Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Buildings Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Design and operation of a solar heating and cooling system for a residential size building

The first year of operation of solar house is discussed. Selected design information, together with a brief system description is included. The house was equipped with an integrated solar heating and cooling system which uses fully automated state-of-the art. Evaluation of the data indicate that the solar house heating and cooling system is capable of supplying nearly 100 percent of the thermal energy required for heating and approximately 50 percent of the thermal energy required to operate the absorption cycle air conditioner.

Littles, J. W.↗

Structural Considerations for Solar Installers: An approach for small, simplified solar installations or retrofits

Structural Considerations for Solar Installers provides a comprehensive outline of structural considerations associated with simplified solar installations and recommends a set of best practices installers can follow when assessing such considerations. Information in the manual comes from engineering and solar experts as well as case studies. The objectives of the manual are to ensure safety and structural durability for rooftop solar installations and to potentially accelerate the permitting process by identifying and remedying structural issues prior to installation. The purpose of this document is to provide tools and guidelines for installers to help ensure that residential photovoltaic (PV) power systems are properly specified and installed with respect to the continuing structural integrity of the building.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Field Assessment of Air Barriers at the Building Envelope Systems Test (BEST) Laboratory Phase 1

The Buildings Technologies Research and Integration Center (BTRIC) at the Oak Ridge National Laboratory (ORNL) performed field evaluations of 24 wall panels with different types of air barriers that are commonly used in residential and commercial construction. Field assessments were conducted from September 2009 until August 2010 at the Building Envelope Systems Test (BEST) laboratory, which is located at Syracuse University, Syracuse, NY. This project is a cooperative research among ORNL, the Air Barrier Association of America (ABAA), Syracuse University, and the New York State Energy Research and Development Authority (NYSERDA).

Hun, Diana E.↗

Integrated Technology Air Cleaners (ITAC): Design and Evaluation

The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

54 ENVIRONMENTAL SCIENCES↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Selecting Ventilation Systems for Existing Homes (Fact Sheet)

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Roof-integrated radiative air-cooling system to achieve cooler attic for building energy saving

The building attic usually subjects to substantial solar heat gain and has much higher temperature compared to the conditioned living space during the day, especially in summer and in hot areas. Reducing attic temperature can reduce cooling energy consumption in buildings. However, conventional techniques such as cool roof or attic ventilation, suffer from either heating penalty in winter or limited attic temperature reduction. In this work, a new roof-integrated radiative air-cooling system is introduced, which couples radiative sky cooling with attic ventilation to reduce attic temperature. A radiative air cooler with 1.08 m 2 surface area is constructed using a recently developed daytime radiative sky cooling metamaterial [Zhai et al., Science 355, pp. 1062–1066, 2017]. Experimental tests show that sub-ambient air cooling is achieved throughout 24-h day-and-night cycle in a summer day with clear sky conditions. Depending on air flow rates, measured sub-ambient temperature reductions of air are 5–8°C at night and 3–5°C at noon under direct sunlight, respectively. An in-house model is first developed for the radiative air-cooling system, the model is then coupled with EnergyPlus to study annual energy saving of buildings. The performance of the radiative air-cooling system is compared with three reference systems: shingle roof, attic ventilation, and cool roof. Results show that for a single-family house, attic temperature can be substantially reduced by 15.5–21.0°C, varying with attic insulation level, compared to shingle roof on typical summer days. Compared to a shingle roof (solar reflectance 0.25, thermal emittance 0.9) residential building with attic insulations of R-30 (RSI-5.28), R-10 (RSI-1.76), and R-0.8 (RSI-0.14), the roof-integrated radiative air-cooling system can achieve annual cooling energy savings of 0.4–1.5 kWh/m 2 (4.6–18.8%), 1.2–3.6 kWh/m 2 (10.2–41.4%), and 3.7–11.8 kWh/m 2 (26.5–76.1%) respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing the Next Generation of Net Zero Professionals through the Race to Zero: Preprint

