Southern Hemisphere Lidar Measurements of the Aerosol Clouds from Mt. Pinatubo and Mt. Hudson

On 19 Jul., 1991, during tests to determine the ability of the newly-modified CSIRO Ns:YAG lidar to measure signals from the stratosphere before the arrival of dust from the eruption of Mt. Pinatubo, a strongly scattering layer was detected at an altitude of 2 km. That evening, the spectacular sunset and twilight were typical of volcanically disturbed conditions. Lidar measurements at 532 nm were made between 1400 and 1500 EST (0400-0500 UT) on 19 Jul. through broken cloud. Approximately 3800 laser firings were averaged in 256 shot blocks. These and subsequent data have been analyzed to produce profiles of aerosol volume backscatter function and scattering ratio. Clouds again prevented a clear view of the twilights on the next two nights, although there was some evidence for an enhanced glow. The evidence suggested that the aerosol layer had disappeared. An explanation for this disappearance and the earlier than expected arrival of the layer over Melbourne was required. Nimbus 7 TOMS data for 23 Jun. showed that the SO2 from the eruption had extended at least 11000 km to the west and that the southern boundary of the cloud had reached 15 degrees S just 8 days after the climactic eruption. It can be assumed that this cloud also contained dust and sulphuric acid aerosol. It was proposed that a section had then been broken away from the main cloud and carried south by a large scale eddy between the low latitude easterlies and the strong mid-latitude westerlies which finally carried the aerosol cloud over southern Australia. Accompanying 30 mb wind data showed a counter clockwise circulation, responsible for the transport, located in the South Atlantic Ocean.

Young, Stuart A.↗

Application of global positioning system to determination of tectonic plate movements and crustal deformations

It is shown that pseudo-range measurements to four GPS satellites based on correlation of the pseudo random code transmissions from the satellites can be used to determine the relative position of ground stations which are separated by several hundred kilometers to a precision at the centimeter level. Carrier signal measurements during the course of passage of satellites over a pair of stations also yield centimeter precision in the relative position, but oscillator instabilities limit the accuracy. The accuracy of solutions based on either type of data is limited by unmodeled tropospheric refraction effects which would reach 5 centimeters at low elevation angles for widely separated stations.

Anderle, R. J.↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

Effects of spacecraft reflections on RF interferometer position location accuracy

This report describes one of three study tasks related to the application of an RF interferometer aboard a low-orbiting spacecraft to determine the location of ground-based transmitters. Computer modeling was used to estimate the error in the measured signal angle-of-arrival caused by reflection and diffraction off the spacecraft. Existing computer codes (NEC-BSC) were modified and used to determine the perturbation, due to the spacecraft, in the phase difference between two interferometer antennas, suspended on either side of the spacecraft. This phase perturbation was found as a function of the angle-of-arrival of the signal from a far-field source. The spacecraft antennas were assumed to be circularly polarized with a cardioid pattern. It was found that the perturbation was as much 12.4 deg within the + or - 60 deg field-of-view. This suggests that phase calibration and correction of phase measurements are essential for precision position location using this technique.

Wallace, R. G.↗

Interpretation of the optical and morphological properties of Cirrus clouds from lidar measurements

Lidar measurements can provide a great deal of information about the structure, location, and scattering properties of cirrus clouds. However, caution must be used when interpreting raw lidar backscatter profiles in terms of relative or absolute extinction distribution, internal cloud structure, and, at times, cloud location. The problem arises because the signal measured from a range by any monostatic lidar system depends on the backscatter cross section at that range and the 2-way optical thickness to the scattering volume. Simple lidar systems, however, produce only one measurement of attenuated backscatter from each range. The general FIRE research community is given aid in interpretation of lidar measurements, and the special capabilities of the High Spectral Resolution Lidar (HSRL) is explained. Some examples are given of conditions under which direct interpretation of cirrus cloud morphology from simple lidar profiles could be misleading.

