Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SECONDARY FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Deconvoluting sources of variability in aerosol jet printing using light scattering measurements

Aerosol jet printing (AJP) is a digital additive manufacturing technique for hybrid and conformal electronics, where its contactless deposition readily enables patterning over 3D surface topography. However, the complexity of aerosol transport physics makes deposition rate sensitive to process variability, hindering widespread industry adoption. Light scattering measurements have recently been demonstrated as a capable tool for measuring deposition rate in real time, enabling closed-loop control and in-situ qualification frameworks. These inline optical measurements present further opportunity as a diagnostic tool to understand the effects of secondary process parameters affecting vapor–liquid equilibrium and heat and mass transport during deposition. Downstream of the optical measurement cell, changing the sheath gas flow rate, increasing temperature via an inline heater, and adding solvent vapor via a sheath gas bubbler were observed to alter drying physics during sheath-collimation, and thereby impaction efficiency. Further upstream, the introduction of solvent vapor via a carrier gas bubbler and liquid build-up in the printhead were seen to affect the quantitative relationship between the light scattering data and the true deposition rate. Using this information, tightened controls of meaningful secondary parameters were implemented to improve the batch-to-batch consistency for printing a dielectric ink. In addition to advancing AJP process reliability for production, this work demonstrates the capability of inline optical measurements to provide insight into process physics and deconvolute competing mechanisms that underly variability.

additive manufacturing↗

Faster-than-real-time Simulation with Demonstration for Resilient DER Integration

The US electric grid is facing operational, stability, and security challenges. Transmission system operators need some measure of visibility into distribution system renewable generation. Distribution system generation needs to support transmission system voltage. The grid is experiencing an expansion in measurement systems. How to take full advantage of this expansion and defend against attacks, both cyber and physical, poses additional challenges. The Faster-than-real-time Simulation with demonstration for Resilient DER Integration project set out to do the following: a. Flatten the voltage profile through the feeders and system for cost saving and voltage stabilization needs. b. Increase the amount of intermittent distributed energy resources (IDERs) that could be deployed on a utility feeder and provide 100% or more energy needed for the demands on that feeder, and c. based on an accurate model (Digital Twin) of the utilities system, be able to detect any abnormalities on the utilities distribution system. To manage the voltage and increase IDER penetration (a,b), Graph Trace Analysis is employed in a time-series, optimal power flow to coordinate the time-varying feedback control setpoints of a distribution feeder’s utility control devices. Under the coordinated control are a Load Tap Changing Transformer, a voltage regulator, and five switched capacitor banks. The feeder serves over 2000 customers, the feeder secondaries are modeled, and the feeder has 2.3 MW of PV generation, corresponding to a 17.4% penetration of PV generation. The feeder model has over 12,000 components, where every customer load bus and PV generator are modeled. The accuracy of the power flow solution is compared against historical meter voltage measurements, the improvement in conservation voltage reduction energy savings as a function of the coordinated control desired voltage profile is investigated, and the increase in PV penetration of the coordinated control over the existing control is presented. To achieve improved control performance while observing system operation constraints, bellwether Advanced Metering Infrastructure (AMI) voltage measurements are used to adjust the desired voltage profile used by the optimal power flow analysis. To detect and alleviate or negate attacks or failures on the distribution and transmission utility grids (c) the grid needs to be resilient and self-healing. In this project software was designed to do just that. At the center of the software is an Integrated System Model (ISM) that spans from transmission to secondary distribution. The ISM is employed in real-time abnormality detection, voltage stability forecasting, and multi-mode control. Testing results are presented for: 1—attacks on utility infrastructure; 2—energy savings from optimal control; 3—distribution system control response during a low voltage transmission system event; 4—cyber-attacks on PV inverters, where physical inverters are used in hard-ware-in-the-simulation-loop studies. Contributions of this work include real-time analysis that spans from three-phase transmission through secondary distribution; an approach for detecting abnormalities that employs measurements from three independent measurement systems; and a multi-mode distribution system control that responds to cyber-attacks, physical attacks, equipment failures, and transmission system needs.

