At least 145 records · Page 8

Influence of Ti and REE on Primary Crystallization and Wear Resistance of Chromium Cast Iron

The article presents the results of primary crystallization, wear resistance and SEM studies of chromium cast iron inoculated with ferrotitanium and rare earth elements as a mischmetal inoculating mixture. Thermal-derivative analysis method was used to conduct studies of primary crystallization in two types of testers, namely ATD-C and ATD-Is, reflecting two different cooling speeds. Wear resistance tests were performed with the use of modified pin-on-disk method on Tribotester 3-POD device, where the samples were moving in circular motion in metal-mineral friction system. Silicon carbide was used as a counter sample. The studies allowed to determine the influence of selected inoculants on the microstructure and wear resistance of the studied samples. All characteristic crystallization temperatures of samples casted into ATD-Is testers increased, as well as wear resistance of each inoculated samples compared to the non-inoculated sample. It was proven that TiC and REE compounds are effective inoculants for chromium carbides and that REE compounds can work as underlay for TiC crystallization.

36 MATERIALS SCIENCE↗

A miniature electron ionization source fabricated using microelectromechanical systems ($\mathrm{MEMS}$) with integrated carbon nanotube ($\mathrm{CNT}$) field emission cathodes and low-temperature co-fired ceramics ($\mathrm{LTCC}$)

The use of microelectromechanical systems (MEMS) components in miniature mass spectrometers is particularly attractive due to their small size and scalable manufacturing capability. Our group has pioneered the development of miniature electron ionization sources combining MEMS fabricated structures with integrated carbon nanotube (CNT) cold-cathode field emitters. However, until now they have been of limited use due to the limited ability to direct the ions into a mass analyzer. In this work, we design a miniature ion source using a microfabricated MEMS device and a low temperature co-fired ceramic (LTCC) carrier that includes electrical connections, ion optics for directing ions out of the device, and a sample inlet. Here we present the design and fabrication of the ion source; simulate the energy and angular dispersion; and experimentally determine the energy and angular dispersion.

47 OTHER INSTRUMENTATION↗

Optimization of the imaging response of scanning microwave microscopy measurements

In this work, we present the analytical modeling and preliminary experimental results for the choice of the optimal frequencies when performing amplitude and phase measurements with a scanning microwave microscope. In particular, the analysis is related to the reflection mode operation of the instrument, i.e., the acquisition of the complex reflection coefficient data, usually referred as S{sub 11}. The studied configuration is composed of an atomic force microscope with a microwave matched nanometric cantilever probe tip, connected by a λ/2 coaxial cable resonator to a vector network analyzer. The set-up is provided by Keysight Technologies. As a peculiar result, the optimal frequencies, where the maximum sensitivity is achieved, are different for the amplitude and for the phase signals. The analysis is focused on measurements of dielectric samples, like semiconductor devices, textile pieces, and biological specimens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Carrier recombination parameters in diamond after surface boron implantation and annealing

In this study, an optical pump–probe technique was used to detect spatial distribution of carrier lifetimes across the thickness of a high-quality diamond device structure. Two samples with as-received and boron implanted surfaces were compared to assess the role of implantation and related processing on carrier recombination mechanisms. It was found that the two implanted surfaces show very different behaviors despite undergoing the same treatment. At one of the surfaces, carrier lifetimes remained relatively unchanged, indicating surface recombination rates in the 102–103 cm/s range. At the other surface, carrier lifetimes were almost a magnitude lower and correlated with the locally detected nitrogen vacancy defect that was attributed to the elevated concentration of residual nitrogen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian Framework for Multi-Timescale State Estimation in Low-Observable Distribution Systems

To support the smart grid paradigm, there has been a significant increase in sensor deployments and metering infrastructure in distribution systems. However, the measurements provided by these sensors and metering devices are typically sampled at different rates and could suffer from losses during the aggregation process. It is crucial to effectively reconcile the time-series measurements for a reliable state estimation. While weighted least squares has been the traditional approach for state estimation, sparsity-based approaches like matrix completion have become popular due to their superior performance in low-observability conditions. This paper proposes a Bayesian framework for both multi-timescale data aggregation and matrix completion based state estimation. Specifically, the multiscale time-series data aggregated from heterogenous sources are reconciled using a multitask Gaussian process that exploits the spatio-temporal correlations. Here, the resulting consistent timeseries alongwith the confidence bound on the imputations are fed into a Bayesian matrix completion method augmented with linearized power-flow constraints to accurately estimate the states in low-observability conditions. Results on three phase unbalanced IEEE 37 and IEEE 123 bus test systems reveal the superior performance of the proposed Bayesian framework. The computational complexity for the proposed Bayesian framework is also quantified.

