At least 145 records · Page 8

Distribution and Room Air Mixing Risks to Retrofitted Homes

An energy efficiency upgrade reduces a home’s heating and cooling load. If the load reduction is great enough and the heating, ventilation, and air conditioning system warrants replacement, that system is often upgraded with a more efficient, lower capacity system that meets the load of the upgraded house. For a single-story house with floor supply air diffusers, the ducts often are removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling. In this project, IBACOS performed load calculations for a two-story 1960s house and characterized duct sizes and layouts based on industry “rules of thumb” (Herk et al. 2014). The team performed duct-sizing calculations for unaltered ducts and post-retrofit airflows and examined airflow velocities and pressure changes with respect to various factors. The team then used a mocked-up duct and register setup to measure the characteristics of isothermal air—to reduce the effects of buoyancy from the observations—passing through the duct and leaving the register.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neurovascular bundle–sparing radiotherapy for prostate cancer using MRI-CT registration: A dosimetric feasibility study

Purpose: Sexual dysfunction after radiotherapy for prostate cancer remains an important late adverse toxicity. The neurovascular bundles (NVB) that lie posterolaterally to the prostate are typically spared during prostatectomy, but in traditional radiotherapy planning they are not contoured as an organ-at-risk with dose constraints. Our goal was to determine the dosimetric feasibility of “NVB-sparing” prostate radiotherapy while still delivering adequate dose to the prostate. Methods: Twenty-five consecutive patients with prostate cancer (with no extraprostatic disease on pelvic magnetic resonance imaging [MRI]) who that were treated with external beam radiotherapy, with the same primary planning target volume margins, to a dose of 79.2 Gy were evaluated. Pelvic MRI and simulation computed tomography scans were registered using dedicated software to allow for bilateral NVB target delineation on T2-weighted MRI. A volumetric modulated arc therapy plan was generated using the NVB bilaterally with 2 mm margin as an organ to spare and compared to the patient’s previously delivered plan. Dose-volume histogram endpoints for NVB, rectum, bladder, and planning target volume 79.2 were compared between the 2 plans using a 2-tailed paired t-test. Results: The V70 for the NVB was significantly lower on the NVB-sparing plan (p <0.01), while rectum and bladder endpoints were similar. Target V100% was similar but V{sub 105%} was higher for the NVB-sparing plans (p <0.01). Conclusions: “NVB-sparing” radiotherapy is dosimetrically feasible using CT-MRI registration, and for volumetric modulated arc therapy technology — target coverage is acceptable without increased dose to other normal structures, but with higher target dose inhomogeneity. The clinical impact of “NVB-sparing” radiotherapy is currently under study at our institution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a cable-free system based on p-type MOSFET detectors for 'in vivo' entrance skin dose measurements in interventional radiology

Purpose: During radiological interventional procedures (RIP) the skin of a patient under examination may undergo a prolonged x-ray exposure, receiving a dose as high as 5 Gy in a single session. This paper describes the use of the OneDose{sup TM} cable-free system based on p-type MOSFET detectors to determine the entrance skin dose (ESD) at selected points during RIP. Methods: At first, some dosimetric characteristics of the detector, such as reproducibility, linearity, and fading, have been investigated using a C-arc as a source of radiation. The reference setting (RS) was: 80 kV energy, 40 cm Multiplication-Sign 40 cm field of view (FOV), current-time product of 50 mAs and source to skin distance (SSD) of 50 cm. A calibrated PMX III solid state detector was used as the reference detector and Gafchromic{sup Registered-Sign} films have been used as an independent dosimetric system to test the entire procedure. A calibration factor for the RS and correction factors as functions of tube voltage and FOV size have been determined. Results: Reproducibility ranged from 4% at low doses (around 10 cGy as measured by the reference detector) to about 1% for high doses (around 2 Gy). The system response was found to be linear with respect to both dose measured with the PMX III and tube voltage. The fading test has shown that the maximum deviation from the optimal reading conditions (3 min after a single irradiation) was 9.1% corresponding to four irradiations in one hour read 3 min after the last exposure. The calibration factor in the RS has shown that the system response at the kV energy range is about four times larger than in the MV energy range. A fifth order and fourth order polynomial functions were found to provide correction factors for tube voltage and FOV size, respectively, in measurement settings different than the RS. ESDs measured with the system after applying the proper correction factors agreed within one standard deviation (SD) with the corresponding ESDs measured with the reference detector. The ESDs measured with Gafchromic{sup Registered-Sign} films were in agreement within one SD compared to the ESDs measured using the OneDose{sup TM} system, as well. The global uncertainty associated to the OneDose{sup TM} system established in our experiments, ranged from 7% to 10%, depending on the duration of the RIP due to fading. These values are much lower than the uncertainty commonly accepted for general diagnostic practices (20%) and of about the same size of the uncertainty recommended for practices with high risk of deterministic side effects (7%). Conclusions: The OneDose{sup TM} system has shown a high sensitivity in the kV energy range and has been found capable of measuring the entrance skin dose in RIP.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Residual Setup Errors of Different IGRT Alignment Procedures for Head and Neck IMRT and the Resulting Dosimetric Impact