The U.S. Department of Energy Race to Zero inspires collegiate students to become the next generation of building science professionals through a zero energy ready buildings design challenge. As industry looks to close the gap to more net zero energy construction, Race to Zero teams are tasked with exploring how to apply net zero across climates both nationally and internationally. For the past four annual competition events, teams developed comprehensive, integrated residential designs with industry partners that are market-ready and innovative. While each team addressed home design differently through upgrades to existing production builder plans, new developments to meet community needs, or existing building renovations and retrofits, the competition requires their solutions meet zero energy ready residential standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing the Next Generation of Net Zero Professionals through the Race to Zero

The U.S. Department of Energy Race to Zero inspires collegiate students to become the next generation of building science professionals through a zero energy ready buildings design challenge. As industry looks to close the gap to more net zero energy construction, Race to Zero teams are tasked with exploring how to apply net zero across climates both nationally and internationally. For the past four annual competition events, teams developed comprehensive, integrated residential designs with industry partners that are market-ready and innovative. While each team addressed home design differently through upgrades to existing production builder plans, new developments to meet community needs, or existing building renovations and retrofits, the competition requires their solutions meet zero energy ready residential standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt model is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.

14 SOLAR ENERGY↗

Tracking the Sun III; The Installed Cost of Photovoltaics in the United States from 1998-2009

Installations of solar photovoltaic (PV) systems have been growing at a rapid pace in recent years. In 2009, approximately 7,500 megawatts (MW) of PV were installed globally, up from approximately 6,000 MW in 2008, consisting primarily of grid-connected applications. With 335 MW of grid-connected PV capacity added in 2009, the United States was the world's fourth largest PV market in 2009, behind Germany, Italy, and Japan. The market for PV in the United States is driven by national, state, and local government incentives, including up-front cash rebates, production-based incentives, requirements that electricity suppliers purchase a certain amount of solar energy, and federal and state tax benefits. These programs are, in part, motivated by the popular appeal of solar energy, and by the positive attributes of PV - modest environmental impacts, avoidance of fuel price risks, coincidence with peak electrical demand, and the possible deployment of PV at the point of use. Given the relatively high cost of PV, however, a key goal of these policies is to encourage cost reductions over time. Therefore, as policy incentives have become more significant and as PV deployment has accelerated, so too has the desire to track the installed cost of PV systems over time, by system characteristics, by system location, and by component. Despite the significant year-on-year growth, however, the share of global and U.S. electricity supply met with PV remains small, and annual PV additions are currently modest in the context of the overall electric system. To address this need, Lawrence Berkeley National Laboratory initiated a report series focused on describing trends in the installed cost of grid-connected PV systems in the United States. The present report, the third in the series, describes installed cost trends from 1998 through 2009, and provides preliminary cost data for systems installed in 2010. The analysis is based on project-level cost data from approximately 78,000 residential and non-residential PV systems in the U.S., all of which are installed at end-use customer facilities (herein referred to as 'customer-sited' systems). The combined capacity of systems in the data sample totals 874 MW, equal to 70% of all grid-connected PV capacity installed in the United States through 2009 and representing one of the most comprehensive sources of installed PV cost data for the U.S. The report also briefly compares recent PV installed costs in the United States to those in Germany and Japan. Finally, it should be noted that the analysis presented here focuses on descriptive trends in the underlying data, serving primarily to summarize the data in tabular and graphical form; later analysis may explore some of these trends with more-sophisticated statistical techniques. The report begins with a summary of the data collection methodology and resultant dataset (Section 2). The primary findings of the analysis are presented in Section 3, which describes trends in installed costs prior to receipt of any financial incentives: over time and by system size, component, state, system ownership type (customer-owned vs. third party-owned), host customer segment (residential vs. commercial vs. public-sector vs. non-profit), application (new construction vs. retrofit), and technology type (building-integrated vs. rack-mounted, crystalline silicon vs. thin-film, and tracking vs. fixed-axis). Section 4 presents additional findings related to trends in PV incentive levels over time and among states (focusing specifically on state and utility incentive programs as well as state and federal tax credits), and trends in the net installed cost paid by system owners after receipt of such incentives. Brief conclusions are offered in the final section, and several appendices provide additional details on the analysis methodology and additional tabular summaries of the data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tracking the Sun II: The Installed Cost of Photovoltaics in the U.S. from 1998-2008

