Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Improving Heat Conduction of Insulated Metal Substrate with Thermal Pyrolytic Graphite Core for SiC Power Module Packaging

TPG-core IMS concept was jointly explored in this study. Integrating high thermally conductive TPG graphite core into IMS is expected to simultaneously achieve high thermal conductivity from TPG and electrical functionalities from IMS. Nearly 2x thermal conductivity and 30% weight saving was demonstrated on TPG-core IMS compared to conventional Cu-core IMS. Significant junction temperature reduction (11°C) in steady state and power cycling was revealed by the thermal analysis as the result of improved thermal spreading in plane and through the thickness. The study also proved the manufacturability and compatibility of this TPG-core IMS structure to the existing IMS production and power module assembling. Finally, the integration of TPG and IMS paves a new packaging route to increase heat load, improve reliability, simplify module design and reduce assembling cost and number of steps.

36 MATERIALS SCIENCE↗

Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger

An active thermal control system architecture has been modified to include a regenerative heat exchanger (regenerator) inboard of the radiator. Rather than using a radiator bypass valve a regenerative heat exchanger is placed inboard of the radiators. A regenerator cold side bypass valve is used to set the return temperature. During operation, the regenerator bypass flow is varied, mixing cold radiator return fluid and warm regenerator outlet fluid to maintain the system setpoint. At the lowest heat load for stable operation, the bypass flow is closed off, sending all of the flow through the regenerator. This lowers the radiator inlet temperature well below the system set-point while maintaining full flow through the radiators. By using a regenerator bypass flow control to maintain system setpoint, the required minimum heat load to avoid radiator freezing can be reduced by more than half compared to a radiator bypass system.

Ungar, Eugene K.↗

An analysis of alcohol compression ignition strategies on different engine platforms

Strategies that enable ignition of the low cetane alcohol fuels (methanol and ethanol) include intake heating (direct or via hot residual trapping), increased compression ratio (CR), multi-injection strategies, ignition enhancers, and active prechambers. The literature consistently shows alcohol compression ignition (CI) is more efficient than diesel at high loads irrespective of ignition strategy but shows contradictory results at low loads. To understand this, this work combines data from four different engine platforms ranging from a displaced volume of 0.4 to 2.1 L/cyl. using different alcohol CI ignition strategies. Using modeling to support experimental analysis, alcohol-specific efficiency penalties are highlighted to inform alcohol combustion system development. The alcohols’ lower energy density means more fuel must be injected near top dead center to achieve a given load, increasing the relative penalty of sensible/latent heating. Pilot injections help reduce this penalty. Intake heating incurs both a heat transfer penalty and a thermodynamic penalty due to a reduced ratio of specific heats during compression. A strategy that combines elevated CR, large pilot injections, and ignition enhancers can avoid this penalty. Alternatively, a prechamber strategy can achieve this without changing the CR, nor needing ignition enhancers in the fuel. At low loads, diesel burns in a partially premixed mode characterized by high burn rates and low heat losses, reducing alcohol-specific combustion benefits. Alcohol CI on the light-duty platform showed abnormally high heat transfer over diesel compared to other platforms, favoring a more premixed/partially premixed strategy despite a combustion efficiency tradeoff.

33 ADVANCED PROPULSION SYSTEMS↗

Taming harmful bursts and heat flux in high-confinement tokamak plasmas

A major challenge in tokamak fusion research is first-wall erosion caused by steady heat loads and sudden energy bursts known as edge-localized modes. Divertor detachment reduces steady-state heat flux, while resonant magnetic perturbations can suppress these instabilities. However, integrating the two has been difficult because they require conflicting operating conditions. Here we demonstrate simultaneous achievement of resonant magnetic perturbations mitigated small edge-localized modes and impurity seeded partial divertor detachment in plasmas with an ITER-similar shape on the DIII-D tokamak. Experiments and simulations show that resonant magnetic perturbations facilitate detachment by redistributing particles, lowering the core density and increasing the scrape-off layer density, thereby reducing the amount of injected gas required. Cooling-gas injection eliminates the secondary heat-flux peak created by three-dimensional magnetic lobes, while edge cooling weakens the plasma response to the applied magnetic fields. These advances illustrate a viable pathway for integrating edge stability control with power exhaust in future fusion reactors.