Integrated System Model, Graph Trace Analysis, Adv↗

Wear in particle based CSP systems from particle abrasion and attrition at high temperature

High temperature particle-based receivers offer distinct advantages over conventional molten salt receivers due to their ability to achieve temperatures above 700 ºC, direct absorption of solar energy as they fall through a beam of concentrated sunlight, and the relative ease of storage (and retrieval using a secondary working fluid) in insulated storage tanks. The use of particles, however, also raises concerns with material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. The flow of particles over surfaces may result in loss of material from abrasive wear, impact erosion from impingement under gravitational fall and particle attrition as particles fall and move on top of each other. In the present study, the performance of candidate materials and particles were evaluated through a series of abrasion erosion and particle attrition experiments at room temperature as well as at 800 °C. Candidate materials were subject to abrasive wear from particles at low particle to material velocities inside a resistance heated kiln, and analyzed for changes in mass and surface morphology using cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) tests. The wear rate for different specimens was noted to be largely driven by the strength of chromia scales built on the specimens from exposure to high temperature. Particle attrition measurements explored the susceptibility of particles to breakdown from particle to particle interaction and the generation of fines from this process. At the low velocities expected in particle based CSP plants, the particles tested exhibited near negligible breakdown. However, changes in the particle hardness at 800 ºC resulted in a significantly higher particle breakdown to sizes <40 microns raising potential environmental concerns. In addition to particle breakdown, it was also noted that the sample had oxides from the stainless steel test setup mixed in with the particles. Similar oxides can be expected to turn up in the utility scale particle based CSP plants as well. The presence of oxide was also noted to affect the solar absorptivity of the mixture compared to a clean initial specimen, potentially resulting in a change in the overall efficiency of the CSP plant.

14 SOLAR ENERGY↗

Special Analyses for the Hanford Integrated Disposal Facility Performance Assessment - 20102

In 2014, the Department of Energy (DOE) Office of River Protection and its contractors began to develop a performance assessment for the near-surface disposal of low-level and mixed low-level waste at the Hanford Site's Integrated Disposal Facility (IDF). The IDF is a doubly-lined landfill that was constructed between 2004 and 2006 to be the disposal facility for the vitrified low-activity waste that will be produced at the Waste Treatment and Immobilization Plant (WTP). IDF is also expected to receive solid secondary waste produced at the WTP and other solid wastes from site activities. The IDF has been in a preoperational state awaiting authorization from DOE and a RCRA permit modification from the State of Washington Department of Ecology to receive waste. Both the Disposal Authorization Statement and permit modification require a performance assessment demonstrating that the system of engineered and natural features will limit releases of radionuclides and hazardous chemicals from the IDF and be protective of human health and the environment. The simulated duration is 10,000 years. Based on the analyses presented in the 2017 Integrated Disposal Facility Performance Assessment, DOE issued a conditional Operating Disposal Authorization Statement for the IDF in June 2018. The long-term performance of the IDF to be protective of human health and the environment was evaluated under the requirements of DOE Order 435.1, Radioactive Waste Management. Computer simulations were performed to evaluate whether or not the IDF would comply with DOE requirements. In the time that has passed since the performance assessment was approved by DOE, new information has been discovered that had not been considered in the performance assessment. Since this new information has not been evaluated, the potential impact of the changes have not been taken into consideration in DoE's disposal authorization. DOE and its contractors follow a change control process to screen and, when necessary, evaluate new information that could potentially impact the conclusions of the completed performance assessment. This paper will describe the change control process and provide two examples of evaluations performed following the change control process. The first example evaluates a new waste form for liquid secondary waste that was not evaluated in the performance assessment. In the performance assessment, liquid secondary waste was assumed to be solidified with grout. A new recommendation to dispose of the liquid secondary waste after drying it to a powder was evaluated. The second example evaluates inventory implications from changes to the flow sheet that estimates the feed composition to the low-activity waste vitrification facility. The changes result in higher strontium concentrations in the vitrified waste stream. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antibacterial and antioxidant activities of Streptomyces sp. strain FR7 isolated from forest soil

