Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SNR IMPROVEMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Demonstrating the Potential of Adaptive LMS Filtering on FPGA-Based Qubit Control Platforms for Improved Qubit Readout in 2D and 3D Quantum Processing Units

Advancements in quantum computing underscore the critical need for sophisticated qubit readout techniques to accurately discern quantum states. This abstract presents our research intended for optimizing readout pulse fidelity for 2D and 3D Quantum Processing Units (QPUs), the latter coupled with Superconducting Radio Frequency (SRF) cavities. Focusing specifically on the application of the Least Mean Squares (LMS) adaptive filtering algorithm, we explore its integration into the FPGA-based control systems to enhance the accuracy and efficiency of qubit state detection by improving Signal-to-Noise Ratio (SNR). Implementing the LMS algorithm on the Zynq UltraScale+ RFSoC Gen 3 devices (RFSoC 4x2 FPGA and ZCU216 FPGA) using the Quantum Instrumentation Control Kit (QICK) open-source platform, we aim to dynamically test and adjust the filtering parameters in real-time to characterize and adapt to the noise profile presented in quantum computing readout signals. Our preliminary results demonstrate the LMS filter's capability to maintain high readout accuracy while efficiently managing FPGA resources. These findings are expected to contribute to developing more reliable and scalable quantum computing architectures, highlighting the pivotal role of adaptive signal processing in quantum technology advancements.

Johnson, Hans↗

Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the quantitative histogram parameters of volume transfer constant [standard deviation (SD), 98th percentile, and range], rate constant (SD), blood volume fraction (mean, SD, 98th percentile, and range), and blood flow (mean, SD, median, 98th percentile, and range) for sampling intervals between 10 and 15 s. Conclusions: The proposed method of PCA filtering combined with the AIF estimation technique allows low frequency scanning for DCE-CT study to reduce patient radiation dose. The results indicate that the method is useful in pixel-by-pixel kinetic analysis of DCE-CT data for patients with cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-80: Beta-Minus Emitting Radiotracers Improves Molecular Endoscopy

Purpose: Molecular Endoscopy using Cerenkov Luminescence can be used to monitor the distribution of many clinically-available PET and SPECT probes for endoscopic applications. A main limitation of Cerenkov is its limited sensitivity to small concentrations of radiotracer when using light guides s. Herein we demonstrate that the use of a high energy beta emitting radioisotope, exemplified here with 90Y provides superior sensitivity to 18F because of its higher light output and its lack of corresponding gamma emission. Methods: A series of phantom experiments were performed to compare the sensitivity and noise of the CLE system for imaging 90Y and 18F. Three vials of known concentrations of 90Y (0.008 μCi, 0.08 μCi, 1 μCi) were placed in centrifuge tubes and isolated from each other. One vial of 18F (100 μCi) was placed in the imaging chamber and imaged over the course of decay (19 hours, 43 minutes, or ∼10 half-lives). Image time-points were formed from 5-minute integrations. Results: Using an SNR of 10 to define the noise-floor, the 90Y minimum detectable activity was 0.056 μCi. To the contrast, the minimum detectable activity for 18F was 11.63 μCi. These data demonstrate a 207-fold improvement in SNR of 90Y compared to 18F, when controlled for activity. Conclusion: This study demonstrated that a pure β- radionuclide such as 90Y be used is superior to 18F for Cerenkov Endoscopy. Further study is needed to demonstrate its utility in preclinical studies, endoscopic applications, intraoperative, and radiotherapy applications.

07 ISOTOPE AND RADIATION SOURCES↗

Simultaneous Improvement of Resolving Power and Signal-to-Noise Ratio Using a Modified Hadamard Transform-Inverse Ion Mobility Spectrometry Technique

In order to improve the resolving power (RP) and signal-to-noise ratio (SNR) of ion mobility spectrometry (IMS) simultaneously, a modified Hadamard transform-inverse ion mobility spectrometry (MHT-IIMS) technique was developed. In this novel technique, a series of isolating codes were appended to each element of the pseudo random binary sequence (PRBS), and then the modified modulation sequence was formed and used to control the ion gate of the inverse IMS (IIMS). Experimental results demonstrate that the MHT-IIMS technique can significantly enhance the resolving power and SNR simultaneously by measuring the spectra of reaction ions. Furthermore, the gas sample CCl{sub 4} and CHCl{sub 3} were measured for evaluating the capability of detecting those samples which have single and multiple product ions. The results show that this novel technique is able to simultaneously improve the resolving power and SNR notablely for the real sample detection without any significant instrumental changes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Shortwave Infrared Atmospheric Correction for Ocean Color Remote Sensing of Chesapeake Bay

