Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

Gross Alpha Beta Radioactivity in Air Filters Measured by Ultra Low Level alpha/beta Counter

Study of radioactivity in air as very important for life is done regularly using different methods in every country. As a result of nuclear reactors, atomic centrals, institutions and laboratories, which use the radioactivity substances in open or closed sources, there are a lot radioactive wastes. Mixing of these wastes after treatment with rivers and lakes waters makes very important control of radioactivity. At the other side nuclear and radiological accidents are another source of the contamination of air and water. Due to their radio toxicity, especially those of Sr{sup 90}, Pu{sup 239}, etc. a contamination hazard for human begins exist even at low concentration levels. Measurements of radioactivity in air have been performed in many parts of the world mostly for assessment of the doses and risk resulting from consuming air. In this study we present the results of international comparison organized by IAEA Vienna, Austria for the air filters spiked with unknown Alpha and Beta Activity. For the calibration of system we used the same filters spiked: a) with Pu-239 as alpha source; b) Sr-90 as beta source and also the blank filter. The measurements of air filter samples after calibration of the system are done with Ultra Low Level alpha/beta Counter (MPC 9604) Protean Instrument Corporation. The high sensitivity of the system for the determination of the Gross Alpha and Beta activity makes sure detection of low values activity of air filters. Our laboratory results are: Aalpha = (0.19+-0.01) Bq/filter and Aalpha(IAEA) = (0.17+-0.009) Bq/filter; A{sub b}eta = (0.33+-0.009) Bq/filter and A{sub b}eta (IAEA) = (0.29+-0.01) Bq/filter. As it seems our results are in good agreement with reference values given by IAEA (International Atomic Energy Agency).

54 ENVIRONMENTAL SCIENCES↗

Lithium electric dipole polarizability

The electric dipole polarizability of the lithium atom in the ground state is calculated including relativistic and quantum electrodynamics corrections. The obtained result {alpha}{sub E}=164.0740(5) a.u. is in good agreement with the less accurate experimental value of 164.19(1.08) a.u. The small uncertainty of about 3 parts per 10{sup 6} comes from the approximate treatment of quantum electrodynamics corrections. Our theoretical result can be considered as a benchmark for more general atomic structure methods and may serve as a reference value for the relative measurement of polarizabilities of the other alkali-metal atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

Plasma focus ion beam fluence and flux—For various gases

A recent paper derived benchmarks for deuteron beam fluence and flux in a plasma focus (PF) [S. Lee and S. H. Saw, Phys. Plasmas 19, 112703 (2012)]. In the present work we start from first principles, derive the flux equation of the ion beam of any gas; link to the Lee Model code and hence compute the ion beam properties of the PF. The results show that, for a given PF, the fluence, flux, ion number and ion current decrease from the lightest to the heaviest gas except for trend-breaking higher values for Ar fluence and flux. The energy fluence, energy flux, power flow, and damage factors are relatively constant from H{sub 2} to N{sub 2} but increase for Ne, Ar, Kr and Xe due to radiative cooling and collapse effects. This paper provides much needed benchmark reference values and scaling trends for ion beams of a PF operated in any gas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-approach assessment of the spatial distribution of the specific yield: application to the Crau plain aquifer, France

Spatially distributed values of the specific yield, a fundamental parameter for transient groundwater mass balance calculations, were obtained by means of three independent methods for the Crau plain, France. In contrast to its traditional use to assess recharge based on a given specific yield, the water-table fluctuation (WTF) method, applied using major recharging events, gave a first set of reference values. Then, large infiltration processes recorded by monitored boreholes and caused by major precipitation events were interpreted in terms of specific yield by means of a one-dimensional vertical numerical model solving Richards’ equations within the unsaturated zone. Finally, two gravity field campaigns, at low and high piezometric levels, were carried out to assess the groundwater mass variation and thus alternative specific yield values. The range obtained by the WTF method for this aquifer made of alluvial detrital material was 2.9– 26%, in line with the scarce data available so far. The average spatial value of specific yield by the WTF method (9.1%) is consistent with the aquifer scale value from the hydro-gravimetric approach. In this investigation, an estimate of the hitherto unknown spatial distribution of the specific yield over the Crau plain was obtained using the most reliable method (the WTF method). A groundwater mass balance calculation over the domain using this distribution yielded similar results to an independent quantification based on a stable isotope-mixing model. This agreement reinforces the relevance of such estimates, which can be used to build a more accurate transient hydrogeological model.

