Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evaluation of membrane filter field monitors for microbiological air sampling

Due to area constraints encountered in assembly and testing areas of spacecraft, the membrane filter field monitor (MF) and the National Aeronautics and Space Administration-accepted Reyniers slit air sampler were compared for recovery of airborne microbial contamination. The intramural air in a microbiological laboratory area and a clean room environment used for the assembly and testing of the Apollo spacecraft was studied. A significantly higher number of microorganisms was recovered by the Reyniers sampler. A high degree of consistency between the two sampling methods was shown by a regression analysis, with a correlation coefficient of 0.93. The MF samplers detected 79% of the concentration measured by the Reyniers slit samplers. The types of microorganisms identified from both sampling methods were similar.

Fields, N. D.↗

Electrets used in measuring rocket exhaust effluents from the space shuttle's solid rocket booster during static test firing, DM-3

The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site.

Susko, M.↗

Semivolatile Particulate Organic Material Southern Africa during SAFARI 2000

During August and September 2000, the University of Washington's Cloud and Aerosol Research Group (CARG) with its Convair-580 research aircraft participated in the Southern African Fire-Atmosphere Research Initiative (SAFARI) 2000 field study in southern Africa. Aboard this aircraft was a Particle Concentrator-Brigham Young University Organic Sampling System (PC-BOSS), which was used to determine semivolatile particulate material with a diffusion denuder sampler. Denuded quartz filters and sorbent beds in series were used to measure nonvolatile and semivolatile materials, respectively. Results obtained with the PC-BOSS are compared to those obtained with conventional quartz-quartz and Teflon-quartz filter pack samplers. Various 10-120 min integrated samples were collected during flights through the h e troposphere, in the atmospheric boundary layer, and in plumes from savanna fires. Significant fine particulate semivolatile organic compounds (SVOC) were found in all samples. The SVOC was not collected by conventional filter pack samplers and therefore would not have been determined in previous studies that used only filter pack samplers. The SVOC averaged 24% of the fine particulate mass in emissions from the fires and 36% of the fine particulate mass in boundary layer samples heavily impacted by aged emissions from savanna fires. Concentrations of fine particulate material in the atmospheric mixed layer heavily impacted by aged savanna frre emissions averaged 130 micrograms per cubic meter. This aerosol was 85% carbonaceous mated.

Eatough, D. J.↗

Aerosol Sampling Experiment on the International Space Station

The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.

Aerosol↗

Unlimbering Viking's scoop

A number of difficulties which were encountered in deploying the Viking 1 lander's surface-sampler arm are discussed. When the surface sampler jammed during its initial operation, the problem was studied with the aid of tests on a full-scale lander mock-up. It was found that the difficulty was caused by a boom latch pin which had failed to fall clear. The surface-sampler arm could subsequently be freed by modifying the original command sequence. Another difficulty could be overcome by a similar approach.

Spitzer, C. R.↗

Description and field test of an in situ coliform monitoring system

A prototype in situ system for monitoring the levels of fecal coliforms in shallow water bodies was developed and evaluated. This system was based on the known relationship between the concentration of the coliform bacteria and the amount of hydrogen they produce during growth in a complex organic media. The prototype system consists of a sampler platform, which sits on the bottom; a surface buoy, which transmits sampler-generated data; and a shore station, which receives, displays the data, and controls the sampler. The concept of remote monitoring of fecal coliform concentrations by utilizing a system based on the electrochemical method was verified during the evaluation of the prototype.

Grana, D. C.↗

Volcanic impact on stratospheric aerosol chemistry

Samples collected by the National Center for Atmospheric Research (NCAR) using the multiple-filter sampler on the U-2 were analyzed. The sampler is capable of exposing a number of 110 mm filters in sequence to ram air flow. Two types of filters, IPC cellulose and polystrene, were used, both of which have high blank levels for the trace elements determined. The levels of most trace elements in the stratosphere are so low under normal circumstances that none can be seen. Results from the eruption of Mt. St. Helens, a mystery cloud (probably volcanic in origin) in 1982, and the El Chichonal eruption in 1983 are discussed. To improve the collection of particles for chemical analysis, a new sampling system was developed for use on the U-2. The sampler consisted of an electrostatic collection of particles between 1 and 0.001 micron diameter dierectly onto electron microscopic grids, followed by a thermal precipitation for the smaller particles. The system was built and tested in the laboratory, but never flown on the U-2.