The NASA Moderate Resolution Imaging Spectroradiometer onboard the Aqua platform (MODIS-Aqua) provides a viable data stream for operational water quality monitoring of Chesapeake Bay. Marine geophysical products from MODIS-Aqua depend on the efficacy of the atmospheric correction process, which can be problematic in coastal environments. The operational atmospheric correction algorithm for MODIS-Aqua requires an assumption of negligible near-infrared water-leaving radiance, nL(sub w)(NIR). This assumption progressively degrades with increasing turbidity and, as such, methods exist to account for non-negligible nL(sub w)(NIR) within the atmospheric correction process or to use alternate radiometric bands where the assumption is satisfied, such as those positioned within shortwave infrared (SWIR) region of the spectrum. We evaluated a decade-long time-series of nL(sub w)(lambda) from MODIS-Aqua in Chesapeake Bay derived using NIR and SWIR bands for atmospheric correction. Low signal-to-noise ratios (SNR) for the SWIR bands of MODIS-Aqua added noise errors to the derived radiances, which produced broad, flat frequency distributions of nL(sub w)(lambda) relative to those produced using the NIR bands. The SWIR approach produced an increased number of negative nL(sub w)(lambda) and decreased sample size relative to the NIR approach. Revised vicarious calibration and regional tuning of the scheme to switch between the NIR and SWIR approaches may improve retrievals in Chesapeake Bay, however, poor SNR values for the MODIS-Aqua SWIR bands remain the primary deficiency of the SWIR-based atmospheric correction approach.

Werdell, P. Jeremy↗

Spectral-domain phase microscopy with improved sensitivity using two-dimensional detector arrays

In this work we demonstrate the use of two-dimensional detectors to improve the signal-to-noise ratio (SNR) and sensitivity in spectral-domain phase microscopy for subnanometer accuracy measurements. We show that an increase in SNR can be obtained, from 82 dB to 105 dB, using 150 pixel lines of a low-cost CCD camera as compared to a single line, to compute an averaged axial scan. In optimal mechanical conditions, phase stability as small as 92 {mu}rad, corresponding to 6 pm displacement accuracy, could be obtained. We also experimentally demonstrate the benefit of spatial-averaging in terms of the reduction of signal fading due to an axially moving sample. The applications of the improved system are illustrated by imaging live cells in culture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-Sensitive Optical Time Domain Reflectometry With Rayleigh Enhanced Optical Fiber

In this paper, a phase-sensitive optical time domain reflectometry (Φ-OTDR) based on Rayleigh enhanced optical fiber is proposed to improve the system signal-to-noise ratio (SNR). In the experiment, the vibration performance of the Rayleigh enhanced optical fiber is analyzed and compared with standard single-mode telecom fiber. The results demonstrate that the measured SNRs of peaks in frequency spectra have been improved by 14 dB (at 1 kHz vibration frequency) at the end of the 2 km specialty sensing fiber. A wide range of vibration frequencies from 50 Hz to 15 kHz are demonstrated experimentally. The proposed method overcomes the inherent limitations of the conventional Φ-OTDR system and significantly enhances the vibration sensing performance.

47 OTHER INSTRUMENTATION↗

Multiple symbol partially coherent detection of MPSK

It is shown that by using the known (or estimated) value of carrier tracking loop signal to noise ratio (SNR) in the decision metric, it is possible to improve the error probability performance of a partially coherent multiple phase-shift-keying (MPSK) system relative to that corresponding to the commonly used ideal coherent decision rule. Using a maximum-likeihood approach, an optimum decision metric is derived and shown to take the form of a weighted sum of the ideal coherent decision metric (i.e., correlation) and the noncoherent decision metric which is optimum for differential detection of MPSK. The performance of a receiver based on this optimum decision rule is derived and shown to provide continued improvement with increasing length of observation interval (data symbol sequence length). Unfortunately, increasing the observation length does not eliminate the error floor associated with the finite loop SNR. Nevertheless, in the limit of infinite observation length, the average error probability performance approaches the algebraic sum of the error floor and the performance of ideal coherent detection, i.e., at any error probability above the error floor, there is no degradation due to the partial coherence. It is shown that this limiting behavior is virtually achievable with practical size observation lengths. Furthermore, the performance is quite insensitive to mismatch between the estimate of loop SNR (e.g., obtained from measurement) fed to the decision metric and its true value. These results may be of use in low-cost Earth-orbiting or deep-space missions employing coded modulations.