Purpose: To assess residual setup errors during head and neck radiation therapy and the resulting consequences for the delivered dose for various patient alignment procedures. Methods and Materials: Megavoltage cone beam computed tomography (MVCBCT) scans from 11 head and neck patients who underwent intensity modulated radiation therapy were used to assess setup errors. Each MVCBCT scan was registered to its reference planning kVCT, with seven different alignment procedures: automatic alignment and manual registration to 6 separate bony landmarks (sphenoid, left/right maxillary sinuses, mandible, cervical 1 [C1]-C2, and C7-thoracic 1 [T1] vertebrae). Shifts in the different alignments were compared with each other to determine whether there were any statistically significant differences. Then, the dose distribution was recalculated on 3 MVCBCT images per patient for every alignment procedure. The resulting dose-volume histograms for targets and organs at risk (OARs) were compared to those from the planning kVCTs. Results: The registration procedures produced statistically significant global differences in patient alignment and actual dose distribution, calling for a need for standardization of patient positioning. Vertically, the automatic, sphenoid, and maxillary sinuses alignments mainly generated posterior shifts and resulted in mean increases in maximal dose to OARs of >3% of the planned dose. The suggested choice of C1-C2 as a reference landmark appears valid, combining both OAR sparing and target coverage. Assuming this choice, relevant margins to apply around volumes of interest at the time of planning to take into account for the relative mobility of other regions are discussed. Conclusions: Use of different alignment procedures for treating head and neck patients produced variations in patient setup and dose distribution. With concern for standardizing practice, C1-C2 reference alignment with relevant margins around planning volumes seems to be a valid option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nissin Ion Doping System--H{sub 2}{sup +} Implantation for Silicon Layer Exfoliation

A Nissin iG4 ion doping system (termed iG4) utilizes broad beam technology to implant GEN 4 sheets of glass for LCD production. The mechanical scanned end-station with robotic handling for GEN 4 glass substrates was redesigned, and a new end-station was built to handle rectangular silicon tiles (23x18 cm). A three sub-system modular risk reduction process was used to test production solutions, and maximize the success of transferring the R and D implant recipes developed on a standard focused beam ion implanter to the Nissin broad beam iG4 solution. The silicon tile end-station including the implant scanning system was tested for reliability and durability. The end-station handled rectangular silicon tiles reliably without detrimental edge chipping or silicon breakage. The ion optics was demonstrated to successfully provide stable hydrogen ions for the Corning registered silicon on glass layer transfer process. This layer transfer process is very susceptible and sensitive to the implant processing temperature. The temperature excursions during implant processing for the iG4 exfoliation process were found to be in line with the R and D focused ion beam system. This data confirmed the system production-readiness in providing an efficient solution for the high volume production of hydrogen implanted silicon rectangular tiles.