Grund, Christian John↗

The Effects of Buoyancy and Dilution on the Structure and Lift-off of Coflow Laminar Diffusion Flames

The ability to predict the coupled effects of complex transport phenomena with detailed chemical kinetics in diffusion flames is critical in the modeling of turbulent reacting flows and in understanding the processes by which soot formation and radiative transfer take place. In addition, an understanding of the factors that affect flame extinction in diffusion flames is critical in the suppression of fires and in improving engine efficiency. The goal of our characterizations of coflow laminar diffusion flames is to bring to microgravity the multidimensional diagnostic tools available in normal gravity, and in so doing provide a broader understanding of the successes and limitations of current combustion models. This will lead to a more detailed understanding of the interaction of convection, diffusion and chemistry in both buoyant and nonbuoyant environments. As a sensitive marker of changes in the flame shape, the number densities of excited-state CH (A(exp 2)delta, denoted CH*), and excited-state OH (A(exp 2)Sigma, denoted OH*) are measured in mu-g and normal gravity. Two-dimensional CH* and OH* number densities are deconvoluted from line-of-sight chemiluminescence measurements made on the NASA KC-135 reduced-gravity aircraft. Measured signal levels are calibrated, post-flight, with Rayleigh scattering. Although CH* and OH* kinetics are not well understood, the CH*, OH*, and ground-state CH distributions are spatially coincident in the flame anchoring region. Therefore, the ground-state CH distribution, which is easily computed, and the readily measured CH*/OH* distributions can be used to provide a consistent and convenient way of measuring lift-off height and flame shape in the diffusion flame under investigation. Given that the fuel composition affects flame chemistry and that buoyancy influences the velocity profile of the flow, we have the opportunity to computationally and experimentally study the roles of fluids and chemistry. In performing this microgravity study, improvements to the computational model have been made and new calculations performed for a range of gravity and flow conditions. Furthermore, modifications to the experimental approach were required as a consequence of the constraints imposed by existing microgravity facilities. Results from the computations and experiments are presented in the following sections.

Walsh, Kevin T.↗

Noise-canceling quantum feedback: Non-Hermitian dynamics with applications to state preparation and magic state distillation

Time-continuous quantum measurement allows for the tracking of a quantum system in real time via sequences of short, and individually weak, measurement intervals. Such measurements are necessarily invasive, imparting backaction to the system, and allowing the observer to update their state estimate based on stochastic measurement outcomes. Feedback control then involves real-time interventions by an observer, conditioned on the time-continuous measurement signal that they receive. Here, we consider here diffusive quantum trajectories and focus on the “noise-canceling” subset of feedback protocols that aim to minimize the degree of stochasticity in the dynamics. We derive such a class of feedback operations, showing that under the idealized assumptions of pure states, unit measurement efficiency, and zero time delay in implementing feedback operations, perfectly noise-canceling feedback always exists. We consider the resulting noise-canceled dynamics generated by an effective non-Hermitian Hamiltonian; while non-Hermitian Hamiltonians from continuous monitoring generally describe rare dynamics (accessible by costly postselection), the use of noise-canceling feedback here leads to non-Hermitian dynamics that occur deterministically. We demonstrate this via examples of entangled state preparation and stabilization. We then illustrate the potential for the application of noise cancellation to boost success rates in magic state distillation protocols. We show that adding feedback based on noise cancellation into a time-continuous five-to-one distillation protocol leads to higher probabilities of successful distillation across a range of input errors and increases the threshold on input errors for which the protocol is effective. Our results highlight the efficacy of noise-canceling feedback-aided protocols for quantum state preparation and stabilization tasks.