Simon, M. K.↗

Reconfigurable Intelligent Surfaces Empowered THz Communication in LEO Satellite Networks

Massive swarms of low Earth orbit (LEO) satellites are poising to serve for high-speed and low-latency ubiquitous connectivity with almost global coverage. Broadband inter-satellite communication is one of the key elements of satellite communication systems that orchestrate massive satellite swarms in cooperation. Thanks to technological advancements in microelectronics and micro-systems, the terahertz (THz) band has emerged as a strong candidate for inter-satellite links (ISLs) due to its promise of wideband communication. Especially, multi-antenna systems can improve the system performance along with the wideband supported by the THz band. However, multi-antenna systems should be reconsidered due to their size, weight, and price/power (SWaP) constraints. On the other hand, as a state-of-art multi-antenna technology, reconfigurable intelligent surface (RIS) is able to relax SWaP constraints because of its passive component-based structures. However, as similar reflection characteristic throughout wideband is difficult to meet, it is possible to observe beam misalignment. In this work, we first provide an assessment of the use of the THz band for ISLs and quantify the impact of misalignment fading on error performance. Then, in order to compensate for the high path loss associated with high carrier frequencies, and to further improve the signal-to-noise ratio (SNR), we propose the use of RISs mounted on neighboring satellites to enable signal propagation. Based on a mathematical analysis of the problem, we present the error rate expressions for RIS-assisted ISLs with misalignment fading. Also, numerical results show that RIS can leverage the error rate performance and achievable capacity of THz ISLs.

reconfigurable intelligent surfaces (RISs)↗

Contact-Less Integrity Verification of Microelectronics Using Near-Field EM Analysis

Modern microelectronics life-cycle and supply chain ecosystem bring multiple untrusted entities, which can compromise their integrity. A major integrity issue of microelectronics stems from piracy of intellectual properties (IP) and counterfeiting, which causes significant revenue loss to the semiconductor manufacturers. Further, these components often lead to compromised functionality, reliability, security, and safety of an electronic system. This paper presents secure information transmission and probing methods for verifying the integrity of digital integrated circuit (ICs) based on their electromagnetic (EM) near-field emissions and thereby protecting systems against counterfeit components. The proposed method has been tested on both high-level instructions executed by microprocessors or Systems-on-Chip (serving as examples of software), and also logic circuits within FPGA fabrics and ASICs (serving as examples of hardware). The authentication information required by each digital system is generated using a pseudo-random number generator circuit and securely transmitted via near-field magnetic emissions. The authorized party can probe these emissions using a near-field probe, process the acquired signals to improve the signal-to-noise ratio (SNR), and then recover the secure information through matched filtering. Experimental results from commercial SoCs are used to demonstrate the proposed technique. Methods for reducing EM interference during integrity verification of both FPGAs and ASICs are also described.

47 OTHER INSTRUMENTATION↗

Study on influence of PSP measurement system characteristics

The pressure-sensitive paint (PSP) technique as an optical method enables measurement of surface pressure distribution over a model and its measurement system plays an important role in this technique. In the present study, the fluorescent PSP is used and PSP measurement system is established by the authors. The influence of the measurement system characteristics on calibration curves is then explored through many PSP calibration experiments. With five camera apertures and two ultraviolet (UV) lamp powers, the original PSP calibration images and curves are presented in this paper. The experimental results demonstrated that: (1) the characteristics of the PSP measurement system have an important effect on the pressure measurement; (2) the 400-W UV lamp can provide adequate excitation photons to excite fluorescence molecules entering the energy transition and a larger charge-coupled device (CCD) aperture can be used to improve the signal-to-noise rate (SNR) of the CCD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microseismic Event Denoising: Removal of Borehole Waves

The vertical borehole array at Farnsworth Unit, TX is used to monitor microseismic activity in the subsurface around the Carbon Capture and Sequestration (CCS) reservoir. The array consists of 16 3-component seismometers spaced vertically in a single borehole. Tube or borehole waves traveling up or down the borehole can corrupt signals of interest, such as microseismic events. A denoising convolutional neural network (DCNN) was trained to remove borehole waves from seismic waveforms of microseismic events for the purpose of reducing unwanted signal detections and better characterizing events of interest. This R&D leverages the work of Sandia colleague Rigo Tibi, who used a DCNN developed by Greg Beroza at Stanford University to improve the signal-to-noise ratio (SNR) of teleseismic events detected by the International Monitoring System.