36 MATERIALS SCIENCE↗

SU-E-J-89: Motion Effects On Organ Dose in Respiratory Gated Stereotactic Body Radiation Therapy

Purpose: Existing reports on gated radiation therapy focus mainly on optimizing dose delivery to the target structure. This work investigates the motion effects on radiation dose delivered to organs at risk (OAR) in respiratory gated stereotactic body radiation therapy (SBRT). A new algorithmic tool of dose analysis is developed to evaluate the optimality of gating phase for dose sparing on OARs while ensuring adequate target coverage. Methods: Eight patients with pancreatic cancer were treated on a phase I prospective study employing 4DCT-based SBRT. For each patient, 4DCT scans are acquired and sorted into 10 respiratory phases (inhale-exhale- inhale). Treatment planning is performed on the average CT image. The average CT is spatially registered to other phases. The resultant displacement field is then applied on the plan dose map to estimate the actual dose map for each phase. Dose values of each voxel are fitted to a sinusoidal function. Fitting parameters of dose variation, mean delivered dose and optimal gating phase for each voxel over respiration cycle are mapped on the dose volume. Results: The sinusoidal function accurately models the dose change during respiratory motion (mean fitting error 4.6%). In the eight patients, mean dose variation is 3.3 Gy on OARs with maximum of 13.7 Gy. Two patients have about 100cm{sup 3} volumes covered by more than 5 Gy deviation. The mean delivered dose maps are similar to plan dose with slight deformation. The optimal gating phase highly varies across the patient, with phase 5 or 6 on about 60% of the volume, and phase 0 on most of the rest. Conclusion: A new algorithmic tool is developed to conveniently quantify dose deviation on OARs from plan dose during the respiratory cycle. The proposed software facilitates the treatment planning process by providing the optimal respiratory gating phase for dose sparing on each OAR.

60 APPLIED LIFE SCIENCES↗

A Cultural Resources Inventory and Historical Evaluation of the Shasta Atmospheric Test, Areas 2, 4, and 8, Nevada National Security Site, Nye County, Nevada

This report presents the results of a National Historic Preservation Act Section 106 cultural resources inventory and historical evaluation of the 1957 Shasta atmospheric test area located on the Nevada National Security Site. The Desert Research Institute was tasked to conduct a cultural resources inventory of the Shasta test close-in ground zero area as a result of a proposed undertaking by the U.S. Department of Energy Environmental Management. This undertaking involves investigation of Corrective Action Site (CAS) 02-23-05 for potential contaminants of concern as delineated in the Corrective Action Investigation Plan. Based on the investigation, contaminants exceeding risk-based levels would be the subject of corrective actions. The CAS 02-23-05 area coincides with a historic resource and corrective actions would potentially have an adverse effect on a historic property.

1957↗

Salvage High-intensity Focused Ultrasound for the Recurrent Prostate Cancer after Radiotherapy

To investigate the use of minimally invasive high-intensity focused ultrasound (HIFU) as a salvage therapy in men with localized prostate cancer recurrence following external beam radiotherapy (EBRT), brachytherapy or proton therapy. A review of 20 cases treated using the Sonablate registered 500 HIFU device, between August 28, 2002 and September 1, 2009, was carried out. All men had presumed organ-confined, histologically confirmed recurrent prostate adenocarcinoma following radiation therapy. All men with presumed, organ-confined, recurrent disease following EBRT in 8 patients, brachytherapy in 7 patients or proton therapy in 5 patients treated with salvage HIFU were included. The patients were followed for a mean (range) of 16.0 (3-80) months. Biochemical disease-free survival (bDFS) rates in patients with low-intermediate and high risk groups were 86% and 50%, respectively. Side-effects included urethral stricture in 2 of the 16 patients (13%), urinary tract infection or dysuria syndrome in eight (26%), and urinary incontinence in one (6%). Recto-urethral fistula occurred in one patient (6%). Transrectal HIFU is an effective treatment for recurrence after radiotherapy especially in patients with low- and intermediate risk groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multibeam tomotherapy: A new treatment unit devised for multileaf collimation, intensity-modulated radiation therapy

