Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rooftop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Installing Hotel Rooftop Solar Array

This case study describes how a luxury hotel, Bardessono, utilized a major roof-top solar array in its design to achieve significant energy savings and LEED Platinum certification.

LEED, LEED Platinum, rooftop array, solar, solar p↗

Evaluation of flammable volume in the case of a catastrophic leak of R-32 from a rooftop unit

With the effort to use alternative refrigerants with lower global warming potential (GWP), the majority of these alternative refrigerants are classified as slightly flammable. Here in this paper we report on the numerical evaluation of a catastrophic leak scenario of R-32 refrigerant from a 3-ton roof top air conditioning unit (RTU) which serves a 12.2 × 9.14 × 2.4 m room. A full rupture of a 6.35 mm (¼ inch) pipe downstream of the evaporator coil is simulated. Two separate cases with refrigerant releases of 1.81 kg and 3.62 kg charge have been studied. The two charges are released in 10.2 and 20.4 s, respectively, just after the end of a unit cooling cycle. The flammable volume inside the room existed only for about 40 s with a maximum flammable volume inside the room of 1.12% of the total room volume for the 3.62 kg charge case.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CROCUS Weather Data at Northwestern University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). Vaisala WXT sensor is an all-in-one weather instrument that provides 6 of the most important weather parameters: barometric pressure, temperature, relative humidity, rainfall, wind speed and direction. Temperature, pressure, relative humidity, and rainfall are sampled at 1 second frequency, while wind speed/direction is measured at ten per second (10Hz) frequency. These measurements are useful for looking at characterizing local weather, identifying unique weather events, and studying local turbulence, especially given the high temporal resolution of the wind measurements. Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

EARTH SCIENCE > ATMOSPHERE > ATMOSPHERIC TEMPERATU↗

Energy Implications of Retrofitting Retail Sector Rooftop Units With Stepped Speed and Variable-Speed Functionality

Commercial retailers understand that retrofitting constant-speed RTU fan motors with stepped- or variable-speed alternatives could save significant energy in most U.S. climate zones. However, they lack supporting data, both real-world and simulation based, on the cost effectiveness and climate zone-specific energy savings associated with this measure. Thus, building managers and engineers havebeen unable to present a compelling business case for fan motor upgrades to upper management. This study uses whole-building energy simulation to estimate the energy impact of this type of measure so retailers can determine its economic feasibility.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Business Case for Proactive Rooftop Unit (RTU) Replacement

This document introduces the key elements to consider in making the business case for a proactive high-efficiency RTU replacement strategy for facility maintenance staff and building engineers responsible for energy management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Photovoltaics and Electric Vehicle Co-Adoption: Attitudes, Norms, Diffusion, and Economics

The overall objectives of the project were to (1) Identify personal and social norms, peer effects, demographics and contextual factors (such as household energy expenditures, experience with outages, charging infrastructure availability) that may facilitate or hinder Solar-EV co-adoption; (2) outline strategies for the design of programs and practices that will enable reasoned RPV and EV adoption and their co-adoption; and (3) assemble a dataset comprised of survey responses of RPV-EV co-adopters, RPV-only adopters, EV-only adopters, and non-adopters. These objectives were only partially fulfilled given the decision to terminate the project. The research team was able to complete the semi-structured interviews, the core BY1 task and summarize the results below. As well, once the team learned of the research project’s fate, it sought and obtained the DOE SETO Technical Manager’s approval to repurpose funds for BY2 tasks to the extent feasible. Rather than invest further resources in expanding the pool of potential survey respondents and having no budget to survey, the research team repurposed funds subject and undertook a more limited (geographically) survey, but also expanded to it to include contingent valuation questions. The analysis of the survey data will necessarily be delayed given the lack of budget support, although some information on the respondent sample is in the results. Given a lack of attention to co-adoption previously, the insights generated in this project should assist decision-makers and industry actors in the development of programs and practices that enable reasoned RPV adoption and EV adoption and their co-adoption.

14 SOLAR ENERGY↗

ComStock Measure Scenario Documentation: Standard Performance Heat Pump Rooftop Unit With New Windows

Building on a 3-year effort to calibrate and validate the U.S. Department of Energy's ResStock (TM) and ComStock (TM) models, this work produces national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual energy consumption (at subhourly resolution) of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. The goal of this work is to develop energy efficiency and demand flexibility end-use load shapes that cover high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to various "what-if" scenarios that can be applied to buildings. An end-use savings shape is the difference in energy consumption between a baseline building (or collection of buildings) and a building with an energy efficiency or demand flexibility measure applied. It results in a time-series profile broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step, as well as annual aggregations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rooftop Unit Replacement: adidas RTU Planned Replacement Program

This case study describes adidas’ successful implementation of a planned RTU replacement program designed to standardize equipment features and reduce costs, enabling the company to streamline acquisitions and ensure each location had the required equipment.

rooftop unit, RTU, replacement, retail, HVAC, air ↗

Innovative Approach to Rooftop Unit Replacement for Schools: Advanced RTU Campaign

This case study describes Fontana Unified School District’s use of Proposition 39 grant money to install 201 high-efficiency RTUs in 30 buildings across four schools in California. The work resulted in $214,000 saved per year and was the first phase of a three-part project that includes updated controls, LED lighting and lighting control systems, and an additional 150-190 high-efficiency RTUs.

rooftop unit, RTU, LED, lighting, controls, public↗

Degradation of Edge-Defined Film-Fed Silicon Glass–Glass Modules on Florida Rooftop After 22 Years

Thin silicon (< 100 μm) adoption can provide significantly lower cost. Kerfless technologies provide thin wafers while preventing material from being wasted. Understanding how this family of processing influences module reliability is important. A set of four edge-defined film-fed growth (EFG) silicon modules from a ten-module system in Florida is measured after 22 years of exposure. Power loss rates of 0.58–0.78% year -1 are measured for three modules, while a rate of 1.32% is measured for a module with severe delamination and corrosion. Short-circuit current degrades between 10.7% and 13.1% for all modules. Further, the losses are primarily optical and recombination based; however, series and shunt resistance effects play a non-negligible role. Pre-existing recombination losses exist but are exacerbated via degradation. Optical losses in short-circuit current are due in part to encapsulant yellowing. Electroluminescence (EL) images display the effects of processing on bulk quality by clearly showing lines of alternating brightness along the wafer length. To the authors’ knowledge, this is the first article displaying suns–V OC data, effective lifetime versus excess carrier density data, and module EL images for EFG silicon-based modules.

36 MATERIALS SCIENCE↗