Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Response Spectrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Aquifer Poroelastic Response to Impulse and Oscillatory Well Pressure Using Distributed Acoustic Sensing

Abstract The storage of fluids in the subsurface is critical for a broad spectrum of applications including managed aquifer recharge, storage of liquefied carbon dioxide and hydrogen, geothermal heat extraction and exploitation of hydrocarbon. It is surprising then, that there has been relatively little measurement of the vertical distribution of poroelastic storage in geologic formations as compared with permeability. We present experiments in which fluid was injected into an important regional aquifer and the depth‐dependent strain response measured using fiber optic distributed acoustic sensing. The formation expansion and contraction in response to fluid injection were several 100 nanostrain. Strain, and the implied storage distribution, was highly localized in specific strata and demonstrated complex, hydromechanical behavior. This new window into fluid‐geomechanical coupling undermines some typically use models and observations currently in practice, but provides potential for complete representation and prediction of fluid storage in the subsurface.

58 GEOSCIENCES↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PCP consensus protein/peptide alphavirus antigens stimulate broad spectrum neutralizing antibodies

Vaccines based on proteins and peptides may be safer and if calculated based on many sequences, more broad-spectrum than those designed based on single strains. Physicochemical Property Consensus (PCP con ) alphavirus (AV) antigens from the B-domain of the E2 envelope protein were designed, synthesized recombinantly and shown to be immunogenic (i.e. sera after inoculation detected the antigen in dotspots and ELISA). Antibodies in sera after inoculation with B-region antigens based on individual AV species (eastern or Venezuelan equine encephalitis (EEEV con , VEEV con ), or chikungunya (CHIKV con ) bound only their cognate protein, while those designed against multiple species (Mosaik con and EVC con ) recognized all three serotype specific antigens. The VEEV con and EEEV con sera only showed antiviral activity against their related strains (in plaque reduction neutralization assays (PRNT 50/80 ). Peptides designed to surface exposed areas of the E2-A-domain of CHIKV con were added to CHIKV con inocula to provide anti-CHIKV antibodies. EVC con , based on three different alphavirus species, combined with E2-A-domain peptides from AllAV con , a PCPcon of 24 diverse AV, generated broad spectrum, antiviral antibodies against VEEV, EEEV and CHIKV, AV with less than 35% amino acid identity to each other (>65% diversity). This is a promising start to a molecularly defined vaccine against all AV. A further study with these antigens can illuminate what areas are most important for a robust immune response, resistant to mutations in rapidly evolving viruses. The validated computational methods can also be used to design broad spectrum antigens against many other pathogen families.

59 BASIC BIOLOGICAL SCIENCES↗

Dispersive Charge Transfer State Electroluminescence in Organic Solar Cells

Abstract The notion of quasi‐equilibrium is central to most solar cells; however, it has been questioned in organic photovoltaics (OPVs) owing to strong energetic disorder that frustrates efficient relaxation of electrons and holes within their respective density of states (DOS). Here, modulation electroluminescence (EL) spectroscopy is applied to OPVs and it is found that the frequency response of charge transfer (CT) state EL on the high energy side of the spectrum differs from that of the low energy side. This observation confirms that static disorder contributes substantially to the linewidth of the steady‐state EL spectrum and is unambiguous proof that the distribution of CT states formed by electrical injection in the dark is not in quasi‐equilibrium. These results emphasize the need for caution when analyzing OPV cells on the basis of reciprocity models that assume quasi‐equilibrium holds, and highlight a new method to study this unusual aspect of OPV operation.

