Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOLAR ADVISOR MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Method for Projecting Cloud Shadows Onto a Central Receiver Field to Predict Receiver Damage

This work demonstrates methods of mapping high-spatial-resolution direct normal irradiance (DNI) data from satellites, Total Sky Imagers (TSIs), and analogous data sources onto a heliostat field for characterizing the spatial and temporal variation of the incident flux on a central receiver tower during cloud transient events. The mapping methods are incorporated into an optical software module that interfaces with CoPylot–SolarPILOT’s python API– to provide computationally efficient optical simulation of the heliostat field and the solar power tower. Eventually, this optical model will be incorporated into optimization models whereby a plant operator can understand the effects of cloud transient events on overall power production and receiver lifetime due to creep-fatigue damage and therefore make better informed decisions about receiver shutdown events. By more accurately modelling the effects of cloud events on receiver flux maps, this work may determine the magnitude and frequency of thermal cycling on receiver tubes and panels using actual or realistic cloud shapes instead of averaged DNI values–which may undercount the total cycle number. This work may also prevent unnecessary plant shutdowns due to overly precautionary control strategies and characterize the relative impact of various cloud types on receiver life. We plan to eventually integrate this methodology into the System Advisor Model (SAM) to improve performance model accuracy during periods of cloudiness. In this paper, we demonstrate generating DNI maps and mapping them to a solar field in CoPylot using 10 m resolution data from publicly available Sentinel-2 satellite data over the Crescent Dunes plant.

Mullin, Matthew↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Direct-Steam Linear Fresnel Performance Model for NREL's System Advisor Model

This paper presents the technical formulation and demonstrated model performance results of a new direct-steam-generation (DSG) model in NREL's System Advisor Model (SAM). The model predicts the annual electricity production of a wide range of system configurations within the DSG Linear Fresnel technology by modeling hourly performance of the plant in detail. The quasi-steady-state formulationallows users to investigate energy and mass flows, operating temperatures, and pressure drops for geometries and solar field configurations of interest. The model includes tools for heat loss calculation using either empirical polynomial heat loss curves as a function of steam temperature, ambient temperature, and wind velocity, or a detailed evacuated tube receiver heat loss model. Thermallosses are evaluated using a computationally efficient nodal approach, where the solar field and headers are discretized into multiple nodes where heat losses, thermal inertia, steam conditions (including pressure, temperature, enthalpy, etc.) are individually evaluated during each time step of the simulation. This paper discusses the mathematical formulation for the solar field model anddescribes how the solar field is integrated with the other subsystem models, including the power cycle and optional auxiliary fossil system. Model results are also presented to demonstrate plant behavior in the various operating modes.

14 SOLAR ENERGY↗

Modeling Photovoltaic Module-Level Power Electronics in the System Advisor Model; NREL (National Renewable Energy Laboratory)

Module-level power electronics, such as DC power optimizers, microinverters, and those found in AC modules, are increasing in popularity in smaller-scale photovoltaic (PV) systems as their prices continue to decline. Therefore, it is important to provide PV modelers with guidelines about how to model these distributed power electronics appropriately in PV modeling software. This paper extends the work completed at NREL that provided recommendations to model the performance of distributed power electronics in NREL’s popular PVWatts calculator [1], to provide similar guidelines for modeling these technologies in NREL's more complex System Advisor Model (SAM). Module-level power electronics - such as DC power optimizers, microinverters, and those found in AC modules-- are increasing in popularity in smaller-scale photovoltaic (PV) systems as their prices continue to decline. Therefore, it is important to provide PV modelers with guidelines about how to model these distributed power electronics appropriately in PV modeling software.