A fully integrated system for treatment planning, application, and verification for automated multileaf collimator (MLC) based, intensity-modulated, image-guided, and adaptive radiation therapy (IMRT, IGRT and ART, respectively) is proposed. Patient comfort, which was the major development goal, will be achieved through a new unit design and short treatment times. Our device for photon beam therapy will consist of a new dual energy linac with five fixed treatment heads positioned evenly along one plane but one electron beam generator only. A minimum of moving parts increases technical reliability and reduces motion times to a minimum. Motion is allowed solely for the MLCs, the robotic patient table, and the small angle gantry rotation of {+-}36 deg. . Besides sophisticated electron beam guidance, this compact setup can be built using existing modules. The flattening-filter-free treatment heads are characterized by reduced beam-on time and contain apertures restricted in one dimension to the area of maximum primary fluence output. In the case of longer targets, this leads to a topographic intensity modulation, thanks to the combination of 'step and shoot' MLC delivery and discrete patient couch motion. Owing to the limited number of beam directions, this multislice cone beam serial tomotherapy is referred to as 'multibeam tomotherapy.' Every patient slice is irradiated by one treatment head at any given moment but for one subfield only. The electron beam is then guided to the next head ready for delivery, while the other heads are preparing their leaves for the next segment. The 'Multifocal MLC-positioning' algorithm was programmed to enable treatment planning and optimize treatment time. We developed an overlap strategy for the longitudinally adjacent fields of every beam direction, in doing so minimizing the field match problem and the effects of possible table step errors. Clinical case studies show for the same or better planning target volume coverage, better organ-at-risk sparing, and comparable mean integral dose to the normal tissue a reduction in treatment time by more than 50% to only a few minutes in comparison to high-quality 3-D conformal and IMRT treatments. As a result, it will be possible to incorporate features for better patient positioning and image guidance, while sustaining reasonable overall treatment times at the same time. The virtual multibeam tomotherapy design study TOM'5-CT contains a dedicated electron beam CT (TOM'AGE) and an objective optical topometric patient positioning system (TOPOS registered ). Thanks to the wide gantry bore of 120 cm and slim gantry depths of 70 cm, patients can be treated very comfortably, in all cases tumor-isocentrically, as well as with noncoplanar beam arrangements as in stereotactic radiosurgery with a couch rotation of up to {+-}54 deg. . The TOM'5 treatment unit on which this theoretical concept is based has a stand-alone depth of 40 cm and an outer diameter of 245 cm; the focus-isocenter distance of the heads is 100 cm with a field size of 40 cmx7 cm and 0.5 cm leaves, which operate perpendicular to the axis of table motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Issues in UK cleanup and decommissioning; a strategic R and D programme

Nexia Solutions is contracted to manage and carry out research on behalf of the Nuclear Decommissioning Authority (NDA). This paper will describe the nuclear research ongoing and how it fits in with the UK cleanup and decommissioning strategy. The aim of the strategic R and D programme is to assist the NDA in maintaining a technical portfolio which will:- - identify and address challenges and clean-up problems that do not have an existing solution; - resolve potential inconsistencies between sites in the technical bases for certain strategic decisions and their implementation; - maintain options while developing strategy (emerging risks); - save costs by developing multi-site solutions; - provide technology, skills and facilities on the timescale required. The strategy for the R and D programme has been developed from a top-level approach by understanding the challenges which need to be addressed and prioritising these according to the objectives of the programme. The programme has demonstrated that a technical portfolio comprising six areas, each containing a number of key themes, is appropriate to address the technical challenges which the NDA faces and aligns with the NDA's technical issues register. An important aspect of the R and D programme is that it should create opportunities for undertaking the NDA mission more effectively. This arises from the emphasis given in those technical programmes which define the challenge more precisely and thus provide a platform from which to produce innovative solutions. The paper will present an overview of the strategic R and D programme along with the key technical programme areas. Examples will be provided of the technical work ongoing, and the results obtained so far. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Adenosine stress myocardial perfusion imaging in octogenarians: Safety, tolerability, and long-term prognostic implications of hemodynamic response and SPECT-related variables