58 GEOSCIENCES↗

Vertical detachment energies of ammonia cluster anions using self-interaction-corrected methods

Systems with weakly bound extra electrons impose great challenges to semilocal density functional approximations (DFAs), which suffer from self-interaction errors. Small ammonia clusters are one such example of weakly bound anions where the extra electron is weakly bound. We applied two self-interaction correction (SIC) schemes, viz., the well-known Perdew–Zunger and the recently developed locally scaled SIC (LSIC) with the local spin density approximation (LSDA), Perdew–Burke–Ernzerhof (PBE) generalized gradient approximation (GGA), and the SCAN meta-GGA functionals to calculate the vertical detachment energies (VDEs) of small ammonia cluster anions (NH3)n–. Our results show that the LSIC significantly reduces the errors in calculations of VDE with LSDA and PBE-GGA functionals leading to better agreement with the reference values calculated with coupled cluster singles and doubles with perturbative triples [CCSD(T)]. Accurate prediction of VDE as an absolute of the highest occupied molecular orbital (HOMO) is challenging for DFAs. Our results show that VDEs estimated from the negative of HOMO eigenvalues with the LSIC-LSDA and Perdew–Zunger SIC-PBE are within 11 meV of the reference CCSD(T) results. Here, the LSIC method performs consistently well for the VDE estimates, from both the total energy differences and the absolute HOMO eigenvalues.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Rotation and Manure Effects in an Iowa Farm Soil Health Assessment

Core Ideas Farms with known management histories contribute to soil health research. Rotation‐based systems may increase soil organic carbon when combined with appropriate tillage. Inherent soil properties must be considered in soil health assessments. Rotation effects were more noticeable than manure effects on soil health groupings. Data from on‐farm sites with known management histories are needed to quantify soil biological, chemical, and physical properties influencing carbon stocks and soil health. Surface (0–15 cm) and deep core (0–122 cm) soil samples were collected from fields under two rotations in Boone County, IA. The first was a 5‐yr corn [ Zea mays (L.)], soybean [ Glycine max (L.) Merr.], corn, oat [ Avena sativa (L.)], and alfalfa [ Medicago sativa (L.)] rotation to which 0, 18, or 36 Mg ha −1 of a manure/biosolids mixture was applied prior to planting corn. The second was an 8‐yr rotation with 6 yr of mixed grass and legume pasture followed by corn and an oat crop within which the pasture mixture was reestablished. Soil samples were collected evenly across the predominant soil map units (SMUs). Bulk density (BD), soil organic C (SOC), water‐stable aggregates (WSA), microbial biomass carbon (MBC), pH, Mehlich‐3 and diethylenetriaminepentaacetic acid (DTPA) extractable nutrients, electrical conductivity (EC), and nitrogen (total‐, NH 4 –, and NO 3 –N) were measured. Surface SOC data were consistent with Soil Survey values for the various SMUs. Crop rotation effects were more noticeable than manure/biosolid application rate effects. Data from this study were combined with previously published SOC data in Iowa. Results suggest extended rotation systems or those with cover crops may increase SOC 8 ± 4 g kg −1 compared to corn–soybean rotations (33 vs. 25 g kg −1 ). This study provides on‐farm reference values for soil health assessment tools and draws attention to the importance of inherent soil properties for these assessments.