Installations of solar photovoltaic (PV) systems have been growing at a rapid pace in recent years. In 2008, 5,948 MW of PV was installed globally, up from 2,826 MW in 2007, and was dominated by grid-connected applications. The United States was the world's third largest PV market in terms of annual capacity additions in 2008, behind Spain and Germany; 335 MW of PV was added in the U.S. in 2008, 293 MW of which came in the form of grid-connected installations. Despite the significant year-on-year growth, however, the share of global and U.S. electricity supply met with PV remains small, and annual PV additions are currently modest in the context of the overall electric system. The market for PV in the U.S. is driven by national, state, and local government incentives, including up-front cash rebates, production-based incentives, requirements that electricity suppliers purchase a certain amount of solar energy, and Federal and state tax benefits. These programs are, in part, motivated by the popular appeal of solar energy, and by the positive attributes of PV - modest environmental impacts, avoidance of fuel price risks, coincidence with peak electrical demand, and the location of PV at the point of use. Given the relatively high cost of PV, however, a key goal of these policies is to encourage cost reductions over time. Therefore, as policy incentives have become more significant and as PV deployment has accelerated, so too has the desire to track the installed cost of PV systems over time, by system characteristics, by system location, and by component. To address this need, Lawrence Berkeley National Laboratory initiated a report series focused on describing trends in the installed cost of grid-connected PV systems in the U.S. The present report, the second in the series, describes installed cost trends from 1998 through 2008. The analysis is based on project-level cost data from more than 52,000 residential and non-residential PV systems in the U.S., all of which are installed at end-use customer facilities (herein referred to as 'customer-sited' systems). The combined capacity of systems in the data sample totals 566 MW, equal to 71% of all grid-connected PV capacity installed in the U.S. through 2008, representing the most comprehensive source of installed PV cost data for the U.S.9 The report also briefly compares recent PV installed costs in the U.S. to those in Germany and Japan. Finally, it should be noted that the analysis presented here focuses on descriptive trends in the underlying data, and is primarily summarized in tabular and graphical form; later analysis may explore some of these trends with more-sophisticated statistical techniques. The report begins with a summary of the data collection methodology and resultant dataset (Section 2). The primary findings of the analysis are presented in Section 3, which describes trends in installed costs prior to receipt of any financial incentives: over time and by system size, component, state, customer segment (residential vs. commercial vs. public-sector vs. non-profit), application (new construction vs. retrofit), and technology type (building-integrated vs. rack-mounted, crystalline silicon vs. thin-film, and tracking vs. rack-mounted). Section 4 presents additional findings related to trends in PV incentive levels over time and among states (focusing specifically on state and utility incentive programs as well as state and Federal tax credits), and trends in the net installed cost paid by system owners after receipt of such incentives. Brief conclusions are offered in the final section.

14 SOLAR ENERGY↗

A modeling framework for optimal energy management of a residential building

Residential buildings are currently equipped with energy production facilities, e.g., solar rooftops and batteries, which in conjunction with smart meters, can function as smart energy hubs coordinating the loads and the resources in an optimal manner. This paper presents a mathematical model for the optimal energy management of a residential building and proposes a centralized energy management system (CEMS) framework for off-grid operation. The model of each component of the hub is integrated within the CEMS. The optimal decisions are determined in real-time by considering these models with realistic parameter settings and customer preferences. Model predictive control (MPC) is used to adapt the optimal decisions on a receding horizon to account for the deviations in the system inputs. Simulation results are presented to demonstrate the feasibility and effectiveness of the proposed CEMS framework. Results show that the proposed CEMS can reduce the energy cost and energy consumption of the customers by approximately 17% and 8%, respectively, over a day. In conclusion, using the proposed CEMS, the total charging cycles of the ESS were reduced by more than 50% in a day.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Advanced Extended Plate and Beam Wall System in a Cold-Climate House, Mount Joy, Pennsylvania