Karmakar, Tathagata [University of California, Ber↗

Preliminary dynamic tests of a flight-type ejector

A thrust augmenting ejector was tested to provide experimental data to assist in the assessment of theoretical models to predict duct and ejector fluid-dynamic characteristics. Eleven full-scale thrust augmenting ejector tests were conducted in which a rapid increase in the ejector nozzle pressure ratio was effected through a unique facility, bypass/burst-disk subsystem. The present work examines two cases representative of the test performance window. In the first case, the primary nozzle pressure ration (NPR) increased 36 percent from one unchoked (NPR = 1.29) primary flow condition to another (NPR = 1.75) over a 0.15 second interval. The second case involves choked primary flow conditions, where a 17 percent increase in primary nozzle flowrate (from NPR = 2.35 to NPR = 2.77) occurred over approximately 0.1 seconds. Although the real-time signal measurements support qualitative remarks on ejector performance, extracting quantitative ejector dynamic response was impeded by excessive aerodynamic noise and thrust stand dynamic (resonance) characteristics. It does appear, however, that a quasi-steady performance assumption is valid for this model with primary nozzle pressure increased on the order of 50 lb(sub f)/s. Transient signal treatment of the present dataset is discussed and initial interpretations of the results are compared with theoretical predictions for a similar Short Takeoff and Vertical Landing (STOVL) ejector model.

Drummond, Colin K.↗

Measuring radio-signal power accurately

Absolute value of signal power in weak radio signals is determined by computer-aided measurements. Equipment operates by averaging received signal over several-minute period and comparing average value with noise level of receiver previously calibrated.

Goldstein, R. M.↗

Fluidic angular velocity sensor

A fluidic sensor providing a differential pressure signal proportional to the angular velocity of a rotary input is described. In one embodiment the sensor includes a fluid pump having an impeller coupled to a rotary input. A housing forming a constricting fluid flow chamber is connected to the fluid input of the pump. The housing is provided with a fluid flow restrictive input to the flow chamber and a port communicating with the interior of the flow chamber. The differential pressure signal measured across the flow restrictive input is relatively noise free and proportional to the square of the angular velocity of the impeller. In an alternative embodiment, the flow chamber has a generally cylindrical configuration and plates having flow restrictive apertures are disposed within the chamber downstream from the housing port. In this embodiment, the differential pressure signal is found to be approximately linear with the angular velocity of the impeller.

Berdahl, C. M.↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

The SASS scattering coefficient algorithm

This paper describes the algorithms used to convert engineering unit data obtained from the Seasat-A satellite scatterometer (SASS) to radar scattering coefficients and associated supporting parameters. A description is given of the instrument receiver and related processing used by the scatterometer to measure signal power backscattered from the earth's surface. The applicable radar equation used for determining scattering coefficient is derived. Sample results of SASS data processed through current algorithm development facility (ADF) scattering coefficient algorithms are presented which include scattering coefficient values for both water and land surfaces. Scattering coefficient signatures for these two surface types are seen to have distinctly different characteristics. Scattering coefficient measurements of the Amazon rain forest indicate the usefulness of this type of data as a stable calibration reference target.

Bracalente, E. M.↗

On-Orbit Calibration Assessment of NOAA-21 VIIRS Thermal Emissive Bands and Implications for JPSS-4 VIIRS

The Visible Infrared Imaging Radiometer Suite (VIIRS) instrument onboard the NOAA-21 (N21) satellite has been successfully operating for over three years collecting valuable scientific measurements. A large suite of weather forecasting models and scientific research applications are supported with the VIIRS measurements from N21 combined with those acquired from the VIIRS instrument onboard the S-NPP and NOAA-20 spacecraft. Among the 22 VIIRS spectral bands, there are seven thermal emissive bands (TEB) covering the 3.7 to 12.2 µm spectral range at two different spatial resolutions. The VIIRS TEB detectors are calibrated onboard using a blackbody at a controlled temperature and a space view for background signal measurement. In this paper, we discuss the on-orbit performance of the N21 VIIRS TEB using various parameters such as the detector gain, noise, and offset. This on-orbit assessment provides critical insights into instrument behavior and calibration performance that will inform pre-launch testing and post-launch validation strategies for the upcoming JPSS-4 VIIRS mission scheduled for launch in 2027. The methodologies and lessons learned from characterizing the N21 TEB performance will enable more efficient and comprehensive radiometric assessment of the next VIIRS instrument. Specific focus is placed on identifying performance trends and anomaly signatures observed during the N21 commissioning phase that can enhance the JPSS4 instrument checkout procedures and accelerate the transition to routine on-orbit operations. The established performance baselines and uncertainty estimates will serve as an acceptance criterion for the JPSS-4 commissioning activities, ensuring mission readiness and data continuity for operational users.