Background: Evaluation of tolerability, safety, and prognostic implications of adenosine stress myocardial perfusion imaging (MPI) in octogenarians. Methods: 370 octogenarians (49% known coronary artery disease) were studied. Hemodynamic response, MPI-related data, and rest-left ventricular ejection fraction (LVEF) based on echocardiography were registered per patient, and prospective follow-up was performed to document all-cause death (ACD), cardiac death (CD), myocardial infarction (MI), and late revascularization. Results: No deaths or MIs were observed during adenosine infusion or the short-term post-infusion period. 86% of patients were able to tolerate a 6-minute infusion. All side effects terminated spontaneously after infusion cessation, except for one case of pulmonary oedema. After 9.3 years, there were 124 ACDs, 62 CDs, 16 MIs, and 35 revascularizations. Differences between survival curves of summed stress score (SSS)-based risk groups were significant for all end points (P < .001). SSS and LVEF were independent predictors of all end points (P ≤ .01) and lung uptake of cardiac end points. ΔHR <10 bpm (OR = 1.78, P = .004) and inability to increase HR by >10 bpm and decrease systolic blood pressure by >10 mmHg (OR = 2, P = .02) during adenosine infusion were independent predictors of ACD and CD, respectively. Hemodynamic response variables, SSS, and lung uptake provided incremental prognostic value over pre-test data for ACD and CD. Conclusions: In octogenarians, adenosine stress MPI is well tolerated and provides effective long-term risk stratification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of photon irradiation treatment upon calcium content of ribs of Wistar rats using micro-XRF

Therapeutic doses of radiation have been shown to have deleterious consequences on bone health. Among the treatment strategies used for breast cancer treatment, the most used are radiotherapy and chemotherapy. Radiotherapy may be given to destroy the cancer cells using high-dose x-rays. Protocols vary considerably, but generally whole body irradiation totals from 10 to 15 Gy, whereas local therapy totals from 40 to 70 Gy. In clinical practice, the quantitative evaluation of bone tissue relies on measurements of bone mineral density values, which are closely associated with the risk of osteoporotic fracture. Improved survivorship rates of cancer patients receiving radiotherapy increase the importance of understanding the mechanisms and long-term effects of radiation-induced bone loss. In this work, we investigated the variation on calcium distribution in ribs of female Wistar rats (Rattus norvegicus) submitted to photon irradiation with a single dose of 20 Gy. The determination of the calcium distribution was performed using synchrotron radiation microfluorescence (SR-{mu}XRF) at the X-ray Fluorescence beamline at Brazilian Synchrotron Light Laboratory (LNLS). Animals were irradiated using the linear accelerator Varian registered (CLINAC 2100) at the University Centre for Cancer Control of the State University of Rio de Janeiro (CUCC/UERJ). The total dose delivered was 20 Gy. The animals were about three months old and weighting about 200g. They were distributed into two groups (seven per group): control (did not receive any treatment) and irradiated (submitted to irradiation procedure) groups. Results showed that calcium content decreased within the dorsal ribs of rats submitted to radiotherapy in comparison to the control group.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Radiation-Induced Normal Lung Tissue Density Changes for Patients From Multiple Institutions Receiving Conventional or Hypofractionated Treatments

Purpose: To quantitatively assess changes in computed tomography (CT)–defined normal lung tissue density after conventional and hypofractionated radiation therapy (RT). Methods and Materials: The pre-RT and post-RT CT scans from 118 and 111 patients receiving conventional and hypofractionated RT, respectively, at 3 institutions were registered to each other and to the 3-dimensional dose distribution to quantify dose-dependent changes in normal lung tissue density. Dose-response curves (DRC) for groups of patients receiving conventional and hypofractionated RT were generated for each institution, and the frequency of density changes >80 Hounsfield Units (HU) was modeled depending on the fractionation type using a Probit model for different follow-up times. Results: For the pooled data from all institutions, there were significant differences in the DRC between the conventional and hypofractionated groups; the respective doses resulting in 50% complication risk (TD{sub 50}) were 62 Gy (95% confidence interval [CI] 57-67) versus 36 Gy (CI 33-39) at <6 months, 48 Gy (CI 46-51) versus 31 Gy (CI 28-33) at 6-12 months, and 47 Gy (CI 45-49) versus 35 Gy (32-37) at >12 months. The corresponding m values (slope of the DRC) were 0.52 (CI 0.46-0.59) versus 0.31 (CI 0.28-0.34) at <6 months, 0.46 (CI 0.42-0.51) versus 0.30 (CI 0.26-0.34) at 6-12 months, and 0.45 (CI 0.42-0.50) versus 0.31 (CI 0.27-0.35) at >12 months (P<.05 for all comparisons). Conclusion: Compared with conventional fractionation, hypofractionation has a lower TD{sub 50} and m value, both suggesting an increased degree of normal tissue density sensitivity with hypofractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of real-time radiation dosimetry using a new silicon LET sensor