Abstract Actinomycetes produce secondary metabolites with many bioactivities such as antimicrobial, which can be useful as alternatives against resistant bacterial strains. Therefore, the screening of new habitats is likely to provide new strains with high potential. In this work, the antimicrobial capacity was used to select Streptomyces sp. strains isolated from Raf Raf forest (Tunisia). From the strain displaying higher activity, FR7, an ethyl acetate extract was prepared under optimized culturing conditions (10 days at 30°C in ISP2 medium with initial pH 8), showing significant antimicrobial activity against Micrococcus luteus and Staphylococcus aureus (MIC = 5 μg ml−1), and Listeria monocytogenes and Pseudomonas aeruginosa (MIC = 20 μg ml−1). The extract displayed strong DPPH radical scavenging activity (IC50 = 1.3 μg ml−1) and protection of yeast cells from H2O2-induced oxidative stress determined by flow cytometry with dichlorofluorescein diacetate. The crude extract showed the presence of polyketides, with methylsalicylic acid as moiety, a large and diverse group of secondary metabolites with a wide range of bioactivities, including antioxidant and antibacterial. Based on 16S RNA gene sequences, strain FR7 was identified as belonging to genus Streptomyces with high resemblance to S. iakyrus. Streptomyces sp. FR7 has great potential as a source of antibacterial and antioxidant metabolites.

Weslati, Imen↗

Wavelet flow for extragalactic foreground simulations

Extragalactic foregrounds in cosmic microwave background (CMB) observations are both a source of cosmological and astrophysical information and a nuisance to the CMB. Effective field-level modeling that captures their non-Gaussian statistical distributions is increasingly important for optimal information extraction, particularly given the low-noise observations from current and upcoming experiments. Here, we explore the use of Wavelet Flow (WF) models to tackle the novel task of modeling the field-level probability distributions of multi-component CMB secondaries and foregrounds. Specifically, we jointly train correlated CMB lensing convergence (κ) and cosmic infrared background (CIB) maps with a WF model and obtain a network that statistically recovers the input to high accuracy — the trained network generates samples of κ and CIB fields whose average power spectra are within a few percent of the inputs across all scales, and whose Minkowski functionals are similarly accurate compared to the inputs. Leveraging the multiscale architecture of these models, we fine-tune both the model parameters and the priors at each scale independently, optimizing performance across different resolutions. These results demonstrate that WF models can accurately simulate correlated components of CMB secondaries, supporting improved analysis of cosmological data. Our code and trained models can be found on this GitHub repo.

cosmological simulations↗

The SAS4A/SASSYS-1 Version 5.8 Safety Analysis Code System

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. Detailed, mechanistic models of steady-state and transient thermal, hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems, and the balance-of-plant to accidents caused by changes in coolant flow, loss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions, or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options, including lead, LBE, and water.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Combustor with dual pressure premixing nozzles

A combustor may include a combustor liner and flow sleeve. A high pressure air cools an outer surface of the combustor liner via openings in the flow sleeve, creating a lower pressure air in an annulus between the combustor liner and the flow sleeve. A first fuel nozzle is positioned at a primary combustion zone, and a second fuel nozzle is positioned at a secondary combustion zone of the liner. A fuel source is configured to deliver a fuel to the fuel nozzles. The fuel nozzles produce a premixture of high pressure air and the fuel, and produce a mixture of the premixture and the lower pressure air, prior to introducing the mixture to a respective primary or secondary combustion zone of the combustor. The combustor provides improved fuel premixing and is fuel flexible, and reduces pressure drop requirements. The combustor is usable in a can, annular, or segmented annular combustor assembly.