14 SOLAR ENERGY↗

Bias Correction and Statistical Downscaling of Solar Radiation Using NA-CORDEX and the NSRDB

The current state-of-art for estimating long-term PV production uses long-term estimates of solar radiation variables, such as global horizontal irradiance (GHI), from previous years. This data is used in models such as the System Advisor Model (SAM) or PYSyst to predict annual production for a PV plant. This information is then used to estimate the production over the next 20 years (a typical plant lifetime) under the assumption that the variability over the current period is representative of the future. As the PV industry moves to extend plant lifetimes to 50 years the current assumptions of representativeness of weather may not be appropriate. This is especially true as our climate changes rapidly. To assess long-term PV production, future projections for solar radiation based on projected carbon emissions are readily available in regional and global climate models. However, climate model projections contain inherent biases that may need to be corrected for accurate analysis of future projections of climate variables. Several studies have analyzed projections of solar radiation for future years, however the accuracy of the model output compared to current and historic data has not been widely studied. Chen (2021) showed that available climate models do not accurately represent solar radiation in some cases, over-projecting GHI at the surface while under-projecting its obstructions, such as clouds and aerosols. This works aims to (1) increase understanding of the accuracy of solar radiation currently available in global and regional climate models and (2) implement bias correction through linear models based on reanalysis data compared to observed solar radiation. The latter aim will be conducted using available observed solar radiation data and modeled data from several regional climate models (RCMs). The bias correction method will be applied to projections of solar radiation resulting in a more accurate representation of the future of solar production.

climate data↗

Photovoltaic and Cost Analysis for Winston-Salem, North Carolina

This study assesses the feasibility of solar installations at various sites in Winston-Salem, focusing on factors such as solar resource availability, electricity costs, and rooftop area for photovoltaic systems. The analysis begins by estimating daily energy requirements based on annual electricity use, followed by adjusting for seasonal and operational fluctuations. Using regional solar data from the National Solar Radiation Database (NSRDB), we calculate average peak sun hours to determine effective system sizing. A parametric approach using the System Advisor Model (SAM) refines this sizing process, incorporating a safety margin of 1.2 to address demand peaks. Each PV system is designed to fit available rooftop space, and a coverage threshold of 70% is identified as optimal for maximizing cost savings and sustainability. This threshold allows installations to meet substantial energy demands, supporting energy resilience and enhancing economic returns.

14 SOLAR ENERGY↗

LOWERING THE LEVELIZED COST OF ELECTRICITY OF A CONCENTRATING SOLAR POWER TOWER WITH A SUPERCRITICAL CARBON DIOXIDE POWER CYCLE

In order to maintain viability as a future power-generating technology, concentrating solar power (CSP) must reduce its levelized cost of electricity (LCOE). The cost of CSP is assessed with the System Advisor Model (SAM) from the National Renewable Energy Laboratory (NREL). The performance of an integrally geared compressor-expander recuperated recompression cycle with supercritical carbon dioxide (sCO2) as the working fluid is modeled. A comparison of the cycle model to the integrated SAM cycle performance is made. The cycle model incorporates innovative cycle control methods to improve the range of efficiency, including inventory control. The SAM model is modified to accommodate the predicted cycle performance. The ultimate goal of minimizing the LCOE is targeted through multiple approaches, including the cost of the power block, the impact of system scale, the sizing of the thermal system relative to the power block system, the operating approach for changes in ambient temperature and availability of sunlight. Through reduced power block cost and a detailed cycle model, the LCOE is modeled to be 5.98 ¢/kWh, achieving targeted techno-economic performance. The LCOE of the CSP system is compared to the cost of hybrid solar and fossil-fired systems. An analysis is made on the efficacy of a fossil backup system with CSP and how that relates to potential future costs of carbon dioxide emissions

schmitt, josh↗

Short-Term Probabilistic Solar Forecasting via Reinforcement Learning over ECMWF

In this paper, we present an innovative reinforcement learning approach for short-term solar forecasting, leveraging data from the European Centre for Medium-Range Weather Forecasts (ECMWF). The methodology begins with the application of the System Advisor Model (SAM) to transform various ECMWF numerical weather prediction members into predictive photovoltaic power generation. To enhance the precision of deterministic forecasting, we introduce a dynamic model selection algorithm based on Q-learning. This algorithm dynamically identifies and utilizes the most accurate ensemble member for forecasting purposes. Furthermore, we employ a support vector regression surrogate model with a Gaussian distribution to generate probabilistic forecasts, providing a holistic view of solar energy generation uncertainty. To expedite the training process and make it more practical for real-world applications, we integrate a rolling update workflow. This innovative workflow reduces the training period from months to a mere 19 days, making our method highly efficient. Numerical results of the case study show that in comparison to benchmark models, the proposed method improves the deterministic and probabilistic solar forecasting accuracy by up to 40.84% and 48.42%, respectively.