14 SOLAR ENERGY↗

Giant enhancement of nonreciprocity in gyrotropic heterostructures

Abstract Nonreciprocity is a highly desirable feature in photonic media since it allows for control over the traveling electromagnetic waves, in a way that goes far beyond ordinary filtering. One of the most conventional ways to achieve nonreciprocity is via employing gyrotropic materials; however, their time-reversal-symmetry-breaking effects are very weak and, hence, large, bulky setups combined with very strong magnetic biases are required for technologically useful devices. In this work, artificial heterostructures are introduced to enhance the effective nonreciprocal behavior by reducing the contribution of the diagonal susceptibilities in the collective response; in this way, the off-diagonal ones, that are responsible for nonreciprocity, seem bigger. In particular, alternating gyrotropic and metallic or plasmonic films make an epsilon-near-zero (ENZ) effective-medium by averaging the diagonal permittivities of opposite sign, representing the consecutive layers. The homogenization process leaves unaltered the nonzero off-diagonal permittivities of the original gyrotropic substance, which become dominant and ignite strong nonreciprocal response. Realistic material examples that could be implemented experimentally in the mid-infrared spectrum are provided while the robustness of the enhanced nonreciprocity in the presence of actual media losses is discussed and bandwidth limitations due to the unavoidable frequency dispersion are elaborated. The proposed concept can be extensively utilized in designing optical devices that serve a wide range of applications from signal isolation and wave circulation to unidirectional propagation and asymmetric power amplification.

42 ENGINEERING↗

The Electromagnetic Characteristics of the Tianlai Cylindrical Pathfinder Array

A great challenge for 21 cm intensity mapping experiments is the strong foreground radiation which is orders of magnitude brighter than the 21 cm signal. Removal of the foreground takes advantage of the fact that its frequency spectrum is smooth while the redshifted 21 cm signal spectrum is stochastic. However, a complication is the non-smoothness of the instrument response. This paper describes the electromagnetic simulation of the Tianlai cylinder array, a pathfinder for 21 cm intensity mapping experiments. Due to the vast scales involved, a direct simulation requires a large amount of computing resources. We have made the simulation practical by using a combination of methods: first simulate a single feed, then an array of feed units, finally with the feed array and a cylindrical reflector together, obtain the response for a single cylinder. We studied its radiation pattern, bandpass response and the effects of mutual coupling between feed units, and compared the results with observation. Many features seen in the measurement result are reproduced well in the simulation, especially the oscillatory features which are associated with the standing waves on the reflector. The mutual coupling between feed units is quantified with S-parameters, which decrease as the distance between the two feeds increases. Based on the simulated S-parameters, we estimate the correlated noise which has been seen in the visibility data, and the results show very good agreement with the data in both magnitude and frequency structures. These results provide useful insights on the problem of 21 cm signal extraction for real instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification and reconstruction of low-energy electrons in the ProtoDUNE-SP detector

Measurements of electrons from 𝜈𝑒 interactions are crucial for the Deep Underground Neutrino Experiment (DUNE) neutrino oscillation program, as well as searches for physics beyond the standard model, supernova neutrino detection, and solar neutrino measurements. This article describes the selection and reconstruction of low-energy (Michel) electrons in the ProtoDUNE-SP detector. ProtoDUNE-SP is one of the prototypes for the DUNE far detector, built and operated at CERN as a charged particle test beam experiment. A sample of low-energy electrons produced by the decay of cosmic muons is selected with a purity of 95%. This sample is used to calibrate the low-energy electron energy scale with two techniques. An electron energy calibration based on a cosmic ray muon sample uses calibration constants derived from measured and simulated cosmic ray muon events. Another calibration technique makes use of the theoretically well-understood Michel electron energy spectrum to convert reconstructed charge to electron energy. In addition, the effects of detector response to low-energy electron energy scale and its resolution including readout electronics threshold effects are quantified. Finally, the relation between the theoretical and reconstructed low-energy electron energy spectra is derived, and the energy resolution is characterized. The low-energy electron selection presented here accounts for about 75% of the total electron deposited energy. After the addition of lost energy using a Monte Carlo simulation, the energy resolution improves from about 40% to 25% at 50 MeV. These results are used to validate the expected capabilities of the DUNE far detector to reconstruct low-energy electrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Characterization of the Polarization Beam Response of SPT-3G Using Point Sources

