Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOCKET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Kinematic chip to chip bonding

The various technologies presented herein relate to integrating an IC having at least one waveguide incorporated therein with a v-groove array IC such that an optical fiber located in a v-groove is aligned relative to a waveguide in the IC maximizing optical coupling between the fiber and the waveguide. The waveguide IC and the v-groove array IC are bonded in a stacked configuration. Alignment of the waveguide IC and the array IC in the stacked configuration enables advantage to be taken of lithographic accuracy of features formed with respect to the Z-direction. Further, kinematic pins and sockets are utilized to provision accuracy in the X- and Z-directions, wherein advantage is taken of the placement accuracy and fabrication tolerance(s) which can be utilized when forming the and sockets. Accordingly, automated alignment of the waveguide IC and the array IC is enabled, facilitating accurate alignment of the respective waveguides and fibers.

42 ENGINEERING↗

One step removed shadow network

A system and method includes an operational network that communicates with an external network by opening a first transmission protocol socket. A data diode coupled to the operational network and a gateway enables the one-way transfer of all information received from the external network and transmitted by the operational network to the gateway such that no information travels from the gateway to the operational network or the external network. The gateway opens a second transmission protocol socket by mapping a sequence number to an acknowledgement number and increasing that mapped acknowledgement number by a value of one. A transmitter then transmits the acknowledgment to a remote network or a gateway.

Park, Brent K.↗

Ion beam mill etch depth monitoring with nanometer-scale resolution

A method for measuring conductance of a material real-time during etching/milling includes providing a fixture having a socket for receiving the material. The socket is attached to a printed circuit board (PCB) mounted on one side of a plate that has at least one opening for providing ion beam access to the material sample. Conductive probes extend from the other side of the PCB to contact and span a target area of the material. A measurement circuit in electrical communication with the probes measures the voltage produced when a current is applied across the material sample to measure changes in electrical properties of the sample over time.

Cybart, Shane A.↗

Crystal-Packing Trends for a Series of 6,9,12,15,18-Pentaaryl-1-hydro[60]fullerenes

The relationship between the size of the substituents of aryl groups in a series of fifteen 6,9,12,15,18-pentaaryl-1-hydro[60]fullerenes and the solid-state structures and packing motifs of these compounds has been analyzed. Pentaarylfullerenes have a characteristic “badminton shuttlecock” shape that causes several derivatives to crystallize into columnar stacks. However, many pentaarylfullerenes form non-stacked structures with, for example, dimeric, layered, diamondoid, or feather-in-cavity relationships between molecules. Computational modeling gave a qualitative estimate of the best shape match between the ball and socket surfaces of each pentaarylfullerene. The best match was for pentaarylfullerenes with large, spherically shaped para-substituents on the aryl groups. The series of pentaarylfullerenes was characterized by single-crystal X-ray diffraction. A total of 34 crystal structures were obtained as various solvates and were categorized by their packing motifs.

36 MATERIALS SCIENCE↗

Comparative Performance Analysis of Coarse Solvers for Algebraic Multigrid on Multicore and Manycore Architectures

In this paper, we study the performance of a two-level algebraic-multigrid algorithm, with a focus on the impact of the coarse-grid solver on performance. We consider two algorithms for solving the coarse-space systems: the preconditioned conjugate gradient method and a new robust HSS-embedded low-rank sparse-factorization algorithm. Our test data comes from the SPE Comparative Solution Project for oil-reservoir simulations. We contrast the performance of our code on one 12-core socket of a Cray XC30 machine with performance on a 60-core Intel Xeon Phi coprocessor. To obtain top performance, we optimized the code to take full advantage of fine-grained parallelism and made it thread-friendly for high thread count. We also developed a bounds-and-bottlenecks performance model of the solver which we used to guide us through the optimization effort, and also carried out performance tuning in the solver’s large parameter space. Finally, as a result, significant speedups were obtained on both machines.

97 MATHEMATICS AND COMPUTING↗

Performance Evaluation of NWChem Ab-Initio Molecular Dynamics (AIMD) Simulations on the Intel® Xeon Phi™ Processor

Ab-initio Molecular Dynamics (AIMD) methods are an important class of algorithms, as they enable scientists to understand the chemistry and dynamics of molecular and condensed phase systems while retaining a first-principles-based description of their interactions. Many-core architectures such as the Intel® Xeon Phi™ processor are an interesting and promising target for these algorithms, as they can provide the computational power that is needed to solve interesting problems in chemistry. In this paper, we describe the efforts of refactoring the existing AIMD plane-wave method of NWChem from an MPI-only implementation to a scalable, hybrid code that employs MPI and OpenMP to exploit the capabilities of current and future many-core architectures. We describe the optimizations required to get close to optimal performance for the multiplication of the tall-and-skinny matrices that form the core of the computational algorithm. We present strong scaling results on the complete AIMD simulation for a test case that simulates 256 water molecules and that strong-scales well on a cluster of 1024 nodes of Intel Xeon Phi processors. We compare the performance obtained with a cluster of dual-socket Intel® Xeon® E5–2698v3 processors.