A new type of real-time radiation monitoring device, RRMD-III, consisting of three double-sided silicon strip detectors (DSSDs), has been developed and tested on-board the Space Shuttle mission STS-84. The test succeeded in measuring the linear energy transfer (LET) distribution over the range of 0.2 keV/micrometer to 600 keV/micrometer for 178 h. The Shuttle cruised at an altitude of 300 to 400 km and an inclination angle of 51.6 degrees for 221.3 h, which is equivalent to the International Space Station orbit. The LET distribution obtained for particles was investigated by separating it into galactic cosmic ray (GCR) particles and trapped particles in the South Atlantic Anomaly (SAA) region. The result shows that the contribution in dose-equivalent due to GCR particles is almost equal to that from trapped particles. The total absorbed dose rate during the mission was 0.611 mGy/day; the effective quality factor, 1.64; and the dose equivalent rate, 0.998 mSv/day. The average absorbed dose rates are 0.158 mGy/min for GCR particles and 3.67 mGy/min for trapped particles. The effective quality factors are 2.48 for GCR particles and 1.19 for trapped particles. The absorbed doses obtained by the RRMD-III and a conventional method using TLD (Mg(2)SiO(4)), which was placed around the RRMD-III were compared. It was found that the TLDs showed a lower efficiency, just 58% of absorbed dose registered by the RRMD-III.

NASA Discipline Radiation Health↗

SU-F-J-223: Patterns of Failure for Laryngeal Cancer Patients Treated with Definitive IMRT: Comparing Two Different Methods for Determining the Origin of Recurrence From Follow-Up PET/CT Scans

Purpose: To determine patterns of failure in laryngeal cancer treated with definitive IMRT by comparing two different methods for identifying the recurrence epicenter on follow-up PET/CT. Methods: We identified 20 patients treated for laryngeal squamous cell carcinoma with definitive IMRT who had loco-regional recurrence diagnosed on PET/CT. Recurrence PET/CT scans were co-registered with the original treatment planning CT using deformable image registration with the VoxAlign deformation engine in MIM Software. Recurrence volumes were delineated on co-registered follow-up scans using a semi-automatic PETedge tool and two separate methods were used to identify the recurrence point of origin: a) Finding the point within the recurrence volume for which the maximum distance to the surface of the surrounding recurrence volume is smaller than for any other point. b) Finding the point within the recurrence volume with the maximum standardized uptake value (SUVmax), without geometric restrictions.For each method the failure pattern was determined as whether the recurrence origin fell within the original high-dose target volumes GTV70, CTV70, PTV70 (receiving 70Gy), intermediate-risk PTV59 (receiving 59.4Gy) or low-risk PTV54 (receiving 54.1Gy), in the original treatment planning CT. Results: 23 primary/nodal recurrences from the 20 patients were analyzed. The three-dimensional distance between the two different origins was on average 10.5mm (std.dev. 10mm). Most recurrences originated in the high-dose target volumes for both methods with 13 (57%) and 11 (48%) in the GTV70 and 20 (87%) and 20 (87%) in the PTV70 for method a) and b), respectively. There was good agreement between the two methods in classifying the origin target volumes with 69% concordance for GTV70, 89% for CTV70 and 100% for PTV70. Conclusion: With strong agreement in patterns of failure between two separate methods for determining recurrence origin, we conclude that most recurrences occurred within the high-dose treatment region, which influences potential risk-adaptive treatment strategies.

60 APPLIED LIFE SCIENCES↗

Robust Proton Pencil Beam Scanning Treatment Planning for Rectal Cancer Radiation Therapy