54 ENVIRONMENTAL SCIENCES↗

The dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

dc power control for a liquid-fed resistojet

A simple breadboard power controller was designed and demonstrated for a new liquid-fed water resistojet. The 1-piece laboratory model thruster has an integrated vaporizer/superheater using a single heating element. Heater temperature was maintained at or near a preset reference value with the closed loop controller providing pulse width modulated (PWM) dc power into the thruster heater. A combined thruster, temperature readout, PWM transfer function was experimentally determined. This transfer function was used to design a proportional plus integral controller that demonstrated zero steady state error, conservative stability margins and adequate transient response to step changes in propellant flow rate, input voltage and temperature reference. Initial turn-on temperature overshoot from room temperature to a 650 C setpoint was 80 C. In addition, EMI was alleviated by reducing heater dI/dt and dV/dt using a simple diode-inductor-capacitor network. Based on limited initial tests, thruster preheat with no propellant flow was necessary to achieve stable system operation during startup. Breadboard power efficiency was 99 percent at 1 kW, and component mass was 0.4 kg excluding the power loss and mass of an input filter required for spacecraft integration.

Gruber, Robert P.↗

Methods of Attenuation Correction for the TRMM Precipitation Radar Data

The surface reference technique (SRT) has been studied extensively both theoretically and experimentally over the last decade. It is only with the launch of the Tropical Rain Measuring Mission (TRMM) Precipitation Radar, however, that we can begin to test directly whether the technique provides a reliable means of attenuation correction for spaceborne weather radars. Preliminary results indicate that the method yields results that are qualitatively reasonable when the rain rate is moderate or high and when the surface provides a stable reference value. The structure of the normalized radar cross section of the surface (NRCS), however, is highly complex in the sense that the statistics change with background type, incidence angle, location, and season. As a consequence of this, the reliability of the path attenuation estimate is not proportional simply to the amount of rain attenuation but to the rain attenuation relative to the inherent variability of the reference target. To illustrate the behavior of the SRT, several overpasses of the Hurricane Bonnie are shown. We also show that the proper choice of reference data set (spatial, temporal and global) can be critical to the success of the method.

Meneghini, Robert↗

The radius and ellipticity of Uranus from its occultation of SAO 158687

From occultation timings obtained from the Kuiper Airborne Observatory and from Cape Town for Mar. 10, 1977 occultation of SAO 158687 by Uranus, the equatorial radius, Re, of the planet has been determined to be 26,228 + or - 30 km and its ellipticity epsilon = 1 - Rp/Re = 0.033 + or - 0.007. These values refer to the 1.0 x 10 to the 14th/cu cm number-density level, under the assumption that the upper atmosphere is composed of H2 and He with a mean molecular weight mu = 2.20. The dominant source of uncertainty is the position of the center of the ring system, which was used to define the center of Uranus in our analysis. A rotation rate of 12.8 + or - 1.7 hours for the planet is implied by our value for the ellipticity, under the assumption that Uranus is in hydrostatic equilibrium below the 1.0 x 10 to the 14th/cu cm number density level.

Elliot, J. L.↗

Nuclear data uncertainty propagation and modeling uncertainty impact evaluation in neutronics core simulation