Berry, Jonathan Dwight↗

Thermal Hydraulic Experimental Test Article (FY2020 Status Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA will be installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2. The design work for the facility has been completed. Since the FY19 THETA status report, the THETA primary system components have been assembled and tested using de-ionized water. Some results of this testing at select Richardson and Reynolds numbers are included herein. The custom THETA sodium flowmeter (permanent magnet submersible sodium flowmeter) has been built and calibrated using sodium in an auxiliary facility against a NIST traceable vortex shedder type flowmeter. The permanent magnet flowmeter showed excellent performance, following the theoretical equation for measured voltage quite well, with an error < 3.5% at flow rates ranging from 3-24 GPM at temperatures up to 400 °C. The secondary sodium system for heat rejection from intermediate heat exchanger has been analyzed according to ASME code. All secondary side piping, fittings and a U-stamped air-to-sodium heat exchanger have been procured.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modular Power Electronics Approach for High Power Dynamic Wireless Charging System

Dynamic wireless power transfer (DWPT) can provide energy to EVs in motion and extend the drive range. Upscaling the charging power to 200 kW (High Power DWPT) reduces the percentage of electrified roadway required, and the solution becomes cost-effective. To smooth the power at the battery and grid, a secondary regulation stage must be added. The DWPT system therefore relies on power electronics to interface with the coils and regulate the power flow. Designing this high power system using wide bandgap devices makes ensuring high efficiency, small size, and reliable operation very challenging, and significant engineering effort is required to build such complicated systems for large-scale installation and deployment. Here, this paper describes a modular design approach for the power electronics to achieve the 200 kW wireless power transfer. As described, the SiC power electronics building block is designed, simulated, and characterized. The approach is validated in the DWPT system to build the inverter, the rectifier, and the DC/DC converter, which demonstrated high performance and reliable operation with 188 kW power.

42 ENGINEERING↗

Transient uncertainty quantification and Global Sensitivity Analysis of the open-source Molten Chloride Reactor Experiment (MCRE) using GP-PCA surrogate models

Uncertainties in the thermophysical properties of molten salts impact both the steady-state and transient behavior of Molten Salt Reactors (MSRs). In this work, we aim to quantify the influence of such uncertainties on the transient operation of the Molten Chloride Reactor Experiment (MCRE), utilizing the open-source specifications provided for this reactor. Seven representative transient scenarios are considered. For each scenario, we evaluate the impact of thermophysical property uncertainties on four key multiphysics model output variables of interest (VoIs): maximum power density, maximum fuel temperature, maximum reflector temperature, and average fuel velocity magnitude. In addition, we perform a Global Sensitivity Analysis (GSA) by computing Sobol’ indices for the uncertain input parameters to determine their contribution to the variability of each VoI. Conducting GSA is computationally intensive due to the large number of required evaluations of the high-fidelity multiphysics model. To mitigate this cost, we develop a surrogate modeling framework that combines Gaussian Process (GP) regression with Principal Component Analysis (PCA), enabling efficient sample generation for the GSA. Our results show that for energy-related VoIs, thermal conductivity is the dominant contributor to uncertainty. In contrast, for flow-related VoIs, density and dynamic viscosity are the primary sources of uncertainty. The specific heat of the fuel salt was found to play a secondary role in the transient analyses.

42 - ENGINEERING↗

Dynamic Earthquake Triggering in Southern California in High Resolution: Intensity, Time Decay, and Regional Variability