Purpose: To investigate, in a treatment plan design and robustness study, whether proton pencil beam scanning (PBS) has the potential to offer advantages, relative to interfraction uncertainties, over photon volumetric modulated arc therapy (VMAT) in a locally advanced rectal cancer patient population. Methods and Materials: Ten patients received a planning CT scan, followed by an average of 4 weekly offline CT verification CT scans, which were rigidly co-registered to the planning CT. Clinical PBS plans were generated on the planning CT, using a single-field uniform-dose technique with single-posterior and parallel-opposed (LAT) fields geometries. The VMAT plans were generated on the planning CT using 2 6-MV, 220° coplanar arcs. Clinical plans were forward-calculated on verification CTs to assess robustness relative to anatomic changes. Setup errors were assessed by forward-calculating clinical plans with a ±5-mm (left–right, anterior–posterior, superior–inferior) isocenter shift on the planning CT. Differences in clinical target volume and organ at risk dose–volume histogram (DHV) indicators between plans were tested for significance using an appropriate Wilcoxon test (P<.05). Results: Dosimetrically, PBS plans were statistically different from VMAT plans, showing greater organ at risk sparing. However, the bladder was statistically identical among LAT and VMAT plans. The clinical target volume coverage was statistically identical among all plans. The robustness test found that all DVH indicators for PBS and VMAT plans were robust, except the LAT's genitalia (V5, V35). The verification CT plans showed that all DVH indicators were robust. Conclusions: Pencil beam scanning plans were found to be as robust as VMAT plans relative to interfractional changes during treatment when posterior beam angles and appropriate range margins are used. Pencil beam scanning dosimetric gains in the bowel (V15, V20) over VMAT suggest that using PBS to treat rectal cancer may reduce radiation treatment–related toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-132: Automated Segmentation with Post-Registration Atlas Selection Based On Mutual Information

Purpose: The delineation of targets and organs-at-risk is a critical step during image-guided radiation therapy, for which manual contouring is the gold standard. However, it is often time-consuming and may suffer from intra- and inter-rater variability. The purpose of this work is to investigate the automated segmentation. Methods: The automatic segmentation here is based on mutual information (MI), with the atlas from Public Domain Database for Computational Anatomy (PDDCA) with manually drawn contours.Using dice coefficient (DC) as the quantitative measure of segmentation accuracy, we perform leave-one-out cross-validations for all PDDCA images sequentially, during which other images are registered to each chosen image and DC is computed between registered contour and ground truth. Meanwhile, six strategies, including MI, are selected to measure the image similarity, with MI to be the best. Then given a target image to be segmented and an atlas, automatic segmentation consists of: (a) the affine registration step for image positioning; (b) the active demons registration method to register the atlas to the target image; (c) the computation of MI values between the deformed atlas and the target image; (d) the weighted image fusion of three deformed atlas images with highest MI values to form the segmented contour. Results: MI was found to be the best among six studied strategies in the sense that it had the highest positive correlation between similarity measure (e.g., MI values) and DC. For automated segmentation, the weighted image fusion of three deformed atlas images with highest MI values provided the highest DC among four proposed strategies. Conclusion: MI has the highest correlation with DC, and therefore is an appropriate choice for post-registration atlas selection in atlas-based segmentation. Xuhua Ren and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

60 APPLIED LIFE SCIENCES↗

High-Dose-Rate Brachytherapy and External-Beam Radiotherapy for Hormone-Naieve Low- and Intermediate-Risk Prostate Cancer: A 7-Year Experience

Purpose: To report clinical outcomes and early and late complications in 264 hormone-naieve patients with low- and intermediate-risk prostate cancer treated with high-dose-rate brachytherapy (HDR-BT) in combination with external-beam radiotherapy (EBRT). Methods and Materials: Between February 2000 and July 2007, 264 patients underwent HDR-BT in combination with EBRT as a treatment for their low- to intermediate-risk prostate cancer. The HDR-BT was performed using ultrasound-based implantation. The total HDR-BT dose was 18 Gy in 3 fractions within 24 h, with a 6-h minimum interval. The EBRT started 2 weeks after HDR-BT and was delivered in 25 fractions of 1.8 Gy to 45 Gy within 5 weeks. Results: After a mean follow-up of 74.5 months, 4 patients (1.5%) showed prostate-specific antigen progression according to the American Society for Radiation Oncology definition and 8 patients (3%) according to the Phoenix definition. A biopsy-proven local recurrence was registered in 1 patient (0.4%), and clinical progression (bone metastases) was documented in 2 patients (0.7%). Seven-year actuarial freedom from biochemical failure was 97%, and 7-year disease-specific survival and overall survival were 100% and 91%, respectively. Toxicities were comparable to other series. Conclusions: Treatment with interstitial HDR-BT plus EBRT shows a low incidence of late complications and a favorable oncologic outcome after 7 years follow-up.