Precise measurements of cosmic microwave background (CMB) polarization require rigorous control of instrumental systematics. For the South Pole Telescope's third-generation camera (SPT-3G), which observes in three bands centered near 95, 150, and 220 GHz, accurate beam characterization is critical for interpreting the polarized mm-wave sky. We present direct measurements of SPT-3G's polarized beam response from observations of 100 bright extragalactic point sources. Previous SPT-3G power spectrum analyses introduced a phenomenological parameter, $β_{\rm pol}$, to describe the polarization preserved in beam sidelobes, and found evidence for significant depolarization from the requirement of inter-frequency polarization power spectrum consistency. Our direct measurements yield $β_{\rm pol}=0.89\pm0.10$ at 95 GHz, $1.08\pm0.10$ at 150 GHz, and $0.90\pm0.22$ at 220 GHz, indicating minimal sidelobe depolarization. We validate these results with systematic tests of posterior sampling versus bootstrap resampling, real-space versus Fourier-space analysis, temperature-to-polarization leakage handling, covariance determination, and source selection. Compared to values inferred from previous cosmological analyses, our results differ by an effective $1.3σ$. This apparent discrepancy is model dependent, because the point source analysis derives much of its $β_{\rm pol}$ constraining power from higher multipoles than the power spectrum analysis. These measurements therefore admit three explanations for the frequency-dependent residuals observed in the power spectrum analysis: a statistical fluctuation, the need for more sophisticated polarized beam models, or systematics other than beam depolarization.

de Haan, T. [KEK, Tsukuba]↗

Analysis and Validation of Spectral Irradiance Simulations for 75 kW Bifacial Solar Test Field

This work investigates how the spectrum of irradiance incident on the rear of bifacial modules impacts their performance. Light incident on the rear of bifacial modules can be reflected from the ground, mounting structures, and other nearby objects, causing both the intensity and spectrum to be modified. As a result, PV cells and sensors with different spectral responses report different values for the rear irradiance, leading to increased uncertainty when modeling performance. Here, we calculate the spectral irradiance incident on the rear of modules through raytrace simulations and validate with measured field data collected from a 75kW single-axis-tracked bifacial test site. Spectral responses for different sensors and PV cells are applied and compared with field measurements for four days. Based on these results, a method for improving non-spectral simulations is proposed. In addition, a linear regression is applied to the modeled spectral results as a method to gain insight into the contributions of ground reflected light to total rear irradiance.

bifacial photovoltaics↗

Deep learning for exploring ultra-thin ferroelectrics with highly improved sensitivity of piezoresponse force microscopy

Hafnium oxide-based ferroelectrics have been extensively studied because of their existing ferroelectricity, even in ultra-thin film form. However, studying the weak response from ultra-thin film requires improved measurement sensitivity. In general, resonance-enhanced piezoresponse force microscopy (PFM) has been used to characterize ferroelectricity by fitting a simple harmonic oscillation model with the resonance spectrum. However, an iterative approach, such as traditional least squares (LS) fitting, is sensitive to noise and can result in the misunderstanding of weak responses. In this study, we developed the deep neural network (DNN) hybrid with deep denoising autoencoder (DDA) and principal component analysis (PCA) to extract resonance information. The DDA/PCA-DNN improves the PFM sensitivity down to 0.3 pm, allowing measurement of weak piezoresponse with low excitation voltage in 10-nm-thick Hf 0.5 Zr 0.5 O 2 thin films. Our hybrid approaches could provide more chances to explore the low piezoresponse of the ultra-thin ferroelectrics and could be applied to other microscopic techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light-Induced Melting of Competing Stripe Orders without Introducing Superconductivity in La 2 − x Ba x CuO 4