Environmental Molecular Sciences Laboratory↗

Effect of proteoglycans at interfaces as related to location, architecture, and mechanical cues

Covalently bound functional GAGs orchestrate tissue mechanics through time-dependent characteristics. The role of specific glycosaminoglycans (GAGs) at the ligament-cementum and cementum-dentin interfaces within a human periodontal complex were examined. Matrix swelling and resistance to compression under health and modeled diseased states was investigated. The presence of keratin sulfate (KS) and chondroitin sulfate (CS) GAGs at the ligament-cementum and cementum-dentin interfaces in human molars (N = 5) was illustrated by using enzymes, atomic force microscopy (AFM), and AFM-based nanoindentation. Furthermore, the change in physical characteristics of modeled diseased states through sequential digestion of keratin sulfate (KS) and chondroitin sulfate (CS) GAGs was investigated. One-way ANOVA tests with P < 0.05 were performed to determine significant differences between groups. Additionally, the presence of mineral within the seemingly hygroscopic interfaces was investigated using transmission electron microscopy. Immunohistochemistry (N = 3) indicated presence of biglycan and fibromodulin small leucine rich proteoglycans at the interfaces. Digestion of matrices with enzymes confirmed the presence of KS and CS GAGs at the interfaces by illustrating a change in ti ssue architecture and mechanics. A significant increase in height (nm), decrease in elastic modulus (GPa), and tissue deformation rate (nm/s) of the PDL-C attachment site (215 ± 63-424 ± 94 nm; 1.5 ± 0.7-0.4 ± 0.2 GPa; 21 ± 7-48 ± 22 nm/s), and cementum-dentin interface (122 ± 69-360 ± 159 nm; 2.9 ± 1.3-0.7 ± 0.3 GPa; 18 ± 4-30 ± 6 nm/s) was observed. The sequential removal of GAGs indicated loss in intricate structural hierarchy of hygroscopic interfaces. From a mechanics perspective, GAGs provide tissue recovery/resilience. Our results provide insights into the role of GAGs toward conserved tooth movement in the socket in response to mechanical loads, and modulation of potentially deleterious strain at tissue interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Separable projection integrals for higher-order correlators of the cosmic microwave sky: Acceleration by factors exceeding 100

We present a case study describing efforts to optimise and modernise “Modal”, the simulation and analysis pipeline used by the Planck satellite experiment for constraining general non-Gaussian models of the early universe via the bispectrum (or three-point correlator) of the cosmic microwave background radiation. We focus on one particular element of the code: the projection of bispectra from the end of inflation to the spherical shell at decoupling, which defines the CMB we observe today. This code involves a three-dimensional inner product between two functions, one of which requires an integral, on a non-rectangular domain containing a sparse grid. We show that by employing separable methods this calculation can be reduced to a one-dimensional summation plus two integrations, reducing the overall dimensionality from four to three. The introduction of separable functions also solves the issue of the non-rectangular sparse grid. This separable method can become unstable in certain scenarios and so the slower non-separable integral must be calculated instead. We present a discussion of the optimisation of both approaches. We demonstrate significant speed-ups of ≈100×, arising from a combination of algorithmic improvements and architecture-aware optimisations targeted at improving thread and vectorisation behaviour. The resulting MPI/OpenMP hybrid code is capable of executing on clusters containing processors and/or coprocessors, with strong-scaling efficiency of 98.6% on up to 16 nodes. We find that a single coprocessor outperforms two processor sockets by a factor of 1.3× and that running the same code across a combination of both microarchitectures improves performance-per-node by a factor of 3.38×. By making bispectrum calculations competitive with those for the power spectrum (or two-point correlator) we are now able to consider joint analysis for cosmological science exploitation of new data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterizing, Modeling, and Accurately Simulating Power and Energy Consumption of I/O-intensive Scientific Workflows

While distributed computing infrastructures can provide infrastructure-level techniques for managing energy consumption, application-level energy consumption models have also been developed to support energy-efficient scheduling and resource provisioning algorithms. In this work, we analyze the accuracy of a widely-used application-level model that has been developed and used in the context of scientific workflow executions. To this end, we profile two production scientific workflows on a distributed platform instrumented with power meters. We then conduct an analysis of power and energy consumption measurements. This analysis shows that power consumption is not linearly related to CPU utilization and that I/O operations significantly impact power, and thus energy, consumption. We then propose a power consumption model that accounts for I/O operations, including the impact of waiting for these operations to complete, and for concurrent task executions on multi-socket, multi-core compute nodes. We implement our proposed model as part of a simulator that allows us to draw direct comparisons between real-world and modeled power and energy consumption. Here, we find that our model has high accuracy when compared to real-world executions. Furthermore, our model improves accuracy by about two orders of magnitude when compared to the traditional models used in the energy-efficient workflow scheduling literature.