This report presents the design and evaluation of a innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2011 EnergyValue Housing Award Report

The EnergyValue Housing Award (EVHA), an integral part of the U.S. Department of Energy’s Building America (BA) program, seeks to improve and expand the energy efficiency of residential construction nationwide by honoring builders and remodelers and awarding highly efficient homes. Receiving EVHA recognition helps builders and remodelers communicate the value of energy efficiency to prospective customers and distinguish their homes from those built by more traditional residential construction companies. It also provides opportunities for EVHA winning builders and remodelers to set an example for improving the quality and performance of homes throughout the country. Each year, the project scope of the EVHA includes the application and judging processes, developing the EVHA publication, updating the program and application for the next year, hosting the EVHA banquet, and outreach and technical support. Following the award banquet, the NAHB Research Center evaluates the energy performance of that year’s EVHA winning houses. This work is primarily comprised of estimating the energy savings of each home/ or housing unit over the BA Benchmark using energy simulation software and procedures developed by the BA program. The energy evaluations serve as a quantitative measure of the energy efficiency of the units which the judges decided merited an award. As part of this work, the NAHB Research Center Industry Partnership (NAHBRC-IP) for High Performing Homes strives to make new and existing homes more energy efficient, durable, and affordable through research and development as one of the U.S. Department of Energy’s BA teams. Each year, through the EVHA, builder and remodeler partners work with industry partners in a variety of climates endeavor to reach the energy efficiency targets of the BA program. (Department of Energy 2012) This report details the simulation tool(s) and energy modeling methodology followed in making the energy efficiency estimates and documents the estimated performance of the EVHA award winning houses in comparison with the BA Benchmark and the associated House Simulation Protocols (HSPs). A summary of each building and its features is included with a brief description of the project and the judges’ comments. The purpose of this report is to assess the energy performance of the 2011 EVHA winners and to align the EVHA program with the BA program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Next Generation Integrated PV Products Cost and Workflow Analysis (Final Report)

Residential photovoltaic (PV) costs have fallen consistently for over a decade (Ardani et al. 2018). DOE has subsequently developed a new residential PV cost target for 2030 of $0.05/kilowatt hour (SETO 2023). Ardani et al. (2018) conclude that integrated roofing and PV (RIPV) products may be key to achieving the residential target for both new construction and retrofit residential PV. In RIPV, the PV product is incorporated into or replaces the roofing material. RIPV systems can use conventional crystalline or thin-film technologies, may be aesthetically attractive alternatives to traditional racked and mounted PV systems, and may increase building property values (Cook et al. 2023). These products also have the potential to provide customer acquisition, labor, and equipment cost savings over traditional, racked and mounted residential rooftop PV and several companies have recently introduced integrated roofing and PV (RIPV) products (Cook et al. 2023). In 2022, Tesla was the market leader, representing 94% of RIPV capacity installed in 2022 through its Solar Roof offering, while GAF Energy and its Timberline Solar product was second capturing 3% (Feldman et al. 2023). In this project, NREL analyzed three research questions: (1) How do current RIPV products compare to racked and mounted PV in terms of costs, install times and processes? (2) How are RIPV products installed and are there opportunities for cost savings? (3) What are the key barriers to expanding market opportunities for integrating solar and roofing products? In this project, we explored residential RIPV cost reduction opportunities by analyzing installation processes. Our study documented residential RIPV installations at two reroofing sites (20.52 kilowatts) and the equivalent of nine new construction sites (71.75 kW) in California through a methodology known as time and motion study. We also conducted 15 interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration.

14 SOLAR ENERGY↗