Uncertainty analysis is a critical requirement in reactor simulation as it is used to quantify the reliability of best-estimate calculation. A comprehensive uncertainty analysis should characterize all sources of uncertainties in a computationally-feasible and scientifically-defendable manner. Here we employ a well-established reduced order modeling (ROM) based uncertainty quantification methodology to propagate uncertainties throughout neutronic calculations. ROM relies on recent advances in randomized data mining techniques applied to large data streams. In our proposed implementation, the nuclear data uncertainties are first propagated from multi-group level through lattice physics calculation to generate few-group parameter uncertainties, described using a vector of mean values and a covariance matrix. Employing an ROM-based compression of the covariance matrix, the few-group uncertainties are then propagated through downstream core simulation in a computationally efficient manner. This straightforward approach, albeit efficient as compared to brute force forward and/or adjoint-based methods, often employs a number of assumptions that have been unquestioned in the literature of neutronic uncertainty analysis. This manuscript argues that these assumptions could introduce another source of uncertainty referred to as modeling uncertainties, whose magnitude needs to be quantified in tandem with nuclear data uncertainties. Thus, our primary goal is to explore the interactions between these two uncertainty sources in order to assess whether modeling uncertainties have an impact on parameter uncertainties. To explore this endeavor, the impact of a number of modeling assumptions on core attributes uncertainties is quantified. The study employs a CANDU reactor model, with Serpent and NEWT as lattice physics solvers and NESTLE-C as core simulator. The modeling assumptions investigated include those related with the uncertainty propagation method employed, e.g., deterministic vs. stochastic, the few-group energy structure employed to represent the cross-sections, the resonance treatment in lattice physics calculation, the reference values for the cross-section, and the number of samples employed to render ROM compression. Results indicate that some of the modeling assumptions could have a non-negligible impact on the core responses propagated uncertainties, highlighting the need for a more comprehensive approach to combine parameter and modeling uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

How Accurate Is Density Functional Theory at Predicting Dipole Moments? An Assessment Using a New Database of 200 Benchmark Values

We present that dipole moments are a simple, global measure of the accuracy of the electron density of a polar molecule. Dipole moments also affect the interactions of a molecule with other molecules as well as electric fields. To directly assess the accuracy of modern density functionals for calculating dipole moments, we have developed a database of 200 benchmark dipole moments, using coupled cluster theory through triple excitations, extrapolated to the complete basis set limit. This new database is used to assess the performance of 88 popular or recently developed density functionals. The results suggest that double hybrid functionals perform the best, yielding dipole moments within about 3.6-4.5% regularized RMS error versus the reference values - which is not very different from the 4% regularized RMS error produced by coupled cluster singles and doubles. Many hybrid functionals also perform quite well, generating regularized RMS errors in the 5-6% range. Lastly, some functionals, however, exhibit large outliers, and local functionals in general perform less well than hybrids or double hybrids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Investigation of the effect of local atomic polarization on field-enhanced ion transport in insulating binary oxides: The case of CeO 2

Over the course of more than 70 years, several theoretical models for electric field-enhanced ion diffusion in crystalline insulators have been presented. However, there is no assessment of the validity of these models despite the urge to have a correct description of field-enhanced ion diffusion in several emerging technologies. Herein, an assessment of five models was carried out by computing the field-dependent migration enthalpy ΔH mig (E) for the oxide ion in CeO 2 . The input to these models is the zero-field and zero-temperature migration pathway and/or the activation barrier obtained from an interatomic potential. ΔH mig (E) from these models was compared with reference values obtained from a set of classical molecular-dynamics simulations in the temperature range of 1000 ≤ T ≤ 1600 K and the electric field range of 0 ≤ E ≤ 30 MV/cm. It is revealed that the most successful theoretical models are those that consider local polarization effects induced in the diffusing ion itself and its vicinity. However, all the models did not account for the effect of the electric field and finite temperature on the local polarization, leading to discrepancies between the predicted and the reference ΔH mig (E), particularly at high fields. By comparing results from a rigid-ion potential and a polarizable core-shell potential, it is concluded that an intraionic polarization degree of freedom in the polarizable potential is an important factor in predicting ΔH mig (E), regardless of the field-enhanced diffusion model particularly for low to moderate field. Finally, future more accurate treatments should consider the field- and temperature-dependent interionic and intraionic local polarization effects.