58 GEOSCIENCES↗

Signal to Noise Studies on Thermographic Data with Fabricated Defects for Defense Structures

There is a growing international interest in thermal inspection systems for asset life assessment and management of defense platforms. The efficacy of flash thermography is generally enhanced by applying image processing algorithms to the observations of raw temperature. Improving the defect signal to noise ratio (SNR) is of primary interest to reduce false calls and allow for easier interpretation of a thermal inspection image. Several factors affecting defect SNR were studied such as data compression and reconstruction using principal component analysis and time window processing.

Zalameda, Joseph N.↗

Folding Elastic Thermal Surface - FETS

The FETS is a light and compact thermal surface (sun shade, IR thermal shield, cover, and/or deployable radiator) that is mounted on a set of offset tape-spring hinges. The thermal surface is constrained during launch and activated in space by a thermomechanical latch such as a wax actuator. An application-specific embodiment of this technology developed for the MATMOS (Mars Atmospheric Trace Molecule Occultation Spectrometer) project serves as a deployable cover and thermal shield for its passive cooler. The FETS fits compactly against the instrument within the constrained launch envelope, and then unfolds into a larger area once in space. In this application, the FETS protects the passive cooler from thermal damage and contamination during ground operations, launch, and during orbit insertion. Once unfolded or deployed, the FETS serves as a heat shield, intercepting parasitic heat loads by blocking the passive cooler s view of the warm spacecraft. The technology significantly enhances the capabilities of instruments requiring either active or passive cooling of optical detectors. This can be particularly important for instruments where performance is limited by the available radiator area. Examples would be IR optical instruments on CubeSATs or those launched as hosted payloads because radiator area is limited and views are often undesirable. As a deployable radiator, the panels making up the FETS are linked thermally by thermal straps and heat pipes; the structural support and deployment energy is provided using tape-spring hinges. The FETS is a novel combination of existing technologies. Prior art for deployable heat shields uses rotating hinges that typically must be lubricated to avoid cold welding or static friction. By using tape-spring hinges, the FETS avoids the need for lubricants by avoiding friction altogether. This also eliminates the potential for contamination of nearby cooled optics by outgassing lubricants. Furthermore, the tape-spring design of the FETS is also self-locking so the panels stay in a rigid and extended configuration after deployment. This unexpected benefit makes the tape-spring hinge design of the FETS a light, simple, reliable, compact, non-outgassing hinge, spring, and latch. While tape-spring hinges are not novel, they have never been used to deploy passive unfolding thermal surfaces (radiator panels, covers, sun shades, or IR thermal shields). Furthermore, because this technology is compact, it has minimal impact on the launch envelope and mass specifications. FETS enhances the performance of hosted payload instruments where the science data is limited by dark noise. Incorporating FETS into a thermal control system increases radiator area, which lowers the optical detector temperature. This results in higher SNR (signal-to-noise ratio) and improved science data.

Urquiza, Eugenio↗

Reduction of amplified spontaneous emission noise using a statistical signal adaptive filter

This paper proposes a statistical signal adaptive filter (SSAF) based on adaptive total variation to reduce amplified spontaneous emission (ASE) noise in optical amplifiers, e.g. erbium doped fiber amplifiers. Non-return-to-zero on–off keying signal to noise ratio (SNR) is degraded by ASE noise. However, this can be improved by squeezing ASE using the proposed SSAF after photodetection to effectively remove the noise by analyzing the signal movement statistically. We obtained 4-dB SNR gain by reducing ASE beat noise compared with not applying SSAF. Simultaneous optical bandpass filter and SSAF application reduced the 2-dB power penalty for a 20-km optical link more than when only SSAF was used.