Zoller, W. H.↗

How successful were the lunar sampling tools: Implications for sampling Mars

Like the Mars Sample Return endeavor, the Apollo lunar-sample program began with definition of strategy for sample collection and of scientific requirements for sampling hardware design. Several lessons can be illustrated by specific tools. The evolution of drive tubes from narrow 2 cm diameter, thick-walled tubes (used on Apollo 11, 12 and 14) to 4 cm diameter, thin-walled tubes used on Apollo 15, 16, and 17) as an example of the improvements made possible during multiple missions. The original Apollo 11 drive tube was designed to work in fluffy soil; thus, only 50 percent of the relatively dense lunar soil was recovered, and the core was distorted. The final configuration resulted in nearly 100 pct recovery with little distortion. The surface samplers (Contact Soil Sampling Devices) were designed to collect the upper 100 micrometer or the upper 1 mm of soil. It was over 2 years after the mission before these particularly specific samplers were opened because interest in them waned. Both core tubes and surface samplers were difficult to open in the laboratory. The Apollo Lunar Sample Return Containers (ALSRCs) were constructed with one indium and 2 Viton seals. They were closed on the lunar surface. Interior container pressures measured upon return to the laboratory indicate that these seals were not reliable in the lunar environment. Also, choice of indium as a sealing material interfered with siderophile analyses of samples.

Allton, J. H.↗

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

Integrated Modeling of Spacecraft Touch-and-Go Sampling

An integrated modeling tool has been developed to include multi-body dynamics, orbital dynamics, and touch-and-go dynamics for spacecraft covering three types of end-effectors: a sticky pad, a brush-wheel sampler, and a pellet gun. Several multi-body models of a free-flying spacecraft with a multi-link manipulator driving these end-effectors have been tested with typical contact conditions arising when the manipulator arm is to sample the surface of an asteroidal body. The test data have been infused directly into the dynamics formulation including such information as the mass collected as a function of end-effector longitudinal speed for the brush-wheel and sticky-pad samplers, and the mass collected as a function of projectile speed for the pellet gun sampler. These data represent the realistic behavior of the end effector while in contact with a surface, and represent a low-order model of more complex contact conditions that otherwise would have to be simulated. Numerical results demonstrate the adequacy of these multibody models for spacecraft and manipulator- arm control design. The work contributes to the development of a touch-and-go testbed for small body exploration, denoted as the GREX Testbed (GN&C for Rendezvous-based EXploration). The GREX testbed addresses the key issues involved in landing on an asteroidal body or comet; namely, a complex, low-gravity field; partially known terrain properties; possible comet outgassing; dust ejection; and navigating to a safe and scientifically desirable zone.

Quadrelli, Marco↗

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect both the crew and the vehicle environment. Additionally, understanding of the atmospheric microbial profiles will be essential toward Mars-forward planetary protection planning. Currently, onboard the International Space Station (ISS), the air is monitored on a quarterly basis using an impaction air sampler. With this method, bacterial and fungal cells and spores are pulled onto plates containing growth medium. Following five days of ambient incubation onboard the ISS, the crew compares the growth to density charts and provides the approximations to the ground. Upon return of the culture plates to the Johnson Space Center’s Microbiology Laboratory, the isolates present are identified for crew health risk assessments. As NASA moves beyond the low-Earth orbit of ISS, sample return will be impractical. As such, a near real-time monitoring capability for the assessment of the spacecraft atmosphere is necessary. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is not dependent on microbial culture, thus removing the associated risk to the crew from high microbial levels, the bias toward detecting only the culturable organisms, and eliminates the need for sample return. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing and nanopore sequencing. The three samplers were compared in terms of mass and power requirements, ease-of -use, and the resulting data. For the two highest ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that could not be identified through the culture-based method. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon J Dunbar↗