ensemble forecasting↗

Solar Process Heat Potential in California, USA

The cost for solar industrial process heat (SIPH) is quantified by defining the levelized cost of heat (LCOH). The state of California, in the United States offers a favorable environment for SIPH given its excellent insolation, industrial gas prices typically higher than the national average, and policies promoting solarthermal deployment. Given historically low gas prices, competing with natural gas remains the primary challenge to deployment. However, this study finds that the solar LCOH from Concentrating Solar Power (CSP) collectors for many regions in California is expected to be lower than the LCOH from natural gas, using a representative installed solar hardware price and the average price for industrial natural gas in California. Lastly, modifications are in progress to the parabolic trough and Direct Steam Generation (DSG) trough and Linear Fresnel models within NREL's System Advisor Model (SAM) to allow users to more easily predict performance for these industrial heat and steam-generation applications.

14 SOLAR ENERGY↗

What's New in System Advisor Model

This talk will give an overview of recent and planned model improvements in the NLR System Advisor Model, including improved spectral model options, improved access to snow data for PV modeling across the United States, work on hybrid PV, CSP, and thermal energy storage modeling, current research into accurately modeling tandem cells, and more.

14 SOLAR ENERGY↗

Roadmap to Advance Heliostat Technologies for Concentrating Solar-Thermal Power

Heliostat-based concentrating solar-thermal power (CSP) systems can offer immense potential to provide low-cost, dispatchable renewable thermal and electrical energy to help achieve 100% decarbonized energy infrastructure in the United States. Heliostats are a major capital cost technology and a performance-dominating component of state-of-the-art commercial molten salt towers and Generation 3 CSP systems. In 2021, the U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO) launched the Heliostat Consortium (HelioCon), a five-year initiative to advance heliostat technologies. The HelioCon mission is threefold: (1) establish strategic core testing and modeling capabilities and infrastructure at national labs; (2) support heliostat technology development in relevant industries; and (3) serve as a central repository to integrate industry, academia, and other stakeholders for heliostat technology research, development, validation, and deployment. In this report, HelioCon presents a roadmapping study on advancing heliostat technologies, intended as a central reference for the whole CSP community.

14 SOLAR ENERGY↗

Techno-economic Analysis of Novel PV Plant Designs for Extreme Cost Reductions

A techno-economic analysis is underway examining the cost and performance of future large-scale photovoltaic (PV) plant components, including bifacial modules, tandem modules, increased plant voltage architectures, and module-level power electronics. Integration of these components into PV plant designs is compared with current PV technologies based on levelized cost of electricity (LCOE). Baseline models are developed and validated against recorded PV plant performance data. Expected cost and performance data of future PV technologies are incorporated into the baseline models. An evolutionary algorithm is utilized to optimize PV plant configuration, technology combination, and LCOE. This paper focuses on the bifacial module analysis.

14 SOLAR ENERGY↗

Technoeconomic Modeling of Battery Energy Storage in SAM

Detailed comprehensive lead-acid and lithium-ion battery models have been integrated with photovoltaic models in an effort to allow System Advisor Model (SAM) to offer the ability to predict the performance and economic benefit of behind the meter storage. In a system with storage, excess PV energy can be saved until later in the day when PV production has fallen, or until times of peak demand when it is more valuable. Complex dispatch strategies can be developed to leverage storage to reduce energy consumption or power demand based on the utility rate structure. This document describes the details of the battery performance and economic models in SAM.