Abstract Earthquake triggering by seismic waves has been recognized as a phenomenon for nearly 30 years. However, our ability to study dynamic triggering has been limited by our ability to capture the triggering stresses accurately and record the resultant earthquakes. Here we use full waveforms from a dense seismic network and a modern, high‐resolution seismic catalog to measure triggering in Southern California from 2008 to 2017 based on interevent time ratios. We find that the fractional seismicity rate change, which we term triggering intensity or triggerability, as a function of peak strain change for the period of ∼20 s due to distant earthquakes is monotonically increasing and compatible with earlier measurements made with a disjoint data set from 1984 to 2008. A triggering strain of 1 microstrain is equivalent to the local productivity generated by an M 1.8 earthquakes. This result implies that a prediction of seismicity rate changes can be made based on recorded ground shaking using the same formalism as currently used for aftershock prediction. For a teleseismic event, this small level of triggering occurs throughout the region and thus aggregates to a regional effect. We find that the triggering rate decays after the triggerer follows an Omori‐Utsu law, but at a much slower rate than a typical aftershock sequence. The slow decay rate suggests that an ancillary process such as creep or fluid flow must be part of dynamic triggering. The prevalence of triggering in areas of creep or fluid involvement reinforces this inference. A triggering cascade of secondary earthquakes is insufficient to explain the data.

Miyazawa, Masatoshi↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Challenges to Reliable Production Nitrogen Doping of Nb for SRF Accelerating Cavities

Over the last several years, alloying of the surface layer of niobium SRF cavities has been demonstrated to beneficially lower the superconducting RF surface resistance. Nitrogen, titanium, and oxygen have all been demonstrated as effective alloying agents, occupying interstitial sites in the niobium lattice within the RF penetration depth and even deeper, when allowed to thermally diffuse into the surface at appropriate temperatures. The use of nitrogen for this function has been often termed ’nitrogen doping’ and is being applied in the LCLS-II and LCLS-II HE projects. We report characterization studies of the distribution of nitrogen into the exposed niobium surface and how such distribution is affected by the quality of the vacuum furnace environment in which the doping takes place, and the complexity of nitride crystal growth on different grain orientations of surface niobium. Using state-of-the-art quantification methods by dynamic secondary ion mass spectrometry (SIMS) depth profiling in niobium, we identify several phenomena involving furnace-sourced contamination. We also highlight a potential issue with N₂ flow constraints from the flange ’caps’ used during heat treatments.

Reece, Charles↗

SPC-70791 Rev 0 MARVEL Inert Gas Subsystem, Secondary Coolant Management Subsystem, and Secondary Coolant Cover Gas Subsystem Tubing and Valve Specification

This specification covers the requirements and details for the selection, testing, cleaning, marking, shipping, inspection and installation (including welding) of the Inert Gas Subsystem, Secondary Coolant Management Subsystem, and Secondary Cover Gas Management Subsystem from the Valve Panel up to the classification division, the patch panel of the upper confinement. Including NaK, argon, eutectic gallium indium tin (eGaInSn), and helium fill tubing, valves, and hangers. These systems consist of the necessary straight lengths, elbows, reducers, fittings, tube connections, instrument taps, and valves called for by applicable drawings. All components shall be procured as ASME Section III Class 2 unless otherwise modified hereinafter. Pressure relief valves have been sized to prevent overpressure in the event there is full regulator flow. This is documented in ECAR-7365.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

On the stability of a pair of vortex rings

The growth of perturbations subject to the Crow instability along two vortex rings of equal and opposite circulation undergoing a head-on collision is examined. Unlike the planar case for semi-infinite line vortices, the zero-order geometry of the flow (i.e. the ring radius, core thickness and separation distance) and by extension the growth rates of perturbations vary in time. The governing equations are therefore temporally integrated to characterize the perturbation spectrum. The analysis, which considers the effects of ring curvature and the distribution of vorticity within the vortex cores, explains several key flow features observed in experiments. First, the zero-order motion of the rings is accurately reproduced. Next, the predicted emergent wavenumber, which sets the number of secondary vortex structures emerging after the cores come into contact, agrees with experiments, including the observed increase in the number of secondary structures with increasing Reynolds number. Finally, the analysis predicts an abrupt transition at a critical Reynolds number to a regime dominated by a higher-frequency, faster-growing instability mode that may be consistent with the experimentally observed rapid generation of a turbulent puff following the collision of rings at high Reynolds numbers.

42 ENGINEERING↗