42 ENGINEERING↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

Synthesis and Analysis of Glass Analogs for Solid Fallout Debris

Following a nuclear detonation, radiochemists and post-detonation debris diagnosticians are tasked with performing high-quality analysis of fallout debris samples and accurate device interpretation. Debris formed following a nuclear detonation commonly consists of a heterogeneous glassy matrix containing uranium, plutonium, neptunium, americium, and fission/activation products. Homogeneous and well-characterized reference materials are critical for accurate post-detonation debris analysis. Such reference materials can include aged nuclear explosion debris from the Nevada Test Site (e.g., Trinitite) as well as 'fresh' doped-glass material. Recent work has highlighted the often heterogeneous nature of historical debris, which presents a problem from the aspects of safeguards accountancy and verification as well as micro-scale characterization (i.e., microbeam analysis). In this regard, our work focuses on the creation of homogeneous, 'fresh' doped-glassy standards containing uranium, plutonium, surrogate fission products (e.g., Sr, Cs, Pm, Sm, Eu), and urban material (e.g., Fe and Ca from construction material, stainless steel, aluminosilicates phases as a surrogate for dirt). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Developments of solid materials for UF 6 sampling

This project demonstrated that a device using majority Commercial Off the Shelf (COTS) components could be used to collect uranium hexafluoride samples safely from gaseous or solid sources. The device was based on the successful Cristallini method developed by ABACC over the past 10 years. The system was designed to capture and store the UF 6 as an inert fluoride salt to ease transportation regulations. In addition, the method was considerably faster than traditional cryogenic methods, collected enough material to perform analyses without undue waste, and could be used either inside a facility or in the storage yard.

36 MATERIALS SCIENCE↗

KBase Narrative - Atacama Trench & Sn Clemente 2018 cruise Metagenomes -Decontamination through Metagenomic Fractionation and analysis of Metabolic Potential-

Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.

Plominsky, Alvaro M.↗

KBase Narrative - Atacama Trench & Sn Clemente 2018 cruise Metagenomes -Sequence quality filtration & Assembly-

Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.

Plominsky, Alvaro M.↗

Compact spherical neutron polarimeter using high-T{sub c} YBCO films

We describe a simple, compact device for spherical neutron polarimetry measurements at small neutron scattering angles. The device consists of a sample chamber with very low (<0.01 G) magnetic field flanked by regions within which the neutron polarization can be manipulated in a controlled manner. This allows any selected initial and final polarization direction of the neutrons to be obtained. We have constructed a prototype device using high-T{sub c} superconducting films and mu-metal to isolate regions with different magnetic fields and tested device performance in transmission geometry. Finite-element methods were used to simulate the device’s field profile and these have been verified by experiment using a small solenoid as a test sample. Measurements are reported using both monochromatic and polychromatic neutron sources. The results show that the device is capable of extracting sample information and distinguishing small angular variations of the sample magnetic field. As a more realistic test, we present results on the characterization of a 10 μm thick Permalloy film in zero magnetic field, as well as its response to an external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of alternative filter media for particulate matter emission testing of residential wood heating devices