The ultrafast manipulation of quantum material has led to many novel and significant discoveries. Among them, the light-induced transient superconductivity in cuprates achieved by melting competing stripe orders represents a highly appealing accomplishment. However, recent investigations have shown that the notion of photoinduced superconductivity remains a topic of controversy, and its elucidation solely through c -axis time-resolved terahertz spectroscopy remains an arduous task. Here, we measure the in-plane and out-of-plane transient terahertz responses simultaneously in the stripe-ordered nonsuperconducting La 2 − x Ba x CuO 4 after near-infrared excitations. We find that although a pump-induced reflectivity edge appears in the c -axis reflectance spectrum, the reflectivity along the CuO 2 planes decreases simultaneously, indicating an enhancement in the scattering rate of quasiparticles. This in-plane transient response is clearly distinct from the features associated with superconducting condensation. Therefore, we conclude the out-of-plane transient responses cannot be explained by an equivalent of Josephson tunneling. Notably, those pump-induced terahertz responses remain consistent even when we vary the near-infrared optical pump wavelengths and hole concentrations. Our results provide critical evidence that transient three-dimensional superconductivity cannot be induced by melting the competing stripe orders with pump pulses whose photon energy is much higher than the superconducting gap of cuprates. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Oxygen Vacancy Injection as a Pathway to Enhancing Electromechanical Response in Ferroelectrics

Since their discovery in late 1940s, perovskite ferroelectric materials have become one of the central objects of condensed matter physics and materials science due to the broad spectrum of functional behaviors they exhibit, including electro-optical phenomena and strong electromechanical coupling. In such disordered materials, the static properties of defects such as oxygen vacancies are well explored but the dynamic effects are less understood. In this work, the first observation of enhanced electromechanical response in BaTiO3 thin films is reported driven via dynamic local oxygen vacancy control in piezoresponse force microscopy (PFM). A persistence in peizoelectricity past the bulk Curie temperature and an enhanced electromechanical response due to a created internal electric field that further enhances the intrinsic electrostriction are explicitly demonstrated. The findings are supported by a series of temperature dependent band excitation PFM in ultrahigh vacuum and a combination of modeling techniques including finite element modeling, reactive force field, and density functional theory. Furthermore, this study shows the pivotal role that dynamics of vacancies in complex oxides can play in determining functional properties and thus provides a new route toward– achieving enhanced ferroic response with higher functional temperature windows in ferroelectrics and other ferroic materials.

36 MATERIALS SCIENCE↗

Influence of triangularity on the plasma response to resonant magnetic perturbations

The effect of the axisymmetric plasma shape on the non-axisymmetric plasma response to resonant magnetic perturbations is investigated in experiment and modeling for the DIII-D, EAST and ASDEX Upgrade tokamaks. Systematically modeling the effect of the triangularity, whilst keeping other equilibrium quantities largely unchanged, reveals that the plasma response is strongly suppressed at high triangularity compared to that at low triangularity. This is validated through targeted comparison with experiments at DIII-D, EAST, and ASDEX Upgrade. DIII-D and EAST magnetic measurements are used to validate simulations, while at ASDEX Upgrade the plasma edge displacement is measured. Both experiments and modeling find a reduced magnetic plasma response on the high-field side at high triangularity across devices. Multi-modal analysis of the simulation results extracts the mode structure and applied spectrum dependence of each mode. The amplitude of the dominant mode reveals similar trends with the edge resonance and radial displacement near the X-point, which suggests that the multi-mode plasma response provides another way to understand the edge localized mode (ELM) control physics. The plasma response is strongly reduced at high triangularity compared to that at low triangularity, which implies different ELM control effects as shaping is varied. Furthermore, these findings indicate that the plasma shape should be taken into consideration when designing an RMP-ELM control strategy in experiment, and that predictive plasma response calculations can be used to maximize access to RMP-ELM control in future devices by maximizing the coupling between coils and the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spin-Forbidden Excitations in the Magneto-optical Spectra of CrI 3 Tuned by Covalency