Culture-Independent Microbial Air Profiling using a Spaceflight-Compatible Nanopore Sequencing Method

Microbial monitoring of spacecraft air is critical toward assessing the efficacy of microbial controls within the environmental control and life support systems to protect the crew and vehicle environment. Currently, onboard the International Space Station (ISS), the air is monitored every quarter using an impaction air sampler. With this method, microbial cells and spores are pulled onto plates containing a growth medium. Following onboard incubation, the crew reports approximate microbial levels to the ground, but sample return is required for identification. Upon return of the plates, the isolates present are identified for crew health risk assessments. As NASA moves beyond low-Earth orbit, sample return will be impractical, and a near real-time monitoring capability is essential. Significant strides have been made in recent years to utilize a molecular-based method for microbial profiling of ISS surfaces. The developed method is independent of microbial culture, thus removing the bias toward detecting only culturable organisms, eliminating the need for sample return, and reducing the risk to crew health from exposure to high microbial levels. The work described here details the evaluation of three different air sampling platforms whose product is amenable to downstream molecular processing. The three samplers were compared in terms of mass and power requirements, ease of use, and the resulting data. For the two highest-ranking samplers, a basic concept of operations was developed to transfer the sample into the already established preparation and sequencing process. Using these concepts of operations, an in-depth comparison of the molecular data generated was compared to the historical culture-based method. Data from both methods detailed similar microbial profiles, while the molecular method detailed microbial identifications that were lacking from the culture data. The developed method will enable the generation of near real-time microbial profiles of the spacecraft atmosphere.

Brandon Dunbar↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

NASA's Aerosol Sampling Experiment Summary

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Sampling Indoor Aerosols on the International Space Station

In a spacecraft cabin environment, the size range of indoor aerosols is much larger and they persist longer than on Earth because they are not removed by gravitational settling. A previous aerosol experiment in 1991 documented that over 90 of the mass concentration of particles in the NASA Space Shuttle air were between 10 m and 100 m based on measurements with a multi-stage virtual impactor and a nephelometer (Liu et al. 1991). While the now-retired Space Shuttle had short duration missions (less than two weeks), the International Space Station (ISS) has been continually inhabited by astronauts for over a decade. High concentrations of inhalable particles on ISS are potentially responsible for crew complaints of respiratory and eye irritation and comments about 'dusty' air. Air filtration is the current control strategy for airborne particles on the ISS, and filtration modeling, performed for engineering and design validation of the air revitalization system in ISS, predicted that PM requirements would be met. However, aerosol monitoring has never been performed on the ISS to verify PM levels. A flight experiment is in preparation which will provide data on particulate matter in ISS ambient air. Particles will be collected with a thermophoretic sampler as well as with passive samplers which will extend the particle size range of sampling. Samples will be returned to Earth for chemical and microscopic analyses, providing the first aerosol data for ISS ambient air.

Thermophoretic sampler↗

Dynamics of plankton populations in upwelling areas

There are no author-identified significant results in this report. Repeated coverage over the test site along the northwest coast of Africa showed that the structure of chlorophyll distribution is much more complicated than expected from continuous recordings. ERTS-1 data showed a very fast change in the chlorophyll distribution and it seems that also the concentration changes quickly. ERTS-1 showed on some frames offshore transportation of dust from the Sahara. All frames from Channel 7 will be arranged as a montage to derive the transportation pattern of dust. This step is important in biological aspects of interpreting ERTS-1 data, because the dissolution kinetics of eolian dust particles may influence significantly the chemistry of the surface water. Since visibility and the biochemistry of the test site off Africa are influenced by the dust transport, dust collection will be included in the ground truth program. Besides chlorophyll and other hydrographical parameters, the dust load in the test area will be measured. The collection plan is discussed along with a description of the high volume air sampler and the Anderson particle sizing head sampler to be used for the dust measurements.

Szekielda, K.↗

Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

Neustadter, H. E.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