magnetically confined plasmas↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

Experimental studies of transpiration cooling with shock interaction in hypersonic flow, part B

This report describes the result of experimental studies conducted to examine the effects of the impingement of an oblique shock on the flowfield and surface characteristics of a transpiration-cooled wall in turbulent hypersonic flow. The principal objective of this work was to determine whether the interaction between the oblique shock and the low-momentum region of the transpiration-cooled boundary layer created a highly distorted flowfield and resulted in a significant reduction in the cooling effectiveness of the transpiration-cooled surface. As a part of this program, we also sought to determine the effectiveness of transpiration cooling with nitrogen and helium injectants for a wide range of blowing rates under constant-pressure conditions in the absence of shock interaction. This experimental program was conducted in the Calspan 48-Inch Shock Tunnel at nominal Mach numbers of 6 and 8, for a Reynolds number of 7.5 x 10(exp 6). For these test conditions, we obtained fully turbulent boundary layers upstream of the interaction regions over the transpiration-cooled segment of the flat plate. The experimental program was conducted in two phases. In the first phase, we examined the effects of mass-addition level and coolant properties on the cooling effectiveness of transpiration-cooled surfaces in the absence of shock interaction. In the second phase of the program, we examined the effects of oblique shock impingement on the flowfield and surface characteristics of a transpiration-cooled surface. The studies were conducted for a range of shock strengths with nitrogen and helium coolants to examine how the distribution of heat transfer and pressure and the characteristics of the flowfield in the interaction region varied with shock strength and the level of mass addition from the transpiration-cooled section of the model. The effects of the distribution of the blowing rate along the interaction regions were also examined for a range of blowing rates through the transpiration-cooled panels. The regions of shockwave/boundary layer interaction examined in these studies were induced by oblique shocks generated with a sharp, flat plate, inclined to the freestream at angles of 5 degrees, 7.5 degrees, and 10 degrees. It was found that, in the absence of an incident shock, transpiration cooling was a very effective method for reducing both the heat transfer and the skin friction loads on the surface. The helium coolant was found to be significantly more effective than nitrogen, because of its low molecular weight and high specific heat. The studies of shock-wave/transpiration-cooled surface interaction demonstrated that the interaction region between the incident shock and the low-momentum transpiration-cooled boundary layer did not result in a significant increase in the size of attached or separated interaction regions, and did not result in significant flowfield distortions above the interaction region. The increase in heating downstream of the shock-impingement point could easily be reduced to the values without shock impingement by a relatively small increase in the transpiration cooling in this region. Surprisingly, this increase in cooling rate did not result in a significant increase in size of the region ahead of the incident shock or create a significantly enlarged interaction region with a resultant increase in the distortion level in the inviscid flow. Thus, transpiration cooling appears to be a very effective technique to cool the internal surfaces of scramjet engines, where shocks in the engine would induce large local increases in wall heating and create viscous/inviscid interactions that could significantly disturb the smooth flow through the combustor. However, if hydrogen is used as the coolant, burning upstream of shock impingement might result in localized hot spots. Clearly, further research is needed in this area.

Holden, Michael S.↗

A Compact, Continuous Adiabatic Demagnetization Refrigerator with High Heat Sink Temperature

In the continuous adiabatic demagnetization refrigerator (ADR), the existence of a constant temperature stage attached to the load breaks the link between the requirements of the load (usually a detector array) and the operation of the ADR. This allows the ADR to be cycled much faster, which yields more than an order of magnitude improvement in cooling power density over single-shot ADRs. Recent effort has focused on developing compact, efficient higher temperature stages. An important part of this work has been the development of passive gas-gap heat switches that transition (from conductive to insulating) at temperatures around 1 K and 4 K without the use of an actively heated getter. We have found that by carefully adjusting available surface area and the number of He-3 monolayers, gas-gap switches can be made to operate passively. Passive operation greatly reduces switching time and eliminates an important parasitic heat load. The current four stage ADR provides 6 micro W of cooling at 50 mK (21 micro W at 100 mK) and weighs less than 8 kg. It operates from a 4.2 K heat sink, which can be provided by an unpumped He bath or many commercially available mechanical cryocoolers. Reduction in critical current with temperature in our fourth stage NbTi magnet presently limits the maximum temperature of our system to approx. 5 K. We are developing compact, low-current Nb3Sn magnets that will raise the maximum heat sink temperature to over 10 K.