Spin-forbidden (Δ⁢𝑆 ≠0) multiplet excitations and their coupling to magnetic properties are of increasing importance for magneto-optical studies of correlated materials. Nonetheless, the mechanisms for optically brightening these transitions and their generality remain poorly understood. Here, we report magnetic circular dichroism (MCD) spectroscopy on the van der Waals ferromagnet (FM) CrI 3 . Previously unreported spin-forbidden (Δ⁢𝑆 =1) 4 𝐴 2⁢g → 2 𝐸 g / 2 𝑇 1⁢g Cr 3+ 𝑑⁢𝑑 excitations are observed near the ligand-to-metal charge-transfer excitation threshold. The assignment of these excitations and their Cr 3+ multiplet character is established through complementary Cr 𝐿 3 -edge resonant inelastic x-ray scattering measurements along with charge-transfer multiplet calculations and chemical trends in the chromium trihalide series (Cr⁢𝑋 3 , 𝑋 = Cl, Br, I). We utilize the high sensitivity of MCD spectroscopy to study the thickness-dependent optical response. The spin-forbidden excitations remain robust down to the monolayer limit, and we observe a significant magnetic-field dependence of the MCD spectrum across the antiferromagnetic-to-FM transition in few-layer samples. We preliminarily attribute this behavior to changes in the metal-ligand covalency with magnetic state. Our results clarify the magneto-optical response of CrI 3 and identify covalency as a central mechanism for the brightening and field tunability of spin-forbidden multiplet excitations.

36 MATERIALS SCIENCE↗

Sensitivity of the simulation of passive neutron emission from UF 6 cylinders to the uncertainties in both 19 F(α,n) energy spectrum and thick target yield of 234 U in UF 6

Interest in safeguards verification measurements using passive thermal neutron counting to assay 235 U content in large 30B UF 6 canisters has grown in recent years. Here, the prohibitively high cost and impracticality of using reference 30B calibration cylinders extensively will likely make accurate simulations of increasing interest. Accuracy of the simulated response will define the confidence in the predicted response and the extent to which simulations can reasonably be relied upon. With 234 U driven 19 F(α, n) reactions being the main neutron source in low enriched UF 6 the uncertainties of the 19 F(α, n) energy spectrum and the thick target yield of 234 U in UF 6 propagate into the uncertainty in the predicted response and represent a major influence of basic nuclear data. Here sensitivity of the simulated total (Singles) and coincidence (Doubles) count rates are assessed for the Passive Neutron Enrichment Meter using six potential 19 F(α, n) neutron energy spectra over a range of enrichments and material distributions. The results indicate that variations in the Singles and Doubles due to simulated (α, n) neutron spectrum are less than 1.5% for this set of simulated neutron spectra, with dependence varying inversely with enrichment. Singles uncertainty is only slightly less than that of the thick target 19 F(α, n) yield corresponding to the primary neutron source, whereas the 19 F(α, n) yield dependence of the Doubles is reduced by the non-negligible 238 U(SF) coincident neutron emissions. Based on available thick target 19 F(α, n) yield estimates the uncertainty is on the order of 5%, establishing this as the main nuclear data limitation when simulating thermal neutron detectors response for 30B UF 6 storage cylinders. Based on these findings, it appears that the measurement and evaluation of the thick target 19 F(α, n) yield for uranium hexafluoride is due.

19F(α,n) neutron spectrum↗

Measurement of the energy response of the ATLAS calorimeter to charged pions from $W^{\pm }\rightarrow \tau ^{\pm }(\rightarrow \pi ^{\pm }\nu _{\tau })\nu _{\tau }$ events in Run 2 data

The energy response of the ATLAS calorimeter is measured for single charged pions with transverse momentum in the range 10 < p T < 300 GeV. The measurement is performed using 139 fb –1 of LHC proton–proton collision data at √s = 13 TeV taken in Run 2 by the ATLAS detector. Charged pions originating from τ-lepton decays are used to provide a sample of high-p T isolated particles, where the composition is known, to test an energy regime that has not previously been probed by in situ single-particle measurements. The calorimeter response to single-pions is observed to be overestimated by ~2% across a large part of the p T spectrum in the central region and underestimated by ~4% in the endcaps in the ATLAS simulation. The uncertainties in the measurements are ≲1% for 15 < p T < 185 GeV in the central region. To investigate the source of the discrepancies, the width of the distribution of the ratio of calorimeter energy to track momentum, the energies per layer and response in the hadronic calorimeter are also compared between data and simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