The performance of Teflon-coated glass fiber filter media (Pallflex Emfab TX40) is evaluated for particulate matter (PM) sampling of residential wood heating devices in a dilution tunnel. Thirty samples of varying duration and PM loading and concentration were collected from an U.S. Environmental Protection Agency (EPA) Method 28 dilution tunnel using dual Method 5G sample trains with untreated glass fiber and Emfab filters. Filters were weighed soon after the end of sampling and again the next day after equilibration at 35% relative humidity (RH). PM concentrations from both types of filters agreed very well with 1-day equilibration, demonstrating that Emfab filters are appropriate for use in measuring PM from residential wood burning appliances in a dilution tunnel and have performance equal to or better than the glass fiber filter media. Agreement between filter media without equilibration was erratic, with PM from glass fiber filter samples varying from slightly less than the Emfab samples to as much as 2.8 times higher. Some of the glass fiber filters lost substantial mass with equilibration, with the highest percent loss at lower filter mass loadings. Mass loss for Emfab samples was a small percentage of the mass and very consistent across the range of mass loadings. Taken together, these results may indicate water uptake on the glass fiber media that is readily removed with 1-day equilibration at moderate RH conditions. Implications: EPA regulations now allow the use of either glass fiber or Teflon filter media for wood appliance PM emission testing. Teflon filter media minimizes the potential for acid-gas PM artifacts on glass fiber filters; this is important as EPA moves toward the use of locally sourced cordwood for testing that may have higher sulfur content. This work demonstrates that the use of Teflon-coated glass fiber filters can give similar PM measurement results to glass fiber filters after 1 day of equilibration. With no equilibration, measured PM from glass fiber filters was usually higher than from Teflon-coated glass fiber filters.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multiplexed microfluidic approach for nucleic acid enrichment

A system for enhancing a nucleic acid sample may include a one pump, a denaturing chamber; a microfluidic hydroxyapatite chromatography device configured for performing hydroxyapatite chromatography on the nucleic acid sample, a sample collector, and tubing connecting the pump with the denaturing chamber, the hydroxyapatite chromatography device and the sample collector such that the pump may be used to move the nucleic acid sample from the denaturing chamber to the hydroxyapatite chromatography device and then to the sample collector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temporal Sampling of Enzymes from Live Cells by Localized Electroporation and Quantification of Activity by SAMDI Mass Spectrometry

Abstract Measuring changes in enzymatic activity over time from small numbers of cells remains a significant technical challenge. In this work, a method for sampling the cytoplasm of cells is introduced to extract enzymes and measure their activity at multiple time points. A microfluidic device, termed the live cell analysis device (LCAD), is designed, where cells are cultured in microwell arrays fabricated on polymer membranes containing nanochannels. Localized electroporation of the cells opens transient pores in the cell membrane at the interface with the nanochannels, enabling extraction of enzymes into nanoliter‐volume chambers. In the extraction chambers, the enzymes modify immobilized substrates, and their activity is quantified by self‐assembled monolayers for matrix‐assisted laser desorption/ionization (SAMDI) mass spectrometry. By employing the LCAD‐SAMDI platform, protein delivery into cells is demonstrated. Next, it is shown that enzymes can be extracted, and their activity measured without a loss in viability. Lastly, cells are sampled at multiple time points to study changes in phosphatase activity in response to oxidation by hydrogen peroxide. With this unique sampling device and label‐free assay format, the LCAD with SAMDI enables a powerful new method for monitoring the dynamics of cellular activity from small populations of cells.

Mukherjee, Prithvijit↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗

Task-Specific Ionic Compounds for In-Field Sample Preparation Poster

In the event of a nuclear detonation, actinide and fission product-containing debris can be analyzed to provide information about the nature of the device. In-field sample dissolution prior to transport to a laboratory is critical for reducing the time between an event and delivery of information to decision makers. However, the best dissolution methods utilize liquid strong acid solutions, which are incompatible with field collection Standard Operating Procedure. What is required are solid materials that, when mixed with water in the field, can provide the strong digestion and dissolution properties of nitric and hydrofluoric acids. Fluorohydrogenate ionic liquids have shown a remarkable ability to dissolve a wide range of materials, from refractory actinide oxides to cementitious material such as calcium silicates. These strong dissolution properties are due to the neutral hydrofluoric acid that is bound to the anion component of the ionic liquid. Because these materials are liquids, they are also incompatible with Standard Operating Procedure. However, the physiochemical properties of ionic liquids, such as the melting point, can be readily tuned through minor modification of the molecular structure of the cations and anions. Thus, we hypothesize that by synthesizing modified cations, novel ionic compounds with melting points above ambient but with the same anion and bound hydrofluoric acid – and thus similar digestion and dissolution properties – as current fluorohydrogenate ionic liquids can be produced. These solid materials would be compatible with current Standard Operating Procedure, and would allow for rapid, in-field dissolution of samples, shortening the time to actionable information after an event.