14 SOLAR ENERGY↗

Evaluating Energy Impacts and Costs from PV Component Failures: Preprint

The PV Reliability Performance Model (PV-RPM) tool is used to simulate the cost and energy impacts of component faults and failures for a hypothetical PV system. This model, originally developed by Sandia National Laboratories, is a new feature in the National Renewable Energy Laboratory's System Advisor Model (SAM), which performs stochastic analysis sampling of probability distributions for faults, failures, and repairs. One PV system was created for this analysis to be representative of a portfolio of maintenance data maintained by Sandia National Laboratories. Fault, failure, and repair distributions from this system are varied from current baseline conditions to simulate different reliability and repair scenarios and resulting energy and cost impacts. Results highlight ways to express the uncertainty around PV system performance when considering the probabilistic behavior of components in the system, and ways the PV-RPM model can be used to explore different failure and repair scenarios.

14 SOLAR ENERGY↗

CSP Systems Analysis - Final Project Report

The CSP Systems Analysis project was a three-year effort supporting the Concentrating Solar Power (CSP) Subprogram within the Solar Energy Technologies Office of the U.S. Department of Energy (DOE). The goal of the CSP Systems Analysis project was to provide timely and accurate CSP cost data to the DOE and predict performance and cost for emerging technologies that may impact research directions and industry investment. The project consisted of six, mostly independent tasks. Major accomplishments over the three-year period of performance were as follows. The NREL team maintained current cost estimates for CSP technologies by annual updates to the cost input parameters within NREL's System Advisor Model (SAM). SAM is a performance and cost simulation software that includes technology models for the primary CSP technologies. During the period from 2016 to 2018, the estimated cost within SAM's default CSP molten-salt power tower technology dropped from 13.0 to 11.1 cent/kWh (real dollars without incentives). Power cycle models for the supercritical carbon dioxide (sCO2) Brayton Cycle were developed and made an option within SAM's molten-salt power tower model. These models were subsequently used to evaluate the cost reduction potential of alternative salts. The partial-cooling model was found to provide the greatest cost-reduction potential due to its combination of efficiency and temperature differential across the turbine and thermal energy storage (TES) system. These studies were documented in two journal articles. NREL's optical modeling software SolTrace and SolarPILOT were made more versatile and released as open-source software to the CSP community. These tools help researchers and developers to model and optimize the optical performance of CSP collector systems. The new features were highlighted in a recorded webinar that can be accessed from the NREL SAM website. New models for solar-thermal systems, that is, applications for solar industrial process heat, were developed, validated, and installed within SAM. The analysis includes a 2018 review of linear collectors in the market that are tailored for solar process heat applications. In 2018 the NREL team also developed an annual simulation for a direct steam generation system integrated with a latent-heat TES system. This analysis was submitted for journal publication. The NREL team continued to support the exchange of information and development of CSP guidelines within the international CSP community of SolarPACES. Much of the work under this project was presented at SolarPACES, including the development of a modeling checklist to help CSP stakeholders standardize the models used for estimating CSP performance and cost. The CSP Systems Analysis project also supported DOE requests for tracking and reporting programmatic targets for the CSP Subprogram.

14 SOLAR ENERGY↗

Behind-the-Meter Solar + Storage Modeling Tool Comparison

Several techno-economic models exist to evaluate solar PV plus battery storage opportunities for behind-the-meter, commercial application. This tool comparison evaluates the methodological differences between several solar plus storage modeling tools and employs a case study to compare their outputs. The tools selected for comparison include NREL's REopt Lite, NREL's System Advisor Model (SAM), Homer Energy's Homer Grid, Geli ESyst, EPRI StorageVET, and LBL's DER-CAM. The comparison focuses on each tool's simulation and optimization capabilities, PV and battery performance modeling, dispatch strategies, and economic model assumptions and calculations, with brief mention of additional capabilities outside the scope of behind-the-meter PV and battery storage. This report describes the case study's tool inputs and outputs and dives into the differences in assumptions, methodologies, and capabilities between tools.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