SEARCH · Engineering Papers
Results for “SLAC”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
LCLS RF Station Anomaly Candidates, SLAC, Nov 2020 to Dec 2020, Version 1
The data consists of radio-frequency (RF) station process variables (amplitude and amplitude-mean-out-of-tolerance bit) and beam position monitor (BPM) values for about a month of Linac Coherent Light Source (LCLS) time. The data is all from normal conducting hard X-ray operation. The dataset contains roughly 5000 anomaly “candidates.” For each candidate, we include 3.5 minutes of data from the 82 RF stations and ~20 seconds of data from 4 BPMs. We also include several CSV files with additional information and labels for each candidate.
slac-lcls/psdm-databooks
This repo contains many notebooks and related tools to analyses datasets from the LCLS data mover or testing system performance (mostly related to I/O).
The Parasites: Synchrotron Radiation at SLAC, 1972–1992
Explore the source record for details and available documents.
A Proposal for Study of Structure and Dynamics of Energy/Matter Based on Production of Gamma-Ray at SLAC Facility
The success of this proposal will open new areas of Chemistry with antimatter: (1) new chemical dynamics; (2) exclusive production of parent ions by energy-tuning the positrons; (3) formation of antimatter compounds; (4) nano- and microscopic imaging of molecules, cells, and tumors (5) multi-positron systems and their thermodynamics and chemical kinetics. Also with o-Ps and p-Ps physics including speculations of dark mater (PAMELA & ATIC reported excesses in the e{sup +}e{sup -} cosmic rays).
Papers from the SLAC DOE Science Undergraduate Laboratory Internship Program (SULI 2011)
SPIRES, an aging high-energy physics publication data base, is in the process of being replaced by INSPIRE. In order to ease the transition from SPIRES to INSPIRE it is important to understand user behavior and the drivers for adoption. The goal of this project was to address some questions in regards to the presumed two-thirds of the users still using SPIRES. These questions are answered through analysis of the log files from both websites. A series of scripts were developed to collect and interpret the data contained in the log files. The common search patterns and usage comparisons are made between INSPIRE and SPIRES, and a method for detecting user frustration is presented. The analysis reveals a more even split than originally thought as well as the expected trend of user transition to INSPIRE.
SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL: Development of Electron Radiography for Material Science
The material science community is presently limited by diagnostics in both the fabrication of materials and measuring the resulting materials characteristics of these new fabrication techniques. Because of this limitation the community is forced into an empirical mode of material fabrication, where expert judgment is used to guide manufacturing processes and the resulting materials are inspected and tested for the desired characteristics. This development approach can be time consuming and costly. The solution to this problem is to improve our fundamental understanding of materials, which requires the development of new diagnostics capable of measurement at the micron length scale, during both processing and during testing. These new measurements will enable a fundamental understanding of material characteristics allowing the development of predictive models, which will in turn enable material engineering by design rather than today’s empirical approach. Solving this problem has become a grand challenge for the materials science community. Los Alamos plans to address this challenge through the development of new diagnostics capable of measurements at the smallest length scales through the Multi-Probe Diagnostic Hall (MPDH) at the planned MaRIE (Material and Radiation In Extremes) Facility. One of the probes will be a coherent photon beam generated by an FEL driven by a multi-GeV electron beam. The photons will be used for diffraction measurements as well as radiography of relatively thin samples (nearly single grains). The same multi-GeV electron beam can be used to directly radiograph thicker systems (many grains or “bulk” material), providing high resolution measurements of the density distribution of materials during both fabrication and dynamic testing. This technique, electron radiography or eRad, that has been identified by LANL as one of the probes required to meet this grand challenge has never been demonstrated with high energy electrons. We propose to begin development of this technique with the electron beam available at FACET.
S-Band RF Load Upgrade Program for SLAC Linac [Slides]
Abstract not provided.
Engineering at SLAC: Designing and Constructing Experimental Devices for the Stanford Synchrotron Radiation Lightsource (Final Paper)
Thanks to the versatility of the beam lines at SSRL, research there is varied and benefits multiple fields. Each experiment requires a particular set of experiment equipment, which in turns requires its own particular assembly. As such, new engineering challenges arise from each new experiment. My role as an engineering intern has been to help solve these challenges, by designing and assembling experimental devices. My first project was to design a heated sample holder, which will be used to investigate the effect of temperature on a sample's x-ray diffraction pattern. My second project was to help set up an imaging test, which involved designing a cooled grating holder and assembling multiple positioning stages. My third project was designing a 3D-printed pencil holder for the SSRL workstations.
Engineering at SLAC: Designing and Constructing Experimental Devices for SSRL - Oral Presentation [Slides]
This presentation describes the design and construction of three experimental devices for the Stanford Synchrotron Radiation Lightsource.
An Energy Tunable X-ray Delay Device – Phase I CRADA No.: SLAC-261
Explore the source record for details and available documents.
SLAC HOM Prototype Chassis and ML Training Results
Explore the source record for details and available documents.
Measurements of Time-Dependent CP-Asymmetry Parameters in B Meson Decays to η' K 0 and of Branching Fractions of SU(3) Related Modes with BaBar Experiment at SLAC
In this thesis work we have measured the following upper limits at 90% of confidence level, for B meson decays (in units of 10 -6 ), using a statistics of 465.0 x 10 6 B$\bar{B}$ pairs: β(B 0 → ηK 0 ) < 1.6 β(B 0 → ηη) < 1.4 β(B 0 → η'η') < 2.1 β(B 0 → ηΦ) < 0.52 β(B 0 → ηω) < 1.6 β(B 0 → η'Φ) < 1.2 β(B 0 → η'ω) < 1.7 We have no observation of any decay mode, statistical significance for our measurements is in the range 1.3-3.5 standard deviation. We have a 3.5σ evidence for B → ηω and a 3.1 σ evidence for B → η'ω. The absence of observation of the B 0 → ηK 0 open an issue related to the large difference compared to the charged mode B + → ηK + branching fraction, which is measured to be 3.7 ± 0.4 ± 0.1 [118]. Our results represent substantial improvements of the previous ones [109, 110, 111] and are consistent with theoretical predictions. All these results were presented at Flavor Physics and CP Violation (FPCP) 2008 Conference, that took place in Taipei, Taiwan. They will be soon included into a paper to be submitted to Physical Review D. For time-dependent analysis, we have reconstructed 1820 ± 48 flavor-tagged B 0 → η'K 0 events, using the final BABAR statistic of 467.4 x 10 6 B$\bar{B}$ pairs. We use these events to measure the time-dependent asymmetry parameters S and C. We find S = 0.59 ± 0.08 ± 0.02, and C = -0.06 ± 0.06 ± 0.02. A non-zero value of C would represent a directly CP non-conserving component in B 0 → η'K 0 , while S would be equal to sin2β measured in B 0 → J/ΨK s 0 [108], a mixing-decay interference effect, provided the decay is dominated by amplitudes of a single weak phase. The new measured value of S can be considered in agreement with the expectations of the 'Standard Model', inside the experimental and theoretical uncertainties. Inconsistency of our result for S with CP conservation (S = 0) has a significance of 7.1 standard deviations (statistical and systematics included). Our result for the direct-CP violation parameter C is 0.9 standard deviations from zero (statistical and systematics included). Our results are in agreement with the previous ones [18]. Despite the statistics is only 20% larger than the one used in previous measurement, we improved of 20% the error on S and of 14% the error on C. This error is the smaller ever achieved, by both BABAR and Belle, in Time-Dependent CP Violation Parameters measurement is a b → s transition.