36 MATERIALS SCIENCE↗

Precipitable Water Vapor Characterization In The Gulf Of Cadiz Region (Southwestern Spain) Based On Sun Photometer, GPS And Radiosonde Data

Column integrated water vapor (IWV) data in the Gulf of Cádiz area (Southwestern Spain) are analyzed during the period 2001 to 2005 with two aims: 1) to establish the climatology over this area using three different techniques, such as Sun-Photometer (SP), Global Position System (GPS) and Radiosondes, and 2) to take advantage of this comparative process to assess the quality of radiometric IWV data collected at the RIMA-AERONET station. The 5 years of climatological series gives a mean value of about 2 cm (STD=0.72) and a clear seasonal behavior as a general feature, with the highest values in summer and the lowest in winter. In the multi-annual monthly means basis, the highest values are reached in August-September, with a mean value of 2.5-2.6 cm, whereas the lowest are obtained in January-February, with an average of 1.4-24 1.5. However the most relevant results for this area is the observed local minimum in July, occurring during the maximum of desert dust intrusions in the southern Iberian Peninsula. A comparison process allows us to evaluate the agreement of IWV data sets between these three different techniques at different temporal scales because of different time sampling. On a daily basis and taking GPS as the reference value we have a bias or difference between Radiosonde and GPS measurements for the entire data base of 0.07 cm (relative bias of 3%) and RMSE of 0.33. For SP-GPS we have a bias of 0.14 cm (about 7%) and RMSE of 0.37. On a monthly basis the differences between Radiosonde and GPS values varies from summer with 2% to winter with -8% and between SP and GPS values from 3% in summer to -14% in winter. The observed bias between GPS and SP varies during each SP operational period, with lower values at the beginning of the measurements and increasing until the end of its measurement term and with the bias values being quite dependent on each individual SP. The observed differences highlight the importance of drift in each Sun-Photometer, because of filter aging or other calibration problems. Hence the comparison with GPS appears to be a powerful tool to assess the quality of Sun-Photometer for IWV retrieval.

54 ENVIRONMENTAL SCIENCES↗

Bayesian Estimation of Precipitation from Satellite Passive Microwave Observations Using Combined Radar-Radiometer Retrievals

Precipitation estimation from satellite passive microwave radiometer observations is a problem that does not have a unique solution that is insensitive to errors in the input data. Traditionally, to make this problem well posed, a priori information derived from physical models or independent, high-quality observations is incorporated into the solution. In the present study, a database of precipitation profiles and associated brightness temperatures is constructed to serve as a priori information in a passive microwave radiometer algorithm. The precipitation profiles are derived from a Tropical Rainfall Measuring Mission (TRMM) combined radar radiometer algorithm, and the brightness temperatures are TRMM Microwave Imager (TMI) observed. Because the observed brightness temperatures are consistent with those derived from a radiative transfer model embedded in the combined algorithm, the precipitation brightness temperature database is considered to be physically consistent. The database examined here is derived from the analysis of a month-long record of TRMM data that yields more than a million profiles of precipitation and associated brightness temperatures. These profiles are clustered into a tractable number of classes based on the local sea surface temperature, a radiometer-based estimate of the echo-top height (the height beyond which the reflectivity drops below 17 dBZ), and brightness temperature principal components. For each class, the mean precipitation profile, brightness temperature principal components, and probability of occurrence are determined. The precipitation brightness temperature database supports a radiometer-only algorithm that incorporates a Bayesian estimation methodology. In the Bayesian framework, precipitation estimates are weighted averages of the mean precipitation values corresponding to the classes in the database, with the weights being determined according to the similarity between the observed brightness temperature principal components and the brightness temperature principal components of the classes. Because the classes are stratified by the sea surface temperature and the echo-top-height estimator, the number of classes that are considered for retrieval is significantly smaller than the total number of classes, making the algorithm computationally efficient. The radiometer-only algorithm is applied to TMI observations, and precipitation estimates are compared with combined TRMM precipitation radar (PR) TMI reference estimates. The TMI-only algorithm, supported by the empirically derived database, produces estimates that are more consistent with the reference values than the precipitation estimates from the version-6 TRMM facility TMI algorithm. Cloud-resolving model simulations are used to assign a latent heating profile to each precipitation profile in the empirically derived database, making it possible to estimate latent heating using the radiometer-only algorithm. Although the evaluation of latent heating estimates in this study is preliminary, because realistic conditional probability distribution functions are attached to latent heating structures in the algorithm s database, a generally positive impact on latent heating estimation from passive microwave observations is expected.