Shirron, P. J.↗

Shuttle active thermal control system development testing. Volume 1: Overall summary

A summary is given of a series of thermal vacuum tests designed to support the development of the orbiter active thermal control system (ATCS) and included testing of a wide heat load range modular radiator system (MRS) configured to the March 1973 orbiter baseline system, a candidate weight reducing radiator/water cooling system, and a smaller radiator system with a high performance radiator coating. The tests verified the performance of the baseline system and obtained detailed design information for application of a wide heat load range modular radiator system to the orbiter. The two candidate ATCS weight reducing designs have undergone extensive concept verification testing and their system operating characteristics have been determined in sufficient detail for application to the orbiter. Design information has been obtained for an integrated radiator/water cooling system that provides for vehicle heat rejection as well as water management of the excess fuel cell water. Processing techniques have been developed and verified for the application of a high performance thermal control coating to large radiator areas subjected to a temperature range of -280 F to +160 F.

Howell, H. R.↗

Feasibility of Passive Cryogenic Cooling for Solar Powered Outer Planetary Missions

Spacescience instruments with cooled detectors require innovative thermal cooling solutions to meet science objectives. Detector sensitivity increases with decreasing temperature and low optics temperatures are often needed to reduce background photon noise. As the detector spectral range coverage increases from the visible to far infrared also requires lower detector temperatures. Increasing demands on detector performance lead to larger format detectors and higher refresh rates resulting in significant increases in power dissipation. Passive coolers rely on emissive power of radiating surfaces to reject heat to space. As the operating temperature requirements of detectors and optics decreases, the ability to reject heat to space becomes increasingly more difficult. Reducing both cooler internal parasitic and external environmental heat loads and maximizing the passive cooler field of view to space will enhance performance. While instrument heat loads and passive cooler parasitic heat loads are controlled by instrument designers, the external environmental heat loads and cooler views to space are governed by spacecraft and mission designers. Solar powered planetary missions require large arrays to generate sufficient power for spacecraft subsystems and payloads. Two or more solar array wings with cell coverage of the order of 40-80 m2 are often needed to generate sufficient power at 3-6 AU. These large arrays are typically symmetrically configured and can extend tens of meters. The arrays along with spacecraft attitude requirements near the target planetary bodies pose significant challenges for passive cooling at large AU. It is very difficult to provide a clear field of view to space for the cooler with large articulating arrays while keeping solar loads from impinging the cooler and meeting the spacecraft attitude science pointing requirements. This is counter intuitive because of the decreasing solar flux and colder planetary body temperatures at large AU. This paper presents the challenges and opportunities of passive cryogenic cooling versus active cooling for solar powered planetary missions.

Rodriguez, Jose I.↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Unsteady pressure loads in a generic high speed engine model

Unsteady pressure loads were measured along the top interior wall of a generic high-speed engine (GHSE) model undergoing performance tests in the combustion-Heated Scramjet Test Facility at the Langley Research Center. Flow to the model inlet was simulated at 72000 ft and a flight Mach number of 4. The inlet Mach number was 3.5 with a total temperature and pressure of 1640 R and 92 psia. The unsteady pressure loads were measured with 5 piezoresistive gages, recessed into the wall 4 to 12 gage diameters to reduce incident heat flux to the diaphragms, and distributed from the inlet to the combustor. Contributors to the unsteady pressure loads included boundary layer turbulence, combustion noise, and transients generated by unstart loads. Typical turbulent boundary layer rms pressures in the inlet ranged from 133 dB in the inlet to 181 dB in the combustor over the frequency range from 0 to 5 kHz. Downstream of the inlet exist, combustion noise was shown to dominate boundary layer turbulence noise at increased heat release rates. Noise levels in the isolator section increased by 15 dB when the fuel-air ratio was increased from 0.37 to 0.57 of the stoichiometric ratio. Transient pressure disturbances associated with engine unstarts were measured in the inlet and have an upstream propagation speed of about 7 ft/sec and pressure jumps of at least 3 psia.

