted by an input source distribution to observed line intensities for multiple iron ion species, and search a broad range of densities to optimize chi-square simultaneously for the many available density-sensitive lines. This produces a density weighted by the DEM, which appears to be useful for characterizing the bulk of the emitting plasma over a significant range of temperature. This "DEM-weighted density" technique is complementary to the use of density-sensitive line ratios and less affected by uncertainties in atomic data and ionization fraction for any specific line. Once the DEM shape and the DEM-weighted density have been established from the iron lines, the relative elemental abundances can be determined for other lines in the spectrum. We have also identified spectral lines in the SERTS wavelength range that may be problematic

corona↗

BLACK RADIATION DETECTOR

Efficiency of conical calorimeter for detecting black body radiation, based on spectral emissivity and reflectance measurements

SPECTRAL EMISSION↗

Emission polarization study on quartz and calcite.

Calculation of the spectral emission polarization of quartz and calcite polished plates for observation angles of 20 and 70 deg by the substitution of complex index of refraction values for each mineral into Fresnel's equations. The emission polarization is shown to be quite wavelength-dependent, demonstrating that selected narrow or medium-width spectral bands exhibit a significantly higher percentage of polarization than a broad spectral band for these two minerals. Field measurements with a broadband infrared radiometer yield polarizations on the order of 2% for a coarse-grained granite rock and beach sand (both quartz-rich). This implies that a more sensitive detector with a selected medium-width filter may be capable of measuring emission polarization accurately enough to make this parameter useful as a remote sensing tool for discrimination among rocks on the basis of texture.

Vincent, R. K.↗

Optical Emission of Dusty RF Discharges: Experiment and Simulation

The spectral emission of argon atoms in a dusty radio frequence (RF) discharge has been investigated experimentally and in simulations. It was observed that the spatially and temporally resolved emission of the argon atoms in the dusty discharge was increased compared to the dust-free case during sheath expansion. The corresponding simulations have revealed that the dust trapped in the sheath of the discharge leads to a small, but important, increase of the amount of high-energy electrons that in turn leads to an increased argon emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase-resolved optical emission of dusty rf discharges: Experiment and simulation

The spectral emission of atoms in a dusty radio frequence (rf) discharge plasma in argon and helium has been measured with a gated ICCD camera. The spatially and temporally resolved emission/excitation of the argon and helium atoms during the rf cycle in the dusty discharge was compared to the dust-free case. In the bulk plasma above the dust cloud, the emission is clearly enhanced in the dusty discharge with respect to the pure discharge, whereas in the sheath the emission is reduced. In addition, the emission of a dusty argon plasma is studied via particle-particle particle-mesh (P{sup 3}M) simulations. The rf dynamics with a single dust particle trapped in the sheath was calculated. Like in the experiment the dust modifies the atomic emission. The spatiotemporal excitation pattern of the experiment is reproduced and a detailed understanding of the difference in excitation of the discharge with and without dust is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring Surface Climate With its Emissivity Derived From Satellite Measurements

Satellite thermal infrared (IR) spectral emissivity data have been shown to be significant for atmospheric research and monitoring the Earth fs environment. Long-term and large-scale observations needed for global monitoring and research can be supplied by satellite-based remote sensing. Presented here is the global surface IR emissivity data retrieved from the last 5 years of Infrared Atmospheric Sounding Interferometer (IASI) measurements observed from the MetOp-A satellite. Monthly mean surface properties (i.e., skin temperature T(sub s) and emissivity spectra epsilon(sub v) with a spatial resolution of 0.5x0.5-degrees latitude-longitude are produced to monitor seasonal and inter-annual variations. We demonstrate that surface epsilon(sub v) and T(sub s) retrieved with IASI measurements can be used to assist in monitoring surface weather and surface climate change. Surface epsilon(sub v) together with T(sub s) from current and future operational satellites can be utilized as a means of long-term and large-scale monitoring of Earth 's surface weather environment and associated changes.

Zhou, Daniel K.↗

Establishing temperature from radiance of dynamically compressed metals

Precise temperature determination is a significant challenge in extreme environments of dynamic compression studies. How can radiance measurements taken in high-pressure shock experiments constrain temperature in a meaningful and physically consistent way? Experiments maintaining sample compression against a transparent window can be tailored to present a uniform measurement area with uncertain spectral emissivity. We compare several methods to analyze radiance collected at multiple wavelengths, applying statistical methods and physical principles to improve temperature inference. With proper radiance collection and analysis, dynamic temperature uncertainties become comparable to thermomechanical ambiguities of the emitting surface.

36 MATERIALS SCIENCE↗

Surface plasmon dispersion analysis in the metal-oxide-metal tunnel diode

A detailed model of surface plasmon dispersion in the metal-oxide-metal tunnel diode is presented in order to clarify the spectral emission from this diode. The model predicts the location of the spectral peaks and the emission between the peaks by considering the effects of retardation on the surface plasmon. A nonradiative mode is found to play a major role in the transition from the visible to UV peaks in the diode spectra.

Donohue, J. F.↗

Laser-induced breakdown spectroscopy of light water reactor simulated used nuclear fuel: Main oxide phase

We show the analysis of light water reactor simulated used nuclear fuel using laser-induced breakdown spectroscopy (LIBS) is explored using a simplified version of the main oxide phase. The main oxide phase consists of the actinides, lanthanides, and zirconium. The purpose of this study is to develop a rapid, quantitative technique for measuring zirconium in a uranium dioxide matrix without the need to dissolve the material. A second set of materials including cerium oxide is also analyzed to determine precision and limit of detection (LOD) using LIBS in a complex matrix. Two types of samples are used in this study: binary and ternary oxide pellets. The ternary oxide, (U,Zr,Ce)O 2 pellets used in this study are a simplified version the main oxide phase of used nuclear fuel. The binary oxides, (U,Ce)O 2 and (U,Zr)O 2 are also examined to determine spectral emission lines for Ce and Zr, potential spectral interferences with uranium and baseline LOD values for Ce and Zr in a UO 2 matrix. In the spectral range of 200 to 800 nm, 33 cerium lines and 25 zirconium lines were identified and shown to have linear correlation values (R 2 ) > 0.97 for both the binary and ternary oxides. The cerium LOD in the (U,Ce)O 2 matrix ranged from 0.34 to 1.08 wt% and 0.94 to 1.22 wt% in (U,Ce,Zr)O 2 for 33 of Ce emission lines. The zirconium limit of detection in the (U,Zr)O 2 matrix ranged from 0.84 to 1.15 wt% and 0.99 to 1.10 wt% in (U,Ce,Zr)O 2 for 25 Zr lines. Finally, the effect of multiple elements in the plasma and the impact on the LOD is discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