Grecu, Mircea↗

SU-D-BRD-03: Improving Plan Quality with Automation of Treatment Plan Checks

Purpose: To evaluate the effectiveness of an automated plan check tool to improve first-time plan quality as well as standardize and document performance of physics plan checks. Methods: The Plan Checker Tool (PCT) uses the Eclipse Scripting API to check and compare data from the treatment planning system (TPS) and treatment management system (TMS). PCT was created to improve first-time plan quality, reduce patient delays, increase efficiency of our electronic workflow, and to standardize and partially automate plan checks in the TPS. A framework was developed which can be configured with different reference values and types of checks. One example is the prescribed dose check where PCT flags the user when the planned dose and the prescribed dose disagree. PCT includes a comprehensive checklist of automated and manual checks that are documented when performed by the user. A PDF report is created and automatically uploaded into the TMS. Prior to and during PCT development, errors caught during plan checks and also patient delays were tracked in order to prioritize which checks should be automated. The most common and significant errors were determined. Results: Nineteen of 33 checklist items were automated with data extracted with the PCT. These include checks for prescription, reference point and machine scheduling errors which are three of the top six causes of patient delays related to physics and dosimetry. Since the clinical roll-out, no delays have been due to errors that are automatically flagged by the PCT. Development continues to automate the remaining checks. Conclusion: With PCT, 57% of the physics plan checklist has been partially or fully automated. Treatment delays have declined since release of the PCT for clinical use. By tracking delays and errors, we have been able to measure the effectiveness of automating checks and are using this information to prioritize future development. This project was supported in part by P01CA059827.

60 APPLIED LIFE SCIENCES↗

SU-F-P-51: Similarity Analysis of the Linear Accelerator Machines Based On Clinical Simulation

Purpose: To evaluate the clinical rationale for Truebeam and Trilogy Linac machines from Varian Medical System as exchangeable treatment modalities in the same radiation oncology department. Methods: Intensity Modulated Radiotherapy (IMRT) plans for different diseases were selected for this study. These disease sites included brain, head and neck, breast, lung, and prostate. The parameters selected for this study were the energy amount, Monitor Unit (MU); dose coverage of target reflected by prescription isodose volume(PIV); dose spillage described by the volume of 50% isodoseline of the prescription; and dose homogeneities represented by the maximum dose (MaxD) and the minimum dose (MinD) of target volume (TV) and critical structure (CS). Each percentage difference between the values of these parameters formed an element of a matrix, which was called Similarity Comparison Matrix(SCM). The elements of the SCM were then simplified by dimensional conversion algorithm, which was used to determine clinical similarity between two machines through a single value. Results: For the selected clinical cases in this study, the average percentage differences between Trilogy and Truebeam in MU was 0.28% with standard deviation(SD) 0.66%, PIV was 0.23% with SD 0.20%, Volume at 50% prescription dose was 0.31% with SD at 0.78%, MaxD at TV is 0.26% with SD 0.35%, MinD at TV is −0.04% with SD 0.51%, MaxD in CS is −0.53% with SD 0.92%, and MinD in CS 3.31%, with SD at 2.89%. The sum, product, geometric and harmonic mean for the matrix elements were 19.0%, 0.00%, 0.19%, and 0.00%. Conclusion: A method to compare two machines in clinical level was developed and some reference values were calculated for decision-making in clinical practice, and this strategy could be expanded to different clinical applications.

60 APPLIED LIFE SCIENCES↗