97 MATHEMATICS AND COMPUTING↗

An all-oxide electrolysis cells for syngas production with tunable H 2 /CO yield via co-electrolysis of H 2 O and CO 2

High-rate production of syngas with tunable H 2 /CO and coke-free operation is achieved in a solid-oxide electrolysis cell (SOEC). Prior to operation, controlled pre-reduction of La 0.7 Sr 0.3 Fe 0.9 Ni 0.1 O 3-δ (LSFNi) cathode is used to trigger the in-situ exsolution of Ni-Fe alloy nanoparticles with an average size of ~45 nm uniformly distributed and socketed on LSFNi backbone, enabling efficient co-electrolysis of H 2 O and CO 2 to H 2 and CO. At 1.5 V, the current density reaches ~1.0 A cm-2 at 750 °C and ~2.4 A cm -2 at 850 °C with near 100% Faradaic Efficiency. We demonstrate the feasibility of tuning the output H 2 /CO ratio by nearly two orders of magnitude (from ~0.1 to ~7) by manipulating H 2 O/CO 2 ratio of feed gas, operating temperature, and current density. Finally, stable operation for >100 h is obtained without evidence of carbon deposition, although high current density operation leads to observable deterioration of anode/electrolyte interface due to the rapid oxygen evolution.

25 ENERGY STORAGE↗

On Parallel Push-Relabel based Algorithms for Bipartite Maximum Matching

We study multithreaded push-relabel based algorithms for computing maximum cardinality matching in bipartite graphs. Matching is a fundamental combinatorial (graph) problem with applications in a wide variety of problems in science and engineering. We are motivated by its use in the context of sparse linear solvers for computing maximum transversal of a matrix. We implement and test our algorithms on several multi-socket multicore systems and compare their performance to state-of-the-art augmenting path-based serial and parallel algorithms using a testset comprised of a wide range of real-world instances. Building on several heuristics for enhancing performance, we demonstrate good scaling for the parallel push-relabel algorithm. We show that it is comparable to the best augmenting path-based algorithms for bipartite matching. To the best of our knowledge, this is the first extensive study of multithreaded push-relabel based algorithms. In addition to a direct impact on the applications using matching, the proposed algorithmic techniques can be extended to preflow-push based algorithms for computing maximum flow in graphs.

Push-relabel, matching, bipartite↗

Friction behavior of a multi-interface system and improved performance by AlMgB 14 –TiB 2 –C and diamond-like-carbon coatings

We investigated friction behavior of a bearing system with two interfaces involved: a roller component experiencing rolling–sliding interaction against twin cylinders under point contacts while simultaneously undergoing pure sliding interaction against a socket under a conformal contact. Lubrication modeling predicted a strong correlation between the roller's rolling condition and the system's friction behavior. Experimental observations first validated the analytical predictions using steel and iron components. Diamond-like-carbon (DLC) coating and AlMgB 14 –TiB 2 coating with a carbon topcoat (BAMC) were then applied to the roller and twin cylinders, respectively. In conclusion, testing and analysis results suggest that the coatings effectively decreased the slip ratio for the roller–cylinder contact and the sliding friction at both bearing interfaces and, as a result, significantly reduced the system frictional torque.

42 ENGINEERING↗

Structural insights into inhibition of lipid I production in bacterial cell wall synthesis