Parrott, Tony L.↗

Energy Impact of Radiative Cooling Paints in Warehouses Under Various United States Climates

Although radiative cooling research is widely found in the literature, no comprehensive study has yet been conducted on the impact of novel radiant cooling (>0.91 reflectance) on the energy efficiency of warehouses. Here, in this work, we develop three building models based on a Department of Energy prototype warehouse model using trnsys, representing a typical warehouse with a black roof, a typical warehouse with a white roof, and a warehouse with novel radiative cooling (RC) paint on its roof. These models are run for 15 different cities, each representative of a different ASHRAE climate zone, to better understand the impact of RC in many different climates. It was found that an RC-coated roof in a warehouse could reduce the building's annual heating, ventilation, and air conditioning (HVAC) loads by up to 14.11 kWh/m 2 of the roof area compared to a black roof, resulting in a maximum reduction in energy costs of 0.55 $\$$/m 2 or $\$$2646/year for a large 4835 m 2 warehouse. Similarly, replacing the typical white roof coating with an RC coating could reduce the warehouse's energy consumption by up to 8.17 kWh/ m 2 of roof area, thus reducing energy costs by as much as 0.29 $\$$/m 2 or $\$$1386/year for a 4835 m 2 warehouse. In addition, applying RC paint to an unconditioned warehouse could reduce the building's ASHRAE Standard 55 indoor temperature exceedance by up to 1330 h/year compared to a black roof and up to 532 h/year compared to a white roof.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Boil-Off Reduction System Testing

Cryogenic propellants such as liquid hydrogen (LH2) and liquid oxygen (LO2) are a part of NASA's future space exploration due to the high specific impulse that can be achieved using engines suitable for moving 10's to 100's of metric tons of payload mass to destinations outside of low earth orbit. However, the low storage temperatures of LH2 and LO2 cause substantial boil-off losses for missions with durations greater than several days. The losses can be greatly reduced by incorporating high performance cryocooler technology to intercept heat load to the propellant tanks and by the integration of self-supporting multi-layer insulation. The active thermal control technology under development is the integration of the reverse turbo- Brayton cycle cryocooler to the propellant tank through a distributed cooling network of tubes coupled to a shield in the tank insulation and to the tank wall itself. Also, the self-supporting insulation technology was utilized under the shield to obtain needed tank applied LH2 performance. These elements were recently tested at NASA Glenn Research Center in a series of three tests, two that reduced LH2 boil-off and one to eliminate LO2 boil-off. This test series was conducted in a vacuum chamber that replicated the vacuum of space and the temperatures of low Earth orbit. The test results show that LH2 boil-off was reduced 60% by the cryocooler system operating at 90K and that robust LO2 zero boil-off storage, including full tank pressure control was achieved.

Propellant Storage↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat load measurements for the PIP-II pHB650 cryomodule

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of testing and to continue pinpointing any sources of unexpectedly high heat loads.. The programme measured HTTS, LTTS, and 2 K isothermal/non-isothermal loads under "standard", "linac", and "simulated dynamic" operating modes, recording data both inside the cryomodule and across the bayonet can circuits. Thermal-acoustic oscillations were eliminated by replacing the original G10 cooldown-valve stem with a stainless-steel stem fitted with wipers. A newly developed Python script automated acquisition of ACNET data, performed real-time heat-load calculations, and generated plots and tables that were posted to the electronic logbook within minutes, vastly reducing manual effort and accelerating feedback between SRF and cryogenics teams. Analysis showed that JT heat-exchanger effectiveness and temperature stratification in the two-phase and relief piping strongly influence the observed loads and helped isolate sources of excess heat. The campaign demonstrates that rigorous pre-test planning, real-time diagnostics, and automated reporting can improve both accuracy and efficiency, providing a template for future PIP-II cryomodule tests and for implementing targeted heat-load mitigations.