36 MATERIALS SCIENCE↗

Effect of ghrelin on the motor deficit caused by the ablation of nigrostriatal dopaminergic cells or the inhibition of striatal dopamine receptors

Highlights: • A functional ghrelin receptor GHSR1a is dominantly found in DA neurons in the SNc. • GHSR1a is also located on GABAergic neurons in the SNr. • Activation of GHSRs on SNc-DA neurons improves motor deficits. • GHSRs located on non-DA cells are not associated with motor function. Ghrelin plays roles in a wide range of central functions by activating the growth hormone secretagogue receptor (GHSR). This receptor has recently been found in the substantia nigra (SN) to control dopamine (DA)-related physiological functions. The dysregulation of DA neurons in the SN pars compacta (SNc) and the consequent depletion of striatal DA are known to underlie the motor deficits observed in Parkinson's disease (PD). In the present study, we further investigated the role of the SN-ghrelin system in motor function under the stereotaxic injection of AAV-CMV-FLEX-diphtheria toxin A (DTA) into the SN of dopamine transporter (DAT)-Cre (DAT{sup SN}::DTA) mice to expunge DA neurons of the SNc. First, we confirmed the dominant expression of GHSR1a, which is a functional GHSR, in tyrosine hydroxylase (TH)-positive DA neurons in the SNc of control mice. In DAT{sup SN}::DTA mice, we clearly observed motor dysfunction using several behavioral tests. An immunohistochemical study revealed a dramatic loss of TH-positive DA neurons in the SNc and DAT-labeled axon terminals in the striatum, and an absence of mRNAs for TH and DAT in the SN of DAT{sup SN}::DTA mice. The mRNA level of GHSR1a was drastically decreased in the SN of these mice. In normal mice, we also found the mRNA expression of GHSR1a within GABAergic neurons in the SN pars reticulata (SNr). Under these conditions, a single injection of ghrelin into the SN failed to improve the motor deficits caused by ablation of the nigrostriatal DA network using DAT{sup SN}::DTA mice, whereas intra-SN injection of ghrelin suppressed the motor dysfunction caused by the administration of haloperidol, which is associated with the transient inhibition of DA transmission. These findings suggest that phasic activation of the SNc-ghrelin system could improve the dysregulation of nigrostriatal DA transmission related to the initial stage of PD, but not the motor deficits under the depletion of nigrostriatal DA. Although GHSRs are found in non-DA cells of the SNr, GHSRs on DA neurons in the SNc may play a crucial role in motor function.

60 APPLIED LIFE SCIENCES↗

A NEW LOOK AT THE INTEGRATED RADIO/MICROWAVE CONTINUUM SPECTRUM OF GALACTIC SUPERNOVA REMNANT IC 443

Recent observations of the microwave sky, by space telescopes such as the Wilkinson Microwave Anisotropy Probe and Planck , have opened a new window into the analysis of continuum emission from supernova remnants (SNRs). In this paper, different emission models that can explain the characteristic shape of currently known integrated radio/microwave continuum spectrum of the Galactic SNR IC 443 are tested and discussed. In particular, the possibility is emphasized that the slight bump in the integrated continuum of this remnant around 20–70 GHz is genuine and that it can be explained by the contribution of an additional emission mechanism such as spinning dust. We find that adding a spinning dust component to the emission model improves the fit of the integrated spectrum of this SNR while at the same time preserving the physically probable parameter values. Finally, models that include the high-frequency synchrotron bending of the IC 443 radio to microwave continuum are favored.

79 ASTRONOMY AND ASTROPHYSICS↗

Significantly Improving Regional Seismic Amplitude Tomography at Higher Frequencies by Determining S -Wave Bandwidth

Characterizing regional seismic signals continues to be a difficult problem due to their variability. Calibration of these signals is very important to many aspects of monitoring underground nuclear explosions, including detecting seismic signals, discriminating explosions from earthquakes, and reliably estimating magnitude and yield. Amplitude tomography, which simultaneously inverts for source, propagation, and site effects, is a leading method of calibrating these signals. A major issue in amplitude tomography is the data quality of the input amplitude measurements. Pre-event and prephase signal-to-noise ratio (SNR) tests are typically used but can frequently include bad signals and exclude good signals. The deficiencies of SNR criteria, which are demonstrated here, lead to large calibration errors. To ameliorate these issues, we introduce a semi-automated approach to assess the bandwidth of a spectrum where it behaves physically. We determine the maximum frequency (denoted as F max ) where it deviates from this behavior due to inflections at which noise or spurious signals start to bias the spectra away from the expected decay. We compare two amplitude tomography runs using the SNR and new F max criteria and show significant improvements to the stability and accuracy of the tomography output for frequency bands higher than 2 Hz by using our assessments of valid S-wave bandwidth. We compare Q estimates, P/S residuals, and some detailed results to explain the improvements. Lastly, for frequency bands higher than 4 Hz, needed for effective P/S discrimination of explosions from earthquakes, the new bandwidth criteria sufficiently fix the instabilities and errors so that the residuals and calibration terms are useful for application.

58 GEOSCIENCES↗