Antibiotic-resistant bacterial infection is a serious threat to public health. Peptidoglycan biosynthesis is a well-established target for antibiotic development. MraY (phospho-MurNAc-pentapeptide translocase) catalyses the first and an essential membrane step of peptidoglycan biosynthesis. It is considered a very promising target for the development of new antibiotics, as many naturally occurring nucleoside inhibitors with antibacterial activity target this enzyme. However, antibiotics targeting MraY have not been developed for clinical use, mainly owing to a lack of structural insight into inhibition of this enzyme. Here we present the crystal structure of MraY from Aquifex aeolicus (MraY AA ) in complex with its naturally occurring inhibitor, muraymycin D2 (MD2). We show that after binding MD2, MraY AA undergoes remarkably large conformational rearrangements near the active site, which lead to the formation of a nucleoside-binding pocket and a peptide-binding site. MD2 binds the nucleoside-binding pocket like a two-pronged plug inserting into a socket. Further interactions it makes in the adjacent peptide-binding site anchor MD2 to and enhance its affinity for MraY AA . Surprisingly, MD2 does not interact with three acidic residues or the Mg 2+ cofactor required for catalysis, suggesting that MD2 binds to MraY AA in a manner that overlaps with, but is distinct from, its natural substrate, UDP-MurNAc-pentapeptide. We have determined the principles of MD2 binding to MraY AA , including how it avoids the need for pyrophosphate and sugar moieties, which are essential features for substrate binding. The conformational plasticity of MraY could be the reason that it is the target of many structurally distinct inhibitors. Furthermore, these findings can inform the design of new inhibitors targeting MraY as well as its paralogues, WecA and TarO.

59 BASIC BIOLOGICAL SCIENCES↗

Development of the Fast Scintillation Detector with Programmable High Voltage Adjustment Suitable for Moessbauer Spectroscopy

This work is focused on a development of a compact fast scintillation detector suitable for Moessbauer spectroscopy (low energy X-ray/{gamma}-ray detection) where high counting rates are inevitable. Optimization of this part was necessary for a reliable function, better time resolution and to avoid a detector pulses pile-up effect. The pile-up effect decreases the measurement performance, significantly depends on the source activity and also on the pulse duration. Our new detection unit includes a fast scintillation crystal YAP:Ce, an R6095 photomultiplier tube, a high voltage power supply socket C9028-01 assembly, an AD5252 digital potentiometer with an I2C interface and an AD8000 ultra fast operation preamplifier. The main advantages of this solution lie in a short pulse duration (less than 200 ns), stable operation for high activities, programmable gain of the high voltage supply and compact design in the aluminum housing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by using an analytical model for the relatively simple sample geometry and applying it to numerical forward simulations of the optical Fresnel propagation, we show that quantitative measurements of the microgap width down to 0.1 {mu}m are possible. Image data recorded at the BAMline (BESSY-II light source, Germany) are presented, with the resolving power of the imaging system being 4 {mu}m in absorption mode and {approx}14 {mu}m in phase contrast mode (z{sub 2}=0.74 m). Thus, phase contrast radiography, combined with numerical forward simulations, is capable of measuring the widths of gaps that are two orders of magnitude thinner than the conventional detection limit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DFTB+, a software package for efficient approximate density functional theory based atomistic simulations

DFTB+ is a versatile community developed open source software package offering fast and efficient methods for carrying out atomistic quantum mechanical simulations. By implementing various methods approximating density functional theory (DFT), such as the density functional based tight binding (DFTB) and the extended tight binding method, it enables simulations of large systems and long timescales with reasonable accuracy while being considerably faster for typical simulations than the respective ab initio methods. Based on the DFTB framework, it additionally offers approximated versions of various DFT extensions including hybrid functionals, time dependent formalism for treating excited systems, electron transport using non-equilibrium Green’s functions, and many more. DFTB+ can be used as a user-friendly standalone application in addition to being embedded into other software packages as a library or acting as a calculation-server accessed by socket communication. We give an overview of the recently developed capabilities of the DFTB+ code, demonstrating with a few use case examples, discuss the strengths and weaknesses of the various features, and also discuss on-going developments and possible future perspectives.

74 ATOMIC AND MOLECULAR PHYSICS↗

Quick-connect scanning tunneling microscope head with nested piezoelectric coarse walkers

To meet changing research demands, new scanning tunneling microscope (STM) features must constantly evolve. We describe the design, development, and performance of a modular plug-in STM, which is compact and stable. The STM head is equipped with a quick-connect socket that is matched to a universal connector plug, enabling it to be transferred between systems. This head can be introduced into a vacuum system via a load-lock and transferred to various sites equipped with the connector plug, permitting multi-site STM operation. Its design allows for reliable operation in a variety of experimental conditions, including a broad temperature range, ultra-high vacuum, high magnetic fields, and closed-cycle pulse-tube cooling. The STM’s compact size is achieved by a novel nested piezoelectric coarse walker design, which allows for large orthogonal travel in the X, Y, and Z directions, ideal for studying both bulk and thin film samples ranging in size from mm to μm. Its stability and noise tolerance are demonstrated by achieving atomic resolution under ambient conditions on a laboratory desktop with no vibrational or acoustic isolation. The operation of the nested coarse walkers is demonstrated by successful navigation to a μm-sized 2D sample.

Instruments & Instrumentation↗