Porwisiak, D. [Fermilab; Wroclaw Tech. U.] (ORCID:↗

Large Eddy/Reynolds-Averaged Navier-Stokes Simulations of CUBRC Base Heating Experiments

ven with great advances in computational techniques and computing power during recent decades, the modeling of unsteady separated flows, such as those encountered in the wake of a re-entry vehicle, continues to be one of the most challenging problems in CFD. Of most interest to the aerothermodynamics community is accurately predicting transient heating loads on the base of a blunt body, which would result in reduced uncertainties and safety margins when designing a re-entry vehicle. However, the prediction of heat transfer can vary widely depending on the turbulence model employed. Therefore, selecting a turbulence model which realistically captures as much of the flow physics as possible will result in improved results. Reynolds Averaged Navier Stokes (RANS) models have become increasingly popular due to their good performance with attached flows, and the relatively quick turnaround time to obtain results. However, RANS methods cannot accurately simulate unsteady separated wake flows, and running direct numerical simulation (DNS) on such complex flows is currently too computationally expensive. Large Eddy Simulation (LES) techniques allow for the computation of the large eddies, which contain most of the Reynolds stress, while modeling the smaller (subgrid) eddies. This results in models which are more computationally expensive than RANS methods, but not as prohibitive as DNS. By complimenting an LES approach with a RANS model, a hybrid LES/RANS method resolves the larger turbulent scales away from surfaces with LES, and switches to a RANS model inside boundary layers. As pointed out by Bertin et al., this type of hybrid approach has shown a lot of promise for predicting turbulent flows, but work is needed to verify that these models work well in hypersonic flows. The very limited amounts of flight and experimental data available presents an additional challenge for researchers. Recently, a joint study by NASA and CUBRC has focused on collecting heat transfer data on the backshell of a scaled model of the Orion Multi-Purpose Crew Vehicle (MPCV). Heat augmentation effects due to the presence of cavities and RCS jet firings were also investigated. The high quality data produced by this effort presents a new set of data which can be used to assess the performance of CFD methods. In this work, a hybrid LES/RANS model developed at North Carolina State University (NCSU) is used to simulate several runs from these experiments, and evaluate the performance of high fidelity methods as compared to more typical RANS models. .

Salazar, Giovanni↗

Dynamic modeling of heat pipe integrated thermal battery latent heat storage system experiment validation

A heat pipe integrated thermal battery system has been constructed to investigate a high-temperature latent heat thermal energy storage technology that takes advantage of near isothermal operation of latent heat storage and heat pipes to potentially enable high-energy isothermal heat storage. A dynamic model constructed in Modelica has been validated, showing errors between 2.5 °C–39.7 °C across 10-h to 47-h simulations against experiment results, showing good prediction capability of experiment output, especially against phase change time. Model calibrations showing vessel heat-up capability of 3 kW and heat pipes combining to provide 600 W each during experiment operation validate experiment circumstances including reduced material loading and reduced power capability. The experiment configuration uses an Al-Mg-Zn eutectic metal as the storage material, heated via heat tape wrapped around the vessel and guide tubes to bring the system to operation range (>400 °C) and to simulate charging heat exchange, respectively, with heat rejection occurring through the surfaces of the material and facilitated via guide tubes with less insulation wrapping. The model is available in the open-source repository HYBRID on Github.

25 - ENERGY STORAGE↗

Power Controller

The device called the Power Factor Controller (PFC) offers exceptional energy conservation potential by virtue of its ability to sense shifts in the relationship between voltage and current flow, and to match them with the motor's need. Originating from the solar heating/cooling program, the PFC senses a light load, it cuts the voltage level to the minimum needed which in turn reduces current flow and heat loss. Laboratory tests showed that the PFC could reduce power used by six to eight percent under normal motor loads, and as much as 65 percent when the motor was idling. Over 150 companies have been granted NASA licenses for commercial use of this technology. One system that utilizes this technology is the Vectrol Energy System, (VES) produced by Vectrol, Inc. a subsidiary of Westinghouse. The VES is being used at Woodward & Lothrop, on their escalators. Energy use is regulated according to how many people are on the escalator at any time. It is estimated that the energy savings are between 30 to 40 percent.

Source record↗