Amit Angal↗

Mobile satellite system propagation measurements at L-band using Marecs-B2

A mobile satellite system (MSS) propagation experiment at 1.5 GHz was performed near the east coast of the United States in central Maryland during December 1987 using the Marecs-B2 satellite as a transmitter platform. A receiving system in a vehicle measured signal fades caused by shadowing and multipath from roadside trees and utility poles. The propagation degradations were characterized for a system of three roads previously examined using a helicopter as the transmitter platform. The objectives of the Marecs-B2 MSS tests were to: (1) establish cumulative fade distributions for the particular satellite geometry for both rural and suburban roads; (2) validate the consistency of previous roadside tree measurements which employed a helicopter as the transmitter platform for the same system of roads; (3) obtain an additional set of fade levels at a lower angle hitherto not measured in central Maryland; and (4) combine the satellite-acquired data set with previous helicopter results and establish an analytic, empirically derived function describing the cumulative fade distributions for a family of path angles. An analysis of the satellite data has demonstrated the successful achievement of these objectives.

Vogel, Wolfhard J.↗

Strainmeters and tiltmeters in geophysics

Several types of sensitive strainmeters and tiltmeters have been developed, and it is now becoming clear which geophysical applications are most suitable for these instruments. In general, strainmeters and tiltmeters are used for observing ground deformation at periods of minutes to days. Small-scale lateral inhomogeneities at the instrument sites distort signals by a few percent, although the effects of large structures can be calculated. In earth tide work these lateral inhomogeneities and unknown ocean loading signals prevent accurate values of the regional tide from being obtained. This limits tidal investigations to looking for temporal variations, possibly associated with pre-earthquake dilatancy, and spatial variations caused by gross elasticity contrasts in the local geological structure. Strainmeters and tiltmeters are well suited for observing long-period seismic waves, seismic slip events on faults and volcano tumescence, where small site-induced distortions in the measured signals are seldom important.

Goulty, N. R.↗

Develop advanced nonlinear signal analysis topographical mapping system

As reported in the monthly technical progress report for July 1993, a new signal analysis technique called instantaneous frequency correlation (IFC) for time delay estimation was developed which will be incorporated into the ATMS system. In this report, a different technique for time delay estimation called phase difference time derivative estimator (FDTDE) will be discussed. The FDTDE technique does not replace the IFC method since their application conditions are different. The IFC technique can estimate the time delay between two spectral components of two measurement signals when the center frequency of the components is constant, while the FDTDE method can provide accurate time delay estimation when the frequency of the subject component changes linearly such as during engine startup or shut-down.

Jong, Jen-Yi↗

Rotationally Vibrating Electric-Field Mill

A proposed instrument for measuring a static electric field would be based partly on a conventional rotating-split-cylinder or rotating-split-sphere electric-field mill. However, the design of the proposed instrument would overcome the difficulty, encountered in conventional rotational field mills, of transferring measurement signals and power via either electrical or fiber-optic rotary couplings that must be aligned and installed in conjunction with rotary bearings. Instead of being made to rotate in one direction at a steady speed as in a conventional rotational field mill, a split-cylinder or split-sphere electrode assembly in the proposed instrument would be set into rotational vibration like that of a metronome. The rotational vibration, synchronized with appropriate rapid electronic switching of electrical connections between electric-current-measuring circuitry and the split-cylinder or split-sphere electrodes, would result in an electrical measurement effect equivalent to that of a conventional rotational field mill. A version of the proposed instrument is described.

Kirkham, Harold↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